| 1 | Dismantling of Ductile iron/ cast iron or reinforced concrete drain pipes, of size 150/200mm dia jointed in cement mortar and taking out from RCC OH reservoir, andremoving materials and rubbish off the premises complete all as specified and as directed. |
| 2 | Supply, laying, jointing, commissioning & testing of ductile iron water mains 200mm bore with flanged ends centrifugally cast of class K-9, and wall thickness 6mm and conforming to IS \"8329\"(2000) complete all as specified and directed(Note:- Rubber gasket joints and DI specials/fittings shall be measured and paid separately) |
| 3 | Supply, laying, jointing, commissioning & testing of ductile iron water mains 150mm bore with flanged ends centrifugally cast of class K-9, and wall thickness 6mm and conforming to IS \"8329\"(2000) complete all as specified and directed(Note:- Rubber gasket joints and DI specials/fittings shall be measured and paid separately) |
| 4 | Supply and replace DI/GI specials from 150mm to 450mm bore such as bends(any type, radius and angle)tapers any type, Tee equal/unequal with flanged and socket or in any combination in any length as per site requirement, tail piece straight,bend,increasing,decreasing or double socket etc.) tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs including ring washer gaskets all as specified and directed. Note: (i) Cutting main pipeline before inserting DI/GI fittings for making branch connections also deemed to be included in quoted rate. |
| 5 | Replacing MS nuts, bolts , washer & MS flat, machine cut, hexagonal 5cm to 10cm long, dia meter of neck 16 to 24mm or existing size as per site requirement and complete. |
| 6 | Supply and fixing galvanised steel water tubing medium grade 100 mm bore including all necessary fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc, laid in trenches including inter connection between buildings/pumps/pump houses and taking out old existing GI tubing complete all as specified and as directed. |
| 7 | Supply and fixing galvanised steel water tubing medium grade 80 mm bore including all necessary fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc, laid in trenches including inter connection between buildings/pumps/pump houses and taking out old existing GI tubing complete all as specified and as directed. |
| 8 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed. |
| 9 | Material and labour for 10 mm thick renderingon brick/concrete surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | Supply and fix in repairs 1.6mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 11 | M&l for Preparation ofold untreated/ new surface of pipes any description n.exc 60 cm girth including holder bats, distance pieces etc (length measured over bends, branches etc), priming with 2 coats of red oxide zinc chrome primer and painting of synthetic enamel paint (ordinary tint) x 2 coats complete all as specified and directed by Engr-in-Charge. Note: Not reachable portion/bottom side of pipeline shall be dismantled and then re-fitted at its position after completion of primer and painting without any extra cost. |
| 12 | M&L for complete removal by Washing, rubbing down and stopping and preperation of distempered and painted surfaces of walls, pillars,cornices by brooming down etc and applying twocoats of distemperoil emulsion over a coat of primer complete all as specified & directed. |
| 13 | M&L for complete removal of old distempered and paintedsurfaces including washing, rubbing down and stopping by brooming down , scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying twocoats of distemperoil emulsion over a coat of primer on ceiling surfaces, complete all as specified and directed. |
| 14 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 15 | M&L for MS Angle framed work by using Fe 410W (Gde -E- 250, quality A) as in doors (pit cover) of gates or other sections complete drilled for fixing of steel sheets or other covering to be prepared for hanging or one side opening including hooks or hinges or steel hanging door fittings (exclusive of steel sheets) also fastening and fixing complete. (desired dimension of the angle shall not be less than 50mm x 50mm x 5mm thick) |
| 16 | M&L for mechanical water level indicator in RCC overhead reservoir, type float and board level indicator, aluminium plate, black and white painted level lines, steel rope and float suspended weight suitable for height upto 2 mtr or as per ground including fixing on wall complete. Location: RO plant RCC water storage reservoir Make : Petrotech Engineers or ISI make complete all as specified and directed.Note: (i) Width of aluminium board and dimension of letters and line should be designed in such a manner that water level should be legible from the ground level. Approx height of reservoir is 20Mtr. |
| 17 | M&L for mechanical water level indicator in RCC overhead reservoir, type float and board level indicator, aluminium plate, black and white painted level lines, steel rope and float suspended weight suitable for height upto 4 mtr or as per ground including fixing on wall complete. Location: RO plant RCC water storage reservoir Make : Petrotech Engineers or ISI make complete all as specified and directed.Note: (i) Width of aluminium board and dimension of letters and line should be designed in such a manner that water level should be legible from the ground level. Approx height of reservoir is 20Mtr. |
| 18 | M&L for mechanical water level indicator in RCC overhead reservoir, type float and board level indicator, aluminium plate, black and white painted level lines, steel rope and float suspended weight suitable for height upto 8 mtr or as per ground including fixing on wall complete. Location: RO plant RCC water storage reservoir Make : Petrotech Engineers or ISI make complete all as specified and directed.Note: (i) Width of aluminium board and dimension of letters and line should be designed in such a manner that water level should be legible from the ground level. Approx height of reservoir is 20Mtr. |
| 19 | S&F in replacement LED Aviation light die-cast aluminium housing with red polycarbonate dome for better illumination, integral driver, ingress protection: IP 65, including taking down old unserviceable light all as specified and directed. Make- Bajaj Cat part No. BGAV 302 LED or equivalent model in Philips/ Crompton/Havells as approved by GE. |
| 20 | Supply laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 Volt grade all as specified and directed. |
| 21 | S&F rigid non-metallic PVC conduit pipe 32mm dia including all tees, bends, elbows, bell mouth, reducers etc and all fixing accessories on wall such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engr-In-Charge. |
| 22 | Supply & fixing Air termination rod, single pointed, copper rod 12mm dia and 300mm long complete all as specified & directed |
| 23 | Earthing complete with GI earth plate electrode 600x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge not less than 1.5 m below ground level connected with GI earth wire of 4 sqmm by means of bolts, nuts, check nuts and washers as shown in electrical plate No. 3 connected to earthing test point all asspecified or indicated including testing on completionall as specified & directed .Notes:Quoted rates shall be deemed to be included the following (a) Excavation ,RFR earth workin any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1, pre cast RCC cover40 mm thick in PCC 1:2:4type B-1, with suitable handle reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm.(c) funnelwith wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed. (d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified & directed. (e) Requisite quantity of common salt and charcoal in alternative layers as specified. |
| 24 | M&L for copper strip of size 25x4mm fixed on epoxy earth strip insulator of size 25x3.15mm including fixing screws and fasteners for roof conductors and down conductors above ground level and fixing complete all as specified and directed. |
| 25 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregateas in sub base of floors including necessary form work all as specified and as directed. |
| 26 | Material and labour for 25mm thick plain cement concrete over sub-base, 1:2:4 type B1using 20 mm graded stone aggregate as in as in leveling course including use of form work as necessary, screed strips and to divide the area in panels etc completeall as specified and as directed. |
| 27 | Supply fixing and testing CI sluice valve cast iron body (Long body) of size 250 mm dia PN 1.6 conforming to IS-14846 flanged end, spur gear and hand operation, ISI marked having brass spindle with iron wheel at top, with nuts bolts and washers rubber gasket etc complete all as specified and directed. |
| 28 | Supply fixing and testing CI sluice valve cast iron body (Long body) of size 150 mm dia PN 1.6 conforming to IS-14846 flanged end, spur gear and hand operation, ISI marked having brass spindle with iron wheel at top, with nuts bolts and washers rubber gasket etc complete all as specified and directed. |
| 29 | Supply fixing and testing CI sluice valve cast iron body (Long body) of size 100 mm dia PN 1.6 conforming to IS-14846 flanged end, spur gear and hand operation, ISI marked having brass spindle with iron wheel at top, with nuts bolts and washers rubber gasket etc complete all as specified and directed. |
| 30 | Supply and fixing cast iron Butterfly valve of 100mm dia,flanged, bonnet wedge stuffing box, gland trust plate, hand weel CI with brass spindle, washer & nut bolt including jointing,Class PN 10, complete all as specified and directed at site by the Engineer-in-incharge. |
| 31 | Supply and fixing cast iron Butterfly valve of 80mm dia,flanged, bonnet wedge stuffing box, gland trust plate, hand weel CI with brass spindle, washer & nut bolt including jointing,Class PN 10, complete all as specified and directed at site by the Engineer-in-incharge. |
| 32 | Note for all items of this Schedule :- The work shall be executed to high rise structure (ie.Overhead Water Tank) of height up to 20 metre(Aprox) from ground level. Quoted rate shall be deemed to including for all kind of Scaffolding and safety equipment provided to worker deployed by the contractor and no extra amount paid by the department for the same and the work shall be carried out without any damage to the existing structure. Any damage occured due to contractor shall be rectified without any extra cost to the Goverment. |
| 33 | Schedule of Credit (Minus) Rs.32115.00NOTE: Bidder shall insert credit amount ofRs. 32115.00 as ratein Green field under Col-13. |