| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. Make-L&T/Finolex/Polycab |
| 4 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 2 X6sq. mm + 1 X 6 sq. mm earth wire |
| 7 | 4 X 10sq. mm + 2 X 6 sq. mm earth wire |
| 8 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. Make-L&T/LEGRAND/ABB |
| 10 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Make-L&T/LEGRAND/ABB |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make-L&T/LEGRAND/ABB |
| 12 | Supplying & fixing suitable size GI/PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Make-L&T/LEGRAND/ABB |
| 13 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required. (But without MCB/RCCB/Isolator) |
| 14 | 8 way (4+24), Double door |
| 15 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 16 | 4 way (4+12), Double door |
| 17 | 8 way (4+24), Double door |
| 18 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 19 | 200 A,36KA,FP MCCB |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 21 | Single Pole |
| 22 | Double pole |
| 23 | Triple Pole MCB 63 A |
| 24 | Supply, Installation ,testing & Commisionioning (SITC) of outdoor CPRI certified cubical Feeder pilar with EC grade Al busbar capacity 630Amp. 100% netural suitable >25ka for 3 sec for fault level ,compatiable for following incoming & outgoing . Custum built self fabricated out of 16SWG , CRCA sheet Foot mounted type Panel Furnished with siemen gray shade powder coated paint after necessary pre treatment fully dust & vermin proof, Copper wire, Lugs and Netural & Insulating Material Engineering and Labor Charges ,Panle size (H-W-D)mm. Details asIncoming-SFU400 Amp. 2 nos. & 6 nos-HRC fuse, Incomer All Busbar capacity 500 Amp. Phase indicating light shall be protected by 6 amps MCB\"s. - 3 Sets, AVF Meter - 01 No Outgoing Deatils TP MCCB-100 Amp. 5 Nos,(Range 40A -630A , Protaction against overload, and short circuit), 0-24 hours Astronomical timer auto / manual by pass selector switches Cubicle Type 1 nos. Note-MCCB Make- Legrand/L&T/Seimens/Schneider |
| 25 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 26 | 200 A TP&N |
| 27 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 28 | 95 sq. mm |
| 29 | 120 sq. mm |
| 30 | 2 X 185 sq. mm |
| 31 | Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 32 | 120 sq. mm |
| 33 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 34 | 3½ X 95 sq. mm |
| 35 | 3½ X 120 sq. mm |
| 36 | 3½ X 185 sq. mm |
| 37 | Four Pole MCB 40/63 A Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 38 | Double Pole Enclosure Metal Box |
| 39 | Four Pole Enclosure Metal Box |
| 40 | Supplying ,fixing Connecting & Testing ,36W LED batten Make-Philips/Syska/Wipro/CG |
| 41 | Supply & Installation of 2X2 pure 36W LEDfalse ceiling Surface LightMake-Phillips/Wipro/CG/Polycab |
| 42 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation withregulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019fani/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor singlecorecableandearthingetc.asrequired. |
| 43 | 1400mm,service value≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 44 | Supplying and fixing of 230VAC 1Ph.300 mm ,900 rpm Wall Fan Make-ORIENT/CG/USHA/Bajaj |
| 45 | Supplying and fixing of 230VAC 1Ph.Two module steeped type fan electronic regulator |
| 46 | Supplying and fixing of 230VAC 1Ph. 300 mm exhaust Fanwith sweep feature. (Make: Usha / ORIENT / CG) |
| 47 | Supplying ,fixing Connecting & Testing ,20W Compact Mirror Light Make-Philips/Syska/Wipro/CG |
| 48 | Supplying,Cutting of huck , painting and fixing ofMS Down conduit forinstallation of ceiling fan upto 5 to 8 feet |