Housing Urban and Rular Development Government Departments Closing in 0 days TDR #54274231

Maintenance Of Electrical Installation And Fans, Electrical And Mechanical Equipment Installed At Niepid Kharghar, Navi Mumbai.

Issued by Government Departments · Navi Mumbai, Maharashtra
Tender Value
26.80 Lakhs
Estimated cost
Bid Submission
05 Mar 2026
0 days left
EMD
53618
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Navi Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

maintenance of electrical installation And Fans, electrical and mechanical Equipment Installed At Niepid Kharghar, Navi Mumbai.-No PART A - Internal EI 1 Providing routine operation and maintenance services for complete internal electrical installations including wiring systems, distribution boards, lighting fixtures, fans, sub-station equipment, DG set, fire fighting system and fire alarm system, including attending power breakdowns, fault rectification, minor repairs, replacements, preventive maintenance and day-to-day upkeep, in two shifts on all days of the week, by deployment of skilled manpower comprising 02 Nos. Wireman and 01 No. Khallasi during general shift, complete in all respects as per attached terms, conditions and directions of Engineer-in-Charge PART B - Automatic Fire Alarm System 2 Annual Comprehensive Maintenance Contract of complete Automatic Fire Alarm System including routine inspection, testing, servicing, fault diagnosis and rectification, replacement of defective detectors, repair/servicing of Fire Alarm Control Panel, Loop Panel, hooters, response indicators, wiring and all associated accessories, ensuring reliable and continuous operation of the system, complete in all respects as per attached inventory list, terms & conditions, and directions of Engineer-in-Charge. PART C - Fire Fighting System 3 Annual Routine Maintenance of complete Fire Fighting System including fortnightly inspection and checking of all pumps, valves, hydrants, hose reels, sprinklers, pipelines, control panels and associated components, attending and rectifying faults, conducting periodic testing and performance verification of the entire system, maintaining proper operation, upkeep and statutory records/logbooks, complete in all respects as per specifications and directions of Engineer-in-Charge PART D - CCTV LAN & EPBAX System 4 Annual Comprehensive Maintenance of complete IP based CCTV Surveillance System comprising 30 Nos. Indoor IR Dome Cameras, 9 Nos. Outdoor IR Bullet Cameras, 48 Channel Network Video Recorder (NVR) with monitor, storage, power supplies, network switches, structured cabling and all associated accessories, along with Hybrid EPABX System of NEC Corporation make having capacity up to 6 CO lines and 32 extensions, including routine inspection, preventive maintenance, cleaning, testing, attending faults, repairs/ replacement of defective cameras/ components/cards /modules/ handsets, rectification of wiring and network issues, software configuration/programming, and ensuring continuous, reliable and satisfactory operation of the entire system, complete in all respects as required. PART E - Split Air Conditioning5 Annual Comprehensive Maintenance of Split Inverter Type Hi-Wall and Cassette Air Conditioning System including all outdoor and indoor units of capacities 1 TR Hi-Wall – 3 Nos., 1.5 TR Hi-Wall – 11 Nos., 1.8 TR Hi-Wall – 4 Nos., and 2.5 TR Cassette – 3 Nos., covering routine inspection, preventive servicing, cleaning, testing, attending breakdowns, and replacement/repair of all defective components and consumables such as fan motors, blower motors, compressors, control wiring, control panels, PCB/controls, drainage lines, solenoid valves, temperature sensors, expansion valves, refrigerant gas charging/topping-up, electrical and mechanical parts, and all associated accessories to ensure continuous, efficient and satisfactory operation, complete in all respects as per terms and conditions. PART F - Water cooler 6 Annual Comprehensive Maintenance of 6 Nos. 80 Litre Storage Capacity Water Coolers with inbuilt/external purifier including attending complaints and breakdowns, quarterly preventive servicing, inspection, testing and commissioning, refrigerant gas charging/topping-up, repair/replacement of defective components such as carbon filters, filter candles, photo resistors, control cards (PCB), electrical and mechanical parts, and all associated accessories, including removal and credit of old/unserviceable materials, complete in all respects as per terms and conditions PART G - B Check of DG Set 7 Providing B–Check servicing of existing 160 kVA Diesel Generator Set including complete preventive maintenance works comprising draining and replacement of engine oil (35 litres), replacement of coolant (5 litres), replacement of oil filter and oil bypass filter, replacement of air filter, radiator chemical cleaning and flushing, inspection of fuel, lubrication, cooling and electrical systems, tightening of connections, operational testing and performance checks, and completion of all allied materials, labour and consumables, complete in all respects as required. PART H - Refilling of Fire Extinguisher 8 Refilling, servicing, testing, certification, and reinstatement of Fire Extinguishers of various capacities and types at manufacturer’s/authorized company factory premises, including safe collection from site, to and fro transportation, complete discharge of residual contents, internal inspection, replacement of defective components such as valve assembly, O-rings, safety pin, discharge hose, horn, gasket and seals, refilling with approved extinguishing media (DCP/CO₂/Water/Mechanical Foam/Clean Agent as applicable), repressurizing, leak testing, repainting/touch-up, pasting of service label with date of refilling and next due date, and submission of test/service certificate, complete in all respects, including reinstallation at site as required. a ABC type Fire Extinguisher 4 Kg b Co2 type Fire Extinguisher 4.5Kg c Dry chemical (DC) powder type fire extinguisher 6 Kg capcity PART I - Maintenance Material & Diesel 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a 5/6 Amp Modular switch b 5/6 Amp Modular Socket (3 Pin) c 15/16 Amp Switch d 15/16 Amp Socket (6 Pin) 10 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 10.1 40Watt 11 LED Down lighter (SMD Type) (System lumen efficacy ≥ 120 < 135 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim 12 -15 watt 12 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 36 watt 13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 13.1 25 Watt 14 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 14.1 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 15 SITC of Metal body exhaust fan of following size in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 15.1 300 mm 16 SITC of PVC body exhaust fan of following size in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 16.1 150 mm 17 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a 6 to 32 Amp. SP MCB b 32/40 Amp. DP MCB c 32/63 Amp. TP MCB 18 Supplying of High-Speed Diesel (HSD) for existing DG set i/ transportation charges from petrol pump to site and refilling the DG fuel tank and keeping record for the same, etc complete as required. 19 Servicing & repairing of damaged PCB of BLDC Ceiling Fan which is upto 80 to 300 v i/c removing the fan from ceiling, tightening the loose connection, testing the Ceiling Fan, remote testing, and refixing the fan in same position i/c credit for old dismantle material etc as required.

AI Tender Summary

OUR REF NO 54274231
AUTHORITY Government Departments
TENDER VALUE 26.80 Lakhs
LAST DATE 05-03-2026
Authority
Authority Name Central Public Works Department
Work Description maintenance of electrical installation And Fans, electrical and mechanical Equipment Installed At Niepid Kharghar, Navi Mumbai.-No PART A - Internal EI 1 Providing routine operation and maintenance services for complete internal electrical installations including wiring systems, distribution boards, lighting fixtures, fans, sub-station equipment, DG set, fire fighting system and fire alarm system, including attending power breakdowns, fault rectification, minor repairs, replacements, preventive maintenance and day-to-day upkeep, in two shifts on all days of the week, by deployment of skilled manpower comprising 02 Nos. Wireman and 01 No. Khallasi during general shift, complete in all respects as per attached terms, conditions and directions of Engineer-in-Charge PART B - Automatic Fire Alarm System 2 Annual Comprehensive Maintenance Contract of complete Automatic Fire Alarm System including routine inspection, testing, servicing, fault diagnosis and rectification, replacement of defective detectors, repair/servicing of Fire Alarm Control Panel, Loop Panel, hooters, response indicators, wiring and all associated accessories, ensuring reliable and continuous operation of the system, complete in all respects as per attached inventory list, terms & conditions, and directions of Engineer-in-Charge. PART C - Fire Fighting System 3 Annual Routine Maintenance of complete Fire Fighting System including fortnightly inspection and checking of all pumps, valves, hydrants, hose reels, sprinklers, pipelines, control panels and associated components, attending and rectifying faults, conducting periodic testing and performance verification of the entire system, maintaining proper operation, upkeep and statutory records/logbooks, complete in all respects as per specifications and directions of Engineer-in-Charge PART D - CCTV LAN & EPBAX System 4 Annual Comprehensive Maintenance of complete IP based CCTV Surveillance System comprising 30 Nos. Indoor IR Dome Cameras, 9 Nos. Outdoor IR Bullet Cameras, 48 Channel Network Video Recorder (NVR) with monitor, storage, power supplies, network switches, structured cabling and all associated accessories, along with Hybrid EPABX System of NEC Corporation make having capacity up to 6 CO lines and 32 extensions, including routine inspection, preventive maintenance, cleaning, testing, attending faults, repairs/ replacement of defective cameras/ components/cards /modules/ handsets, rectification of wiring and network issues, software configuration/programming, and ensuring continuous, reliable and satisfactory operation of the entire system, complete in all respects as required. PART E - Split Air Conditioning5 Annual Comprehensive Maintenance of Split Inverter Type Hi-Wall and Cassette Air Conditioning System including all outdoor and indoor units of capacities 1 TR Hi-Wall – 3 Nos., 1.5 TR Hi-Wall – 11 Nos., 1.8 TR Hi-Wall – 4 Nos., and 2.5 TR Cassette – 3 Nos., covering routine inspection, preventive servicing, cleaning, testing, attending breakdowns, and replacement/repair of all defective components and consumables such as fan motors, blower motors, compressors, control wiring, control panels, PCB/controls, drainage lines, solenoid valves, temperature sensors, expansion valves, refrigerant gas charging/topping-up, electrical and mechanical parts, and all associated accessories to ensure continuous, efficient and satisfactory operation, complete in all respects as per terms and conditions. PART F - Water cooler 6 Annual Comprehensive Maintenance of 6 Nos. 80 Litre Storage Capacity Water Coolers with inbuilt/external purifier including attending complaints and breakdowns, quarterly preventive servicing, inspection, testing and commissioning, refrigerant gas charging/topping-up, repair/replacement of defective components such as carbon filters, filter candles, photo resistors, control cards (PCB), electrical and mechanical parts, and all associated accessories, including removal and credit of old/unserviceable materials, complete in all respects as per terms and conditions PART G - B Check of DG Set 7 Providing B–Check servicing of existing 160 kVA Diesel Generator Set including complete preventive maintenance works comprising draining and replacement of engine oil (35 litres), replacement of coolant (5 litres), replacement of oil filter and oil bypass filter, replacement of air filter, radiator chemical cleaning and flushing, inspection of fuel, lubrication, cooling and electrical systems, tightening of connections, operational testing and performance checks, and completion of all allied materials, labour and consumables, complete in all respects as required. PART H - Refilling of Fire Extinguisher 8 Refilling, servicing, testing, certification, and reinstatement of Fire Extinguishers of various capacities and types at manufacturer’s/authorized company factory premises, including safe collection from site, to and fro transportation, complete discharge of residual contents, internal inspection, replacement of defective components such as valve assembly, O-rings, safety pin, discharge hose, horn, gasket and seals, refilling with approved extinguishing media (DCP/CO₂/Water/Mechanical Foam/Clean Agent as applicable), repressurizing, leak testing, repainting/touch-up, pasting of service label with date of refilling and next due date, and submission of test/service certificate, complete in all respects, including reinstallation at site as required. a ABC type Fire Extinguisher 4 Kg b Co2 type Fire Extinguisher 4.5Kg c Dry chemical (DC) powder type fire extinguisher 6 Kg capcity PART I - Maintenance Material & Diesel 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a 5/6 Amp Modular switch b 5/6 Amp Modular Socket (3 Pin) c 15/16 Amp Switch d 15/16 Amp Socket (6 Pin) 10 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 10.1 40Watt 11 LED Down lighter (SMD Type) (System lumen efficacy ≥ 120 < 135 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim 12 -15 watt 12 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) 36 watt 13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 13.1 25 Watt 14 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 14.1 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 15 SITC of Metal body exhaust fan of following size in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 15.1 300 mm 16 SITC of PVC body exhaust fan of following size in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 16.1 150 mm 17 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a 6 to 32 Amp. SP MCB b 32/40 Amp. DP MCB c 32/63 Amp. TP MCB 18 Supplying of High-Speed Diesel (HSD) for existing DG set i/ transportation charges from petrol pump to site and refilling the DG fuel tank and keeping record for the same, etc complete as required. 19 Servicing & repairing of damaged PCB of BLDC Ceiling Fan which is upto 80 to 300 v i/c removing the fan from ceiling, tightening the loose connection, testing the Ceiling Fan, remote testing, and refixing the fan in same position i/c credit for old dismantle material etc as required.
Basic Detail
Tender No 26/EE(E)/Navi Mumbai/2025-26
Bidding Type Tender
Location
City Navi Mumbai
State Maharashtra
Key Dates
Publish Date 25 Feb 2026
Submission Date 05 Mar 2026
Open Date 05 Mar 2026
Finance
Tender Value 26.80 Lakhs
Tender Fee Ref. Documents
EMD 53618
Exemption Not Available
Document List
d60e4297-6c12-4759-9f70-b009ee27633d.html
DocumentsList.zip

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d60e4297-6c12-4759-9f70-b009ee27633d.html

zip

DocumentsList.zip

TenderDetail
Loading tenders