Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-03-2026 | BOQ corrigendum | BOQ | 19-03-2026 |
| Sl. No. | Item Description |
| 1 | Excavating inpost holes( or similar holes) each n exc0.50 cum , getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C2, using 40mm graded crushed stone aggregate,asin foundation filling & mass concrete complete all as specified and directed. |
| 3 | M&L forProviding, cement concrete1:2:4type-B1 using 20mm graded crushed stone aggregate in lintels upto 1.5m clear span, cills, steps;roof padding, seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. |
| 4 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 6 | M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165and similar workcomplete all as specified and directed. |
| 7 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 8 | S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longcomplete all as specified anddirected. |
| 9 | M&L forMild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 10 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 11 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wirecomplete all as specified and directed. |
| 12 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed. (each line wire to be measured) |
| 13 | M&L for Running welding in repairs to doors, gates,holdfast etcnot exc 6mmcomplete all as specified and directed. |
| 14 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.Note:- Dia of fencee and mesh size as approved by GE |
| 15 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 16 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 17 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in sub base of floor/ floor path complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 19 | M&L for sheet glass, 3mm thick, plain ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each panecomplete all as specified and directed. |
| 20 | Hacking out old broken glass (any thickness size quality and discription) for metal frame exc 1.5 sqm including punching, drilling out old glazing pins / spring clips and providing new ones complete all as specified and directed. |
| 21 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 22 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 23 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortaretc complete all as specified and directed |
| 24 | Demolition of cement concrete( un-reinforced)in ground floorand paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 26 | Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified anddirected |
| 27 | Dismantling of fencing anytypecomplete all as specified and directed. |
| 28 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Posts embedded in Concrete, brick work, masonry, etccomplete all as specified and directed. |
| 29 | M&L for 100mm thick PCCtype B1,1:2:4 using 20mm graded crushed stone aggregate as in hard standing/floor/ path finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in plinth protectionfinishedeven and smoothusing extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed. |
| 31 | M&L for exterior grade(Lequre coated), coloured glossyfinish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thickset, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. completeincluding provision of 20mm screed in cement moertar 1:6, complete all as specified and directed. |
| 32 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; completeall as specified and directed. |
| 33 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L forrendering 15 mm thick in cement mortar 1:4 on fair faces surfaces of brick work or concrete surfaces mixed with WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 35 | M&L fornewly plastered surface of wall and appying two coat of white or tinted oil bound distemper over one coat of alkali resistant primer complete all as specified and directed. |
| 36 | M&L preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 37 | Dismantling cross armsof MS channels or angle sections etc complete all as specified and directed. |
| 38 | Dismantling insulators any type any sizes complete all as specifiedand directed. |
| 39 | Taking out old/Unsv damagedexisting steel/concrete poles of any size/length from existing position etc and demolition of PCC foundation and removing the same from site complete all as specified and directed. |
| 40 | M&L for following repair, serviceing and replacement of unserviceable accessories of LT Panel any make type/size includingwelding, brazing and drilling work:- (a) Tightening of all loose conectiont of cableinside the panel and welding the broken door of the panel. (b)Clean all the rusted busbar through hemry paper and fixing insulation heat shrink sleeves through out the busbar and epoxy insulatorincluding strip connected with out going MCCB.(c) Cutthe damage insulation portion end of cable inside the panel and reconnecting its into positions after fixing the end termintion/Sleeves complete with suitable size of aluminium lugs and stainless steel nut bolts including excavation and earth work in any type for taking out the existing cable loop to fixing the end joint or reconnection in position.(d) Repair/Replacement ofburnindication lamp including control wiring of the panel between voltmeter, Ammeter and their selector switch and CTs .(e)Repair/Replacement of all burn lugs inside the panel.(f) Replaced all the GI rusted nut, bolts,and washers with made of stainless steel nuts, bolts and washers.(g) Cleanthe dust inside the panel by air blower/vaccum cleaner and cutting the grass upto 2 meter surrounding the panel complete.Note : (a) The cost of nut bolts, washers, insulation tape,lugs etc essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. (b) Other spare parts/accessories shall measured and paid separatelyunder relevant items of schedule. |
| 41 | Supply only epoxy type insulator for support of busbar grade 1100 volt as per existing size. |
| 42 | Supply only LED phase indicator lamp colour RED/YELLOW/BLUE AC 220 Volt 50 Hz. |
| 43 | Materialand labourfor control wiring of the panel with 1.5 sq mm multistranded, PVC insulated copper conductor 1100 Volt grade FRLS cable. |
| 44 | Supply and fixingdigital Ampmeter of any range, flush mounting type of size96 mm x 96 mm (4”x4”) square dial 3 phase four wire system with selector switch. |
| 45 | Supply and fixing digital voltmeter of range (0-500) volts, flush mounting type of size96 mm x 96 mm (4”x4”) square dial 3 phase 4 wire system with selector switch. |
| 46 | Supply and fixing cast resin insulated type CT, Ratio 200/5Awith capable of withstanding momentary short circuitand symmetricalshort circuit for 1second including taking down old one all as per specified and directed please. |
| 47 | Supply and fixing cast resin insulated type CT, Ratio 250/5Awith capable of withstanding momentary short circuitand symmetricalshort circuit for 1second including taking down old one all as per specified and directed please. |
| 48 | Supply and fixing cast resin insulated type CT, Ratio 300/5Awith capable of withstanding momentary short circuitand symmetricalshort circuit for 1second including taking down old one all as per specified and directed please. |
| 49 | Supply only copper bus bar any size (5x20, 10x20, 10x25, 10x40, 10x50,10x80) mmduly insulated with heat shrink busbar insulation sleeves. |
| 50 | Supply only aluminium bus bar any of any size duly insulated with heat shrink busbar insulation sleeves. |
| 51 | M&L in repair for replacement of MS sheet cover of LT panel board made out of any thick MS sheet as per required shape and size including necessary fabrication,welding and two coats of synthetic enamel painting over a coats of red oxide after proper preparation of steel surface complete and fixing accessories etc to match with existing panel surface complete all as specified and directed. |
| 52 | M&L for spray painting in existing steel surface of Panel/FPB/JB etc with two coats of synthetic enamel including one coat red oxide in rusted area after proper cleaning and prepration of old painted surfaces steel / Iron of any description with spray machine complete all as specified and directed. (Note:- Painting of panels / feeder filler boxes shall be carried out in different colour of paints as required at site and as directed). |
| 53 | Excavating and relaying of cables loops near the poles, panels, distribution box, cutting the damages/burnt parts of cable and reconnecting in the same position with aluminium thimbles/lugs of same size of cable, nuts bolts and washer (made of stainless steel) with proper insulation and cable sleeves etc complete all as specified and directed by Engineer-in-Charge.Note : (i) Cost of nuts, bolts, washer, aluminium thimble/Lugs, insulation tape shall be deemed to be included in the quoted rate.(ii) Cost of sleeves measured and paid separately on relevant items of the schedule. |
| 54 | M&L earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 40 mm bore light grade GI pipe for protection of earth lead including provision ofconcrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed by Engr-in-charge. |
| 55 | S&F in repair of on load change over switch of capacity 200 Amp, 4 pole415 Volt AC in sheet metal enclosure with front handle including necessary fixing arrangment as required at site complete all as specified and directed. |
| 56 | S& Fin repair of copper spreader terminal Kitsuitable for MCCB capacity 63 to100 Amp of any make and as per existing MCCB at site complete all asspecified anddirected. |
| 57 | S& Fin repair of copper spreader terminal Kitsuitable for MCCB capacity 125- 200 Amp of any make and as per existing MCCB at site complete all asspecified anddirected. |
| 58 | S& Fin repair of copper spreader terminal Kitsuitable for MCCB capacity 200 to 320 Amp of any make and as per existing MCCB at site complete all asspecified anddirected. |
| 59 | S& Fin repair of copper spreader terminal Kitsuitable for MCCB capacity 400 Amp of any make and as per existing MCCB at site complete all asspecified anddirected. |
| 60 | M&L for PCC 1:4:8 type D:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundationetc all as specified and directed by Engineer-in-Charge. |
| 61 | M&L for PCC 1:3:6 type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly etcall as specified and directed by Engineer-in-Charge. |
| 62 | M&L for PCC 1:2:4 type B:1 using 20mm graded crushed stone aggreate as incoping of pole including necessaryform work and fair finish to exposed surfaces complete all as specified and directed. |
| 63 | M&L for crossarms bracing, supports, clamps and brick plates, fabricated fromstaructural steel section including nut bolts washers including welding, bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as all specified and as directed. |
| 64 | Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete. (Note Excavation & Earth work andPCCfoundation/baseshall be measured and paid separately under relevant items of this BoQ) |
| 65 | M & L forPainting ofsteel polewith cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia black circle with white letter painting of 3 Nos black & 02 Nos yellow bands width 30 cm by fluorescent paint in alternate layers upto 1.5 mtr heightabove theP.C.Ccopingandtwocoatofaluminiumpaintbeyond 1.5 meterheightcomplete all as specified and directed. |
| 66 | S&F in repairs MCCB 100 Amps 4 pole, 415 V, breaking capacity 16 KA,Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed. |
| 67 | S&F in repairsMCCB 160 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed. |
| 68 | S&F in repairsMCCB 200 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA,Ics=100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed. |
| 69 | S&F in repairsMCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100 % ICUincluding spreader terminals & connected accessories both ends complete all as specified and directed. |
| 70 | S&F in repairsMCCB 320 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed. |
| 71 | S&F in repairsMCB 400 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, 100% ICUincluding spreader terminals & connected accessories both ends complete all as specified and directed. |
| 72 | S&F in repairsMCB 63 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 16 KA, 100% ICUincluding spreader terminals & connected accessories both ends complete all as specified and directed. |
| 73 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified. |
| 74 | All as per item No 73above but depth excd 1.5 mtr and n. exc 3 mtr all as specified and directed. |
| 75 | Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified. |
| 76 | Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 77 | Supply and lay brick common burnt sub class \"B\" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable all as specified. |
| 78 | M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8 cm after laying the cable complete all as specified and directed. |
| 79 | Relaying of old serviceablebrick as in cable protection all as specified and directed. |
| 80 | Supply and fixingin repairfor cable protection GI tubinglight grade fixedalong the pole/wall/under road of size 50 mm bore with necessary clamps, nut and bolts all as specified and directed by Engineer -in-Charge. Note : Clamps,nut and bolt will be measured and paid separately. |
| 81 | All as per srl item No. 80here in before but Size 80 mm. |
| 82 | Taking out old unserviceable under ground cable of any size and any position from trenches, floors and wall and segrate the serviceable portion cable for reuse complete all as specified and directed. |
| 83 | Labour for drillinghole under the road with the help of bocki / by manual or by machinefor crossing GI tubingof any size 100 mm pipefor cable protection all as specified and directed. |
| 84 | Relaying of serviceable cable of any size retrieved here-in-above item after detecting the fault and making straight through jointing kit of 1100volt grade complete all as specified and directed.Note:-Necessary excavation,returning filling, removal of soil and straight through joint shall be measured and paid separately under respective item of this schedule. |
| 85 | Supply and laying XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of crossectionalarea120 Sqmm 3.5core laid in trenches/ducts/through pipes/in floor road/along the pole etc all as specified & directed by Engr-in-charge. Note : (a) Excavation earth work, brick protection and cushioning shall be measured & paid separately. |
| 86 | All as per srl item No. 85 here in before but size 70 Sqmm 3.5 core |
| 87 | All as per srl item No. 85 here in before but size 50 Sqmm 3.5 core |
| 88 | All as per srl item No. 85 here in before but size 35Sqmm 3.5 core |
| 89 | All as per srl item No. 85 here in before but size 25 Sqmm 4 core |
| 90 | All as per srl item No. 85 here in before but size 16 Sqmm 4 core |
| 91 | All as per srl item No. 85 here in before but size 10 Sqmm 4 core |
| 92 | M & L for PCC earth pit chamber of internal dimension (300x300x300) mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50 mm thick reinforced with 8 mm TMT bars both way @100mm c/c including one lifting handle and dismantling of old one complete all as specified and directed. |
| 93 | Supply and fixing in repair Galvanised iron strip 32 x 6 mm as continuity conductorcomplete all as specified and directed. |
| 94 | Supply and fixing in repair aluminium strip 25 x 3.15 mm including replacement of insulating blocks 3 Nos of one RM distance complete all as specified and directed. |
| 95 | S&F in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screw complete all as specified and directed. |
| 96 | Supply,laying & fixing double wall corrugated (DWC) pipes ofsize 63 mm outer dia and 50mm inner diamade of high density polythyline (HDPE) conforming to IS 16205(Part-24) in place of old Bricks including all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.. allas specified and directed by Engr in Charge |
| 97 | Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½core XLPE, armoured, Aluminium conductor cable of size 150 to 185 sqmm complete all as specified and as directed. |
| 98 | Ditto all as per item 97 but of size 70 to 120 sqmm –ditto. |
| 99 | Ditto all as per item 97 but of size 25 to 50 sqmm –ditto. |
| 100 | Ditto all as per item 97 but of size 6 to 16 sqmm 4 Core –ditto. |
| 101 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type LT panel board size 1000 mmx 900mmx500mm confirming to IS 8623, CPRI approved, factory fabricated &factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penalmade out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & includingbusbars made of pure copperduly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitableearth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories including installation of panel andframe pedestal legsmade of ISA 5050 of size 40x40x5 mm of length800 mm . 350 mmbelow the ground and 450 mm above thegoundlevel grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate).Panel shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- |
| 102 | Incoming (a) Copperbus bar - 300 Amps rating - 04 Nos. for phases and neutral(b) MCCB 4 Pole 200 Amp 36 KA, 415 Volt, 100% ICU, adjustable thermal magnetic protection (O/L & S/C protection) -01 No(c)3 phase Voltmeter (0-500V) digital type with inbuilt selector switch-01 No. (d)3 phase Ammeter (0-300 Amps) digital type with CT\"s of suitable ratio andinbuilt selector switch - 01 No.(e) RYBLED type indication lamp- Set of 03 |
| 103 | Outgoing(a) MCCB 4 pole 63 Amp, 25 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 03Nos(b) MCB DP 40 Amp, 10 KA \"C\" Curve,- 6 Nos |
| 104 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type LT panel of size 1200 mm height X 1100 mm width X 500 mm depth (over all dimension)confirming to IS 8623, CPRI approved, factory fabricated &factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Panel made out of suitable size angle iron, channel and fabricated from 3.00 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & includingbusbars made of pure copperduly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitableearth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories including installation of panel andframe pedestal legsmade of ISA 5050 of size 40x40x5 mm of length800 mm . 350 mmbelow the ground and 450 mm above thegoundlevel grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate).Panel shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- |
| 105 | Incoming (a) Copper strip busbar of current carrying capacity 600 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos.(b) MCCB400 Amp, 4 Pole, 415 Volts, 36 KA rating with overload, short circuitfault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 01 Nos. Make: Schneider Cat no - LV 540309/ Legrand Cat No: 422007/ Siemens, Cat: 3VA1340-4GE42-0AA0, ABB Cat No: 1SDA054478R1.(c) Digital type flush mounted 3 phase VAF + PFmeter (4110 Series) with input voltage measurement range 50-500VAC (P-P), Aux supply 30-300 Volt AC/DC, CT secondary site selectable 1-5A, Accuracy Cl-1 (d) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC - 01 set (set of three) |
| 106 | Outgoing(a) MCCB200 Amp, 4 Pole, 415 Volts, 36 KA rating with overload, short circuitfault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 02 Nos. Make: Schneider Cat no - LV 540308/ Legrand Cat No: 422006/ Siemens, Cat: 3VA1332-4GE42-0AA0, ABB Cat No: 1SDA054477R1.(b) MCCB160 Amp, 4 Pole, 415 Volts, 36 KA rating with overload, short circuitfault protection 3 phase, Ics = 100% of Icu and shall have roto operative double break mechanism along total break time less than equal to 10 ms with Spreader terminal of both end side - 03 Nos. Make: Schneider Cat no - LV 540308/ Legrand Cat No: 422006/ Siemens, Cat: 3VA1332-4GE42-0AA0, ABB Cat No: 1SDA054477R1. |
| 107 | Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved , junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.(a)Alluminium bus bar of size 50 mm X 6 mm X 400mm long wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos.(b)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 108 | S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size150 to 185sqmm,complete all as specified and directed. |
| 109 | S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,complete all as specified and directed. |
| 110 | S & F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,complete all as specified and directed. |
| 111 | Supply and fixingLT cable sleeves with colour coding (Red, Yellow, Blue and Black ) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 10 sqmm to 25 sqmm all as specified and directed by Engineer-in-Charge. |
| 112 | Supply and fixingLT cable sleeves with colour coding (Red, Yellow, Blue and Black ) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 35 sqmm to 50 sqmm all as specified and directed by Engineer-in-Charge. |
| 113 | Supply and fixing AlLugs long barrel size 16 Sq mm all as specified and directed |
| 114 | Supply and fixing AlLugs long barrel size 35 Sq mm all as specified and directed |
| 115 | Supply and fixing AlLugs long barrel size 50 Sq mm all as specified and directed |
| 116 | Supply and fixing AlLugs long barrel size 95 Sq mm all as specified and directed |
| 117 | M&Lfor precast cement concrete RCC (1:2:4 type B-1 route indicator of size 150x150x600mm with 8 mmdia steel einforcement @ 100 c/cboth ways duly engraved \" LT CABLE/LT JOINT /FEEDER NO \" with two coats synthetic enamel paint first quality fixd with (PCC 1:3:6) below ground level of size 30x30x300mm complete all as specified and directed.Note : Quoted unit rate is deemed to be included the necessary cost of excavation, returning filling and removal etc. |
| 118 | M&L for taking out and shifting the allLT Panel , Feeder Pillar Box, Junction Box not in proper ground space for workingand providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables and commissioning the panelallasspecified and as directed.Note : No extra cost for PCC, Excavation of Looping cable should be paid to the contractor separately. |
| 119 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 1,04,686.00 (refer Sch of credit). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |