| Sl. No. | Item Description |
| 1 | Material and labour for checking loose connections, sparks,earth leakage etc by disconnecting and taking down the swiches /switch boards/LEDs/Fans/DBs /fixtures etc and making good by clearing the fault, making proper insulation and testinng and restoring the supply etc all as directed.Note-i) Replacement of any part such as switches, sockets, tube lights,DBs , MCBs shall be measured and paid seperately under relevent items. |
| 2 | Taking down carefully point wiring removing from site of work and making good to the disturbed surfaces of walls/floors etc all as specified and directed. |
| 3 | Taking down carefully MCB Distribution board SPN/TPN off sizes & any capacity by unscrewing from DB box, all as directed. |
| 4 | M&L Point wiring forOne light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including PVC concealed rigidconduit(ISI mark) and pressed steel terminal boxes (for mounting switches / sockets/regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm and 6cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed.Note :- (i)The wiring shall be provided in standard colour code(ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces.(iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed.(iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed. |
| 5 | All as per description of serial item No. 4.00 here in before butfor One 3-pin socket outlet 5 Amp on independent board. |
| 6 | All as per description of serial item No. 4.00 here in before but one 3 pin socket outlet 5 Amp on same board |
| 7 | All as per description of serial item No. 4.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board.with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed. |
| 8 | All as per description of serial item No. 4.00 here in before but for One industrial power socket 20 Amp on independent boardwith 4 sqmm FRLS multistranded copper cable including 4 sqmm FRLS multistranded copper cable as earth continuity wire in existing conduit connected to common earth and each terminal box/fitting complete all as specified and directed. |
| 9 | All as per description of serial item No. 4.00 here in before butin existing PVC Conduit. |
| 10 | All as per description of serial item No. 4.00 here in before butfor One 3-pin socket outlet 5 Amp on independent board in existing PVC Conduit. |
| 11 | All as per description of serial item No. 4.00 here in before but one 3 pin socket outlet 5 Amp on same board in existing PVC Conduit. |
| 12 | Taking out carefully the existing burnt sub main wiring of size 4 Sqm / 6 Sqmm PVC insulated multi stranded aluminum conductor cable along-with earth continuity conductor from the PVC / rigid steel, concealed/surface conduitcomplete all as specified and directed. |
| 13 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including concealed non metallic PVC conduit 20mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes. |
| 14 | Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including concealed non metallic PVCconduit 25mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 03 runs of 01 metre cable and 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 15 | Supply and laying sub main wiring complete with 05 runs ( 3 nos for three phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including steelmetalicconduit 25mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 05 runs of cable 01 metre 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 16 | Supply and laying sub main wiring complete with 05 runs ( 3 nos for three phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS)PVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including steelmetalicconduit 25mm dia ISI marked andaccessories surface fixedon wall /flooretc all as specified. Note:- 05 runs of cable 01 metre 01 run of PVC conduit shall be considered as one unit for measurement purposes. |
| 17 | Supply and fix as in repair Switch piano flush type single pole one way 5/6amp complete all as specified and directed.. |
| 18 | Supply and fix as in repair Switch piano flush button single pole one way 15/16 amp complete all as specified and directed. |
| 19 | Supply and fix as in repair socket piano flush type 5/6amp complete all as specified and directed.. |
| 20 | Supply and fixas in repair Socket out let2 in 1, 3 pin, 5/6 and 15/16 amp multipurpose, flush type complete all as specified and directed. |
| 21 | S&F in repair switch piano type, 5 Amp, single pole two way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge. |
| 22 | supply and fixing Bell push, flush type,5 amp 230V AC 50 Hz forcomplete all as specified and directed by Engr-In-Charge. |
| 23 | supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr-In-Charge. |
| 24 | Supply and fix as in repair Ceiling rose surface Bakelite 65 x 50 mm three terminals complete all as specified and directed. |
| 25 | supply and fix as in repairs MCB DB single pole and neutral 240 volt SPN 04 way with 200 Amps rated bus bardouble door type complete all as specified and directed.Make-IndoAsian/ Legrand/ ABB |
| 26 | All as per description of serial item No. 25.00 here in before but8 wayMake-IndoAsian/ Legrand/ ABB |
| 27 | All as per description of serial item No. 25.00 here in before but12 way Make-IndoAsian/ Legrand/ ABB |
| 28 | Supply and fix as in repairs MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed. Make- IndoAsian/ Legrand/ ABB |
| 29 | Supply and fix as in repairs ELCB SPN 40 Amps 240Volts,complete all as specified and directed.Make- IndoAsian/ Legrand/ ABB |
| 30 | Supply and fix as in repairs MCB SP 6-32 Amps 240Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed.Make- IndoAsian/ Legrand/ ABB |
| 31 | Supply and fix as in repairs MCB TPN 63 Amps 415 Volts, Breaking capacity 10 KA \"C\" curve complete all as specified and directed. Make- IndoAsian/ Legrand/ ABB |
| 32 | Supply and fixing as in repairs TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated bus bar complete all as specified and directed.Make : IndoAsian/ Legrand/ ABB |
| 33 | Supply and fixing as in repairs vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed.Make : IndoAsian(Optipro) / Legrand/ ABB |
| 34 | Supply and fixLED batten with extruded aluminiumbody and PC diffuser complete with inbuilt driver 1x20 watt including electrical connection, Cat Ref CCS-100-20-65HL2-DP-NWH of Make: Crompton Greavesor equivalent in Make-Havells/Phillips/Wipro. |
| 35 | All as per description of here in before but 10 watt Make-CROMPTONModel CSS-103-1065-SL-DP-NWH Havells/Phillips/Wipro |
| 36 | Suply and fixing in repair Lamp holder angular PVC polycrbonate type with back plate suitable for PVC casing capping/conduit fitting complete. |
| 37 | S&F as in repairs modular switch 10 Amp one way switch one module complete all as specified and directed. |
| 38 | S&Fas in repairs modular multi socket 10 Amp 2/3 pin two module complete all as specified and directed. |
| 39 | S&F as in repairsmodular switch 25 Amp one way switch one module complete all as specified and directed. |
| 40 | S&F as in repairsmodular socket 25 Amp 2/3 pin two module complete all as specified and directed. |
| 41 | S&F as in repairsmodular metal box with frame & cover and plate suitable for one module complete all as specified and directed. |
| 42 | S&Fas in repairs modular metal box with frame & cover and plate suitable for two module complete all as specified and directed. |
| 43 | S&Fas in repairs modular metal box with frame & cover and plate suitable for three module complete all as specified and directed. |
| 44 | S&Fas in repairs modular metal box with frame & cover and plate suitable for four module complete all as specified and directed. |
| 45 | S&Fas in repairs modular metal box with frame & cover and plate suitable for six module complete all as specified and directed. |
| 46 | Supply and fixing in repair metal flush box 1/2 modulecomplete all as specified and directed. |
| 47 | Supply and fixing in repair metal flush box 3 modulecomplete all as specified and directed. |
| 48 | Supply and fixing in repair metal flush box 4 modulecomplete all as specified and directed. |
| 49 | Supply and fixing in repair metal flush box 6 modulecomplete all as specified and directed. |
| 50 | S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed. |
| 51 | S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed. |
| 52 | S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed. |
| 53 | S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed. |
| 54 | S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed. |
| 55 | Suply and fixing asin repairs recessed LED Driver with input voltage 90-300 V AC , max current 0.7 A and output voltage 40-55 V for ceiling panel layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit of Make-Havells/Phillips/Wipro as directed by engr-in - charge. |
| 56 | Suply and fixing asin repairs recesse mounted 36w LED ceiling light fitting provided with best in class aesthetics premium white poeder coated frame blends seamlessy with ceiling layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit. Make-Havells/Phillips/Wipro |
| 57 | Suply and fixingasin repairs integratedLED bulk head luminaire 10 watt comprising of pressure die cast housing, acrylic diffuser & frameIP65 protection & available in 5700k (CDL) & 3000K (WW) colour temperatures pre-wired incl connection with flexible twin core wire complete all as specified and directed. Make-Havells/Phillips/Wipro |
| 58 | S&Fasin repairssheet metal enclosure single pole and neutral encolsure with two pin and earth plug and socket complete with provision for fixing of one MCB SP 20 Amps complete all as specified and directed. |
| 59 | Supply and fixingasin repairsstepped type electronic fan regulator , SP 230 Volt100/120 watt complete all as specified and directed. |
| 60 | Attending day to day complaints for ceiling fan, exhaust fan and wall mounted fans installed at various locations in AF Stn Mohammadpur and rectifying the complaints complete all as directed by Engr-in-Charge.Note : (i) Defective parts / winding required to be replacedshall be measured and paid separately under respective items. |
| 61 | Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge.Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemedto be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job. |
| 62 | Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed.Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make thefans functional. The rates quoted for the same deemed to be included for the above job. |
| 63 | Supply & fixcapacitor of 2.5 mfd complete all as specified and directed. |
| 64 | -Ditto- but 3.15mfd complete all as specified and directed. |
| 65 | -Ditto- but 4.0 mfd complete all as specified and directed. |
| 66 | Supply & fixcapacitor of 0.85/1.00 mfd complete all as specified and directed. |
| 67 | S & F heavy dutyPVC cable1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed. |
| 68 | S & Fheavy duty PVCcable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed. |
| 69 | Material and labour for fixing plastic body exhaust fan Complete with blades and motor for 250 mm sweep in replacment of old u/s platic body exhaust fan as per site requirement all as directed by Engineer-In-charge. |
| 70 | S&F ventilation fan motor suitable for 300 mm sweep metal fans having double ball bearing, heavyduty motor suitable for existing make/model complete all as specified and directed by engr-in-charge. |
| 71 | S&F ceiling fan 1250mm sweep, aerodyanamic profile blades for silent operation with high twist angles leading to high air delivery, rust free re-inforced ABS blades, dust and mark resistant caoting pearl white Stealth Air complete all as specified and directed. |
| 72 | S & Fplug top 16 Amps, 240 volts complete all as specified and as directed. |
| 73 | S & F MCCB 125 Amps,4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as directed. |
| 74 | S & F MCCB 100 Amps,4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as specified and directed. |
| 75 | M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers includingPCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note:(i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. ) |
| 76 | S & F LED Bulbs of 07 watts including taking down complete all as specified and directed. |
| 77 | S & F LED Bulbs of 09 watts including taking down complete all as specified and directed. |
| 78 | GEYSER and SOLAR HEATER |
| 79 | M&L for taking down unserviceable geyser of 25 Ltr capacity from existing position by disconnecting Elect/ water connectioions, from any position, locations and replacing the following unserviceable parts as mentioned below: - |
| 80 | (i) S&F in repairs thermostat suitable for 25 ltr storage type Vertical water heater ISI mark as per existing one complete all as specified and directed. |
| 81 | (ii) S&F in repairs LED indication lamp suitable for Geysers in roud/ rectangular shape complete all as specified and directed. |
| 82 | (iii) S&F in repairs Geyser assembly suitable to fix thermostat, heating elements as of the existng size suitable for 25 ltr capacity geyser including suitable washers, clamps with bolts & nuts suitable for 06/09 hole complete all as specified and directed. |
| 83 | (iv) S&F in repairs fusible plug suitable for 25 ltr capacity Geysers as per existing complete all as specified and directed. |
| 84 | (v) Taking down unserviceable bottom/ top cover plates (2 half) and S&F with new bottom/ top cover plates with machine coloumns of Geyser 25 ltr capacity complete all as specified and directed. |
| 85 | (vi) S&F in repairs steel water tank suitable for 25 ltr capacity water heater vertical type as per existing model and size complete all as specified and directed. |
| 86 | (vii) S&F safety plug suitable for 25 ltr capacity vertical type water heater as per existing model/ make complete all as specified and directed. |
| 87 | (viii) S&F in replacement of M S heavy duty fabricated frame suitable for holding water tank of 25 ltr capacity geyser, as per sample and existng shape and size including suitable hole for mounting the Geyser complete all as specified and directed.Note: Sample can be taken for the geyser by the contractor from concerned JE E/M sub division before quoting the rate. |
| 88 | (ix) S&F in replacement heating element 2 KW triangle type suitable for 25 ltr capacity vertical type water heater ISI mark. Make: Theeta complete all as per existing one and as directed. |
| 89 | (x) S&F glass wool heat insulation superior quality suitable for geyser ofCapacity 25/35/50 ltr complete all as directed. |
| 90 | (xi) S&F outer cover in replacement suitable for 25 ltr capacity vertical water heater as per existing model heavy duty complete all as specified and directed. |
| 91 | (xii) Supply only nuts, bolts, washers suitable of existing size and model suitable for fixing of Geyser assembly with geyser tank complete. |
| 92 | (xiii) S&F steel braided connection mesh type for HOT/ cold water supply 2\" long heavy duty ISI mark as per sample complete all as specified and directed. |
| 93 | M&L for removal and un-installation of existing solar leaked tank from the system and refixing after necessary repair to make it serviceable in all respect. |
| 94 | S&F, installation, testing and commissioning of new steel solar water heater tank of 200 litres capacity complete in replacement of existing unsserviceable/leaked solar tank with insulation and inlet and outlet connection for 6 Nosaccn and over flow pipes including all GI fittings i.e GI Socket, Elbow, Union, Plug, rubber gasket etc as required at site complete all as specified and directed. |
| 95 | M&L De-scaling of existing solar flat plate collector brazing where ever required, all fittings and gaskets in place complete all as directed. |
| 96 | S&F insulationof existing hot water line with 9mm Nitrile insulation for better performace of the solar water heater complete all as directed. |
| 97 | SITC for fresh hose pipe for the solar water heaer system from solar water tank to collectors complete all as directed. |
| 98 | Repair/Replacement of electrical back up heating element 3 KW suitable for Solar heating system including electrical connection with DB and all accessories required for smooth functioning electrical backup complete all as specified and directed. |
| 99 | S & F in replacement of Flat solar plate collector panels suitable for 100LPD solar water heater, free stand type, with copper tubings of suitable size enclosed in toughed glass from top and metal sheet base with back ground painted with black colour and PUF insulated of size as per site requirment, complete all as specified and directed by EIC. NOTE: 1) Panel should be BIS and CEC approved.2) All accessories required at site for installation is deemed to be included in quoted rate. 3) Contractor must check size of panel as per existing before procurement. |
| 100 | AC Refrigerator,Dessert cooler etc |
| 101 | M&L for servicing of Split type AC capacity 1.5 ton / 2.0 ton , cleaning of Indoor / outdoorunit, cooling /condensing coil , reinsulation of refrigeranttubing , replacement of worn out spare parts of AC & checking wiringand renewing side and straight thimble, material for soldering (LPG Gas breezing rod, breezing power), drain out pipe of required length as per site, fastner, nut bolts etc for complete all as specified and as directed.Note: Quoted rate deem to included brass nut and brass end caps, brass nuts, brass coupler nuts and brassgas refilling valve of any size and type. Worn out spare partswill be measured and paid separately under respective items of the Schedule. |
| 102 | M&L fordetecting the cause of leakage by nitrogen gas flash method or soap method in any type/capacity1.5 ton/2 Tonof AC in position and ensuring the complete system leak proof, by soldering and brazing and charging full or top up with refrigerant gas (R-22 & R-410a) with appropriate quantity as per site including testing for smooth functioning complete all as specified and as directed.Note:(i) Refillingand toping up of refrigerant (R-22 & R-410a) as required on site will be measured and paid separately under respective items of the Schedule.(ii) T&P, Nitogen (any qty) required site to work on height and soldering & brazing is deemed to be included in quoted rate.(iii) Demounting of units (indoor and outdoor) from their position or from height and refixing back at height is deemed to be included in quoted rate. Contractor has to arrange for its own labour & T&P for demounting & refixing. No extra payment will be done for demounting & refixing. |
| 103 | M&L forrewinding of the blower motor 1/6,1/5,&1/8 HP of AC any type /capacity with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed. |
| 104 | M&L for rewinding of the outdoor fan motor any type /capacity ((upto 1/13 HP, 800 rpm, 57 watt) thermally protected with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed. |
| 105 | Supply and fixing in replacement of outdoor fan Blade for AC upto 2 ton as per site, complete as directed.Note: Sample shall be checked at site before procurement to match the existing models. |
| 106 | Supply and fixing in replacement of starting relay of existing makesand capacity duly ISI marked for AC W/T and split type 1.5/2 Ton capacity as per site requirement, complete all as specified and as directed. |
| 107 | Supply and fixingin replacement of starting capacitor of existing make and capacity (40/60 & 80/100mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed. |
| 108 | Supply and fixingin replacement of three state running capacitor of existing make and capacity (50/6, 45/5 & 36/6mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed. |
| 109 | Supply and fixing in replacement of refrigerant tubing for suction /discharge of (5/8, 1/4, & 1/2 )including insulation tubing all as per site requirement and as directed by Engr-in-Charge. |
| 110 | Supply and fixing in replacement of of capacitor 10 Mfd blower motor ISI marked complete all as specified and as directed. |
| 111 | S&F in replacement ofPCB card, board type/box type (2 PCB cards fabricated in one box) suitablefor existing split type AC 1.5/2 ToneAC of any make/model complete all as specified and as directed. |
| 112 | S&F in replacement of cooling coilofindoor split type AC 1.5/2.0 Ton capacity complete all as per existingmake and model |
| 113 | Supply and fixing in replacement of Split AC Remote (for any make AC)as per model on site.Note: Sample shall be checked at site before procurement to match the existing models. |
| 114 | M&L and T&P (any type) for shifting of Split AC of any capacity both indoor, outdoor & its connected accessories (like drain out pipe, copper tubing, frame etc.) by properly demounting from one location and re-fixing it in other location as per user requirement including cutting hole and removing old copper pipes and using same for the new location and testing/commisioning after making proper connectionsby deploying sufficient labour and tool, complete all as specified and directed by EIC.Note:- (i) Any type of civil work involve in shifting is deemed to be included in quoted rate.(ii) Shifting can be on same floor or to higher floors or any other location, no extra payment will be made for labour and transportation.(iii) Cost ofrefrigerant gas charging of unit (full or top up) is deemed to be included in quoted rate.(iv) Any extra item required at site due to difference in location will be measured in relevant item. |
| 115 | S& F Rotary compressor suitable for 2TR Split AC all as per site requirement. |
| 116 | S& F Rotary compressor suitable for 1.5TR Split AC all as per site requirement. |
| 117 | M&L for servicing/detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 80/40 ltr, 120/40 Ltr, & 150/150 Ltrs complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) Refillingand toping up of refrigerant (type and quantity) as required on site is deemed to be included in quoted rate. |
| 118 | Supply and fixing in replacement of compressor reciprocating type (hermetically) sealed suitable for capacity 80/40, 120/40, 150/150 litre water cooler completeall as specified and as directed.Make: Emerson/Hitachi/LG |
| 119 | Supply and fixingin replacement of thermostat switch suitable for existing of water cooler any make and capacity complete all as specified and as directed.Make:Renutrol/Indofos/Annapurna/Totaline |
| 120 | Supply and fixing starting relay and overload relay suitable for existing size and make of water cooler complete all as specified and as directed.Make: Epcos/Asian |
| 121 | Supply and fixing in replacement of starting capacitor for water cooler of suitable for existing size & make of water cooler complete all as specified and as directed. |
| 122 | Supply and fixing running capacitor suitable for existing size & make water cooler complete all as specified and as directed. |
| 123 | Supply and fixing drier/filter of suitable capacity, complete all as specified and directed. |
| 124 | Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge asapproved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed. |
| 125 | S&F in replacement of of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed. |
| 126 | Repair and maintenance of refrigerator of any capacity capacity including replacement of following unserviceable parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, Door opening handle - 01 Set, freezer chamber - 01 No, Door panel complete - 01 set, thermostat switch - 01 No, vegetable tray-01 No, Door rubber beeding set - 01 Set, ice tray - 02 Nos. Testing and commissioning of refrigerator after repair in its original location all as specified and directed. |
| 127 | Supply and labour for charging of Refrigerant gas R-22 in cooling appliances of any type and capacity, complete all as specified and directed.Note: Labour cost for charging is deemed to be included in quoted rate. Since R-22 is flammable & exposive gas, contractor has to make sure for the safety and take adequate safety measure for technicians/ labour during charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor. |
| 128 | Supply and labour for charging of Refrigerant gas R- 410a in cooling appliances of any type and capacity, complete all as specified and directed.Note: Labour cost for charging is deemed to be included in quoted rate. Since R-410a is high pressure & exposive gas, contractor has to make sure for the safety and take adequate safety measure and suitable tools for technicians/ labour during/for charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor. |
| 129 | Dittoas aboveitem No 49 but Refrigerant gas R- 32 in inverter type Split ACand any capacitycomplete all as directed |
| 130 | Supply and labour for charging of Refrigerant gas R-134 a in cooling appliances of any type and capacity,refrigerater,water cooler & deep freezercomplete all as specified and directed.Note: Labour cost for charging is deemed to be included in quoted rate. Since R-134 a is high pressure & exposive gas, contractor has to make sure for the safety and take adequate safety measure and suitable tools for technicians/ labour during/for charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor. |
| 131 | M&L for visiting of Technician on site and checking, inspecting & detecting fault in AC\"s, Deep Freezers, Water coolers & refrigerators of any capacity, type, any make & model by technicians and rectifying minor defects on site and noting down material required to make cooling appliance functional in next visit.Note: (i) Spare required will be measured saperately.(ii) Servicing visit will not be measured under this item. |
| 132 | M&L for servicing of room desert cooler of any make size by cleaning, oiling & greasing, checking of defects and rectifyingunserviceable switches, control switch etc adjusting and setting for workincluding complete electric wiring with 3 core flexible cable plug top and testing complete all as specified and as dirceted by Engr-in-Charge. |
| 133 | M&L for rewinding of fan motor of desert cooler with super enamelled copper wireof existing gauge or gauge as approved by Engineer-in-Charge complete all as specified and as directed.Note: replacement of bush bearing is deemed to be included in quoted rate. |
| 134 | M&L for replacement of tullu pump submersible type for desert cooler having, 2mtrs head, 500l/h discharge rate, 25 watts, single phase, complete all as specified and as directed. |
| 135 | Supply and fix in replacement of New fan motorof 120W, 220 Volts AC, copper winding, Class E insulation, 1500 rpm, steel shaft, including capacitor of 4 mfd for desert coolers complete all as specified and as directed.Note :- The contracter shall provide warranty period of 1 year from the date of replacement. |
| 136 | Supply and fixingin replacement of capacitor 4 Mfd blower motor & desert cooler motor ISI marked complete all as specified and as directed. |
| 137 | M&L for plastic distributor 3 way of superior quality as per site requirement complete all as specified and as directed. |
| 138 | M&L for PVC pipe 15 mm dia for desert cooler for inside connection of superior quality complete all as specified and as directed. |
| 139 | S&F desert cooler grasspad suitable for cooler of capacity 4000 cum/hrs & dimension of pad not less than complete all as sepcified and directed. |
| 140 | M&L for painting of cabinet body of room cooler withone coat of red oxide paint and two coats for desert cooler water tank with black enameled paint and outer body with smoke grey paint after preparation of surface complete all as specified and as directed. |
| 141 | Water supply |
| 142 | Taking up or down CI Pipesincluding all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes :- |
| 143 | (a) 80mm bore |
| 144 | (b) 100mm bore |
| 145 | (c ) 150mm bore, |
| 146 | (d) 200mm bore |
| 147 | Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of followingsizes :- |
| 148 | (a)80mm bore |
| 149 | (b) 100mm bore |
| 150 | (c ) 150mm bore |
| 151 | (d)200mm bore |
| 152 | Laying,refixingand Testing of Oldcast iron pipes with , in any length, laid in trenches complete all as specified and directed of followingsizes :- |
| 153 | (a)80mm bore |
| 154 | (b) 100mm bore |
| 155 | (c ) 150mm bore |
| 156 | (d)200mm bore |
| 157 | Taking up or down steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 158 | (a) 15mm bore |
| 159 | (b) 20mm bore |
| 160 | (c ) 25mm bore |
| 161 | (d) 40mm bore |
| 162 | (e) 50mm bore |
| 163 | (f)80mm bore |
| 164 | (g) 100mm bore |
| 165 | S & F in repair steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 166 | (a) 15mm bore |
| 167 | (b) 20mm bore |
| 168 | (c ) 25mm bore |
| 169 | (d) 40mm bore |
| 170 | (e) 50mm bore |
| 171 | (f)80mm bore |
| 172 | (g) 100mm bore |
| 173 | Laying & refixingonly in repair steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 174 | (a) 15mm bore |
| 175 | (b) 20mm bore |
| 176 | (c ) 25mm bore |
| 177 | (d) 40mm bore |
| 178 | (e) 50mm bore |
| 179 | (f)80mm bore |
| 180 | (g) 100mm bore |
| 181 | S & F in replacement Gun metal Gate valvewith iron wheel headscrewed both ends complete all as specified and as directed by the Engineer-in-Chargeof sizes :- |
| 182 | (a) 40 mm dia |
| 183 | (b)50 mm dia |
| 184 | (c ) 20 mm dia |
| 185 | (d)25 mm dia |
| 186 | S & Fcheck valve heavy duty of gun metal both end threaded and leaf spring loaded vertical typeincluding removing unserviceable foot valvefrom the suction pipe of the pump setcompleteall as specified and directed by Engr in chargeof following sizes:- |
| 187 | (a) 100 mm dia |
| 188 | (b) 80 mmm dia |
| 189 | (c) 50 mm dia |
| 190 | S & F in replacementCI non return valve completeall as specified and directed by Engr in charge of following sizes :- . |
| 191 | a) 150 mm dia |
| 192 | b) 100 mm dia |
| 193 | c ) 80 mmm dia |
| 194 | d) 50 mm dia |
| 195 | M & L for Cutting existing CI orsteel tubing of any sizefor alterations or additions and screwing all as specified and directed by Engg-in-charge |
| 196 | Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:- |
| 197 | (a) 900mm x 750mm x 900mm |
| 198 | (b) 900mm x 600mm x 1000mm |
| 199 | S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) completeall as specified and directed by Engr in charge includingtaking down the oldworn out sluice valve completeall as specified and directed by Engr in charge for the following sizes :- |
| 200 | (a) 150 mm dia |
| 201 | (b) 100 mm dia |
| 202 | (c ) 80 mm dia |
| 203 | M&L for earthling complete with galvanised iron earth plate electrode of the size 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm by means of bolts ,nuts.chuck nuts and washers of galvanised iron or .steel watering pipe of 20 mm bore , galvanised iron medium grade of 40 mm bore galvanised iron light grade of earth wire protection including all excavation earth work in any type of soil ,PCC pit with RCC pit cover , charcoal,salt,funnel complete all as shown in electrical plate No-3 of SSR Part-I & Testing on completion. Note: Quoted rates shall be including for earth strip with protection pipe upto 7.5 mtr length. |
| 204 | M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge. |
| 205 | (a) 80 mm |
| 206 | (b) 100 mm |
| 207 | ( c ) 150mm |
| 208 | (d) 200 mm |
| 209 | M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line. |
| 210 | (a)200/150 mm dia |
| 211 | (b)100/80 mm dia |
| 212 | S&F cable copper flexible 3 Core cicular type 2.5 sqmm heavy duty complete all as specified and directed. |
| 213 | S&F cable copper flexible 3 Core cicular type 4 sqmm heavy duty complete all as specified and directed. |
| 214 | S & F heavy dutyPVC cable1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed. |
| 215 | S & Fheavy duty PVCcable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed. |
| 216 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complte all as specified and directed. Note:- (i) Serviceable bricks shall be stacked for reuse and Old unservicable bricks shall be sold to contractor under Sch of credit. (ii) Existing sand cushioning shall not be removed.(iii) In case different strata is met with during excavation, contractor shall not claim extra on this account. |
| 217 | Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed. |
| 218 | M&L Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail