| 1 | Operation and maintenance of street lights and flood lights on main carriage way, service roads & slip roads on and around Dwarka Flyover as per inventory and terms & condition attached by deploying following staff-1) 1 no. Wireman (Gr.-1) per day in general shift & as and when required, decided by Engineer-in-charge.2) 1 no. Khallasi per day per day in general shift & as and when required, decided by Engineer-in-charge. |
| 2 | Providing a motorized man lift crane suitable for 9 m pole for replacement and rectification of the existing street light fitting mounted on 9 m poles and LDE flood light etc. complete as required. |
| 3 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioningof Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 150 watt |
| 4 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK 10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C).a) 120 watt |
| 5 | Supplying of following size of XLPE insulated PVC sheathed of 1.1 KV Grade Al. cond. armoured power cable including dismantling old cable, connection, testing etc. as required.a) 4C x50 sq. mm. |
| 6 | b) 2C x 25 sq.mm |
| 7 | Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of following size in the existing RCC/Hume/metal/pipe as reqd. (a) Up to 35 sq.mm |
| 8 | (b) Above to 35 Sq.mm and upto 95 Sq.mm |
| 9 | Supplying and laying (overhead) of following size of XLPE insulated PVC sheathed of 1.1 KV Grade Al. cond. unarmoured power cable including dismantling old cable, connection, testing etc. as required.a) 2C x25 sq. mm. |
| 10 | Supplying, laying and fixing of one number PVC insulated and PVC sheated/XLPE aluminium conductor unarmoured power cable of 1.1 KV grade of following size on wall surface etc as reqd. a) 2C x25 sq. mm (clamped with 1 mm thick shuddle) |
| 11 | Supplying & drawing of 1.5 sq.mm FRLS PVC insulated copper conductor wire in existing poles PVC conduit as reqd. |
| 12 | Fabricating,providing and fixing of M.S connector cover on existing 9m high M.S swaged pole with suitable size made out of 1mm thick M.S sheet with welded to pole from one side and another side tight by 2 nos. M.S flat clamp(1.6 mm thick) nut bolts etc i/c painting with approved shade i/c dismantling the existing damaged/rust connector cover tec complete as required. |
| 13 | Providing boring and laying of HDPE pipes (ISI marked) confirming to IS:4984 with pressure rating of 6kg/Sq.cm by trench less technology with no dig. method by making bore hole in horizontal direction across the road with boring equipment a) 63 mm (outer dia) |
| 14 | Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. |
| 15 | Painting of 9 m High M.S swagged pole with enamel paint double coat by motorized vehicle i/c rubbing/peel off the existing paint with steel brushes,emery paper and paint with approved shade etc. complete as required and numbering of pole with circuit wise. |
| 16 | Providing & Fixing25 mm X 5 mm G.I Strip on surface on in recess for connection etc. as reqd. |
| 17 | Supplying and replacement of followingitems in existing cubical panel board i/c drilling holes in cubical panel, making connections, installation, testing,commissioning etc. complete as required. (a) 160 Amp -36 KA FPMCCB |
| 18 | (b) 250 Amp-36KA 4 P MCCB |
| 19 | (c)63amp SPN Mcb of C series |
| 20 | (d)Analog Timer |
| 21 | (e)power Contactor 3 pole, 110 Amp |
| 22 | (f) 6 to 32 Amp. DP MCB, C Series, 10KA |
| 23 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK 10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C).a) 200 watt |