| 1 | Supply, Installation, Testing & Commissioning of Interactive flat Touch Display 75 inch, Resolution : 3840 x 2160 pixels, Display brightness : 350 nits, contrast ratio : 5000: 1, Response Time : 8ms, Viewing angle : Horizontal 178 degree Verticle 178 degree, Backlight life : 30000 hrs, Direct LED Backlight technology : LED, Aspect ratio : 16: 9, Operating system compatibility Android & OPS, Storage of android : Minimum 32 GB ROM, 3 GB RAM or better, Touch Point : 20 Points Touch, Inputs : 2 x HDMI, 1 x VGA, AV IN x 1 , USB 3.0 x 3, Inbuilt 2 Speakers 20 to 30 Watt (10w to 15w x 2), Preloaded complete with accessories and Mounting Arrangement complete etc as reqd. (Samsung/LG/VIVETEK (Delta) |
| 2 | Supply, Installation, Testing and Commissioning of All in One desktop computers as per following specifications Make : HP / DELLModel HP All-in-One - 22-c0015in or equivalent >> Operating system - Windows 10 Home Single Language 64. >> Processor - Intel® Core™ i5-8400T (1.7 GHz base frequency, up to 3.3 GHz with Intel® Turbo Boost Technology, 9 MB cache, 6 cores). >> Memory - 4 GB DDR4-2400 SDRAM (1 x 4 GB). >> Memory slots - 2 SODIMM. >> Hard drive description - 1 TB 7200 rpm SATA. >> Storage type. - HDD. >> Optical drive - DVD-Writer. >> Graphics - Intel® UHD Graphics 630. >> Audio features - Dual 2 W speakers. >> Webcam - HP Privacy HD Camera with dual array digital microphone. >> Pointing device - Wireless Optical Mouse. >> Keyboard - Wireless Keyboard with volume control. >> Network interface - Integrated 10/100/1000 GbE LAN. >> Wireless - 802.11a/b/g/n/ac (1x1) Wi-Fi® and Bluetooth® 4.2 combo. |
| 3 | Supplying, installation, testing and commissioning of Audio Podium of Jetwhite colour (powder coated) made up of CRCA body stable floor standing base compact can be fixed on floor with brackets (if possible) complete with specification & features.Specification:-Power Supply : 230v/50Hz - 110V/60HzPower Consumption : 100 WFrequency response : 100Hz - 16000Hz Output power : 60 WInput Sensitivity : MIC 1: 50dB 2dB/680ohm MIC 2:55dB 2dB/600ohm Wireless Mic: 20dB 2dB/50 ohm Aux:20DB 2dB/10K ohmRecord Output : IV/OdBQuality Control : Bass: 10DB/treble: 10dBTransmission distance: 15-30MDimensions : 580(L) x 420(W) x 1100 (H) mm |
| 4 | Features:-* Built-in 3 subwoofers, loudspeaker, One tweeter with 60 W rated output* Gooseneck microphone* LED Reading lamp* With two VHF handheld wireless mic with range 15-20M* Button ON/OFF* Built - in Control Panel* Smart & Robust design* 1 AUX input independent Control* Short circuit clipping and hight temp protection* 24 V phantom power* 3 MIC input independent control |
| 5 | SITC of IP Bullet/Dome Camera with 2MP HD resolution IP67, IK10 IR Fully configurable H.265 multistreaming; 1080p and Built-in IR illuminator with 30 m viewing distance, Cyber Security Video encryption; configuration encryption; Digest; WSSE; account lockout; security logs; gen- eration and importing of X.509 certification; HTTPS; trusted boot; trusted, Back Light Compensation BLC / HLC / DWDR, Video Compression H.265/H.264+/H.264/H.264, Image Sensor 1/2.8” 2MP Progressive scan CMOS (0.9071 cm),with memory slot, complete with 128 GB SD card Effective Pixels 1920 (H) x 1080 (V), Minimum Illumination [email protected], ISO 9001, ISO 14001, ISO 27001, CMMI 5, BIS, GDPR and Cyber Security certified etc complete as reqd. |
| 6 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS(Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. |
| 7 | 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IPneed.13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720,1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page |
| 8 | 24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarmoccurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to oneavi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis,crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. |
| 9 | 29) Built-In Artificial Intelligence: NVR should havebuilt-in AI :-- 2 Channel face detection and recognition, - Minimum4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis,crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. |
| 10 | 35) General AI Based Search: Search Pictures by channel, time, event type, target classification (FallDetection, People Approach Detection, People No. Exception Detection, People Staying Detection,Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics08 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen:1/4/8/9 |
| 11 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk withupto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATAInterface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, ULCertifications. 4 TB |
| 12 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. 1 Run of cable |
| 13 | Supplying of LED TV (Smart TV) UHD 4K |
| 14 | 32\" (Only HD) |
| 15 | Supplying and fixing of following sizes of 25 MM PVC conduit(Medium Duty ISI) along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-. |
| 16 | Supply Installation Testing and Commisioning of 3X 1.5 sqmm FRLS Power Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | Supply Installation Testing and Commissioning of Wall Mount Rack having Fixed Structure with0.8mm CRCA Sheet, completely knocked-downcondition (CKD) Shape, Vertical Mounting Rail 1.6mm. 6U Rack |
| 18 | Online UPS - Input supply: Single Phase, Output Supply: Single Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS)system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include aRectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not beless than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA,SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitableisolation transformer for additional protection against neutral faults etc. The UPS systems shall beMicroprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)\"s both forthe rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design,manufacturing and inspection process should confirm to the relevant Inter-national standards suchas IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linearloads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be< 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to beinclude to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shallbe kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor |
| 19 | loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and deliveringoutput AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overloadcapacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relativehumidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Undervoltage, over voltage, abnormal output voltage, battery over charging, output over current, shortcircuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be aVoltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPSshould be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port openprotocol for BMS integration as per approved by Engineering in charge. Required battery racks, DCbreaker of suitable rating and interconnecting copper conductor cable of suitable size andconnectors and all required accessories are inclusive in the cost. The UPS should have QRcode which should contain drawing, test report OEMmanual, Geo- Tag of manufacturing location etc |
| 20 | CAMC for CCTV 03 years after Defect liability period of 01 year |
| 21 | Providing and Fixing Cyclorama Screen in Plastic Material. The screen to be fixed on tubular frame made out of 40mm dia MS pipe and Cross MS Pipe 25mm etc as required |
| 22 | Supplying & fixing of Projector Sony VPL EX 570 |
| 23 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 24 | Copper Patch Cords of length 1m (3ft) |
| 25 | Copper Patch Cords of length 3m (10ft) |
| 26 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 27 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 ormore MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 AcessControl entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUSdatabase, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication,Government of India etc. complete as required. |
| 28 | 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting802.3at PoE+. |
| 29 | Router with Antenna |
| 30 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVCinsulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling asrequired.(Group A) |
| 31 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. |
| 32 | 1 x 1.5 sq. mm |
| 33 | 3 x 1.5 sq. mm |
| 34 | 3 x 2.5 sq. mm |
| 35 | 3 x 4 sq. mm |
| 36 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 37 | 5/6 A switch |
| 38 | 3 pin 5/6 A socket outlet |
| 39 | 15/16 A switch |
| 40 | 6 pin 15/16 A socket outlet |
| 41 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 42 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 43 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 44 | 1 or 2 Module (75mm x 75mm) |
| 45 | 4 Module (125mm x 75mm) |
| 46 | 6 Module (200mm x 75mm) |
| 47 | 8 Module (125mm x125mm) |
| 48 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc. |
| 49 | 6 way ( 4+18), (Double door) (TPN type) |
| 50 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. |
| 51 | Single pole 6/10/16/32 Amp |
| 52 | TPN 63 Amp |
| 53 | SPN 63 Amp |
| 54 | Supplying, installation, Testing & Commissioning of 20/22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not riseabove 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm) |
| 55 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 56 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 57 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 58 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.(but without charcoal/ coke and salt ) as required. |
| 59 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. Please Enable Macros to View BoQ information |