| 1 | Replacement/fixing of following PVC casing and capping with equivalent on surface including tee, elbow, bend, coupling, corners, screws, nails, nylon plugs etc as required. |
| 2 | 12/15 mm x 10mm |
| 3 | 20mm x 10mm |
| 4 | 32mm x 10mm |
| 5 | 40mm x 10mm |
| 6 | Replacement/ fixing of following size of Rigid PVC pipes with equivalent along with the accessories in surface including tee, elbow, bend, coupling, SS screws, nails, nylon plugs etc as required. |
| 7 | 15mm |
| 8 | 20mm |
| 9 | 25mm |
| 10 | Replacement/ fixing of following size of PVC including FR grade cables of reputed brand |
| 11 | 1 Sqmm |
| 12 | 1.5 Sqmm |
| 13 | 2.5 Sqmm |
| 14 | 4 Sqmm |
| 15 | 6 Sqmm |
| 16 | Replace with PVC insulated PVC sheathed flexible copper cable size 4x16 sqmm |
| 17 | Replacement/ fixing of PVC with equivalent of the following size on surface including S.S screws, nails, nylon plugs etc required. |
| 18 | 4\"x4\" (100x100mm) |
| 19 | 6\"x4\" (150x100mm) |
| 20 | 8\"x4\" (200x100mm) |
| 21 | 10\"x4\" (250x100mm) |
| 22 | 10\"x8\" (250x200mm) |
| 23 | 12\"x4\" (300x200mm) |
| 24 | 12\"x10\" (300x250mm) |
| 25 | Replacement / fixing of Hylum cover / PVC with equivalent of the following size on the existing PVC boxes including cutting drilling with S.S screws and washers etc required. |
| 26 | 4\"x4\" (100x100mm) |
| 27 | 6\"x4\" (150x100mm) |
| 28 | 8\"x4\" (200x100mm) |
| 29 | 10\"x4\" (250x100mm) |
| 30 | 10\"x8\" (250x200mm) |
| 31 | 12\"x4\" (300x100mm) |
| 32 | 12\"x10\" (300x250mm) |
| 33 | Replacement / fixing with equivalent of following type of bells & bell indicators including connections as required. Brands of GM, Philips, etc |
| 34 | Call bell |
| 35 | Ding Dong bell |
| 36 | Remote control electric bell |
| 37 | Replacement / fixing of earthing with G.I pipe 32mm dia 2.5m long including accessories, nut and bolt washer etc complete as required. |
| 38 | Replacement / fixing equivalent of plates for the following modular boxes on the existing box complete with shutter, top cover etc including screws etc as required. |
| 39 | 1 Modular |
| 40 | 3 Modular |
| 41 | 4 Modular |
| 42 | 6 Modular |
| 43 | 8 Modular |
| 44 | 12 Modular |
| 45 | Replacement / fixing with equivalent of the following Modular switches, sockets, blank plates, etc are on the existing switch box / cover including connections etc. |
| 46 | 2 Modular 32A DP switch with indicator |
| 47 | 2 Modular 20A DP switch with indicator |
| 48 | 1 Modular 16A 1 way switch |
| 49 | 1 Modular 16A 1 way switch with indicator |
| 50 | 1 Modular 6A 1 way switch |
| 51 | 1 Modular 6A 1 way switch with indicator |
| 52 | 1 Modular 10A 2 way switch |
| 53 | 2 Modular 10A socket |
| 54 | 2 Modular 20A socket 5 pin |
| 55 | 2 Modular 10A bell push switch |
| 56 | 1 Modular 6A bell push switch |
| 57 | 2 Modular 16A 5 pin socket |
| 58 | 1 Modular 6A 2 pin socket |
| 59 | 2 Modular 5 step fan speed regulator |
| 60 | 1 Modular blank plate |
| 61 | Replacement / fixing of Modular surface box with equivalent as required |
| 62 | 1 Modular surface box |
| 63 | 1 Modular Plate |
| 64 | 2 Modular Surface box |
| 65 | 2 Modular Plate |
| 66 | 3 Modular Surface box |
| 67 | 3 Modular Plate |
| 68 | 4 Modular Surface box |
| 69 | 4 Modular Plate |
| 70 | 6 Modular Surface box |
| 71 | 6 Modular Plate |
| 72 | 8 Modular Surface box |
| 73 | 8 Modular Plate |
| 74 | 12 Modular Surface box |
| 75 | 12 Modular Plate |
| 76 | Replacement / fixing with equivalent or specified of pre-wired fluorescent tube light fitting of the following types complete with all accessories and tube, etc directly on ceiling/wall including S.S screws, nails, nylon plugs connections and with flexible wire, etc testing and commissioning as required. |
| 77 | LED Tubelight set 20w 1800 lumen 4 feet |
| 78 | LED Tubelight set 7w 2 feet |
| 79 | Replacement of PVC Bulk head light fitting with suitable LED bulb all accessories etc directly on wall including S.S screws, nails, nylon plugs and connections with flexible wire as required. |
| 80 | Supply, installation, testing and commissioning of the following type of LED flood including all accessories complete as required |
| 81 | LED flood light 50w |
| 82 | LED flood light 100w |
| 83 | LED flood light 150w |
| 84 | Replacement with the following energy efficient ceiling fans including installation, testing and commissioning without regulator including the wiring down rod standard length with 1.5 sqmm PVC insulated copper wire / flexible twin twisted / round 2 core etc. |
| 85 | Ceiling fan 900 mm sweep BEE 5 star rated |
| 86 | Ceiling fan 900 mm sweep BEE 5 star rated BLDC |
| 87 | Ceiling fan 1200 mm sweep BEE 5 star rated |
| 88 | Ceiling fan 1200 mm sweep BEE 5 star rated BLDC |
| 89 | Ceiling fan 1400 mm BEE 5 star rated |
| 90 | Providing & fixing of fan hooks complete min. 10 mm as required |
| 91 | Supplying, installation, testing and commissioning the following type of exhaust fan including the wiring with 1.5 sqmm PVC insulated copper cable / flexible twin twisted / round 2 core etc as required. |
| 92 | Exhaust fan 150 mm BEE 5 star rated |
| 93 | Exhaust fan 200 mm BEE 5 star rated |
| 94 | Replacement with equivalent or specified insulation, testing and commissioning the following type of wall mounting fan including wiring with 1.5 sqmm PVC insulated copper cable / flexible twin twisted / round 2 core etc as required.Note: Preferable brand are Anchor, Bajaj, Crompton Greaves, Havells, V-guard, Khaitan, Almonard etc. |
| 95 | Wall mounting fan 400 mm OSC type |
| 96 | Replacement of bakelite pendent holder on the existing PVC junction box / TW box / round block / square block including connection |
| 97 | Replacement of PVC round block / square block including screw / nail etc and connections etcUnit |
| 98 | Replacement of Ceiling rose on the existing PVC junction box / round block including connections etc |
| 99 | Replacement / fixing bakelite standing / straight holder on the existing PVC junction box / round block / square including connections |
| 100 | Replacement of following MCB Distribution box 230V / 15V-50Hz with neutral link earth connection and provision for SP / SPN / TPN / ELCB of 6/10/16/20/25/32/40/63/100 Amps per way including drilling hole on the board, connections and earthing the body etc as required. |
| 101 | 4 way single phase |
| 102 | 6 way single phase |
| 103 | 8 way single phase |
| 104 | 10 way single phase |
| 105 | 12 way single phase |
| 106 | Replacement with equivalent of the following 230V / 415V – 50Hz SP / SPN / TPN / ELCB having current 10 / 16 / 20 / 25 / 32 / 40 / 63 / 100 Amps on existing MCB distribution box including hole on the board, connections and earthing the body as required. |
| 107 | MCB SP 6 Amps |
| 108 | MCB SP 10 Amps |
| 109 | MCB SP 16 Amps |
| 110 | MCB SP 20 Amps |
| 111 | MCB SP 25 Amps |
| 112 | MCB SP 32 Amps |
| 113 | MCB SPN 10 Amps |
| 114 | MCB SPN 16 Amps |
| 115 | MCB SPN 20 Amps |
| 116 | MCB SPN 25 Amps |
| 117 | MCB SPN 32 Amps |
| 118 | MSB SPN 40 Amps |
| 119 | MCB TPN 16 Amps |
| 120 | MCB TPN 20 Amps |
| 121 | MCB TPN 25 Amps |
| 122 | MCB TPN 32 Amps |
| 123 | MCB TPN 40 Amps |
| 124 | RCCB SPN 30mA – 16A |
| 125 | RCCB SPN 30mA – 20A |
| 126 | RCCB SPN 30mA – 32A |
| 127 | RCCB SPN 30mA – 40A |
| 128 | RCCB TPN 30/100/300mA – 16A |
| 129 | RCCB TPN 30/100/300mA – 20A |
| 130 | ELCB TPN 30/100/300mA – 25A |
| 131 | ELCB TPN 30/100/300mA – 32A |
| 132 | ELCB TPN 30/100/300mA – 40A |
| 133 | Replacement with MCCB 200A 4 pole |
| 134 | Replacement of following items with equivalent including testing and commissioning |
| 135 | Fan Condenser 2.5 / 2mfd |
| 136 | Fluorescent Tube 36w |
| 137 | Fixing / Replacement of cut out 16/32/63/100 |
| 138 | Supply, erection, testing and commissioning of the following gate / garden lights |
| 139 | Gate light with LED lamp 11 watt |
| 140 | Post top garden light pump with 11 watt & PVC pipe etc as required |
| 141 | Replacement / Re-earthing |
| 142 | Replacement of earthing with G.I pipe 2.5m long 40 mm dia complete as required |
| 143 | Supply & drawing No.14 SWG copper as required |
| 144 | Supply and earthing with copper plate 600x600x6mm including soldering and other accessories, masonry enclosure with cover plate having locking arrangement water pipe including cost of 40 mm G.I complete as required |
| 145 | Replacement of following lamps with equivalent including testing and commissioning |
| 146 | LED Lamp 7w |
| 147 | LED Lamp 9w |
| 148 | LED Lamp 11 watt |
| 149 | Replacement with LED flood light of 100w / 200w complete as required |
| 150 | Replacement with LED street lights of 20 / 25 / 39w complete as required |
| 151 | Providing and fixing of industrial socket female/male of 32/40/63/100A |
| 152 | Supply & fixing of Sintex Meter box with front glass 400x300x190 |
| 153 | Supply & fixing of Sintex Meter box with front glass 270x225x135 |
| 154 | Supply & fixing of Sintex junction box size 250x200x105 |
| 155 | Supply & Fixing of Sintex junction box 155x100x60 |
| 156 | Replacement and drawing of WP service wire 2.5 sqmm complete as required |
| 157 | Shifting of energy meter from inside to outside complete as required |
| 158 | Replacement and fixing of energy meter box door type single phase/three phase |
| 159 | Replacement of Energy meter |
| 160 | Rectification of complaint including replacement of LED flood lights 100/150 watt or any other type of luminaires fitting above 5 meters height as required at the following locations and other places. |
| 161 | Indoor Stadium |
| 162 | Long Tennis Court |
| 163 | Volley ball court |
| 164 | Conference hall |
| 165 | Power house / premises |
| 166 | Panchayath stage |