| 1 | Excavating over areas n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | All as per BOQ Item No 1.00 here-in-beforebut of depth exc 1.5m and not exceeding 3.00 mtrs complete all as specified and directed. |
| 3 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 4 | All as per BOQ Item No 3.00 here-in-beforebut of depth exc 1.5m and not exceeding 3.00 mtrs completeall as specified. |
| 5 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed. |
| 6 | Removing excavated spoil to a distance not exc. 50m and depositing where directed at alevel not exc. 1.5 m above the starting point complete all as specified and as directed. |
| 7 | Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premisesall asspecified and directed. |
| 8 | M & L for PCC type D2 1:4:8 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concretecomplete all as specified. |
| 9 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided (reinforcement cut as required to facilitate demolition), completeremoval of the rubbish off the premisesall asspecified and directed. |
| 10 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 11 | M & L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 12 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 13 | M & L for RCCM-25 design mix concrete with using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns,etc.; complete all as specified and directed. |
| 14 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fairfinished surface of concrete Complete all as specified and directed. |
| 15 | M/L for Reinforcement cement concrete M-25 using 20 mm graded crushed stone aggregateas in column, pillars, piers, posts and struts etc all as specified and directed. |
| 16 | Demolition for brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, facings and removal or rubbish off the site complete all as specified and directed. |
| 17 | M & L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6. |
| 18 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 onfair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer\"s instruction,complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 19 | Supply only liquid WPC, complete all as specified and directed. |
| 20 | M&L forpavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6(ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 21 | M&L for Hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 22 | S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 23 | S & F MS J bolts minimum 16 bolt dia screw end to be fixed with washers and nut exc 45 cm but n.exc 75 cm long complete all as specified and directed. |
| 24 | M&L for preparing of new steel & ironsurfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 25 | M & L for 100 mm thick Cement concretetype C-2, 1:3:6 (using 40mm graded crushed stoneaggregate) as in sub base, sub floors etc complete all as specified and as directed. |
| 26 | M&L for 75 mm thickcement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fairlaid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified. |
| 27 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 28 | S & F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering, door etc to be prepared for sliding with and including either hooks and hinges, also fastening and fixing complete all as specified and directed. |
| 29 | S & F Roof trusses (framed) of angle iron members trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 30 | Erection and fixing only of Roof trusses (framed) of angle iron members trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed. |
| 31 | M&L 3 mm thick any colour ACP board ( Aluminium composite panel ), exterior grade (approved colour) fixed with aluminium frame /other similar frame work all as specified and as directed. |
| 32 | M & L for Providing, fabricating, and fixing maintenance-free and weatherproof 3D individual letters of the English alphabet, each with a height of 30 inches. The letters shall be fabricated using high-quality, UV-resistant cast acrylic sheets (min. 3mm–5mm thickness for fascia) with a 3-inch return (embossment) to create a 3D effect. The internal illumination shall be provided by energy-efficient, IP67/IP68 rated waterproof LED modulesensuring uniform front-lit glow without hotspots. The entire assembly shall be mounted on a sturdy base of 3mm thick Exterior Grade Aluminum Composite Panel (ACP) with a minimum 0.25mm coil thickness, fixed onto a concealed MS/GI square box pipe frame.The letters are to be securely screwed and fixed at any specified height or on the main gate. The work includes all necessary high-quality weatherproof wiring, IP67 rated power supply (SMPS), specialized fasteners, and finishing. The complete installation must be carried out to the entire satisfaction of the Engineer-in-Charge |
| 33 | All as per BOQ Item No 32.00 here-in-beforebut of individual numbers in Englisheach with a height of 36 inches completeall as specified. |
| 34 | All as per BOQ Item No 32.00 here-in-beforebut of 3D formations/logos of overall size 30 inch x 30 inch completeall as specified. |
| 35 | M & L for Providing, fabricating, and fixing 3D formation signs of size 36 inch x 36 inch made of Stainless Steel (Grade 304) of specified thickness (min. 18/20 gauge). The letters shall be precision laser-cut with required returns (depth) to provide a 3D effect. The finish shall be Brush/Hairline or Mirror finish as per the approved design.The signage is to be securely mounted onto the existing MS Gate using concealed studs, spacers, or specialized SS fasteners to prevent galvanic corrosion between the SS signage and the MS base. The work includes template marking, buffing, polishing, and cleaning of the surface to ensure a seamless finish. All work shall be completed in all respects, including all lead and lift, to the entire satisfaction of the Engineer-in-Charge |
| 36 | M&L for Glazed ceramic tiles Coloured 450 x 300mm 7 to 8 mm thick in wall/dado etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match renderingover 10 mm thick in CM 1:3 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed. |
| 37 | Material & Labour for applying and making brick design fort with Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including 2mm thick wall care putty over new surfaces complete all as specified and directed. |
| 38 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 10 sqmm. |
| 39 | Supply, Laying and testing cableLT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 25 sqmm. |
| 40 | M&L for Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) of 40mm dia laid in trenches for cable protection complete all as spcified and directed. |
| 41 | Supply and fixing for concealedtype sub main wiring with two run of 2.5 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 2.5 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 42 | Supply & Fix in repair MCB 6 to 32 Amps, SP, braking capacity 10KA, C series all as specified and directed.Make : L&T/Legrand/C&S |
| 43 | Supply & Fix in repair MCB 6 to 32 Amps, SPN, braking capacity 10KA, C series all as specified and directed. Make : L&T/Legrand/C&S |
| 44 | Supply & Fix sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including bus bar and earth link connector, fixed in wall complete including part of job all as directed by Engr-in-Charge.Make : L&T/Legrand/C&S |
| 45 | M&L for fixingGI tubing 40mm dia light grade use for the protection of cable all as specified and directed by Engr-in-Charge. |
| 46 | M&L for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed. |
| 47 | Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.00m x 0.45m x 1.00m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus barmade ofaluminium, 100 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade.The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB\"s, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parametersPCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories: |
| 48 | (A) IncomingMCCB63 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16/18 KA --- 01 Nos. (B) Outgoing(b) MCB32 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 10 KA --- 02 Nos(c) MCB16 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 10 KA --- 02 Nos(d) Astronomical Timer Switch 1 outlet 16 A-250V,vertical dial N/O contact,power supply 230V,50/60Hz,three position override switch \"ON-AUTO-OFF\" on front panel-01 Nos, 25A ,2 NOContactor 3 phase, with 230V coil-01 Nos, 32 A MCB TPN-01Nos with suitable relay and other accessoris and wiring if any required with min 1.5 Sqmm copper conductor cable and instrument wiring with 1.5 Sqmm fine, terminal blocks.(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 49 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI strip 32 x 6 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 40 mm diaGI pipe (md grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wireincluding protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |