| 1 | Wiring for light point/Fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable recessed medium class PVC conduit with modular type switch, modular plate, suitable GI box and with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required group B |
| 2 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc as required |
| 3 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 A& 15/16A modular socket outlet and15/16 A modular switch connections etc as required |
| 4 | Supplying and fixing 5 A to 32 A rating 240/415 V 10 kA C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required single pole |
| 5 | Supplying and fixing 5 A to 32 A rating 240/415 V 10 kA C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required double pole |
| 6 | Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x4 sqmm +1x4 sqmm earth wire |
| 7 | Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x2.5 sqmm +1x2.5 sqmm earth wire |
| 8 | Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 2x10 sqmm +1x6 sqmm earth wire |
| 9 | Wiring For circuit /Submain wiring alonwith earthwire the following sizes of FRLS PVC insulated copper conductor single core cable in recessed medium class pvc conduit as required size 4x16 sqmm +2x6 sqmm earth wire |
| 10 | Supplying and fixing 6way spndb double door single pole and netural ,sheet steel , MCB distribution board 230 V on Surface/recess complete with tinned copper busbar, neutral bus bar ,din bar , interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Insultor) |
| 11 | Providing, laying & fixing of 100mm dia GI Pipe medium class in ground complete with GI Fitting as required. |
| 12 | Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.L.pipe and funnel for watering and two earthing leads of No.8 to 10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from spron to switch board the cost of G.I. pipe and G.1. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/coke and salt at least 150mm thick alround etc. complete in all respects. |
| 13 | Supply anű laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respects. |
| 14 | Supply and fixing of one number 6 SWG G.I wire on surface or reccess as required |
| 15 | SITC of APFC Panel 3 phase IP 42, suitable capacity MCCB microprosser based with O/C, S/C E/L, release of TPN 50 KA breaking capacity, ON, OFF , LED indicating lamp with required all accessaries. 50 KVAR capacity |
| 16 | SITC of Street light fixture with driver haveing di cast al body with toughend glass UV Stablished PC Cover and lenses suitable for 45 to 50 w with 120Lm per watt, PF .95 CRI more than 70 Over voltage auto cut, 4KB Surge protection with 5 year warranty Complete in alll respect. CAT AAA |
| 17 | SITC of 300 mm dia ductile iron class K-9 IS 8329 pipe icluding bend ,elbow,reducer etc. complete laboure material and T&P |
| 18 | SITC of 450 mm dia ductile iron class K-9 IS 8329 pipe icluding bend ,elbow,reducer etc. complete laboure material and T&P |
| 19 | Supply and laying of 1100 volt grade of 240sqmm 3.5 core PVC Armoured Aluminium cable complete in all respect. |
| 20 | S/F of 18” (400mm) Wall Fan - Wall Mounted Fan complete in all respect. Make: bajaj/ havells/eqvt |
| 21 | SITC of 24 KW 6P Non Clog Sewage Submersible Pumping Plant,8290LPM (497m3/h) at 10mtrs Head, Casing: CI, Impeller. CF8M, Shaft: SS 410, solid particale 50mm Auto Coupling with Duck Foot Bend, Guide Pipe 10 mtr. SS-304, Lifting Chain with Shackles 10 mtr. - Alloy Steel complete in all respect.(make Kirloskar/KSB) |
| 22 | SITC of Star delta starter for 25KW sumbersible non clock motor with overload short circuit ,single phase protection, ampere meter on/off switch & concern accessories etc. complete in all respect.Make ABB/Schenider/Siemence/Havells |
| 23 | SITC of double flanged 450mm Sluice Valve of rating PN 1.6 with rising type spindle broze /gunmatel sheet ISI marked complete with nut bolt washer gaskit Complete in all respect. (make kirloskar /eqvt) |
| 24 | SITCof double flanged 300mm Sluice Valve of rating PN 1.6 with rising type spindle broze /gunmatel sheet ISI marked complete with nut bolt washer gaskit Complete in all respect.(make kirloskar /eqvt) |
| 25 | SITC of 450mm ISI marked Reflux/Non Returen valve with dual palte of CI body SS Plate vulccanized NBR seal flanged end & PN 16 pressure rating as specified.Complete in all respect. (make kirloskar /eqvt) |
| 26 | SITC of 300mm ISI marked Reflux / Non Return valve with dual palte of CI body SS Plate vulccanized NBR seal flanged end & PN 16 pressure rating as specified.Complete in all respect. (make kirloskar /eqvt) |
| 27 | Supply and fixing of exhaust fan heavy duty 450 mm sweep single phase 1400 rpm ,240 v, 50 hz. Complete in all respect. Make Havells/Crompton/eqvt. |
| 28 | Charges of RCC Road Cutting and repairing including cost of material, T&P complete in all respect. |
| 29 | Supply & fixing of brass nickle plated compression gland .240 sqmm |
| 30 | Supply and fixing of plain or pin type copper tin plated cable socket lug 240 sqmm |
| 31 | Supply and fixing of plain or pin type copper tin plated cable socket lug 120 sqmm |
| 32 | supply and fixing of fire extinguisher ABC Type 4.00kg capacity (ISI Marked IS : 15683 & TAC approved ) complete with initial charge and wall bracket along with supply of all material and labour for proper complete of work. |
| 33 | supply and fixing of fire extinguisher C02 Type 5.0 kg capacity (ISI Marked IS : 2878 & TAC approved ) complete with initial charge and wall bracket along with supply of all material and labour for proper complete of work. |
| 34 | S/L of 1800x900x12 mm thick chequred rubber mating of tested and quality |
| 35 | S/F of Map Board chart.complete in all respect. |
| 36 | Painting of all piping and header, reducer, all sluice valve ,reflex valves etc. with one primer and two coat enamel paint complete labour material T. & P. used. |
| 37 | S/F of Stainless Steel (304) Manual BAR Screen of Suitable Size 1.0 m x 1.5 m approx. with strip size 10mm X 20mm SS 304 and suitable frame size (50X50X20mm) approx. SS304 as per direction of Engineer in charge complete in all respect. |
| 38 | Dismantling charges of DFMD, Camera, networking wiring, baggage scanner and other concern eqipment, tin shed , Foundation , door, temprory room of CCTV equipment icluding labour material and T &P used. |
| 39 | Constrution charges of temporary room 4.0m x 3.0m x3.0m with aluminium frame and ACP sheet and GI tin roof for CCTV equipment & Installation charges of DFMD, Camera, networking wiring, baggage scanner and other concern eqipment, tin shad , door, equipments foundation etc. complete in all respect |
| 40 | SITC of 200 KVA 3-Phase Power D.G. Set. Make-kirloskar or equavalent (CPCB-4) Make:-Kirloskar, Mahindra, Cummins, Catterpillar. |
| 41 | supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mouting. MS channel base with bottom and topmcable entries electrical control panel with TPN ACB (four pole 65 kA draw out type , Micro processer based release and TPN MCCB thermal magnetic release)complete and instrument chamber etc. complete in all respect. instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage , current and other parameter with each phase with touch type selector switches for different reading, instrument fueses current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbar snsulated with heat shrik sleeving and mounted on non hygroscopic support such as CMC/DMC support with detaichable side covers and shall be suitable for extension on sides. The MCCB shall be complete with suitable cable end boxes compression gland and indicating lamp on incoming etc. The job includes the groutnig of the board as per direction of engineer incharge . All outgoing 100 A and shall have an ammeter . The switch board shall be fabricated with CRCA sheet with minium thickness of 1.6/2.0 mm. Cubic type swith board shall be of category A & B only. INCOMING:-1. 630A/415 ACB 4POLE -01No 2. DIGITAL METERING (MFM) -01 Set 3. PHASE INDICATOR (R,Y,B) -01 Set OUTGOING: -1. MCCB 100A 4 Pole 36KA -04 Nos. 2. MCCB 63A 4pole 36KA -01 Nos. BUS BARS:-1. 630A FP ALUMINIUM BUSBAR -01 Set Please Enable Macros to View BoQ information |