| 1 | 3.1 Repair Rewinding of Submersible motor includes full servicing and rewinding (wherever required) as per manufacturer s specification and to the satisfaction of Engineer Incharge. It includes the replacement of minor parts such as bushes (oil seal bush) Nut Bolts, washers, cable seal, gland ring, vent plug, water drain plug, etc. complete job3.1.3 Above 5HP to 7.5 HP V-6 |
| 2 | 3.1 Repair Rewinding of Submersible motor includes full servicing and rewinding (wherever required) as per manufacturer s specification and to the satisfaction of Engineer Incharge. It includes the replacement of minor parts such as bushes (oil seal bush) Nut Bolts, washers, cable seal, gland ring, vent plug, water drain plug, etc. complete job3.1.4 Above 7-5 HP to 10 HP V-6 |
| 3 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.1 Providing & fixing of GM neck rings parts on impeller. 3.3.1.1 Plain Type V-6 |
| 4 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.1 Providing & fixing of GM neck rings parts on impeller. 3.3.1.2 Bowel typeV-6 |
| 5 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.2 Providing & Fixing of GM/SS bush per piece 3.3.2.1 Plain Type V-6 |
| 6 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.2 Providing & Fixing of GM/SS bush per piece 3.3.2.2 Bowel typeV-6 |
| 7 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.3 Providing & replacement of G.M. Impeller 3.3.3.1 Plain Type V-6 |
| 8 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.3 Providing & replacement of G.M. Impeller 3.3.3.1 Bowel Type V-6 |
| 9 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.4 Providing & replacement of Nylon Impeller 3.3.4.1 Plain Type V-6 |
| 10 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.4 Providing & replacement of Nylon Impeller 3.3.4.1 Bowel Type V-6 |
| 11 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.5 Providing & fixing CI Diffuser/ guide vans per piece 3.3.5.1 V-6 |
| 12 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.7 Providing & fixing Nylon Diffuser/ guide vans per piece 3.3.7.1 V-6 |
| 13 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.8 Providing & fixing Microlone Guide per piece 3.3.8.1 V-6 |
| 14 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.9 Providing & fixing of CI body per piece 3.3.9.1 Plain Type V-6 |
| 15 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.9 Providing & fixing of CI body per piece 3.3.9.1 Bowel Type V-7 |
| 16 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.10 Pump opening & fixing including machining & all finishing work for desired performance 3.3.10.1 Plain Type V-6 |
| 17 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.10 Pump opening & fixing including machining & all finishing work for desired performance 3.3.10.1 Bowel Type V-7 |
| 18 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.11 Impeller welding & turning (if not replaced) 3.3.11.1 Plain Type V-6 |
| 19 | 3.3 Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. 3.3.11 Impeller welding & turning (if not replaced) 3.3.11.1 Bowel Type V-7 |
| 20 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Above 5 HP and up to 10 HP |
| 21 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 6.0 Sq.mm Please Enable Macros to View BoQ information |