| 1 | Dismantling of ACSR or AAC conductors from overhead PCC/steel pole Complete all as specified and directed by Engr-in-charges. |
| 2 | Supply, layingand testingelectric under ground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 Core in trenches, ducts, pipe on walls, poles Complete all as specified and directed by Engr-in-charges. |
| 3 | Taking down old unsv and supply & fixing cable jointing kit for 11 KV (Eartherd) grade cable for outdoor termination heat shrink type joint complete with jointing material and accssories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm Complete all as specified and directed by Engr-in-charges. |
| 4 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc Complete all as specified and directed by Engr-in-charges. |
| 5 | M&L for spreading, levelling in layers n exc. 25 cm thick and ramming of sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables Complete all as specified and directed by Engr-in-charges.Note :- For the purpose of payment only punned thickness will be measured. |
| 6 | Supplying and laying un-reinforced precast concrete cable cover,class HV, Type 1,flat,size 300mmx 180mm x 40mm Complete all as specified and directed by Engr-in-charges. |
| 7 | Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil each layer complete specified and directed by Engr-in-Charge. |
| 8 | Removing excavated surplus material (soils) to a distance n.exc 50 m and depostimg where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 9 | Supply and fix light grade50 mm dia GI pipe fix complete to wall , poles etc with suitable clamp for protection of cable Complete all as specified and directed by Engr-in-charges. |
| 10 | Supply and fix light grade80 mm dia GI pipe fix complete to wall , poles etc with suitable clamp for protection of cable Complete all as specified and directed by Engr-in-charges. |
| 11 | M&L for HT cable route marker complete all as specified and directed by Engr-in-Charge |
| 12 | M&L for cold mix emulsion granules road patching material in making good of road 40mm thick Complete all as specified and directed by Engr-in-charges. |