| 1 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excacation in trenches, n exc 1.5 m wide and n exc 1.5m deep for foundation etc, or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft loose soil / hard densesoil complete all as specified and directed. |
| 3 | M &L for PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) as in foundation filling and mass concrete, sub base of floor, etc complete all as specified and directed. |
| 4 | M & L for RCC-M-30 (Design mix)using 20mm graded aggregate as in foundations, incl raft, footings, fdn beam, plinth beam base for column complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed. |
| 6 | Removing excavated material to a distance not exceeding 50 meters and deposited where directed at level not exceeding 1.5 meters above the starting point complete all as specified and directed. |
| 7 | M & L for moorum / red bajri filling in floor or paving, laid in layers not exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 8 | M & L for hardcore of crushed broken stone or boulders gauge n exc 63mm, deposited, spread and leveled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | Use and waste of form work to sides of concrete foundation, footings, bases of column, raft and raft beams, sides of soffits of foundation of plinth beam, and similar work, rough finished surfaces of concrete measured flat complete all as specified and directed. |
| 10 | M & L for mild steel TMT CRS bars 10mm dia and over (Fe-500D) cut to length, bent to shape required including, cranking, bending spirally forhooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 11 | M & L for mild steel TMT bars 5mm dia,and over (Fe-500D) upto and incl 10mm diain stirrups, cut to length, bent to shaperequired including cranking, bending spirally, hooping for beams, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 12 | Use and waste of formwork to sides of pillars, posts, sturts, piers, columns and stanchions, square, rectangular or polygon for rough finished surfaces of concrete complete all as specified and directed. |
| 13 | M & L for RCC-M-30 (design mix) using 20mm graded aggregate for column, pillars, piers, posts and struts complete all as specified and directed. |
| 14 | Use and waste of formwork to sides and soffits of floor or roof beam, hunching, lintels, catiliver, shelves, including supports, overhangs etc rough finished surface of concrete, complete all as specified and directed. |
| 15 | Use and waste of formwork to soffits of suspended slab such as roof slabs, floor slabs landing and similar work not exc 200mm thick rough finished surface of concrete complete all as specified and directed. |
| 16 | M & L for RCC-M-30 (design mix) using 20mm graded aggregate for slab supported on walls, beams and column in floors, roofs, landing, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed. |
| 17 | M & L for PCC 1:3:6 pre cast solid cement concrete block masonary with solid block exc 10CM in width and setting in cement mortar 1:6complete all as specified and directed. |
| 18 | M & L for rendering 10mm thick plaster in CM (1:6) on fair faces of brick work or concrete surfaces, finished ven and smooth (without using extra lime or cement) complete all as specified and directed. |
| 19 | M & L for rendering 5mm thick on fair faces of brick work or concrete surfaces as on ceiling surface, facia and projection of slabs, and window projection, in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M & L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 including WPC for second coat @ 3% by wt of cement and finished even and fair on walls complete all as specified and directed.Note: Supply only WPC will be measured and paid for separately. |
| 21 | Supply only WPC complete all as specified and as directed |
| 22 | M&L for 25 mm thick plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring in leveling course complete all as specified and directed. |
| 23 | M&L for vitrified ceramic tiles 10 mm thick (square/ rectangular) polished and double charged, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etclaid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 24 | M&L for coloured glazed ceramic (joint free)tiles 7 mm to 8 mm thick (square / rectangular) of size 350 x 250 x 7mm / 450 x 350 x 7mm thick as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surfaces of walls & applying two coats of distemper oil emulsion overa coat of primer on wall surfaces complete all as specified and directed. |
| 26 | M & L for preparation of new plasterered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 27 | M & L for preparation of newly plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/10 sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm over new surfaces, complete all as specified and directed. |
| 28 | Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg/Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane reinforced non-woven polyester, weight not less than 3.50 Kg/Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and directed. |
| 29 | Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) threetrack window (two shutters glazed) with frame, glazed with 5 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in Member for wire gauge Section shall be 18.00 x 25.00 x 1.35 (Section No 20791) fixed in position. Concealed type lock for all two shutter, PVC roller etc all as specified below, including taking down old window complete all as specified and directed. (a) Frame (top & side) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter section shall be of size 18.00 x 40.00 x 1.55 (Section No 20738) (d) Shutter interlock section shall be of size 18.00 x 40.00 x 1.45 (Section No 20737) (e) Bottom Members of shutter section shall be of size 18.00 x 40.00 x 1.55 (Section No 20736) Note:- Section No given above are of make Jidal, Contractor may use similar section of other make mention in Appx B. |
| 30 | Supply fabricate & fix in position anodised aluminium powder coated (minimumthickness of powder coating 50 micron) door shutter with frame partly glazed with 5 mm and partly apnnled with 9 mm thick prelaminated particleboard with both side decorative laminatedincluding rubber bead joining cleat for fixing in position, alumimium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all specified below complete all specified and directed. (a) Frame (top & side) section shall be of size 101.60 x 44.75 x 2.40 mm (SectionNo14021) (b) Verticle membersection shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top of shutter Section shall be of size 83.51 x 44.45 x 2.00 (Section No 19581) (d) Lock rail (middle member) Section shall be of size 150.00 x 44.45 x 3.00 (Section No 19596) (e) Bottom Members of shutter section shall be of size 150.00 x 44.45 x 3.10 (Section No 19584) (f) glazing clip of securing glass of shutter shall be of 0.80 mm thick (section No.19370) |
| 31 | M&L for 75 mm thick plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate as in plinth protection surfaces finished even and smooth without using extra cement including filling the joints complete all as specified and directed. |
| 32 | S&F GI powder coated framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work complete all as specified and directed. |
| 33 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 34 | M & L for rendering 10mm thick plaster in CM (1:3) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra lime or cement complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 35 | M& Lfor forming 6 mm wide and 10 mm deep joints in PCC and joints filed with bituminious mastic (1 part of bitumen and 2 part of sand )in plinth protection complete all as specified and directed. |
| 36 | M & Lfor 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 37 | S&F for 2mm thick fibre glass reinforced translucent plain sheeting fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 38 | S&F for mild steel work as trusses (frmed), trussesed, purlin, rails and other fastening and heavy brackets framing (beam, tee, angle, channel or fast section) including distance pieces etcFe-410-WA complete all as specified and directed. |
| 39 | S & F 25 mm dia curtain rails, mild steel, chromium plated with fixing brackets / concealed brackets & holders, stops, rollers etc.decorative type complete all as specified and directed. |
| 40 | Excavation in trenches not exceeding1.5 meters wide and 1.5 meters in depth and getting out in hard/dense soil including cutting of roots any dia complete all as specified and directed. |
| 41 | Excavation in trenches not exceeding1.5 meters wide and depth exc. 1.5 meters but n.exc 3mtr and getting out in hard/dense soil including cutting of roots any dia complete all as specified and directed. |
| 42 | Demolition and breaking up drain pipes of internal dia 150mm (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 43 | Demolition and breaking up drain pipes of internal dia 200mm (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 44 | Demolition and breaking up drain pipes 300 mm dia (salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and directed. |
| 45 | Cutting into existing manholes in running sewage line for connecting new drains of 100 / 150 / 200 / 300 mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required complete all as specified and directed. |
| 46 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to 150mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 47 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed to 200mm bore drain pipes including packing under and haunching against the sides of pipesafter they are laid and tested complete all as specified and directed. |
| 48 | M & L for PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 300 mm bore, after they are laid and tested complete all as specified and directed. |
| 49 | S&F 150 mm bore reinforced cement concrete pipes, class NP 2, laid and jointed with collars complete all as specified and directed. |
| 50 | S&F 200mm bore reinforced cement concrete pipes, class NP 2, laid and jointed with collars complete all as specified and directed. |
| 51 | M&L for 300 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed. |
| 52 | Demolition of plain cement concrete of any description and in any position complete all as specified and directed. |
| 53 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping bed plates, water trough and the like including weathering, slightly rounded or chamfered angles and throating including use of necessary form work and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 54 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in benching, channels and the like including use of necessary moulds, etc. and finishing the surfaces even and smooth with using extra cement complete all as specified and directed. |
| 55 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 56 | M&L for precast cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slabs and the like, set in cement mortar 1:6 with plain fair faces complete with joints to match complete all as specified and directed. |
| 57 | S&F Hight strength, deformed steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.90mm dia all as specified. |
| 58 | Demolition of brick work / stone boulder masonry, built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings etc complete all as specified and directed. |
| 59 | Taking down cement plaster on brick or stone wall, concrete surface etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 60 | M&L for pre-cast cement concrete block masonry with solid blocks, in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 61 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 62 | M&L for road cutting (Bituminous road)/ concrete width not exc 1.0 m upto sub base of road pavement and removing the materials from the site and dumped from the outside MD land.Demolition of plain cement concrete in foundation/copings/ bed concrete of drain pipes in any position complete all as specified and directed.Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. (Rate inculsive of removing of demolition material at outside of MOD land). |
| 63 | Removal of sludge by extra in water, liquid sludge in any positio from septic tank / manholes / grease pit etc of any description, size and depth including cleaning, lifting up and removing sludge and accumulated solid/semi solid sludge and any other foreign materials includig dewateringby using mechanical/tank mounted vehicle capacity not less than 300litres. Sludge and any foreign materials obtained from cleaning shall be removed to distance exceeding 30 KM and burrid in ground to a depth not less than 1.00 mtr incuding removing of covers of any description complete all as specified and directed. |
| 64 | Excavating soft/loose soil in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 65 | M & L for cement concrete (1:2:4) type B2 (using 40 mm graded stone aggregate) in foundation complete all as specified and directed. |
| 66 | S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St-240 complete all as specified and directed. |
| 67 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 68 | S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 69 | M&L for providing cement concrete type C1 1:3:6 (using 20mm graded stone aggregate) in coping and edge of paver block or mud stops, rounded or chamfered on edge complete all as specified and directed. |
| 70 | M&L for preparation of new steel or iron surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 71 | Excavation over areas not exceeding 1.5m deep and getting out in soft / loose soil complete all as specified and directed. |
| 72 | M&L for hardcore of gauge n exc 63 mm with broken stone or boulders depositing spreading levelling in layers n exc 15 cm thick and rammed incl watering etc complete all as specified and directed. |
| 73 | M&L for 100 mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 74 | M&L for sandfor sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 75 | Material & labour for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thicknesswith minimum comp strength of 35 N/sq mm (M-35 Grade)without correction factor forchamfering made in rubber moulds with 0.50 mm thick scratchprooflacquar chemical coating on topsurfaces over with grey cement and pigment laid over and including 20 mm thick compacted thickness sand screed bed complete all as specified and directed. |
| 76 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 77 | M & L for concealed point wiring with PVC insulated and unsheathed multistranded fire retardant low smoke (FRLS) copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawn through heavy duty rigid non metalic PVC conduit not less 20mm dia including all accesories like bend, tess, junction boxes etc with all accessories soutable for moduler type fitmnet including making arrangement for fixing of moduler flush boxes of suitable size complete along with copper earth wire PVC insulated & unsheated multitranded (FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or froof treatment etc and finishing the surfaces with distemper/white washing / colour washing to match with the existing surface complete all as specified and directed. Note: Modular metal boxes will be measured and paid seperately. |
| 78 | (a) One Light point /Fan point controlled by oneswitch |
| 79 | (b)One 3 pin socket outlet 5Amps on the same board with other switches |
| 80 | (c)One 3 pin 5 Amp socket out let controlled by one switch onindependent board |
| 81 | M & L for concealed point wiring with PVC insulated and unsheathed multistranded fire retardant low smoke (FRLS) copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawn through heavy duty rigid non metalic PVC conduit not less 20mm dia including all accesories like bend, tees, junction boxes etc with all accessories suitable for moduler type fitmnet including making arrangement for fixing of moduler flush boxes of suitable size complete along with copper earth wire PVC insulated & unsheated multitranded (FRLS) copper conductor cable of size 2.5sqmm as continous earth wire connected to common earth and erth dolly completeand making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or froof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 82 | All as per item No 2 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 83 | M&L for ceiling rose, 2 to 3 terminal PVC / polycarbonate, isolated body type suitable for AC 230volts complete all as specified and directed. |
| 84 | M & L for module cover plate with frame as per site requirement for following module:- |
| 85 | (a) 3 module |
| 86 | (b) 4 module |
| 87 | (c) 6 module |
| 88 | (d) 8 module |
| 89 | M & L for modular metal flush box as per site requirement. |
| 90 | (a) 3 module |
| 91 | (b) 4 module |
| 92 | (c) 6/8 module |
| 93 | M & L for modular switch 1 way 6 Amp 1 module complete all as specified and directed. |
| 94 | M & L for modular socket 6A 2/3 Pin universal 2 module, complete all as specified and directed. |
| 95 | M & L for modular switch 1 way 16/20 Amp 1 module, complete all as specified and directed. |
| 96 | M & L for modular socket 16A/ 6A 2/3 Pin combined 2 module, complete all as specified and directed. |
| 97 | M & L for modular fan step regulator 100 watt 2 module, complete all as specified and directed. |
| 98 | S&F wall / surface mounted type LED light fitting batten type complete with LED 1x 20Watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 coretwisted flexible copper conductor cable complete all as specified and directed.Make : Philips Cat Part No BN 021C LED 20S PSU CW GR S2 / Havells Cat Part No : ENDURA LINEAR NEO BS 20W LED 865 SPC WH or equivalent make of Wipro. |
| 99 | S & F energy efficient BLDC ceiling fan, 1200mm sweep BEE 5 star rated, AC single phase, 230 volts, 50 Hz, and connecting up including provision of three core flexible copper wire of size 1.5 sqmm from ceiling rose to ceiling fan complete in all respectand all accessories complete all as specified and directed. including taking down old unsv, all as per site requirement. |
| 100 | M&L for sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductorcable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper / white washing / colour washing to match with the existing surface complete all as specified and directed of the following sizes of cables:- |
| 101 | Using two single corePVC insulatedFRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wireNote :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including 20mm PVC casing and cappingshall be measured as one unit |
| 102 | Using two single corePVC insulatedFRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wireNote :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC casing and cappingshall be measured as one unit |
| 103 | M&L for distribution board (DB), double door type as per IEC 61439-3 made out of sheet metal enclosure (CRCA Sheet) dust and vermin proof MCB DB, TPN 4 way with 250 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10KA 01 No 2neutral bar and 2 earth bar IP 43 protection cable ties for cable management (fully insulated busbar and shrouded neutral bars) reversible door for IP 43 , flush (concealed) mounting to wallincludingMCB SP 6 to 32 amp 10KA 12 nos complete all as specified and directed. Note:- Rates are inclusive for flush (concealed) mounted of DB, MCCB 160Amp TPN,MCB SPN 32Amp and 63Amp. |
| 104 | S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, complete all as specified and directed. |
| 105 | Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depthfor foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 106 | Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed. |
| 107 | Material & labour for 50 mm dia bore GI steel tubing light grade for protection of cable / earth continuity conductor fixed to poles / walls / roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and washer etc including taking down old pipe complete all as specified and directed. |
| 108 | M&L for providing dry river sand as in sand cushioning 18cm before and 5 cm after laying of under ground electric cable, thickness specified in SSR Part -I, including punning down of sand in layer complete all as specified and directed. Note: For measurement purpose punned thickness of sand only will be considered. |
| 109 | Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforcedprecast concrete cable coverClass LV, flatof size 250 mm X 150 mm X40 mm in trenches as protection toLT UG cable complete all as specified and directed. |
| 110 | Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected togalvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protectionincluding all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame,with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length |
| 111 | Supply, Installation / fixing, testing and commissioning of room air conditioner unit of 2.0 TR capacity (Split type unit comprising of indoor and outdoor unit) electric driven (single phase230 Volt, 50 Hz) and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rating and EER 3.2, including necessry fixing arrangements complete (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) including metallic bracket with fixing bolts for outdoor unit, insulated piping etc. all as specified and directed including taking down old unsv, complete all as specified and directed. Note: (i) Aircoditioner shall be initial filled/charged with refrigerant of specified quanty. (ii) Additional refrigerant pipes required beyond as supplied by manufacturers deemed to be included in AC rate. (iii) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit. (iv) Split type AC unit to supplied with cordless remote control for operation. (vi) The condensing unit shall be of copper. |
| 112 | Supply, install and testing 5 KVA wall mounted digital voltage stabilizer copper wound for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 220 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity complete all as specified and directed. |
| 113 | Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mts deep below ground level) with top edge of the plate not less than 1.5 mts below normal ground level, connected to Galvanised earth lead strip 25x4 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steeland other end connected to earthing testing point including funnel with watering pipe of 20 mm bore medium grade galvanised iron, wire mesh, charcoal or coke ad common salt in alternate layers of 15cm. (compacted thickness) all around the earth electrode with concrete earth pit in PCC (1:3:6) type C-1,50 mm thick pre-cast RCC M20 nominal mix cover slab of size 450mm x 450mm reinforced with 8 mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary excavation, earth work in any type of soil and disposal of spoil to a distance not exceeding 50 m and necessary testing compete all as shown in Electrical Plate No 5 of MES SSR Part Ias shown on drawingincluding testing on completion and taking out unserviceable one complete all as specified and directed. |
| 114 | Material and labour for replacement of old unserviceable Earthing with new earthing complete with Copper earth plate electrode 600x600x3.15mm thick, burried directly in ground (earth pit not less than 2.25mts deep below ground level) with top edge of the plate not less than 1.5 mts below normal ground level, connected to copper strip as earth lead 20x3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end connected to earthing testing point including funnel with watering pipe of 20 mm bore medium grade galvanised iron, wire mesh, charcoal or coke ad common salt in alternate layers of 15cm. (compacted thickness) all around the earth electrode with concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC M20 nominal mix cover slab of size 450mm x 450mm reinforced with 8 mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary excavation, earth work in any type of soil and disposal of spoil to a distance not exceeding 50 m and necessary testing compete all as shown in Electrical Plate No 5 of MES SSR Part I complete as shown on drawing and as specified including testing on completion all as specified and as directed. |
| 115 | Material and Labour for earth continuity conductor or main earthing lead GI strip 25 mm x 4 mm , burried in ground fixed to wall upto test point on necesarry insulators and fastning screws, rawal plugs etc.any other indicated situation for loop earthing etc complete all as specified and directed.Note: (i) The joints of each lead strip shall be welded/brazed and the cost of brazing/welding shall deem to be included in quoted rate and nothing shall be paid extra on this account. |
| 116 | Material and labour for earth continuity conductor or main earthing lead copper strip 20 mm x 3.15 mm burried in ground fixed to wall upto test point on necesarry insulators and fastning screws, rawal plugs etc.any other indicated situation for loop earthing etc complete all as specified and directed.Note: (i) The joints of each lead strip shall be welded/brazed and the cost of brazing/welding shall deem to be included in quoted rate and nothing shall be paid extra on this account. |
| 117 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete of size 4.0mm dia galvanised iron or steel wire complete all as specified and directed. |
| 118 | Supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long head screw complete all as specified and directed. |
| 119 | S&F GI tubing 20 mm nominalbore, light grade with all fittingsincluding fixing arrangement with screws, clamps on insulator for protection of GI wire upto 1.5 mtrs from G.L. including taking out unserviceable one complete all as specified and directed. |
| 120 | S&F GI tubing 40 mm nominal bore, light grade with all fittingsincluding fixing arrangement with screws, clamps on insulator for protection of GI/copper strip upto 1.5 mtrs from G.L including taking out unserviceable one complete all as specified and directed. |
| 121 | Supply andfixing Exhaust fan, PVC body, heavy duty, AC single Phase, 230V of size 300 mm sweep with, blades, and frame and louverscomplete and other accessories etc complete all as specified and as directed. |
| 122 | Supply andfixing exhaust fan, PVC body, heavy duty, AC single Phase, 230V of size 200/250mm sweep with, blades, and frame and louvers and other accessories etc complete all as specified and as directed. |
| 123 | M&L for point wiring for exhaust fan point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable forPVC type fitment including provision for fixing of PVC boxes of suitable size as per site reqmt complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cableof size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and as directed. |
| 124 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail