|
| 1 | E/W in excavation by mchanical means(Hydraulic excavator)/manual means over area (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer -in-charge.All kind of soil .SOR2.6.1 |
| 2 | Excavation,supplying ,stacking and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also including ramming and watering of earth in layers not exceeding 20 cm in foundation trench ,plinth,sides of foundation etc. complete for all lift. as per analysis |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.SOR2.27 |
| 4 | Providing and laying of position cement conc. Of specified grade excluding thre cost of centering and shuttering with 1:4:8(1 cement :4 c.sand :8 graded stone aggregate 40mm nominal size derived from natural source) SOR 4.1.8 |
| 5 | Providing and laying in position: cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:6:12 (1 cement: 6 coarse sand (zone-III): 12 graded Brick aggregate 40 mm (nominal size) SOR 273 |
| 6 | Centering and shuttering including sturtting,propping etc and removal of form work for |
| 7 | Providing and laying of R.C.C with 1:1.5:3, (1 cement:1.5 c.sand(zone III) Derived from natural source :3 graded stone aggregate 20 mm nominal size derived from natural source SOR5.1.2 |
| 8 | Providing and laying of R.C.C with 1:1.5:3,(1 cement:1.5 c.sand(zone III) Derived from natural source :3 graded stone aggregate 20 mm nominal size derived from natural source SOR5.2.2 |
| 9 | Providing and laying of R.C.C with 1:1.5:3, (1 cement:1.5 c.sand(zone III) Derived from natural source :3 graded stone aggregate 20 mm nominal size derived from natural source ) SOR5.3 |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement: 4 coarse sand SOR6.1.1 |
| 11 | Brick work with common burnt clay F.P.S ( non modular) brick of class designation 7.5 in superstructure above plinth levelup to floor V level in all shapes and sizes cement mortor 1:4 (1 cement :4 c. sand) SOR6.4.1 |
| 12 | Providing and laying in position: cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:12:3 (1 Cement: 1%½ coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) SOR4.1.2 |
| 13 | Steel reinforcement for R.C.C work including straightening,cutting , bending ,placing in position and biding all complete upto plinth level.DSR5.22.6 |
| 14 | Steel work welded in built up section /framed work ,including cutting ,hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc as required .In frating ,frames guard bar ladder ,railing , brackets gatee and similar work SOR10.25.2 |
| 15 | Avg 12mm thk plaster of mix 1:4 cement and c.sand mortor i/c all etc... SOR13.4.1 |
| 16 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture,over the plastered wall surface to prepare the surface even and smmoth complete. SOR13.26 |
| 17 | Finishing wall with Premium Acrylic smooth exterior paint with silicone additives of required shadeNew work 9 tow or more coat applieid @1.67 ltr/10sqm over and incuding priming coat of exterior primer [email protected] litre/10 sqm SOR660-661 |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.SOR11.41.2 |
| 19 | Supplying and fixing rolling shutters of approved make ,made of required size M.S. laths ,interlocking together through their entire lenth and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operation complete ,including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454-part 1 and M.S. top cover of required thickness for rolling shutters DSR10.6.1 |
| 20 | Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 16.80 sqm in area DSR10.8.2 |
| 21 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8 mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified DSR 12.47.1 |
| 22 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :DSR12.51 |
| 23 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.DSR10.16 |
| 24 | Painting on GS . Sheet with synthetic enamel paint of approved brand abd manufacture of required colour to give an even shade SOR641-642 |
| 25 | Instalation of India marka II handpump with submersible pump |
| 26 | Internal water supply and sanitary installation(Lump sump) |
| 27 | Internal electric installation Please Enable Macros to View BoQ information |