| 1 | Comprehensive maintenance by OEM or auth service person for 11 month and person will bevisit every month or including emergency visits required during in month contract period as and when required for the diagnosis of trouble, adjustment, minor repair of dust and cooling tower such as nuts bolts, washers and leakage of dusting parts etc or re-setting of controlas well as maintenance of central air conditioning plant chiller unit of capacity 3x150 TR and other connected installed machineries & accessories (screw type compressor 3x150TR(Make-M/s Trane) single stage 3000 rpm 415 volt AC 50 Hz, semi hermetically sealed motor of capacity 235 KW,Hot water generator 180 KW 2 Nos, 60 KW 1 No & pumping sets, condensing pumping sets 3 Nos, FRP cooling tower, mono block pump sets -3 Nos, Air handling units -28 Nos with belt driven motor, FCU 27 Nos,air blower fittings, shaft assembly cooling coilexpansion valve water softening plant control panel LT panel Remote control panel of AHU\"s etc) with and including chemicals required for de scaling of condenser and chillers, compressor and connected motors etccompletelycleaning, removing the dust particles, servicing, as per manufacturer\"s recommendation through out contract period all required for the efficient, smooth & satisfactorily functioning as per manufacturer\"s instruction complete all as specified and directed. |
| 2 | Notes:- (a) The tenderers shall have to submit the copy of MOU with OEM M/s Trane company through its authorizedservice provider as a proof to carry outannual/quarterly/prevantive maintenance etc recommended by OEM immediatly after commencement of work and strictly follow the company maintenance recommendations.The rates quoted shall be deem to include all such maintenance cost.(b) The contractor shall submit the record of periodical /preventive /annual maint service carried out M/s Trane along with recommendation of necessary repairs and maintenance proceure alongwith documentary evidence for claiming payment. The contractor shall produce the \"purchase order\" issued to M/s Trane/auth service provider for Annual Maintenance.(c) Contractors quoted rates shall be deemed to beinclusive of any replacementmiscellaneous minor parts (costing less than Rs 500/ each part) , such as greasing, oiling,wires, toggle switch, lugs, nuts, cable gland, connector, thimbles, gland packing etc when required or as ordered by Engr in Charge for smooth and uninterrupted operation of the complete system except spares such as mentioned here in after in relevant items of this schedule.(d) The item ratesdescaling etc and including cleaning/washing filters at28 AHUs and 27 FCUs every month complete all as directed by Engr in Chargefailing which a penalty@ Rs. 1000/- per month will be charged. |
| 3 | (e)In contract period once Oil sample analysis of chiller compressor oil from Trane Factory for testing of oil parameters as mentioned in Trane chiller servicemannual. Asper the oil analysis report replacment of Oil & Oil Filter for smooth and efficient working of compressor.(f)In case of any major break down the additional manpower if required will be arranged by the contractor to re-start the plant without any additional cost.(g)The rates are included extra labour for repairing and N2 pressure testing including N2 gas required for checking of leakage or repairing of compressor and overhauling.Refrigerant gas will be measured in relevant items and also check LT Panel repair minor damage in panel if any required the rates quoted shall includingas directed by Engr in Charge (h) The rates quoted shall include checking of ducting & grill for leakages and repair the same, loose fitting /tightening of ducting etc to reduce vibration & noise and gland packing of pumps etc. make up water tank /expansion tank ofhot water circuitand chilled water circuit, installed atthe roof of the plant room & various locations of hospital building. |
| 4 | Supplying laying fixing testing and commissioning of insulation 13mm thick of following sizes of chilled water piping inside the building with closed cell elastomeric nitirle rubber of insulation applied by adhesive confirming to standards specification complete all as specified and directed |
| 5 | 25 mm |
| 6 | 32mm |
| 7 | 40 mm |
| 8 | M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes as shown complete including taking down all as specified and directed. |
| 9 | (a) 32 mm |
| 10 | (b) 40 mm |
| 11 | (c) 50 mm |
| 12 | Note :- The rates of following are deemed to be include in above quoted rate. (a) M&L for cleaning the duct surface (to be insulated ) byscrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreignmaterials, taking special care so that all duct joints are sealedagainst any leakage. (b) M&L for applying rubber based adhesive CPRX compound.(c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.complete all as specified and directed by Engr-in-Charge.(e) M&L for removing the scrapping items from the side. |
| 13 | S & F in replacement of cassette type PRE filter Frame made out aluminium anodized, Media-Non woven synthetic supported by HDPE mesh on one side and aluminium expanded mesh on the other sidehaving efficiency 99% down to 5 micron complete of following sizes:- |
| 14 | (a)485x461x25 mm |
| 15 | (b) 485x552x25 mm |
| 16 | (c)465x519x25 mm |
| 17 | (d)465x730x25 mm |
| 18 | (e)501x655x25 mm |
| 19 | (f) 585x439x25 mm |
| 20 | (g) 585x449x25 mm |
| 21 | S & F in replacement Hepa filter of suitable size 1067x250x77 mmmade ofAluminium and one side rubber gasket . AHU rated flow (CMH)=1700.IPD (mm WG) less than 25 and efficiency more than 99.99 down to 0.5 micron complete all as specified and directed.Make : Thermo dyne /Mecmark /Purolator /Air tech /Turolaior /Sepctrum |
| 22 | S & F in replacement Hepa filter of suitable size 200x610x305 mm made of Aluminium and one side ruber gasket.AHU rated flow (CMH)=1700.IPD (mm WG) less than 25 and efficiency more than 99.97 down to 0.5 micron complete all as specified and directed.Make : Thermo dyne /Mecmark /Purolator /Air tech /Turolaior /Sepctrum |
| 23 | S & F in replacement fine filter of suitable size 610x305x305 mm made of aluminium and one side gasket. AHUrated flow (CMH)=1700.IPD (mmWG) less than 25 and efficiency more than 99% down 1 to 5 micron complete all as specified and directed.Make : Thermo dyne /Mecmark /Purolator /Air tech /Turolaior /Sepctrum |
| 24 | All as per item No 7.00above but size 610x610x305mm |
| 25 | M & L for rewinding of electric motor of the following capacity, 3 phase 50 HZ 415 Volt with super enamelled copper winding wire of suitable gauge including insulating material, varnishing, heating,etc and including dismantling, reassembling and refixing after rewinding to its original location including testing and commissioning to its satisfactory results all as specified & directed for following capacity of motor:- |
| 26 | (a)upto 2 HP |
| 27 | (b)3 to 5 HP |
| 28 | (c)7.5 HP |
| 29 | (d)15HP |
| 30 | (e)20/25 HP |
| 31 | M&Lfor changing of AC plant system from cooling to heating mode during winter season and shifting heating to cooling during summer as per direction of Eng-in-charge within seven days by draining out complete water from system washing the line and cooling tower min three times to remove impurities from line and all necessary requirement to smooth function of cooling tower except fins and refilling complete plant with soft water, checking system for leakage & arrest same duly testing and commissioning of the system complete all as directed by Engr in Charge.Note:- a) Plant shall be filled with soft water which will be provided from the water softening plant.(b) Necessary chemical/additives required for the same except NaCl 35% are included in item rate. (c)If time exceeds from 07 days for switching over from cooling to heating and vice -versa, panel recovery charges @ 500/- per day shallbe made from the contractor\"s dues in consonance with Srl No 1 (d) here in before (which over is greater).The GE\"s decision shall be final and binding in this respect. |
| 32 | Dismantling and cleaning of water softening plantcomplete with frontal piping & valvingejection systemand cleaning complete including connections of water inlet outlet etc and reassembling all the dismantled components and testing including commissioning complete to the entire satisfaction of Engineer-in-charge. |
| 33 | Removing of old softener Resin and supply and filling new Softener Resin Indion 220 NAto water softening plant complete all as specified and directed. |
| 34 | M&L for cleaning all the components by removing the side of pipes, tanks etc and painting the with two coats of synthetic enamel paint out side and moisture resistance primer inside complete all as directed. |
| 35 | M&L for charging of refrigerant gas R-134(a) with required pressure including arresting of all leakage and testing on full load,all as specified and directed. |
| 36 | Supply & fixing in replacement V beltof following size.Make : Fenner /Dunlop |
| 37 | (a)A-23 |
| 38 | (b)A-24 |
| 39 | (c)A-26 |
| 40 | (d)A-28 |
| 41 | (e)A-39 |
| 42 | (f)A-49 |
| 43 | Supply & fixing in replacement power contactor 3 pole type MNX 25415 volt, 25 Amps complete all as specified and directed. |
| 44 | Supply & fixing in replacement power contactor 3 pole type MNX 18 with415 volt 18Amps complete all as specified and directed. |
| 45 | Supply & Fixing in replacement power contactor 3 pole type MNX 9 with 415 volt, 9 Amps complete all as specified and directed. |
| 46 | Supply and fixing of magnetic coil suitable for MO 25/MO18 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed. |
| 47 | Supply and fixing of magnetic coil suitable for MNX 9 to MNX 40 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed. |
| 48 | Supply and fixing of magnetic coil suitable for MNX 50 or as per existing make suitable for 230/415 Volts AC supply operation complete all as specified and directed. |
| 49 | Supply & fixing in replacement auxiliarycontactor 3 pole type MNX 9 to 50 with a front add mounting complete all as specified and directed. |
| 50 | Supply & fixing in replacement electronic timer 0-30 sec complete all as specified and directed. |
| 51 | Supply & fix in replacement power indicating LED lamp with holder assembly (R,Y,B)230 Volt AC complete all as specified and as directedMake : L&T /Siemens /Telemechanic |
| 52 | Supply and fixin replacement of LED ammeter 0-30/0-40/0-60 amp rangesquare type 240volt AC 50 hz complete all as specified and directed.Make : L&T /AE /ABB |
| 53 | Supply and fixin replacement of LED Voltmeter 0-500 voltage rangesquare type 240volt AC 50 hz complete all as specified and directed.Make : L&T /AE /ABB |
| 54 | Supply & fix in replacement over load relay range 14-23amp, MN2 typeMake : L&T /Siemens /ABB |
| 55 | All as per item No 27.00but range of 9-15 Amp |
| 56 | All as per item No 27.00 but range of20-33 Amp |
| 57 | All as per item No 27.00 but range 2-10 Amp. |
| 58 | Supply andfixin replacement of Push button NO/NC contact as per existing type complete all as specified and directed. |
| 59 | Supply and fixing in replacement of HRC fuse 80A 120kA-500V as per IEC 60269-2 corrosion proof complete all as specified and directed. |
| 60 | Supply & fixing in replacement Butterfly valve of dia 50mm, PN 1.0 made out cast iron close end body conforming to IS 13095 flanged ends,drilled type with steel spindle including nuts, bolts, washers and jointing materials complete all as specified and directedMake: Emerald/Audico/Castle/L&T |
| 61 | All as per Item No-33 above but 65 mm dia |
| 62 | All as per Item No-33 above but 125 mm dia |
| 63 | All as per Item No-33 above but 150 mm dia |
| 64 | S & F in replacement Brass motorized valve 2 way/3 way19 mm dia(DN20) any dia for chilled water pipe line with and incl actuator motor complete and all other accessories required as per site requirement including testing and commissioning complete all as specified and directed. |
| 65 | All as per item No 37 above but 32 mm dia |
| 66 | All as per item No 37 above but 40 mm dia |
| 67 | All as per item No 37 above but 50 mm dia |
| 68 | Supply andfixin replacement ofNRV/Check valve150mm cast iron body and SS 410,SS 410 Shaft & Nitrile seat.The valves shall be designed for PN 1.0including packing material/gasketnut bolts etc complete all as specified and directed. |
| 69 | All as per item No 41.00but size 125 mm |
| 70 | All as per item No 41.00but size 80 mm |
| 71 | Supply & fixing in replacement Balancingvalve 32/40 mm dia shall be of Gun metal/Cast Iron construction with screwed end angular design hand wheel with locking facility and internal parts of SS 410 and EPDM/nitrle seat with flanged ends. The valve shall be designedfor PN 1.0 , including packing material testing & commissioning complete all as specified and directed. |
| 72 | Supply & fixing in replacementBalancingvalve 50 mm dia shall be of Gun metal/Cast Iron construction with screwed end angular design hand wheel with locking facility and internal parts of SS 410 and EPDM/nitrle seat with flanged ends. The valve shall be designedfor PN 1.0 , including packing material testing & commissioning complete all as specified and directed. |
| 73 | Supply & fixing in replacementBalancingvalve 80 mm diashall be of Cast Iron construction with screwed end angular design hand wheel with locking facility and internal parts of SS 410 and EPDM/nitrle seat with flanged ends. The valve shall be designedfor PN 1.0 , including packing material testing & commissioning complete all as specified and directed. |
| 74 | Supply & fixing in replacement Balancingvalve 125 mm diashall be of Cast Iron construction with screwed end angular design hand wheel with locking facility and internal parts of SS 410 and EPDM/nitrle seat with flanged ends. The valve shall be designedfor PN 1.0 , including packing material testing & commissioning complete.including packing material testing & commissioning complete all as specified and directed. |
| 75 | Supply & fixing in replacement Globe valve 25 mm diashall be of Cast Iron construction with screwed end angular design hand wheel with locking facility and internal parts of SS 410 and EPDM/nitrle seat with flanged ends. The valve shall be designedfor PN 1.0 , including packing material testing & commissioning complete. |
| 76 | All as per item No 48.00but size 32 mm |
| 77 | All as per item No 48.00but size 40 mm |
| 78 | Supply & fixing in replacement industrial typealcohol filled thermometer 0-50 degree as per existing make & size and type complete. |
| 79 | Supply & fix in replacement three phase heating element of capacity 14 to 16 KW for hot water generator as specified and as directed |
| 80 | All as per item No 52.0 here and above but 6 to 7.5 KW |
| 81 | Supply and fixing in replacement of PVC cooling fins size of 150x300x600mm in bluish shedding having thickness 0.2 mm and in hexagonl shape for suitable mihir cooling tower of central type AC plant complete all as specified and directed. |
| 82 | S & F in replacement PVC float valve assembly 20mm dia complete with rod,PVC ball andincluding all complete fitting all as specified and as directed. |
| 83 | S & F in replacement pressure gauge round type of 150mm dia metal cased between pressure range 0-10 Kg/sqcm including siphon assy with gun metal stop valve including knob complete all as specified and as directed. |
| 84 | Supply only cleaned salt not less than 35% Nacl for softening of water as per sample complete all as specified and directed. |
| 85 | S & F in replacement water flow switch WF S6000 150 PSI 100 C 1\" NPT 15 Amp 250 Volt complete all as specified and directed. |
| 86 | Supply inreplacement of U/S air strip heater 3 KW finned type suitable for AC Plants complete all as specified & directed. |
| 87 | Dismantling and taking out the exisiting sensorand S&F new Sensor Temperature sensor overmoulded with programming Requiredfor model no 160E 2B02 01A1 type indoor 150 TRAC Plant as specified & directed. |
| 88 | M&L for taking out unserviceable oil refrigeratation lubricant ISO 68 Polyolester and Supply and filling new oil refrigeratation lubricant ISO 68 Polyolester has been purified, dried and tested to assure compliance with trane specifiecation (US gallon 3.78 Ltr). |
| 89 | M&L for taking out unserviceableFilter compressor oil and S&F newFilter compressor oil for model no 160E 2B02 01A1 type indoor,150 TR Plant at New MH complete all as specified and directed. |
| 90 | M&L for taking out unserviceable Gasket , compressor filter cover and S&F new Gasket , compressor filter cover for 150 TR plant at New MH complete all as specified and directed. |
| 91 | Descaling of complete condensor and evaportar by opening lugs,nuts and bolts etc and filling descaling compound and cleaning of complete inner tubes with brush and replacement of rubber gasket for 80 TR Plant at RIMC complete all as specified and directed. |
| 92 | (A).AIR CONDITIONER WINDOW/SPLIT TYPE 1.5/2.0 TR |
| 93 | Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from window type AC and S&F New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed. |
| 94 | All as per Srlitem No.66 here and abovebut compressorsuitable for window AC ofcapacity2.0 Ton complete all as specified and directed. |
| 95 | Dismantling and taking out the existing old unserviceable compressor hermetically/rotarysealed unit of any make from split type AC and S&F New compressor suitable forSplitAC of capacity 1.5 Ton complete all as specified and directed. |
| 96 | All as per Srlitem No.68 here and above but compressorsuitable for Split AC ofcapacity2.0 Ton complete all as specified and directed. |
| 97 | M&Lfor testing leakage in systemSplit/Window type Air conditioner of any capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the systemcomplete all as specified and directed. |
| 98 | M&L for servicing of Air conditioning window/split type of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and Note :- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed (ii).Spare parts costing more than Rs 100.00 each item. |
| 99 | S&F in replacement Starting capacitor of capacity 80-100 MFD |
| 100 | S&F in replacement Starting capacitor of capacity 100-120 MFD |
| 101 | S&F in replacement Condenser capacity of5-6 MFD |
| 102 | S&Fin replacement Condenser capacity of10 MFD |
| 103 | S&F in replacementCondenser capacity of36 MFD |
| 104 | S&F in replacement Condenser capacity of45 MFD |
| 105 | S&F in replacement Condenser capacity of50 MFD |
| 106 | Supply & fixing reverse cycle valve for heating system in window/split type AC 1.5/2 Ton capacity including charging of refrigerant gas R-32/410 and arresting all leakage and testing on full load, complete all as specified and directed. (Note: Charging of R-32/410 shall be paid under relevant item) |
| 107 | S&F in replacement Swing motor suitable for 1.5 Ton Capacity Window AC |
| 108 | S&F in replacement Swing motor suitable for 2.0 Ton CapacityWindow AC |
| 109 | S&F in replacement Swing motor suitable for 1.5 Ton Capacity Split AC |
| 110 | S&F in replacement Swing motor suitable for 2.0 Ton Capacity Split AC |
| 111 | S&F in replacement Over load relay suitable for 1.5/2.0 Ton WindowAC |
| 112 | S&F in replacement Over load relay suitable for 1.5/2.0 Ton SplitAC |
| 113 | S&F in replacement Electric blower motor suitable for 1.5 Ton Capacity WindowAC |
| 114 | S&F in replacement Electric blower motor suitable for 2.0 Ton Capacity WindowAC |
| 115 | S&F in replacement Electric blower motor suitable for1.5 Ton Split AC (Evaporator/Condenser) |
| 116 | S&F in replacement Electric blower motor suitable for2.0 Ton Split AC (Evaporator/Condenser) |
| 117 | S&F in replacement Blower motor fan blade suitable for 1.5/2.0 Windowtype AC |
| 118 | S&Fin replacement Blower motor fan blade suitable for 1.5/2.0 Split type AC |
| 119 | M&L for Dismantling and taking out unserviceable split AC indoor unit and S& F new split AC indoor unit suitable for existing Split type AC 1.5 TR capacity with copper evaporator coil complete including testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect to the satisfaction complete all as specified and directed . |
| 120 | Rewinding of Condenser motor suitable for 1.5/2.0 Ton capacity Window type AC complete all as specified and directed. |
| 121 | Rewinding of Condenser motor suitable for 2.0Ton capacity Window type AC complete all as specified and directed. |
| 122 | Rewinding of Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC complete all as specified and directed. |
| 123 | Rewinding of Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC complete all as specified and directed. |
| 124 | S&F Air Filter Suitable for1.5/2.0 Ton Capacity Window/Split type Air conditioner complete all as specified and directed. |
| 125 | S&F Capillary tube length as per existing size suitable for 1.5/2 Ton Capacity Air conditioner complete all as specified and directed. |
| 126 | S&F PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC complete all as specified and directed. |
| 127 | S&F PCB Circuit for normal/invertor type AC with remote control suitable for any make and Capacity of 1.5/2.0 split type capacity Air Conditioner complete all as specified and directed. |
| 128 | S&F 16 Amp 3 Pin plug top 240 Volt non flammable and durable materialCapacity1.5/2.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/polycab and as persite requirement complete all as specified and directed. |
| 129 | M&L for Refrigerant gas R-32 for topping up complete all as specified and directed. |
| 130 | M&L for Refrigerant gas R 410(a)/ R 404for topping up complete all as specified and directed. |
| 131 | M&L for Dismantling and taking out unserviceable split AC indoor unit (hot and cold) and S& F new split AC indoor unit (hot and cold) suitable for existing Split type AC 1.5 TR capacity with copper evaporator coil complete including testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect to the satisfaction complete all as specified and directed . |
| 132 | M&L for replacement of damagedInsulation thickness 13 mm of size 1/4\" & 3/8\" copper tubeforAC complete as per existing sitecomplete all as specified and directed. |
| 133 | M&L for replacement of damaged Insulation thickness 13mm of size 1/2\" & 5/8\" copper tube for Split AC complete as per existing sitecomplete all as specified and directed. |
| 134 | M&L in servicing of inverter AC of capacity 1.5/2.0 Ton with pressure cleaning all as directed. |
| 135 | M&L for replacement of Copper Tube of size 1/4\"suitable for any type and any capacity Air conditionercomplete all as specified and directed. |
| 136 | M&L for replacement of Copper Tube of size 3/8\" suitable for any type and any capacity Air conditionercomplete all as specified and directed. |
| 137 | M&L for replacement of Copper Tube of size 5/8\" suitable for any type and any capacity Air conditionercomplete all as specified and directed. |
| 138 | Dismantiling and taking out unserviceable split AC outdoor unit and S&F in replacement split AC outdoor unit 1.5 ton capcity including all testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect all as specified and directed. |
| 139 | Taking out and shifting new locationand refixingboth indoor and outdoor unit ofsplit type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0 Tonin wall with rowl plugs including making holes for inlet /outlet in the wallwith condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed. |
| 140 | S&FHeavy duty bracket for fixing of AC\"s.1.5/2 Ton complete all as specified and directed. |
| 141 | M&L for repairs to walk in cooler 1.5 Ton andrepair/replacement the compressor, filter including gas charging and general service complete all as specified and directed. |
| 142 | Dismantiling and taking out unserviceable split AC outdoor unit (hot and cold) and S&F in replacement split AC outdoor unit 1.5 ton capacity(hot and cold) suitable for exisitng split type AC including all testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect all as specified and directed. |
| 143 | M& L for submain wiring with 2 x 6 sqmm single core PVC insulated unsheathed FRLS flexible copper conductor cable and 1 x 6 Sqmm single core PVC insulated unsheathed (FRLS) flexible copper conductor cable as earth lead in and including concealed PVC conduit of suitable dia and making good the disturbed surface complete all as specified and as directed. (Note : Three runs of 6 Sqmm cable, one run of PVC conduit shall be measured as one unit of one Running Metre.) |
| 144 | S & F Single pole and neutral encolsure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 145 | (B).WATER COOLER |
| 146 | Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F newcompressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I,suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete all as specified and directed. |
| 147 | All as per item No.119 here and abovebut compressorsuitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. |
| 148 | M&L for carry out through check up of the unserviceable watercooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed. |
| 149 | S&F Blower fan motor SP, 230V, 50 Hz suitable for 40/80, 60/120 capacitywater cooleras per existng sample complete all as specified and directed. |
| 150 | S&F Over load Protector suitable for compressor of water cooler 60/120 and 40/80 capacity complete all as specified and directed. |
| 151 | S&F Thermostat switch with knobsuitable for compressor of water cooler 60/120 and 40/80 capacity complete all as specified and directed. |
| 152 | S&F PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia complete all as specified and directed. |
| 153 | S&F Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 60/120 and 40/80 capacity complete all as specified and directed. |
| 154 | M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed. |
| 155 | (C).REFRIGERATOR |
| 156 | M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. |
| 157 | All as per item No.129 here and above but compressorsuitable for refrigerator capacity of 280 to 320 Ltrs complete all as specified and directed. |
| 158 | S&F Freezer door suitable for165 to 200 ltrs capacity Refrigerator complete all as specified and directed. |
| 159 | S&F Freezer door suitable for 280 to 320 Ltrs capacity Refigerator complete all as specified and directed. |
| 160 | S&F Relay current typeand over load protector suitable for compressor complete all as specified and directed. |
| 161 | S&F Thermostat auto defrost type suitable for any make and any capacityRefrigerator single door complete all as specified and directed. |
| 162 | S&F Thermostat auto defrost type suitable for any make and any capacity Refrigerator doubledoor complete all as specified and directed. |
| 163 | S&F suitable timer for any capacity complete all as specified and directed. |
| 164 | S&F Electric blower motor suitable for 300 ltr refrigerater inverter type complete all as specified and directed. |
| 165 | S&F PCB Circuit suitable for 280-320 ltr refrigerater inverter type complete all as specified and directed. |
| 166 | S&F cooling sensor suitable for 280-320 ltr regrigerater inverter type complete all as specified and directed. |
| 167 | S&F Thermostate suitable for 300 ltr regrigerater inverter type complete all as specified and directed. |
| 168 | (D) DEEP FREEZER |
| 169 | M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity upto 350 Ltrs Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. |
| 170 | All as per item No 142 here and abovebut compressorsuitable for refrigerator capacity more than 350 to 600 Ltrs complete all as specified and directed. |
| 171 | M&L carry out through check up the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc completeNote:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed. |
| 172 | S&F Relay current type and over load protector suitable for compressor complete all as specified and directed. |
| 173 | S&F Thermostat auto defrost type suitable for any make and any capacity Deep Freezer complete all as specified and directed. |
| 174 | S&F Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete all as specified and directed. |
| 175 | S&F Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity complete all as specified and directed. |
| 176 | S&F Starting relay with overload suitable for310/320 ltrs capacity Deep freezer complete all as specified and directed. |
| 177 | S&F Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer complete all as specified and directed. |
| 178 | Labour only for charging refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and splittype Air conditioner after duly rectifying leakagesby welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas to be measured and paid separately underrespective items of this schedule. |
| 179 | (E) DESERT COOLER |
| 180 | Dismantling and taking out the existing old unsv fan motor with blade including mounting brackets from Desert coolers and S&F new3 speed fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable forD/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed. |
| 181 | M&L for repair to Desert cooler dismantling the unserviceable partsof Desrt coolers,checking the general servicing complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department. (ii).Spare parts costing more than Rs. 100.00 each items shall be measured and paid separately. |
| 182 | S&F Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed. |
| 183 | S&F plastic body material Desert Cooler of 54 Ltr tank capacity 4 star rating 230V AC in white color all as specified and directed.Model No :- DC 55 DLX new of bajaj and equivalent to Khetan and Polar. |
| 184 | S&F Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size |
| 185 | S&F in replacement Capacitor for 2.5 MFD |
| 186 | S&F in replacement Capacitor for 4MFD |
| 187 | S&F in replacement Capacitor for 6 MFD. |
| 188 | S&F Front panel repair of dimension as per existing size suitable for desert coolerof capacity 4000/5000/6000 Cum per hrs complete all as specified and directed. |
| 189 | S&F PVC Flexible hose pipe size 12 to 15 mm suitable for desert coolerall as specified and directed. |
| 190 | S&F plastic body material Desert Cooler of 60 Ltr tank capacity230V AC in white color all as specified and directed.Model No :- DMH 60 Wave of bajaj and equivalent in Khetan and Polar. |
| 191 | S&F PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample |
| 192 | S&F Selector switch as per existing model and size |
| 193 | S&F Bolt, nut with washers as per sample |
| 194 | S&F PVC Connector i.e (Elbow, Tee,3 way etc) |
| 195 | S&F 15 Amp Switch piano type all as specified and directed. |
| 196 | S&F 15 Amp Plug Top 5 pin all as specified and directed. |
| 197 | Taking down the evaporative type desert coolers of Capacity upto 5000 Cum/hr by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the MES No complete all as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail