| 1 | Excavating in trenches of soft and loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge. |
| 3 | M&L for cement concrete 1:4:8 type D-2using 40 mm graded crushed stone aggregate as infoundations filling and mass concrete etc, complete all as specified and directed. |
| 4 | M&L forreinforcement cement concrete M-25 (Design Mix) using 20 mm graded stone aggregateinfoundation, including rafts, footings, foundation beams; plinth beams, base for column, etc under piles and mass concrete, complete all as specified and directed. |
| 5 | M&L forreinforcement cement concrete M-25 (Design Mix) using 20 mm graded stone aggregatecolumns, pillars, peirs, posts and struts,complete all as specified and directed. |
| 6 | M&L forreinforcement cement concrete M-25 (Design Mix) using 20 mm graded stone aggregateinwall, retaining walls, ballast and like, any thickness, above top of footings including attached pilasters and buttresses etc., complete all as specified and directed. |
| 7 | Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc for rough finished surfaces of concrete etc., complete all as specified and directed. |
| 8 | Use & waste of formwork to sides of pillers, posts, struts, piers, columns and stanchions etc for fair finished surfaces of concrete, complete all as specified and directed. |
| 9 | Use & waste of formwork tofaces of walls, retaining walls abutment and similar works including attached pillasters, buttresses etc vertical or to batter etc for fair finished surfaces of concrete, complete all as specified and dirceted. |
| 10 | M & L for mild steel TMT bars 10mm dia or above, cut to length, bent to shape requried, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip etc., complete all as specified and dirrected. |
| 11 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape requried, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip etc., complete all as specified and directed. |
| 12 | All as per item No 11.00 here in before but5 mm dia and over upto and including 10 mm dia in stirrups spacers and binder etc, complete all as specified and directed. |
| 13 | S&F of 75 mm dia UPVC rain water pipe confirming to latest IS13592 (Type \"A\") single socketed, in any length fixed in RCC wall for weep holes, complete all as specified and directed. |
| 14 | M&L for two coats of cement base paint on newly plastered surface of wall including preparation of surface over and including one coat of alkali resistance primer on plastered surfaces, complete all as specified and directed. |
| 15 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surface finished fair and smooth, complete all as specified and directed. |
| 16 | M&L for two coats of cement base paint on plastered surface of wall after complete removal of existing treatment including one coat of alkali resistance primer, complete all as specified and directed. |
| 17 | S&F of mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivrting, etc and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 18 | S&F of plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment FE-290 Gde E-165, complete all as specified and directed. |
| 19 | S&F of Mild steel screw bolts (machine made) with hexagonal of square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut. Length of bolt exc 15cm and n exc 22.5 cm and diameter of neck 16 to 20mm, complete all as specified and directed. |
| 20 | M & L for applying two coats of synthetic enamel paint on newsteel surfaces of any description over 10 cm width or girth over a coat of red oxide zinc primer including preparation of surfaces, complete all as specified and directed. |
| 21 | Supply and fixing razor wire fencing with 2.6mm dia centre core wire having barbs of length 20mm, width 14mm and thickness 0.5mm razor strip on swan neck angle iron and fixing with clamps on angle iron post including all fittings like fastener clips, steel lig rings etc.as shown in drawing, complete all as specified directed. |
| 22 | Supply and fixing concertina coil 1050 mm dia (in stretched position) hot dip galvanised steel wire coated with CRL anti corrosive paint, making diamond shape with the help of dove tail clip (18 SWF) fixed over razor wire with angle iron. The concertina coil is to be fixed with razor wire at points wherever coil touches the bottom of razor wire with the help of hog rings (14 SWG), complete all as specified and directed.Note- (i) Stretch length of each coil shall be 6 mtr complete all as specified and directed. (ii) Angle iron shall be measured paid separately underrespective item of schedule of works. |
| 23 | Returning filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in loose/soft soil, complete all as specified and directed. |
| 24 | Removing excavated soil to a distance exc 500 mtr but n exc 1.5 Km and depositing where directed at a level n.exc 1.50 mtr above the starting point, complete all as specified and directed. |
| 25 | Demolition of cement cocrete of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 26 | Demolition of reinfoced cement concrete of any description and in any position not other wise specifically provided for, complete all as specified and directed. |
| 27 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 28 | M&L for Cement Concrete Type B1 (1:2:4) (20 mm graded stone aggregate) as in foundation filling and mass cocrete for Post Holes, complete all as specified and directed. |
| 29 | M & L for brick work with Sub class \"B\" old size, straight or curved on plan exc 6m mean radius, built in cement morta 1:6,complete all as specified and directed by Eng-in-Charge |
| 30 | Supply only MS galvanised chain link fencing, any size or shape as per sample approved by GE. |
| 31 | Fixing only chain link fencing including line wires, any mesh, size and type to any typeof standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed. |
| 32 | M & L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square not exc 5 cm long dia of neck 11 to 15 mm, complete all as specified and directed. |
| 33 | M&L for preparation of new or previously untreated surfaces of any description n exc 10 cm in width or girth and applying 2 coat of synthetic emanel paint over a coat of red oxide primer when unconnected with other painting or when painted in a different tint, complete all as specified and directed |
| 34 | Removal of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point, complete all as specified and directed. |
| 35 | S&F for galvanised medium coated as per IS -4826, 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel, complete all as specified and directed |
| 36 | M&L for 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 37 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |