| 1 | Sub heading 1 |
| 2 | Clearing grass and removal of the rubbish up to a distance of 50mtr. outside the periphery of the area cleared. |
| 3 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead 1:3:6 or richer mix |
| 4 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead: In Cement mortar |
| 5 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 6 | Demolishing cement concrete/ brick tile covering in terracing of 40mm thickness including stacking of serviceable material if any and disposal of unserviceable material within 50 metres lead |
| 7 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls up to 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in- charge to required slope and treating similarly the adjoining walls up to 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq. 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in- charge: With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 8 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 9 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 10 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion: (i) Single socketed pipes 110 mm diameter |
| 11 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams |
| 12 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 100 metres lead : Of area beyond 3 sq. metres |
| 13 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge: All kinds of soil |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift |
| 15 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work up to plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: ThermoMechanically Treated bars of grade Fe-500D or more. |
| 20 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 23 | Providing & Fixing Corrugated Stone-Texture CGI Sheets (heritage look) of approved profile, minimum 0.50 mm base metal thickness (or as approved), with factory-applied corrosion-resistant coating and stone-texture finish, on walls/approved surfaces, including all necessary self-drilling/self-tapping screws with concealed or heritage-finish heads, washers, fixtures and accessories, complete. The CGI sheets shall be cut, shaped and fixed in true line, level, plumb and plane, maintaining uniform corrugation pattern and joint alignment, and shall be fixed directly to the wall surface and/or to a light-gauge supporting framework, wherever required. |
| 24 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately): Size of tile 1000x1000 mm |
| 25 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge: Size of tile 1000x1000 mm |
| 26 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 coarse sand) |
| 27 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 28 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 29 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate |
| 30 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 31 | Relaying of sandstone pathway over thick base of cement mortar 1:5 (1 cement : 5 coarse sand) |
| 32 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge: Upto and including 12 mm dia. |
| 33 | Providing & fixing aluminium doors (swing type) and windows of approved make and system, powder coated (minimum 50 microns), fabricated from aluminium extruded sections of approved profile and minimum 1.2 mm thickness, including glazing with approved laminated toughened glass of minimum 8 mm thickness, EPDM gaskets, weather strips, corner cleats, beading, screws, shims, packers, stainless steel/anodised aluminium fixtures and fittings such as hinges, handles, locks, stays, door stoppers, fasteners and all necessary hardware, fixed in true line, level and plumb, complete, in consultation with site in-charge. |
| 34 | Providing & fixing revolving chairs of Green Soul make or equivalent, ergonomically designed, with pneumatic height adjustment mechanism, swivel base, cushioned seat and backrest with breathable fabric/mesh upholstery, arm rests, sturdy base with castors, suitable for office/museum use, including all necessary fittings and accessories, complete, with a minimum 1-year warranty, as per approved design, specifications and instructions of Engineer-in-Charge, in consultation with site in-charge. |
| 35 | Providing & fixing wooden benches for indoor use, consisting of seasoned hardwood / BWR-grade plywood seating and backrest with smooth edges, finished with melamine / PU polish, supported on a rigid mild steel (MS) framework fabricated from MS sections, including cutting, welding, grinding, application of zinc primer and finished with two or more coats of approved enamel / epoxy paint, complete with all necessary nuts, bolts, fasteners and floor fixing arrangements. The benches shall provide seating for 4 or more persons, with dimensions and layout as per site conditions, and as per approved design, drawings, and directions of Engineer-in-Charge, in consultation with site in-charge. |
| 36 | Finish – Providing and fixing laminate console in knockdown assembly made of 18 mm thick BWP grade plywood, finished with approved decorative laminate (minimum 1.0 mm thick, 1.2 mm for horizontal surfaces where required), bonded with approved adhesive. All exposed edges to be machine edge-banded with PVC edge band of approved make. Wooden components to be treated with approved anti-termite chemical. Hardware fittings to be soft-close type of approved make. Complete installation and finishing as per approved design and in consultation with site in-charge. |
| 37 | Finish – Providing and fixing glass display for artifacts using 8 mm thick clear toughened glass with polished edges, including necessary framing, locking arrangement, and concealed low-heat LED lighting with concealed wiring. Display to be dust-proof with proper sealing and non-corrosive fittings, suitable for conservation requirements. Include provision for adjustable/fixed glass shelves made of 6 mm thick clear toughened glass with polished edges, resting on non-corrosive supports as per approved design. Display to be properly supported and anchored to the laminate plywood cabinets below, ensuring seamless integration, stability, and dust-proofing. All displays and shelving to be designed and customized in accordance with the size, shape, and layout of the site sculptures, in consultation with the site in-charge. Complete with all accessories, as per approved design. |
| 38 | Providing & fixing wall-mounted display / interpretation panels for exhibition purposes, made of BWR-grade plywood, with printed graphics, text and images as per approved content and design, including necessary framing, supports and fixing to walls, complete with non-glare protective laminate / acrylic covering and edge finishing, suitable for indoor use, complete in all respects, as per approved design and directions of Engineer-in-Charge, in consultation with site in-charge. |
| 39 | All Weather Inverter Split AC with Intelligent Heating AC, 2 Ton / Hot & Cold AC - The work shall include supply of all the auxiliary items related with installation such as Stand, Copper pipe, wire and other fitting materials but will not be restricted to the same and may include any additional items that are necessary for such installation. The work shall include carriage, loading, unloading, transportation, all labour works related with supply/purchase and installation of the air conditioners.a. Air Conditioner, which is offered by the tenderer, shall carry a five star rating or shall be of inverter type & only of a reputed Brand. b. The product on offer shall carry a minimum warranty period of one year; c. The compressor of the air conditioners should carry a minimum warranty of five year. d. Product on offer shall carry a free replacement guarantee period of a minimum 21 days in case the supplied product is found to be carrying a manufacturing defect or is a malfunctioning unit. e. There should be an authorized service centre of the offer product in Udhampur. |
| 40 | SITC of new connection from existing transformer to the internal distribution board, including supply, laying, fixing, testing, and commissioning of all required cables and bus ducts with terminations, cable glands, lugs, clamps, supports, protection devices such as isolators, fuses, and relays. Includes installation of a 5 kVA stabilizer and earthing arrangements with a 600 mm × 600 mm earthing pit, using copper electrodes and copper conductor connections as per approved design and in consultation with Site In-charge. Testing, commissioning all included. |
| 41 | SITC of complete electrical installations for exhibit lighting, including supply, laying, fixing, testing and commissioning of all point wiring for light points, plug points, exhaust fan points, call bell points and control points using FRLS PVC insulated copper conductors of suitable sizes in surface/recessed steel conduit, including circuit and sub-main wiring, loop earthing, GI/MS boxes, modular switches, socket outlets, conduits and accessories;Supply and installation of lighting fixtures such as ceiling-mounted lights, track lights with metal tracks, spot lights, wall washer lights and associated fittings of approved make;Complete in all respects, including fixing, interconnections, testing and commissioning, with lighting layout based on approved concept drawings and adapted to actual site conditions. The contractor shall submit final design for approval prior to execution.Execution shall be carried out on a composite lump-sum basis, as per approved design and directions of Engineer-in-Charge, in consultation with Site In-charge. |
| 42 | Supplying, installation, testing and commissioning of DG sets, AMF panel, bus ducting/ cables from DG sets to essential panel, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney asper CPCB norms, civil works connected with DG sets including foundation as required. @ 11560 per kVA - as per approved design, in consultation with site in-charge |
| 43 | Supplying, installation, testing and commissioning of IP-based CCTV system for indoor building security, comprising PTZ and/or fixed IP cameras, complete with all necessary accessories including mounting arrangements, power supply, structured cabling, network components, recording and storage system (NVR with required hard disks), display/monitoring system, configuration of hardware and software, integration with local network, and provision of system testing, commissioning and operational support, complete in all respects as required, with one year warranty of all components included |
| 44 | For supplying, installation, testing and commissioning of IP-based external CCTV surveillance system, comprising suitable outdoor-rated IP cameras (fixed/PTZ, as required) with day/night functionality, IR illumination, weatherproof housings, mounting arrangements, structured cabling (including outdoor-grade conduits), network components, recording and storage integration with central system, power supply arrangements, configuration of hardware and software, system testing and commissioning; rate applicable on net open plot area (total plot area excluding plinth area at ground floor) @ ₹210 per sqm, as per approved design and layout, complete in all respects, in consultation with and as directed by the Site In-charge, with one year warranty of all components included |
| 45 | Providing & supplying VR headset with inbuilt headphones, standalone unit benchmarked on Meta Quest (512 GB) or equivalent, suitable for Museum / Interpretation Centre use, supporting immersive VR and multimedia content.The headset shall feature a high-resolution display (~2064 × 2208 pixels per eye), Snapdragon XR2 Gen 2 processor with ~8 GB RAM, inside-out tracking, integrated hand controllers, and ergonomic lightweight design for repeated visitor use.Includes all necessary cables, adapters, chargers, software licenses, protective casing/face interface, and user manuals, complete for operation.Shall comply with relevant safety and electrical standards, and be provided including installation, configuration, testing, and demonstration, with a minimum 2-year comprehensive manufacturer warranty, as per approved design and instructions of Engineer-in-Charge, in consultation with site in-charge. |
| 46 | Supply, Installation, Testing & Commissioning of VR-ready Workstation for Museum Applications, desktop form factor, make Dell / HP / Lenovo or equivalent approved, with minimum 3 years OEM onsite warranty, equipped with 13th / 14th Generation Intel Core i7 processor or equivalent, minimum 16 GB DDR5 RAM (expandable to 32 GB), minimum 1 TB NVMe SSD, and NVIDIA RTX-series graphics card with minimum 6 GB VRAM, suitable for smooth and continuous Museum VR operation.The workstation shall run genuine Windows 11 Pro (64-bit) and include adequate I/O ports (USB, HDMI/DisplayPort, audio), PCIe x16 expansion slot, minimum 650-Watt power supply (80+ Bronze or better), Gigabit LAN, Wi-Fi and Bluetooth connectivity.Complete with 24-inch LED monitor, wired keyboard & mouse, USB soundbar / speaker, and installation, configuration and demonstration of Museum VR software in working condition, as per approved design, in consultation with site in-charge. |
| 47 | Supplying, installation, testing and commissioning of rack-mounted server, comprising Intel i5 processor or equivalent, minimum 32 GB RAM, minimum 256 GB SSD storage (with provision for expansion), pre-loaded with licensed Windows Server OS or latest approved operating system, suitable rack-mount form factor with rails, redundant cooling, network interface cards, power supply arrangement and all required accessories; complete with configuration and integration with the complete IT system including CCTV/VMS, access control, networking and monitoring infrastructure, system testing and commissioning, three (03) years comprehensive on-site warranty |
| 48 | Providing & supplying 2 units of 4 KVA UPS with minimum 2 hours battery backup, one for Technical use and one for Interpretation Centre, of Luminous, Microtek, or any other reputed brand, including all necessary batteries (minimum 12 V, 150 Ah each), battery connectors, cables, distribution boards, indicators, mounting arrangements, and user manuals, complete, as per approved design, specifications and instructions of Engineer-in-Charge, in consultation with site in-charge. The UPS shall provide stable, uninterrupted power supply, be compatible with connected equipment, and comply with relevant electrical and safety standards. The system shall be covered under a minimum 2-year comprehensive warranty against manufacturing defects and malfunctions. |
| 49 | 65” 4K LED TV/Monitor, HDMI, 16:9 aspect ratio, minimum 03 years warranty (LG / Samsung), along with compatible soundbar of minimum 300 W output of the same make as TV, as per approved design, in consultation with site in-charge, inclusive of all fixtures, fittings, mounting/hanging system, hardware, electrical connections, accessories, and any electrical, mechanical or other mechanism required to make the complete system fully functional. |
| 50 | Headphones for Digital Screen, over-ear type, lightweight (approx. 200 g), stereo sound with frequency response 20 Hz–20 kHz, dynamic drivers, Active Noise Cancellation with ambient sound mode, suitable for multimedia/interpretation content, with 3.5 mm audio jack and/or Bluetooth (v5.2 or higher), integrated microphone and on-device controls, rechargeable battery with minimum 30 hours playback, USB Type-C fast charging, compatible with laptops and digital display systems, of Sony / JBL / Bose or equivalent approved make, with minimum 01 year manufacturer’s warranty, as per approved design, in consultation with site in-charge, inclusive of all accessories, cables/connectors and all requirements to make the system complete and fully functional. |
| 51 | SITC of Laser Type Projector of minimum 10,000 ANSI lumens (white & colour brightness), 16:9 aspect ratio, UHD/4K resolution, with minimum laser light source life of 20,000 hours, minimum ports comprising 1 x HDMI, 1 x D-Sub (VGA), 1 x 3.5 mm audio jack, 1 x HDBaseT (RJ-45) for video over CAT-6 / twisted pair, 1 x LAN (RJ-45) or wireless connectivity for configuration, and 1 x USB or RS-232 for control, complete with suitable zoom and lens shift to suit site conditions and compatible with AV control systems. |
| 52 | Providing and installing of Pre-fabricated Toilet cabin (disabled friendly) of approved brand and manufacture of size 7\"x8\" floor area and 8ft internal height with all roof work of standard design and make, including cost of urinal bowl, railing WC, other sanitary & electrical fittings, foundation work of 1:2:4 cement concrete upto 45cm with all plinth work, ramp with railings (1:12 slope) for access to toilet cabin, including transportation, overhead charges, all complete (the certificate testing may be provided in this). |
| 53 | Providing and fixing of Weatherproof, UV-resistant, antislip 300mm x 300mm x 7mm sized butyl directional and warning tactile tiles to be fixed with self-adhesive tape including installation - as per approved design, in consultation with site in-charge |
| 54 | Providing of 1.2 m wide wooden ramp with Stringers 40×40×3 mm MS square tube, Cross members 40×6 mm MS flat, Handrails SS pipe 304 grades with press fit technology as per JIS 3448 standard 42.70 mm outer dia, Wooden planks of Second class kail wood, nails, screws, fitting, labour charges all complete.- as per approved design, in consultation with site in-charge |
| 55 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 56 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 57 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 59 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |