Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutters without taking off shutters from the frames, area exc 1.50 sqmbut n.exc 4 Sqm each and removal to store including cutting holes for removal of hold fast complete all as specified |
| 2 | M&L Pre-cast cement concrete block masonry with solid blocks made of PCC (1:3:6) type C1 using 20mm graded stone aggregate exc 10 cm in width and set in CM 1:6 complete |
| 3 | Demolition of cement conc (un reinforced) in floors / pavings, (Below or above gl) and of any description and in any posting not otherwise specifically provided |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out |
| 5 | M&L for Cement concrete in foundations, filling and mass concrete Type D2 (1:4:8) using 40 mm graded aggregate |
| 6 | M & L rendering 10mm thick on fair faces or other than fair faces of brick work,concrete or stone masonry surfaces in CM 1:6 finished even & smooth without using extra cement all as specified. |
| 7 | Dismentling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises. |
| 8 | M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white oroloured cement to matchcomplete all as specified . |
| 9 | M & L Preparation of newly plastered wall surfaces and applying two coats oil bound distemper over a coat of primer complete.(above item shall be applied by the brush not by spray gun) |
| 10 | M & L Preparation of newly plastered surfaces of wall and applying two coat of plastic emulsion paint over a coat of primer complete. (above item shall be applied by the brush not by spray gun) |
| 11 | M&L removing damaged APP modified water proofing membrane and cleaning the surface by wire brush and water complete all as specified and directed |
| 12 | Demolition of cement concrete (unreinforced) in any position upto 50 mm inthickness (below or above ground level) complete all as specified and directed. |
| 13 | M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in Roof padding,levelling course or similar work compl all as specified & directed |
| 14 | M & L PCC (1:2:4) type B-1using 20mm graded stone agg as in Roof kerbsor similar work compl all as specified & directed |
| 15 | M&L for Screed bed or bedding layer or mortar 15mm thick in cement mortar 1:3 with WPC finishing even and smooth with out using extra cement to receive roof treatment, mixed with water proofing compound as per manufacture instruction by weight of cement over cleaned roof surface as in gradin to RCC roof surface complete all as spd and dir. Note- water proofing compound shall be measured and paid separately. |
| 16 | Supply only liquid water proofing compound complete all as specified and directed. |
| 17 | M&L for preparation of roof surfaces by brushing, cleaning and Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm |
| 18 | M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces |
| 19 | M & L for Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen |
| 20 | Taking up or down 20mm bore steel tubing and connection complete all as specified and directed. |
| 21 | Taking up or down 25mm bore steel tubing and connection complete all as specified and directed. |
| 22 | Taking up or down 15mm bore steel tubing and connection complete all as specified and directed. |
| 23 | Dismantling water tanks500 ltrs capacity . |
| 24 | S & F in repairrotational moulded polyetlene water storage tanks (Culendrical vertical with closed top) 500 ltrs cap hoisted and fixed in position all as specified. |
| 25 | S&F 20mmBall brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe. |
| 26 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any soft soil |
| 27 | M&L forProviding and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; |
| 28 | M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the complete all as specified . |
| 29 | Taking down steel tubing 15mm bore and connections fixed/laid in any situation complete all as specified. |
| 30 | S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified. |
| 31 | S&F in repair 15mm bore dia, bib taps, fancy type, chromium plated , caste copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrulepressure15mm bore fixed to pipe all as specified. |
| 32 | S&F in repair fancy type chromium plated stop valves / angle valve, cast copper alloy with crutch or butterfly handles screwed down high pressure, screwed both ends for 15mm bore iron pipe or brass ferrule complete all as specified and directed. |
| 33 | S & F vitreous china wash basin, white, flat back, size 550 x 400mm withwaste fitting of PTMT32mm size,and PVC waste pipe and fixing with new brackets including cutting and pinning in ends of brackets complete FIXED IN REPAIR all as specified. |
| 34 | S & F in repair Vitreous China bowl urinal flat back, size 465x355x265 mm ( minimum ) white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe ) as in repairs including making good the disturbed surface to match with the existing surface. |
| 35 | S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection 15mm size 450mm long to WC pan complete all as specified. |
| 36 | S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges. |
| 37 | S&F chromium plated soap tray any type and fixed to plugs on wall with chromium platedbrass screws complete all as specified and directed. |
| 38 | S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 X 260 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor. |
| 39 | S&F 100 mm bore CI P or S trap , CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door, complete all as specified |
| 40 | M&L for 75mm dia of CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair completeall as specified. |
| 41 | Demolition of PCCblock/stone masonery built in cement mortar of any specification and in any position complete all as specified. |
| 42 | M&L for Powder coated aluminium section indoor frame ,swing door, sliding window and partition walls complete including connecting accessories like allu grill for guard,fittings, glazing clips, handles, pivots etc fixed complete as directed by Engineer-in-Charge. |
| 43 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built upstandard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequiredEPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically whereverrequired including cleat angle, Aluminiums nap beading for glazing/ paneling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief. |
| 44 | M&L for Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screwscomplete all as specified |
| 45 | S&F for 5.5 mm thick dark colouredglass in aluminium door partitions including ped/gasket complete all as specified make MODI GUARD. |
| 46 | S&F for 4.00 mm thick dark colouredglass in aluminium window partitions including ped/gasket complete all as specified make MODI GUARD. |
| 47 | M&L Door closer hydraulically regulated,designation No. 1 universal type,suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed |
| 48 | S&F for AluminiumMotrice lock, vertical type 75mm sizefor aluminium doors . |
| 49 | Supply and fixing 100mm long butt hinges extruded of cold rolled mild steel medium weight |
| 50 | Supply and fixing 150mm long extruded aluminum handles fabricated type anodized, ISI marked. |
| 51 | S&F aluminium anodised barrel tower bolt of extruded section 150mm long |
| 52 | S&F for floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. |
| 53 | Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 54 | M&L for Anodised aluminium snap grid frame work for false ceiling as specified. |
| 55 | M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions etc complete all as specified and directed. |
| 56 | M&L for preparation of old treated/ decorated external wall/roof surfaces of any storeys /any height of any description and applying one coat of exterior emulsion paint (weather coat) 1st quality in different tints/shades in sigma/ camouflaging pattern as approved complete all as specified & as directed. |
| 57 | M&L for preparation of old decorated wall surfaces of any description and applying one coat of oil emulsion distemper of any tintsas approved complete all as specified and directed. |
| 58 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 markedof size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 25/20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly complete all as specified and directed.. |
| 59 | All as per serial item No. 1 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. |
| 60 | All as per serial item No.1here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour. |
| 61 | M&L for submain wiring with two run of single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm 1100 volt grade and one run of PVC insulated unsheathed solid copper conductor cable of size 6 sqmm 1100 volt grade as earth continuty conductor drawn through and includingsteel conduit of suitable size 20/25 mm on roof/wall/ceiling etc all as directed by Engr-In-ChrgeNote :- Two runsof6 sqmm cableandonerun of 4 sqmm earthwire and steel conduit pipe shallbemeasuredasonelength. |
| 62 | Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts. |
| 63 | Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, 230 Volts. |
| 64 | Supply and fixing socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts. |
| 65 | Supply and fixing socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts. |
| 66 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 67 | Supply and fixing decorative ultra slim linerLED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tubeand connecting up, complete all as specified and directed |
| 68 | S&F Ceiling rose with earth terminal connection, 3 terminal PVC/ polycarbonate body complete all as specified.. |
| 69 | S&F Sheet Metal enclosure for VTPN DBs, 6 Ways, Double Door(IP-43), built- in bus bars complete suitable for 415 Volts, AC, 50 Hz supply, suitable for incoming MCCB and outgoing MCBsand fixed in recess in brick masonary wall complete all as specified and directed by the Engr-in-charge. |
| 70 | M&L 4 Pole MCCB 125, 50 Hz, 415 V with rupturing capacity 16KA. complete including connecting to MCB DB all as specified and directed. |
| 71 | S & F MCB 32 Amp, single pole & neutral,240 Volt complete all as specified & directed. |
| 72 | S & F MCB 6-32 Amp, single pole240 Volt complete all as pecified & directed. |
| 73 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. |
| 74 | Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. |
| 75 | Supply, installation, testing and commissioning of Inverter Technology,Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR, fitted with rotary compressor, Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) including , PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipesand making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and directed.Make-Latest Model of LG/Blue Star/Hitachi/Voltas/lyod |
| 76 | Supply & fixing heavy duty copper pipe 12mm (1/2\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 77 | Supply & fixing heavy duty copper pipe 6mm (1/4\") dia/ bore thickness not less then 0.70 mm complete including brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. |
| 78 | supply and fixing new nityrile rubberinsulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR complete all as directed by engg-in-charge |
| 79 | Supply & fixing wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed.Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. |
| 80 | S&F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacitycomplete all as specified and directed by Engr in charge. |
| 81 | M&L for wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity complete all as specified and directed. |
| 82 | M & L for surface Sub main wiringwith tworunsof 4 sqmm single core PVC insulated unsheathed multistrandedwith copperconductorcable , 1100Volts FRLS-Hgrade ISImarkeddrawnthrough in and including stove enamelled steel conduit& including onerunof 4 sqmmPVCinsulatedunsheathed strandedcopper conductor cablegreenin colour forearthcontinuityconductor and making good the distrubed surfaces after completing the work and clearing the site complete all as specified and directed.Note :- Two runsof4 sqmm cableandonerun of 4 sqmm earthwire and steel conduit pipe shallbemeasuredasonelength. |
| 83 | Supply & fixing new PVC drain pipe 15 mm dia with coupler Joint for Split/window AC complete all as specified & as directed. |
| 84 | Supply & fixing Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 85 | Removingand refixing of air curtain blower and connected works |
| 86 | Taking down window type Acs unit/split type Acs (indoor/outdoor unit) of any capacity complete removal of existing location including of worn out bolts ,nuts etc complete all as specified and directed |
| 87 | Refixing ofWindow/Split type ACs (indoor/Outdoor unit ) of any capacity complete removal of existing paint incl scraping the old faded paint and applying one coat of synthetic enamel paint by using sprayer , giving necessary electric connection,necessary required charging of refrigerant gas and testingincluding replacement of worn out bolts, nuts etc. complete all as directed. |
| 88 | M&L for chemical earthing with Copper earth plate of size 900 x 600x5mm buried diagonally directly in ground, Earth pit shall be not less 5100mm depth from GL level, 1800mm length and 1600mm widthwith top edge of the plate shall be not less than 3400mm below ground level connected to and including providing with copper strip of size 32 x 6mm, 07.50 mtr length and fixed by means ofnuts, bolts, check nuts and washers of suitbale metal and providing of common salt, charcoal dust and chemical MgSo4 with alternate layer from bottom of the excavated pit upto 1700mm high, The copper plate shall be packed minimum 300mm all around the copper plate in alternate layer of100mm thick (Layer shall be of charcoal dust - 100mm, common salt - 100mm, MgSo4 - 100mm and the same shall be repeated upto 1700mm height) in and including necessary excavation, returing filling in any type of soil and testing complete all as specified and directedin and including the following:- (a) Excavation and earth work for making hole for electrode in any type of soil (b) PCC earth Pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 400mm thick in PCC 1:2:4 type B-1, reinformed with welded steel wire fabric weighing not less than 01.87Kg/Sqm, PCC earth pit shall be constructed as per plate Number 5of MES SSR Part -1 (1991)(c ) Funnel with watering pipe of GI 20mm nominal bore light grade and lugs etc complete all as specified and directed(d) 50mm bore GI light grade pipe with all fittings for protection of copper strip upto 5 meter length(e) Adequate quantity of Common salt, charcoal dust and MgSo4 chemical as required(f) Testing after completion of work, if testing result is not satisfactory, earthing will be redone by the contractor at his own expense |
| 89 | Supply & fix copper strip 20mm x 3 mm buried in ground/ fixed on wall/ Passed through pipe/wall incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed |
| 90 | M&L for GI Tubes, of 32mm bore size, light grade ,galvanised including fittings , with clamp of iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road for protection of copper strips etc complete all as specified and as directed. |
| 91 | M&L Test point terminal block made of gun metal or phosphorus bronze size75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specifed and directed |
| 92 | M&L providing earth chamber of size 300 mm x 300mm (Internal size),and depth 280mm and 75mm thick with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 93 | Supply & fixing MS Cross arms , bracing,supports, clamps and back plates fabricated from structuralsteel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only. |
| 94 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified. |
| 95 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by engineer-in-charge |
| 96 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick. |
| 97 | Supply and erecting steel tubular poles complete with cast iron base plate finial taper plug , bolts Nuts & screws complete all as specified type 410SP 55 of 11mtrlong including painting of pole with one coat red oxide primer & two coat of aluminum paint & emedded portion shall be painted with two coat of black paint all as psecified in IS including the following:-(Refer TD grw No CEJZ/TD/824/91, Sht No1/2 dt 16.04.91 (a) Excavation in post holes in any types of soil ,return filling , well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(b) PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation up to ground level all as specified and directed .(c) PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in coping including necessary form work. (d) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work. (e) M&L for writing letters of figures ( Black, Roman, Itallicor Indian) with thick enamel paint of approved shade mn exc 5cm height in numbering of pole all as specified and directed . |
| 98 | Supply and fixing Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed at site by Engr-in-charge |
| 99 | M& L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 50 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 100 | Supply & fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed by Engineer-in-Charge. |
| 101 | M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed |
| 102 | M&L for GI Tubes, of 32mm bore size, light grade ,galvanised including fittings , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road for protection of LT cables or earth strips etc complete all as specified and as directed. |
| 103 | M&L Test point terminal block made of gun metal or phosphorus bronze size75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specifed and directed |
| 104 | M&L providing earth chamber of size 300 mm x 300mm (Internal size),and depth 280mm and 75mm thick with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 105 | Supply & fixing MS Cross arms , bracing,supports, clamps and back plates fabricated from structuralsteel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only. |
| 106 | Supply, installation, commissioning, and testing of a 04-zone conventional fire alarm control panel, compliant with EN 54-2 and EN 54-4, LPCB approved, featuring non-latching zones and advanced false alarm management. The system shall include a suitable battery to ensure uninterrupted operation, complete in all respects as specified and directed by Engr-in-charge |
| 107 | M & L for surface flame proof Sub main wiring with under mentioned single core PVC insulated unsheathed multistrandedwith copperconductorcable, 1100Volts FRLS-Hgrade ISImarkeddrawnthrough in and including ERW steel conduit with flame proof accessories and including onerun ofFRLS-H PVCinsulated single core cable unsheathed strandedcopper conductor cablegreenin colour forearthcontinuityconductor complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs/ four runs single core cableandone/ tworuns single core cable ofearthwire and one run of ERW steel conduit pipe shallbemeasuredasonelength.2 run of 1.5 Sqmm single core cable and 1 run of 1.0sqmm single core cable connected to common earth dolly |
| 108 | -Ditto- all item as per Ser No 113.00 above but 2 run of 2.5 Sqmm single core cable and 1 run of 1.0sqmm single core cable connected to common earth dolly |
| 109 | Supply, fixing and connectingconventional optical smokeDetectors Complying with and type certifiedcomplete with standard base for conventional detector complete all as specified and directed |
| 110 | Supply, fixing and connecting in replacement analog addressable type multi criteria combination of (smoke & heat)heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed by Engr-in-charge |
| 111 | Supply, fixing and connecting conventional type manual call point resettable complete all as specified and directed |
| 112 | Supply, fixing, connecting and testing conventional wall sounder complete all as specified and directed |
| 113 | Supply and fix Remote response indicators complete all as specified and directed |
| 114 | Shifting,Intsallation and testingof Modular fire extinguisher to New equipment room complete all as specified and directed |
| 115 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / underroads/ hard standing /along poles and testing LT cable XLPE, insulated screened,bedded, galvanised steel strip or wire armourd cable(heavy duty) 1100 volt gradewith aluminium conductor having cross sectional area 95 Sqmm4 coreconforming to IS-7098 (Part-I -1988) complete all as specified by Eng-in-charge |
| 116 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified. |
| 117 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed by engineer-in-charge |
| 118 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick. |
| 119 | M&L for tibba sand cushioning to under ground cable in trenches/existing cabletrenches/ducts in layers of 8cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge |
| 120 | M&L Stone patti 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35 cm wide and not less then 60 cm in length laid dry abutting each other with gap between adjacent slab not excedding 10mm over sand cushioning complete all as specified and directed |
| 121 | M&L for GI Tubes, of size 40mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 122 | Boring holes under road pavement by bocky manually, in any type of soil upto 200 mm bore Complete all as specified and as directed. |
| 123 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 315 Amps with busbar. |
| 124 | Supply and lay pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia |
| 125 | PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and directed by Engineer-in-Charge. |
| 126 | Supply and installing testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Copper bus bar 350 Amps not less than 60 cm longrating installed on porcelain insulators.The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, frontand rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with 45cm height from ground level with PCC foundatioin in 1:4: 8 type D-2 complete the following accessories :-( PraposedLT Panel)(a) MCCB 200 Amp 50 KA rating 4 Pole 440 voltswith megnatic setting and thermal releaseadjustable to 70 to 100 % - 01 Nos(b)Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.)(c) Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availability-01Set.(d) Copper bus bar three phase300 Amp- Set of 4 Nos.Outgoing a) MCCB 63 Amp 16 KA rating 4 Pole 415 voltswith megnatic setting and thermal release adjustable to 70 to 100 % - 02 Nos -(1W+1S) b) MCCB 40 Amp 16 KA rating 4 Pole 415 voltswith megnatic setting and thermal release adjustable to 70 to 100 % - 02 Nos -(1W+1S) c) MCCB 25 Amp 16 KA rating 4 Pole 415 voltswith megnatic setting and thermal release adjustable to 70 to 100 % - 01 Nos c) MCCB 100 Amp 25 KA rating 4 Pole 415 voltswith megnatic setting and thermal release adjustable to 70 to 100 % for harmonic filter- 01 Nos |
| 127 | S&F for LED Street Light of Capacity 35 Watt With inbuilt Driver having Pressure die cast Aluminium housing, IP-66 Having Efficiency of ≥ 100 Lumens/Watt, Operating voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Suitable for 30 to 40 mm O.D Mountingn Pipe andSuitable for mounting of Wall / Pole With necessary Mounting arrangements including connecting up with three core twisted flexible copper conductor cable with suitable size, mounting Pipe/Bracket, Nut, Bolts and Accessories including disconnected & taking down oldunserviceable light complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail