| 1 | Single pole MCB |
| 2 | 6 Amp, 1P, 230/240V AC,50/60 Hz, Breaking Capacity 10kA or 15kA, DIN Rail mounting, Electrical: 10,000 ops / Mechanical: 20,000 ops,OT −5°C t+55°C, IP20 or higher, IEC 60898 or IS/IEC 60898-1 , Cat No. (M/s L&T) C-curve (For Reference only)- BB10060C |
| 3 | 10 Amp, 1P, 230/240V AC,50/60 Hz, Breaking Capacity 10kA or 15kA, DIN Rail mounting, Electrical: 10,000 ops / Mechanical: 20,000 ops, OT −5°C t+55°C, IP20 or higher, IEC 60898 or IS/IEC 60898-1 , Cat No. (M/s L&T) C-curve (For Reference only)- BB10100C |
| 4 | Double Pole MCB |
| 5 | 16 Amp ,2 pole, 230/400V AC, rated current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, double pole isolation, manual switch operation, DIN rail mounting, IEC 60898-1 , Cat No. (M/s L&T) C-curve (For Reference only)- BB20160C |
| 6 | 32 Amp, 2 pole, 230/400V AC, rated current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, double pole isolation, manual switch operation, DIN rail mounting, IEC 60898-1, Cat No. (M/s L&T) C-curve (For Reference only)- BB20160C |
| 7 | Three Pole MCB |
| 8 | 20 Amp, 3 pole, 400V AC, current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases, manual switch operation, DIN rail mounting, IEC 60898-1 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- BB30200C |
| 9 | 32 Amp,3 pole, 400V AC, rated current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases, manual switch operation, DIN rail mounting, IEC 60898-1 compliant, Cat No. (M/s L&T) C-curve (For Reference only)- BB30320C |
| 10 | 63 Amp, 3 pole, 400V AC, rated current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases, manual switch operation, DIN rail mounting, IEC 60898-1 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- BB30630C |
| 11 | 125 Amp, 3 pole, 400V AC, rated current, 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases, manual switch operation, DIN rail mounting, IEC 60898-1 compliant, Cat No. (M/s L&T) C-curve (For Reference only)- AU15S31253C |
| 12 | Four Pole |
| 13 | 16 Amp, 4 pole, 400V AC (3 phase + neutral), 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases and neutral, manual switch operation, DIN rail mounting, IEC 60898-1 compliant, Cat No. (M/s L&T) C-curve (For Reference only)- BB40160C |
| 14 | 32 Amp,32 AMP 4 pole, 400V AC (3 phase + neutral), 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases and neutral, manual switch operation, DIN rail mounting, IEC 60898-1 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- BB40320C |
| 15 | 63 AMP 4 pole, 400V AC (3 phase + neutral6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases and neutral, manual switch operation, DIN rail mounting, IEC 60898-1 compliant, Cat No. (M/s L&T) C-curve (For Reference only)- BB40630C |
| 16 | 125 Amp, 125 AMP 4 pole, 400V AC (3 phase + neutral), 6kA or 10kA breaking capacity, B/C/D tripping curve, overload protection, short-circuit protection, simultaneous disconnection of all three phases and neutral, manual switch operation, DIN rail mounting, IEC 60898-1 compliant, Cat No. (M/s L&T) C-curve (For Reference only)- AU15S41253C |
| 17 | MCCBs |
| 18 | Three Pole MCCB |
| 19 | 160 Amp, 3 pole, 415V AC, 160A rated current, 25kA to 50kA breaking capacity, adjustable thermal and magnetic trip settings, overload protection, short-circuit protection, earth fault protection (optional), manual or motorized operation, trip indication, panel mounting, IEC 60947-2 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- cm921570000AG |
| 20 | 250 A, 3 pole, 415V AC, 250A rated current, 36kA to 65kA breaking capacity, adjustable thermal and magnetic trip settings, overload protection, short-circuit protection, earth fault protection (optional), manual or motorized operation, trip indication, panel mounting, IEC 60947-2 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- cm921560000AG |
| 21 | 400 A, 3 pole, 415V AC, 400A rated current, 36kA to 70kA breaking capacity, adjustable thermal and magnetic trip settings, overload protection, short-circuit protection, earth fault protection (optional), manual or motorized operation, trip indication, panel mounting, IEC 60947-2 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- cm930020000AG |
| 22 | Four Pole |
| 23 | 250 A, 4 Pole, 415V AC (3 phase + neutral), 250A rated current, 36kA to 65kA breaking capacity, adjustable thermal and magnetic trip settings, overload protection, short-circuit protection, earth fault protection (optional), manual or motorized operation, trip indication, panel mounting, IEC 60947-2 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- cm921560000AG |
| 24 | 400 A, 4 Pole , 415V AC (3 phase + neutral), 400A rated current, 36kA to 70kA breaking capacity, adjustable thermal and magnetic trip settings, overload protection, short-circuit protection, earth fault protection (optional), manual or motorized operation, trip indication, panel mounting, IEC 60947-2 compliant , Cat No. (M/s L&T) C-curve (For Reference only)- cm921560000AG |
| 25 | Four Pole RCCB |
| 26 | 4 Pole RCCB, In 63A, Ivn - 300mA, Im-630A, Inc 6000A, Un 415VAC Please Enable Macros to View BoQ information |