| 1 | Dismantling and Taking outL.T. under ground armored PVC/XLPE insulated and PVC/XLPE sheathed heavy duty 1100 Volts grade under ground cable ofany size with old cable cover complete all as specified and directed. |
| 2 | Taking downGI pipelaid in trenches for UG cable protectionof any sizes pipe complete all as specified and as diercted. |
| 3 | Taking down any type any breaking capacity MCCB complete all as specified and as directed. |
| 4 | Dismantling /Taking down street light PCC Pole from site of any size and description including removal ofall debris after dismantling of pole and foundation and filled with soil to make surface levelled complete all as specified and as directed by Engr-In-Charge. |
| 5 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, soft/loose soil, complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, hard/dense soil, complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Returning, filling in, including spreading , leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply and laying 80 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cableswith all fittings. laid in trenches / road or fixed along wall of poles with clamps or laid under floor and making good to match with existing adjoining surface etc for cable protection complete all specifed and directed by Engr-In-Charge. Note :-Earthwork will be measured and paidseparately) |
| 10 | Supply and laying 50 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cableswith all fittings. laid in trenches / road or fixed along wall of poles with clamps or laid under floor and making good to match with existing adjoining surface etc for cable protection complete all specifed and directed by Engr-In-Charge. Note :-Earthwork will be measured and paidseparately) |
| 11 | Supply and laying 40 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cableswith all fittings. laid in trenches / road or fixed along wall of poles with clamps or laid under floor and making good to match with existing adjoining surface etc for cable protection complete all specifed and directed by Engr-In-Charge. Note :-Earthwork will be measured and paidseparately) |
| 12 | M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth including getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing wateringfinish suraface 10 cm from top using plain cement concrete1:2:4 type B1 using 20mm graded stone aggregate finishing the surface even and smooth without using extra cement ; including removal of surplus soil complete all as specified and directed. |
| 13 | Supply and laying in trenches / along the wall / floor GI pipes medium grade of size 80 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed. |
| 14 | Supply and laying in trenches / along the wall / floor GI pipes medium grade of size 40 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed. |
| 15 | Supply and laying in trenches / along the wall / floor GI pipes medium grade of size 50 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed. |
| 16 | M&L cable jointing kitfor 1100 volts grade cable for straight through heat shrinkable typejoint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 25 Sqmm to 50 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed. |
| 17 | M&L cable jointing kit1100 volts grade cable for straight through heat shrinkable typejoint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 70 Sqmm to 95 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed. |
| 18 | S&FMCCB 415 volts grade with adjustable short circuit and over load of63 Amps, 16 KA, 3 Pole complete all as specified and directed. |
| 19 | M&L for Al bus bar chamber 63 A, 440 V, 50 Hz cubical out door type,weather proof,water proof, dust proof, including Al bus barinsulated with colour code heat shrinkable sleeves and mounted on DMC/epoxy insulatorconical type through out the lenght of bus bar,including provison for termination with incoming and out going cables.bus bar chamber mounted on MS angle iron frame duly painted including PCC 1:2:4 type B1(using 20 mm graded stone aggregate) in foundation all as specified and directed. |
| 20 | Supply and lay jointing and testing and commissioning in replacement of following size XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed. |
| 21 | 35 Sqmm 3.5 Core. |
| 22 | 25 Sqmm 4 Core. |
| 23 | 16 Sqmm 4 Core. |
| 24 | 10 Sqmm 4 Core. |
| 25 | S&F copper cable flexiblePVC insulated 3 x 2.5 sqmm single core along with earth wire. junction box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed. |
| 26 | M & L for Galvanised iron (GI ) HDG octagonal pole 6.0 meter with tapered designed single/double arm bracket of length 1.5 meter (as per site requirement) and Top dia 70 mm, bottom dia 135 mm thickness 3 mm complete withinbuilt junction box comprising of63 Amp 4 way connector , LT cable to be connected by end termination joints on each pole,MCB SPN 16 Amp , earthing link with provision ofcontinuousearth continuity conductoralong with 4 sqmm GI wire for pole, gasket packing on hole cover and including cast iron base plate 220 mmx220 mmx12 mm, finial tapr plug, J type foundation nut bolt & screws as specified by manufacturer (OEM)complete all as specified and directedNote: 1.Earth work, PCC foundation for base and RCC foundation shall be carried outas per manufacturer’s (OEM) drawing and design.The item will bemeasured and paid seperately in repective item of BOQ.2. Drawing shall be produced for verification and approval of GE before execution of work. |
| 27 | S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 28 | All as per ser item No 23.00 here-in-above but 8mm dia and over upto and including 10mm dia but as in stirrups, spaces and binders. |
| 29 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in lean concrete for foundation, filling in and mass concrete, complete all as specified and directed. |
| 30 | M&L for RCC M-25 (Design Mix) as in foundation including raft footings, foundation beams, plinth beams, bases for columns etc including necessary form work, complete all as specified and directed. |
| 31 | Supply ,fabricte & InstalledLT Distribution Panel (CPRI Approved) Pedastal type outdoor type factory fabricated made out of 3.15 mm thick CRCA Sheet , size not less than 2.0 M x 0.90 M x 1.50 M & suitable size to accommodate allaccessories/fittings,compartmentalized in construction to accommodate incomming MCCB\"s and TPN Aluminium Bus Bars of suitable capacity of 400 Amps. The TPN Bus Bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the lenth of the TPN Bus bar.The incoming as well as outgoing MCCBs shall have Aluminium extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders.The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables.All extension links/interconnection shall colour coded sleeves.The cubical shall have a bottom channel of size75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be frontopenable by double door formand shall have louvers and airvent gasket for Natural flow of airadhesive type gasket shall be used to makepanel vermin proof,and panel shall be cold Zinc (for rust proof) sprayed thicknesscomplete all as specified, Panel mounted on 50x50x5 mm sizeMS angle iron frame duly painted including PCC 1:2:4 type B1(using 20 mm graded stone aggregate) in foundation andcomprising of the following items :- |
| 32 | (i) Al bus bar 400 Amps CU INCOMER(ii) 250A 4 Pole 36 KA MCCB-1 No METERING (i) Digital Voltmeter (0-500V)-1 Nos(ii) Digital Ammeter (0-250A)-1 Nos(iii) R/Y/B Indication Lamp 1Set -1 Nos(iv) Current Transformer (200/5A) 3-Nos(v) Control fuse witth base (2/20A)-6 NosOUTGOINGChange over switch of 200 Amps rating - 1 Nos(i) 100A TPN 16 KA MCCB - 1 Nos(ii) 63A TPN 16 KA MCCB - 3 Nos(iii) 40A TPN 16 KA MCCB - 2 Nos(iv) 40A TPN 16 KA MCB - 2 Nos (v) 70A TP ML 4 Power contactor- 1 Nos(vi) 24 Hrs timer analog type (L&T) - 01 Nos |
| 33 | All per item No 27 here in before but size min 2300x1950x420mmand including the following accessories:(i) Al bus bar 600 Amps CU INCOMER(ii) 400A 4 Pole 36 KA MCCB-1 No METERING (i) Digital Voltmeter (0-500V)-1 Nos(ii) Digital Ammeter (0-200A)-1 Nos(iii) R/Y/B Indication Lamp 1Set -1 Nos(iv) Current Transformer (200/5A) 3-Nos(v) Control fuse witth base (2/20A)-6 NosOUTGOINGChange over switch of 200 Amps rating - 1 Nos(i) 160A TPN 36 KA MCCB - 1 Nos(ii) 100A TPN 16 KA MCCB - 3Nos(iii) 63A TPN 16 KA MCCB - 2 Nos(iv) 40A TPN 16 KA MCB - 4 Nos (v) 32A SPN 10 KA MCB - 4 Nos (v) 70A TP ML 4 Power contactor- 1 Nos(vi) 24 Hrs timer analog type (L&T) - 01 Nos |
| 34 | Supply and fixing LED street light fitting 35 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 35 | Supply and fixingLED street light fitting 90 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 36 | Supply and fixingLED street light fitting 120 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 37 | Supply & FixLED flood light fitting 210 Watts , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant ,Pressure die cast aluminium housing, heat resistant toughened glass with frame, uniform distribution ,includingfixing arrangmentswith angle iron and suitable nut,bolt,washer etc on wall /on pole complete all as specified and as directed. |
| 38 | Supply and fixing ofof the under mentioneditems to be incorporated in street light fittings including taking down street light from pole andrefixing it on pole after replacement of driver complete all as specified and directed:- |
| 39 | LED Driver for 1 x 60 watt LED street light complete of make -Crompton/Bajaj/Havells. |
| 40 | LED Driver for 1 x 90 watt LED street light complete of make -Crompton/Bajaj/Havells . |
| 41 | LED Driver for 1 x100 watt LED flood light complete of make -Crompton/Bajaj/Havells. |
| 42 | LED Driver for 1 x200 watt LED flood light complete of make -Crompton/Bajaj/Havells. |
| 43 | S & F in street light timer switch digital astronomical type , three phase 32 Amps , comprising of suitable capacity of contactor and MCB along withpole mountable PVC enclosure complete all as specified and directed. |
| 44 | M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI Strip 32 X 6 mm as earthing lead ,by means of bolts,nuts and washers of GIand protection by provisionof GI medium grade pipe 50 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed . |
| 45 | M&L for GI strip 32 mm X 6 mm buried in ground complete all as specified and directed. |