| 1 | Excavating over areas, exc 1.5 m deep and getting out soft soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed. |
| 3 | M & L for PCC 1:3:6 Cement concrete type C 2 (using 40 mm grade aggregate ) in foundations, filling and mass concrete as specified |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. |
| 5 | Removing excavated material (soil) n. exc 50m and deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 6 | M & L for brickwork in CM 1 :4 with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built inas specified |
| 7 | M & L for rendering 15 mm thick (1:4) on fair faces of brick work or concrete surfaces rendering is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 8 | M & L for PCC 1:3:6 type C1 ( using 20 mm graded crushed stone aggregate)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specifiedand directed. |
| 9 | M & L for cement concrete 1: 3: 6 type C-1 asin surface channels using 40 mm graded stone aggregate and drains and extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed. |
| 10 | M & L for precast cement concrete 1:2:4 type B-1using ( 20 mm Graded crushed stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specifiedand directed. |
| 11 | M & L for RCC 1:1.5:3 (using 20 mm graded crushed stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 12 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 13 | M & L for rough finished flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widecomplete all as specified and directed |
| 14 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 15 | M & L for cement concrete bed (1:4: 8) type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in for 150 mm dia SGSW pipe complete all as specified and directed. |
| 16 | M & L for 150 mm dia Salt -glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed. |
| 17 | M & L for cutting into existing manholes for using 150 mm dia of pipe internal dia connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching complete all as specified and directed. |
| 18 | M & L for PVC (SWR) 75 mm dia pipes single socketed in any length with rubber ring joints fixed to walls complete all as specifiedand directed. |
| 19 | S & F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 20 | M&L for construction of Soakage well, of size 3.6 m dia at bottom and 3 m total depth complete all as specified and shown on drawing No. CESZ-TD-/2015 sheet No 1/3 & 3/3 dated 22 Feb 2015 (Revised dt 21 Mar 2015) and specified in particular specifications. |
| 21 | M & L for mild steel framed work for such as grills, grating etc with ends of bars shouldered and or riveted, or forged into spikes; framed guard bars; barred iron doors ladders frames balusters walk ways railings framework of water tanks and similar work conforming to Fe 290 Gde-E- 165 complete all as specified and directed. |
| 22 | M&L for preparation of New steel surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint on Newsurfaces, over a one coat of complete all as specifiedand directed. |
| 23 | M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper complete all as specifiedand directed. |
| 24 | Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed. |
| 25 | Taking down MCB DB\"s complete with MCB\"s/Isolator etc removing materials from siteand making good disturbed surface of walls, floors etc. complete all as specified and directed. |
| 26 | Disconnecting unserviceable sub main wiring/service connection of any size and including steel conduit and accessories and removing from site and making good the disturbed surfaces complete all as specified and directed. |
| 27 | M & L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green color) as earth lead in and including cable 1100 volts grade including casing and capping/ conduit (ISI marked)including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxesof suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc, covered with plastic laminated sheet or PVC gang box2 to 8 way as per site requirement fitting in surface mount or concealed including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specifiedand directed. |
| 28 | All as per item No 27 herein before but wiring with 1.5 sqmm copper wire (FRLSH)and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board. |
| 29 | All as per item No 27 herein before but wiring with 1.5 sqmm copper wire (FRLSH)and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board. |
| 30 | All as per item No 27 herein before but wiring with 2.5 sqmm copper wire ( FRLSH)and 1.5 sqmm earth wire for switch socket combination 6 pin 15 amps on independent board. |
| 31 | S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. |
| 32 | S & F switch socket combination 2 in 1,5A, flush type complete all as specified and directed. |
| 33 | S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. |
| 34 | S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 35 | Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 36 | M & L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed. |
| 37 | Supply and fix LED Bulb 9 Watt all complete all as specified and directed. |
| 38 | S&F 09W/10W Bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specifiedand directed. |
| 39 | M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion including complete earth work complete all as specifiedand directed. |
| 40 | S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for single door IP-42 DB\"s, made out of sheet steel enclosure, recessed type, factory made powder coated 8 way 240 volts suitable for housing MCB\"s and isolator\"s complete in all fixing material/accessories etc complete all as specified and directed. |
| 41 | S&F MCB\"s single pole 240 volts 6 to 32Amps 10 KA \"C\" series, complete all as specified and directed. |
| 42 | S & F of MCB SPN, 240volt, 40 to 63 Amp capacity, 10 KA, \"C\" curvecomplete all as specifiedand directed. |
| 43 | M & L for wiring for circuit/submain wiring along with earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping of size 2x6 sq. mm + 1x4 sq. mm earth wire, complete all as specified and directed. |
| 44 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm nominal cross section in service connections, complete all as specified and directed. |
| 45 | Dismantling of old unserviceable ACSR conductors from existing PCC/RCC/ Steel poles complete all as specified and directed. |
| 46 | Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel) complete all as specified and directed. |
| 47 | Dismantling of mild cross arms of MS channel or angle section etc complete all as specified and directed. |
| 48 | Dismantling street light fitting of any size and type complete all as specified and directed. |
| 49 | Dismantling cable protection pipe 25/40/50/80 mm dia complete all as specified and directed. |
| 50 | Taking out old unserviceable service mains/cable complete all as specified and directed. |
| 51 | Taking out old unserviceable/ broken street light bracket complete all as specified and directed. |
| 52 | Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 50 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. |
| 53 | Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 16 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. |
| 54 | Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 10 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed Note for srl item No 52 to 54 :- (a) Earth workshall be measured and paid separately. |
| 55 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, |
| 56 | connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specifiedand directed. |
| 57 | Supply, install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primercompleteall as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories . |
| 58 | (a) Aluminium barcap 100 Amp- 04 Nos. |
| 59 | (b)MCCB four pole with thermal magnetic release adjustable type with breaking capacity 35 KA,63 Amp- 01 No. |
| 60 | (c)Digital Voltmeter-96 x 96 mm flush secure Panel mounting type 0-500V with selector switch- 01 No. |
| 61 | (d) Digital Amp meter96 mm X 96 mm flush secure Panel mounting type 0-100 Amps with selector switchwith CT - 01 No. |
| 62 | (e) RYB neon indicatinglamp setof three- 01 |
| 63 | Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (iii) Make of MCCB-AS per Appx \"B\" (iv) Make of LT Panel/Bus Bar chamber:-AS per Appx \"B\" of the BoQ (02 Nos)in Hindi and English ofsize 20cmx 15cm shall be fixed on the panel (vi) Contractor provided powder coated finish paint on panel and test certificate. |
| 64 | Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specifiedand directed.Note:-Punned thickness only shall be measured and paid. |
| 65 | Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class \"B\" laid in trenches flat complete all as specified and directed. |
| 66 | Supply and fixing tubes light grade GI tubing 50 mm dia with all fittings laid in trenches complete all as specifiedand directed. |
| 67 | Supply and fixing Busbar chambers (wall Mounted), busbar made of ETP Grade Copper, current rating (A) 63 Amps No of 6 way complete all as specified and directed. |
| 68 | Supply and fixing with replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 69 | S & F street light Engineering plastic one piece moulding control box with locking arrangementmade out ofHDPE and FI clamp 25 x 3mm complete ofdimensions in CM+/-10%(34x28x13) including MCB SP 6 Amp 240 Volts complete with 02 Nos aluminium busbar or terminal two Nos (2P-R/Y/B and N) of rating 63 amps for single phaseand neutral on porcelain based insulators complete all as specifiedand directed. |
| 70 | S & F GI bracket made out of GI pipe light grade of size 50/40/32 mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed. |
| 71 | M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0/11 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of alternate Yellow & Black Strips Painting (4 No. Each Strip 300 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed. |
| 72 | Supply and fixing 1100 volts grade heavy duty cable with PVC insulated solid/stranded copper conductor served with an inner sheathing of PVC tape and overall PVC sheathed of size 1.5 sqmm 3 core suitable for LED security light for pole box to street light fitting with connector and thimble, nut & bolt andwasher etc., complete all as specified and directed. |
| 73 | All as per ser item No 2 above but depth exceeding 1.5 m and not exceeding 3 m. |
| 74 | Material and labour for Cement concrete in bed of poles streets and stays 1:4:8 type D-2 using 40 mm graded crushed stone aggregate complete all as specifiedand directed. |
| 75 | Material and labour for Cement concrete 1:2:4 type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly complete all as specifiedand directed. |
| 76 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide including taking down old one complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule A. |
| 77 | Supply and fix street light control junction box 200x160x98mm made out ofthermoplastic and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 10 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size with bolts nuts & washers including taking down old one complete all as specifiedand directed. NOTE: - The unit rate quoted shall be deemed to includes for incoming & outgoing cables glands& lugs of size up to 10 sq mm 4 core |
| 78 | S & F bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm including taking down old one complete all as specifiedand directed. |
| 79 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Connection cable as required including taking down old one complete all as specified and directed. |
| 80 | Supply and fixing 40mm dia light grade GI galvanised with fittings, laid in trenches/wall/pole for protection of underground cable to Junction Boxincluding dismantling the existing unserviceable pipe complete all as specified and directed . |
| 81 | Supply and fixing 20mm dia light grade GI tubes galvanised with fittings, laid in trenches/wall/pole for protection of underground cable to Junction box including taking down old one complete all as specified and directed. |
| 82 | Supply & fixing multi stranded Copper Conductor cable of 3 Core 1.5 Sq mm for connection ofjunction box to lightincluding dismantling the existing unserviceable conductor complete all as specifiedand directed. |
| 83 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 6 Sqmm including dismantling the existing unserviceable cable complete all as specified and directed |
| 84 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 10 Sqmm including dismantling the existing unserviceable cable complete all as specified and directed |
| 85 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm including dismantling the existing unserviceable cable complete all as specified and directed |
| 86 | Taking up the unserviceable XLPE LT UG cable 3.5/ 4 core 16 Sqmm to 95 Sqmm from trenches or walls complete all as specified and as directed. |
| 87 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5/4 core 25 Sqmm sqmm cross sectional area in trenches or walls complete all as specified and as directed. Note:Excavation & Earth work sand cushioning GI Pipe and brick for cable protection will be measured and paid separately |
| 88 | S & F MCCB 4 pole 200A, 36 KA including dismantling the existing unserviceable MCCB complete all as specifiedand directed. |
| 89 | All as per item No. 81 above but 125/100 Amp Capacity 25 KA including dismantling the existing unserviceable complete all as specifiedand directed. |
| 90 | All as peritem No. 81 above but 3 pole 63-100 Amp Capacity 16 KA including dismantling the existing unserviceable.Complete all as directed |
| 91 | Supply and fix inLT Straight through joint heat shrinkable 1100 volts, 25 sqmm to 50 sqmm including dismantling the existing unserviceable joint complete all as specifiedand directed. |
| 92 | S & F in replacement of manualchange over switch 415 volt in sheet metal enclosure 3/4 pole of capacity from 250 Amp complete all as specifiedand directed. |
| 93 | Supply, installation, testing and commissioning industrial RO + UV + PHE + softener water purifier system of capacity 200 LPH consisting of three numbers fibre reinforced polymer vessel with treatment media like FBM, AFM, MGS, ACM, CPM, softener media etc along with back wash system with multiport valves, strainer, feed water pump, high pressure pump, RO element, ultra violet system with electric control panel and internal and internal CPVC pipe fitting, gate valves, non return valves, inlet and outlet connections fitted on wall furnished and painted MS frame and including suitable size of PCC foundation complete in all aspect with anti scalant dosing system, PH enhancer dosing system and containers complete all as specifiedand directed. |
| 94 | S & F stainless steel water storage tank with double wall insulated and steel of grade SS316 & SS304 of capacity 1000 Ltrs and diameter 1600 mm including Staging with MS frame as per height manufacturer specification complete all as specifiedand directed. |
| 95 | M&L for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. |
| 96 | M & Lrotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed including Staging with suitable size MS frame/PCC foundationas per height manufacturer specification in position complete all as specifiedand directed. |
| 97 | Supply, installation, commissioning of Glass Top Deep Freezer of capacity 320 Ltrs single phase 240 volt, 50 Hz complete all as specified and directed. |
| 98 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and directed. |