| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 2 | Group C |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 4 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 8 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 20 mm. |
| 11 | 25 mm. |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC casing caping asrequired. |
| 13 | 3 x 1.5 sq. mm. |
| 14 | 3 x 4 sq. mm. |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing following way, Horizontal/Verticaltype SPN / TPN, sheet steel, MCB distribution board, 240/ 415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 19 | 8 Way SPN Double Door |
| 20 | Supplying and fixing following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 21 | 5 amps to 32 amps, 240 volts Single pole. |
| 22 | 5 amps to 32 amps, 240 volts Double pole. |
| 23 | Supplying and fixing DP sheet steel enclouser on surface /recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 24 | Supplying Installation, testing and commissioning of following pre-wired,surface / recess mountedLED light fixtureof all types, complete with all accessories, with integrated electronic driver , and lamps etc.,suitable for operation on 230 Volts, 50Hz, Single Phase, includingconnection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cableand earthing etc. as required. |
| 25 | 600mm x 600mm (Nominal dimension) size ,36 Watt, recessed mounted LED Luminaires inMetallic CRCA Powder Coated Housing, High efficiency Diffuser & integrated electronic driver provides uniform illumination and suitable for office applications. (M/s. Bajaj make Model BZRSQL 36L LED GX WH or Similar Superior model of preferred make). |
| 26 | 300mm x 1200mm (Nominal dimension) size ,36 Watt, recessed mounted LED Luminaires inMetallic CRCA Powder Coated Housing provides uniform illumination and suitable for office applications. (M/s. Bajaj make Model BZRSLL 36L LED GX WH SD or Similar Superior model of preferred make). |
| 27 | 18 wattpre-wired, recess mounted/pendant round LED panel cool white light fixture suitable for operation on 230 Volts, 50 Hz, Single Phase etc. as required. (M/s. Bajaj make Model BZSLO nxt 18L LED WH SD or Similar Superior model of preferred make). |
| 28 | Supply, installation, testing, and commissioning of 4-feet, 20W (±2W) energy-efficient linear box-type LED batten light, Pure white( 6500K) , minimum luminous output of 1900 lumens andluminous efficacy of 95 lumens/watt, suitable for operation on 230V, 50Hz, single-phase AC supply complete with all necessary accessories,connection with 1.5 sqmm copper conductor FRLS PVC insulated cable etc. as required. (Make: M/s Havells / SYSKA / Wipro / Crompton / Bajaj / Osram or other similar superior make and model). |
| 29 | Providing and fixing 400 mm. sweep quick start, high torque and full copper motor, wall mounted fan havingspeed regulation with double pull cord and suitable for operation on single phase, 230 volts, 50 Hz AC supply with all accessories as reqd. (M/s. Bajaj make model- Esteem 400 mm white or Similar Superior model of preferred make). |
| 30 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 31 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 32 | 3 Module (100mmX75mm) |
| 33 | 8 Module (125mmX125mm) |
| 34 | 12 Module (200mmX150mm) |
| 35 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 36 | 5/6 amps switch |
| 37 | 15/16 amp switch |
| 38 | 3 pin 5/6 amp socket outlet |
| 39 | 6 pin 15/16 amp socket outlet |
| 40 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc. as required. |
| 41 | Replacement/providing & fixing of the following old & obsolete items i/c connections, testing & commissioning etc. complete as required:- |
| 42 | Plastic round sheet for covering of junction/fan box. |
| 43 | 6 mm thick Phenolic sheet |
| 44 | Dismantling of Existing one no 1.5 /2.0 TR Window/Split /High Sensible Split Air Conditioner unit complete with Indoor and Outdoor unit , Stand, Piping, Cable on MS tray / Wall, Removing existing Distribution Board, MCBs, Timers, (Pump down of refrigerant) andassociated items and cleaning of indoor & out door units, making good the damage,minor civil worketc.as required. |
| 45 | Installation, Testingand commissioningof wall mountedSplit AC unit upto 2.0 TR capacity complete with indoor and outdoor units , installation of outdoor Condenser unit on existing M.S. stand, indoor unit on existing wall, providing nut bolts, making adequate hole in the wall for entry of copper pipes/tray, closing of holes, air gaps etc. after installation making testing commissioning etc. complete as reqd i/c fixing of existing Copper refrigerent piping brazing, leakage test ,Wet servicing of Window / Split AC unit greasing of Fan motor, replacement of bush/bearing of fan / blower Motor, cleaning of condenser coil with caustic soda, washing of filters i/c removing and refixing AC unit, testing complete etc. as reqd. |
| 46 | Providing and Wrapping of expanded polyethylene foam tube (heat lon) insulation on the existing refrigerent piping complete with clamping etc. as reqd. |
| 47 | For 1/2” Copper refrigeration pipe |
| 48 | For 1/4” Copper refrigeration pipe . |
| 49 | Supply & Fixing following size copper refrigerent pipes if required at site I/c cutting, bending, brazing etc. complete as reqd during installation. |
| 50 | 1/2” Copper refrigeration pipe |
| 51 | 1/4” Copper refrigeration pipe . |
| 52 | Supplying andCharging of fresh refrigerant in the existing 1.5 TR Split AC unitsof including Vacuum testing, Pressure/ leakage testing of referigerant Circuit and arresting the same if anyby brazing / flaring the leak points i/c vacuumization, complete as per manufacturer/departmental specifications, etc as required at site. |