| 1 | Supply, installation, testing and commissioning of refrigerator, electric driven, single phase, 230 Volts AC, 50 Hz, Frost free, Double door, copper coil material, energy efficient BEE minimum 3 (three) star rating of minimum capacity 230 Ltrs including refrigerator mounting plastic stand complete all as specified and directed. |
| 2 | Supply, installation, testing and commissioning of refrigerator, electric driven, single phase, 230 Volts AC, 50 Hz, Frost free, Double door, copper coil material, energy efficient BEE minimum 3 (three) star rating of minimum capacity 280 Ltrs including refrigerator mounting plastic stand complete all as specified and directed. |
| 3 | Supply, installation, testing and commissioning of refrigerator, electric driven, single phase, 230 Volts AC, 50 Hz, Frost free, Double door, copper coil material, energy efficient BEE minimum 3 (three) star rating of minimum capacity 300 Ltrs including refrigerator mounting plastic stand complete all as specified and directed. |
| 4 | Supply, installation, testing and commissioning of refrigerator, electric driven, single phase, 230 Volts AC, 50 Hz, Frost free, Double door, copper coil material, energy efficient BEE minimum 3 (three) star rating of capacity minimum 310 Ltrs including refrigerator mounting plastic stand complete all as specified and directed. |
| 5 | Supply, installation, testing and commissioning of Deep Freezer, single phase, 230 Volts AC, 50 Hz, hard top (Double Lid), minimum 300 Ltr Net Storage capacity, usingeco-friendly R290 refrigerant, with digital temperature display, leather coated PCM sheet internal liner, flexible cooling range +10°C to -31°C, featuring internal LED light, 70 mm high-density PUF insulation, and sturdy mounting stand; unit must be minimum 3 star BEE rated for energy efficiency and include integrated lock, complete all as specified and directed. |
| 6 | Supply and fixing water cooler electric driven, Single phase, 230 volt AC, 50 Hz having approx storage capacity of 150 litres and nominal cooling capacity of 150 litres/hour, double faucets(cold), fully stainless steel body and tank, Hermetic type compressor, propeller type fan condenser, automatic thermostat, aesthetic & compact design, with auto shut off, ISI mark, suitable for eco friendly refrigerant R-134a/R-290, PUF insulation for longer cooling period, complete including provision of mounting stand suitable for water cooler etc., complete all as specified and as directed. |
| 7 | Supply and fixing water cooler electric driven, Single phase, 230 volt AC, 50 Hz having approx storage capacity of 80 litres and nominal cooling capacity of 40 litres/hour, double faucets(cold), fully stainless steel body and tank, Hermetic type compressor, propeller type fan condenser, automatic thermostat, aesthetic & compact design, with auto shut off, ISI mark, suitable for eco friendly refrigerant R-134a/R-290, PUF insulation for longer cooling period, complete including provision of mounting stand suitable for water cooler etc., complete all as specified and as directed. |
| 8 | Supply, installation, testing and commissioning of 1.5 TR Inverter Split Type Air Conditioner; minimum BEE 5-star rating; electric driven single phase, 230 Volt, 50Hz AC; equipped with cordless remote control and high-efficiency particulate (PM 2.5) filters; including all necessary fixing arrangements as per relevant IS standards; outdoor unit to be mounted on metallic brackets with anchor bolts on plinth, wall, or roof as directed; including making good of disturbed surfaces with cement mortar 1:3 or concrete 1:2:4; including insulated copper piping, PVC drain pipes, and all electrical interconnections, complete all as specified and directed. |
| 9 | Supply, installation, testing and commissioning of 2.0 TR Inverter Split Type Air Conditioner; minimum BEE 5-star rating; electric driven single phase, 230 Volt, 50Hz AC; equipped with cordless remote control and high-efficiency particulate (PM 2.5) filters; including all necessary fixing arrangements as per relevant IS standards; outdoor unit to be mounted on metallic brackets with anchor bolts on plinth, wall, or roof as directed; including making good of disturbed surfaces with cement mortar 1:3 or concrete 1:2:4; including insulated copper piping, PVC drain pipes, and all electrical interconnections, complete all as specified and directed. |
| 10 | Supply, installation, testing and commissioning of 2.5 TR Inverter Split Type Air Conditioner; minimum BEE 5-star rating; electric driven single phase, 230 Volt, 50Hz AC; equipped with cordless remote control and high-efficiency particulate (PM 2.5) filters; including all necessary fixing arrangements as per relevant IS standards; outdoor unit to be mounted on metallic brackets with anchor bolts on plinth, wall, or roof as directed; including making good of disturbed surfaces with cement mortar 1:3 or concrete 1:2:4; including insulated copper piping, PVC drain pipes, and all electrical interconnections, complete all as specified and directed. |
| 11 | Supply, installation/fixing, testing and commissioning of Window AC of 1 TON capacity; energy efficient design with minimum 3-star rating and Inverter compressor; features including multi-mode cooling (e.g., 4-in-1 or similar), anti-corrosive protective coating on copper coils for enhanced durability, and R32 refrigerant; including providing and fixing of wooden/metallic frame in the window opening, sealing of gaps with high-density foam/silicon, and making good of disturbed masonry or carpentry surfaces; complete all as specified and directed. |
| 12 | Supply, installation/fixing, testing and commissioning of Window AC of 1.5 TON capacity; energy efficient design with minimum 3-star rating and Inverter compressor; features including multi-mode cooling (e.g., 4-in-1 or similar), anti-corrosive protective coating on copper coils for enhanced durability, and R32 refrigerant; including providing and fixing of wooden/metallic frame in the window opening, sealing of gaps with high-density foam/silicon, and making good of disturbed masonry or carpentry surfaces; complete all as specified and directed. |
| 13 | Supply and fixing ceiling fan complete with aluminium blades, down rods with canopy & Each all accessories 230V, 1200 mm sweep copper winding, Min air delivery 210 CMM with service value 6.00 BEE,5 star rated with brush less direct current motor (BLDC), complete all as specified and directed. |
| 14 | Supply and fixing exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades, frames & louvers, complete all as specified and directed. |
| 15 | Supply and fixing exhaust fan steel body AC single phase 230 V of size 450 mm sweep with blades, frames & louvers, complete all as specified and directed. |
| 16 | Supply and fixing exhaust fan made with of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 50 HZ, RPM 1200, copper winding of sweep 250 mm, complete all as specified and directed. |
| 17 | Notes for items 1 to 16 above:a)By submitting a bid, the contractor certifies that they have verified the current market availability of all specified technical features. Any claim regarding \"discontinuation\" or \"non-availability\" raised after the award will be treated as a default by the contractor. In such cases, the Department reserves the right to accept a modern equivalent at a reduced rate determined by the Department\"s engineer-in-charge and approved by the accepting officer, whose decision shall be final and binding.b) If a specified feature is unavailable and a lower physical specification (e.g., fewer faucets, lower capacity, lower star rating) is accepted by the Department to maintain project timelines, the payment shall be made at rates arrivedafter deducting 10% of quoted rate from the lesser of (i) contractor\"s quoted rate and (ii) Market rate prepared in terms of condition 62E of IAFW 2249.The 10% penalty reduction shall be for non-adherence to Note (a) above.c) In case of non-availability of specified capacity, the next higher available capacity must be provided by the contractor at no extra cost to the department. Supply of lower capacity will be rejected.d) The features mentioned (e.g., specific coatings/filters) are performance benchmarks. The contractor is free to provide any equivalent technology subject to prior approval of accepting officer from the make-list that meets or exceeds these performance standards at the quoted rate. |