| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 3 | 3x2.5 sq.mm |
| 4 | 3x4 sq.mm |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required |
| 6 | Supplying and fixing of following sizes of mediumclass PVC conduit /batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 7 | 25 mm |
| 8 | 20 mm |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq.mm |
| 10 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 11 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 12 | Supplying and fixing 63 amps , four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Supply, installation, testiing and commissioning of 150 watts , LED downlighter, commercial grade, 220-240V, 50 Hz complete i/c all accessories etc. recesses mounted including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc. as required. Make Philips, Model No. Green Perform sleek G2 CAT No. DN296B LED 15S-6500 PSE WH S2 or equivalent Model of Thorn/ Trilux |
| 14 | Supply, installation, testiing and commissioning of pre wired, 150 watts , street lightdelivering 120 lumen/ watts, IP66 Protection, PDC housing and high impact resistance (IK07) glass cover luminaire 220-240V, 50Hz on existing street light pole/ wall including all accessories and connection etc. as required. Equivalent to Philips make CAT No. BRP335 LED 18 CW R5C FG PSU S1 V1 or equivalent model of Thorn/ Trilux |
| 15 | Supply, installation, testing and commissioning of One LED tube 16.5 watts complete as required incluiding making connection etc. as required at site. (Philips make CAT No. MAS LED tube 1200mm HE 16 5W 865 T5) |
| 16 | Supplying, fixing and laying of one number PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the same etc. as required. . |
| 17 | 4x16 sq.mm |
| 18 | Supply, installation, testiing and commissioning of 12 inch heavy duty AC sinlge phase 230Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening including making good the damaged, cable connection etc. as requied 12\" exhaust fan |
| 19 | Supply, installation, testiing and commissioning of 1.5 HP borewell submersible pump suitable for 100 mm dia.Borewell submesible pump suitable for 100 mm dia. Bore having head (145-45) meter flow rate (0-52) LPM, single phase, 230V, 50Hz with control panel making of cable termination etc. complete as required. make Kirloskar, CAT No. KP4 Jalraaj UVA 30-1520 CP or equivalent model of KSB/ Grundfos/ Mody/ Crompton/CRI /Beacon/ ABB/ Xylem |
| 20 | Supplying of one number of PVC insulated and PVC sheathed/ XLPE copper conductor unarmoured powre cable of 650/1100 KV grade of size 3c X 4 sqmm etc as required. |
| 21 | Cleaningofborewelt fromall kinds ofsoil/sandforalldepth,including liftup and laydown of pump set, lowering of cleaning tools, bailing ouit water, disposal of surplus, soil, providing and fixing of necessary structure for chain pully detection of water leakage, replacing of nut bolts if any etc. as required at site. |
| 22 | Supply,installation, testing andcommissioningof1 HP. direct onfine starter with sheet steel enclosuressuitable for 1-phase, 220v , complete set with contractor & OLR , start, stop push button with indicator lamps, voltmeter,ammeter,includingmountingarrangementofstarterwithaft accessoriesetc. as required.MakeHavells UREA-OOL submersiblepump controller ‹standard)- 1 Phase , Cat No. IHAOOAJ1FD or equivalent model of Crompton/ BCH Electric |