| 1 | (SCHEDULE-A PART-I B/R Works) Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and as directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames)exc 1.50 sqm eachand n exc 4 sqm and removing from site complete all as specified and as directed. |
| 3 | Taking down shutter of any description area exc. 1 Sqm and n.exc. 2 Sqm and removing from site complete all as specified and as directed. |
| 4 | S&F Pressed steel frames of size 125 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. |
| 5 | S&F Solid PVC Door Frames of size 50mm X47mm made out of 5mm grainprinted PVC sheet used instead of Plaincolour PVC sheet & edges will be painted to match with printed sheet& drawing complete all as specified and as directed. |
| 6 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having aPVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings complete all as specified and as directed. |
| 7 | Taking down existing cement Plaster of sunkun floor/wall,roughering and cleaning by brushing wire brushes to remove all dirt, withand including applying a coat ofindustrial bitumen 85/25 penetration@ 1.2kg/Sqm over redering 15mm thick in CM (1:3) using WPC finished rough over a coat of neat cement slurry @ 3.0 kg/sqm complete all as specified and as directed. (IWPC shall be measured and paid seperately) complete all as specified and as directed. |
| 8 | Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | M&L for glazed ceramic coloured tiles of size 450x350x7mmthick as required on site, on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thickbacking coat on fair faces of brick work in CM (1:3) complete all as specified and as directed. |
| 10 | Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness complete all as specified and as directed. |
| 11 | M&L for Non–skidceramic colouredtiles 7-8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colouredcement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etccomplete all as specified and as directed. |
| 13 | M&L forRendering 10mm thick onfair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | M&L for Rendering (10+5)mm thick onother than fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 15 | M&L forRendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including three coat of white wash on ceiling including preparation of surface complete all as specified and as directed. |
| 16 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 17 | M & L for Preparation of new plastered surfaces of ceiling and applying two coat of white washing,complete all as specified and as directed. |
| 18 | M & L for Preparation of oldplastered surfaces of ceiling and applying one coat of white washing, complete all as specified and as directed. |
| 19 | M&Lfor Two coat ofwhite wash on old plastered surface on wallincluding preparation of surface complete all as specified and as directed. |
| 20 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. Note: The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no clain on account of misunderstanding or otherwise shall be admissible on this account. |
| 21 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlarfacings dressed stone work and precast concrete articles complete all as specified and as directed. |
| 22 | M & L for Brick work with sub class “B” bricks straight or curved old size brick on plan exc 6 M mean radius build in CM 1:6 using all as specified using old size bricks complete all as specified and as directed. |
| 23 | S & F Box type Steel ventilator with shutter (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing complete all as specified and as directed. |
| 24 | S&F Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 25 | S&F Box type Steel window side hung double shutters with provision (inside for wire mesh & out side for glass), including guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded and fixed, steel window shall be conforming torelevant IS complete all as shown on drawing No CEUZ/TD/1302/09, Sh 1/3 to 3/3 and directed. complete all as specified and directed. Note:- Wire mesh and sheet glass shall be measured and paid separately |
| 26 | S & F 3mm thick sheet glass, ordinary qaulity,in sqaures n exc 0.5 sqm each panes etc complete all as specified and as directed. |
| 27 | S & F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and as directed. |
| 28 | S&F asin repairVitreous china squatting pan \"Orissa \" pattern size 580x440mm white with integral foot restall as fixed in repairs including ‘P’or \"S\" trapincluding PVC low level cistern of 10 litres capacity including brackets jointing to flush pipe, complete fixed in repair complete all as specified and as directed. |
| 29 | S&F in repair EWC vitrous china colour/white, P or S trap,incliding connection to drain or out going pipe and to flushing pipe with plastic water closetseat white pattern , including PVC low level cistern of 10 litres capacity, flat bottom and coverincluding MS CP hinges complete all as specified and as directed. |
| 30 | S&F for heaith faucet (ABS body) mild steel 15mm dia pipe 1.25mtr long flexible tube wall hook and fiting to the connection complete all as specified and as directed. |
| 31 | S&F 75mm long butt hinges(medium weight) colled rolled mild steel complete all as specified and as directed. |
| 32 | S&F Extruded aluminium alloy handles fabricated type anodised of size 125mm long 12mm dia complete all as specified and as directed. |
| 33 | S&F Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 34 | S&F 250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed. |
| 35 | S&F in repair Shower rose brass chrominium plated 125mm size complete all as specified and as directed. |
| 36 | S&Fin repairs Castcopper alloy long body CP bib tap fancy type screwed down , screwed for iron pipe 15mm dia/ bore of pipe complete all as specified and as directed. |
| 37 | S & F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure,screwed for iron pipe 15 mm bore fancy type complete all as specified and as directed. |
| 38 | S&F Castcopper alloy CP stop cock /angle Valve fancy typescrewed both ends for iron pipe15mm dia/ bore of pipecomplete all as specified and as directed. |
| 39 | S&F Towel rail 600 mm long of fixed with including chromium plated brass screws and wooden/plastic/alumi cleats ( Minimum weight 190gm) complete all as specified and as directed. |
| 40 | S&F Vitreous China half stall urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. |
| 41 | S & F for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)complete all as specified and as directed. |
| 42 | S&F as in repair600x 450 mm bevelled edge mirror of selected qualityglass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 43 | S&F in repair vitreous oval type wash basin agle back, size 600x480 mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed. |
| 44 | S&F in repair wall soap dish, vitrious china white,fixed to plugs with chromium plated brass screwsapproximate size 160x160x90 inrepairs complete all as specified and as directed. |
| 45 | S&F stainless steel 6 pin cloth hanger wall mounted door mounted Bathroom cloth wall hook,Door Hooks rail for hanging keys,lvory complete all as specified and as directed . |
| 46 | S&F Rotational moulded polyethene water storage tank 1000 ltr capacity hoisted (three layer) and fixed in position, including PVC float valve 20 mm bore including dismantling of existing tank complete all as specified and as directed. |
| 47 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc.) complete all as specified and as directed. |
| 48 | Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 25mm complete all as specified and as directed. |
| 49 | Taking down steel tubing and connection including cleaning removal to store bore of pipe 20mm complete all as specified and as directed. |
| 50 | S&F 25mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed. |
| 51 | S&F 20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down complete all as specified and as directed. |
| 52 | Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 110mm complete all as specified and as directed. |
| 53 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specified and as directed. |
| 54 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore complete all as specified and as directed. |
| 55 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floorfor 110mm bore complete all as specified and as directed. |
| 56 | S&FPVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floorfor 75mm bore complete all as specified and as directed. |
| 57 | S&F PVC (SWR) Bendsany radius for 110mm bore complete all as specified and as directed. |
| 58 | S&F PVC (SWR) Bendsany radius for 75mm bore with oval access door complete all as specified and as directed. |
| 59 | S&F PVC (SWR) vent cowl 75mm complete all as specified and as directed. |
| 60 | S&F PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete all as specified and as directed. |
| 61 | S&Ffor PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified and as directed. |
| 62 | M&L for 75mm dia cast iron Nahani Trap, with grating including jointing to waste pipe fixed in concrete type B1(1:2:4) complete all as specified and as directed. |
| 63 | S&F as in repair 110 mm PVC (SWR) WC Connector with lip ring complete all as specified and as directed. |
| 64 | S&F PVC (SWR) Branch pieces single( Single Y) equal or unequal) for 110mm bore with oval access doors complete all as specified and as directed. |
| 65 | S&F PVC (SWR) Branch pieces single ( Single Y) equal or unequalfor 75mm bore with oval access doors complete all as specified and as directed. |
| 66 | PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and as directed. |
| 67 | S&F in repairs gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 68 | S&F in repairs Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof for 100 mm bore complete all as specified and as directed. |
| 69 | M & L for Granite (of any color) work (table rubbed and polished) 20mm thick in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 70 | M&L for 20 mm thick screed bed under granite in CM ( 1:4) complete all as specified and directed. |
| 71 | M & L for PCC 1:2:4 type B-1 (with 20mm graded aggregate) as in benching, coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of roof, chajjas, rails, cills etc complete all as specified and as directed. |
| 72 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and as directed. |
| 73 | S&F Framed work rolled section as in framing compound girder staging for end bars, shouldered and riveted, forged into spikes, framed guard bars, dooriron, ladders walk rails, railings, frame work for tanks, water tank,cooler frameas and the like built up from two or more beam or channel section or angles with plates stiffeners etc and similar workcon- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 74 | M&L for75 mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in roof, manhole cover,sunken portion, subbase, etc complete all as specified and as directed. |
| 75 | S & F for TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending and spirally hoping for columns hooking ends and binding with MS wire annealed n.less then 0.90mm dia complete all as specified and as directed. |
| 76 | Material and labour Roughening surface of old concrete, roofs by picking, sweeping clean and washing down withincluding flashings and junction of parapets, and use to neat cement slurry complete removing debris and rubbish from site complete all as specified and as directed. |
| 77 | M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thicknesstwo layers finished even and smoothes in roof padding all as specified and as directed |
| 78 | M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM1:4 in roof complete all as specified and dircted. |
| 79 | Material and labour APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specifiedlaid over Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces.withapplying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as directed and finished withapplying one coat of aluminium paint as directed by Engineer-in-Charge. |
| 80 | (SCHEDULE-A PART-II E.MWorks) Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets,light fittings etc.and keeping in safe custedy for takingcredit complete all as specified and as directed. |
| 81 | M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and inPVC conduit of any size, fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductordrawing as continuous earth wire connected to main earth and earth dollyforOne light/fan point /bell point controlled by one switchswitches/sockets/regulators complete all as specified & directed. (Note :- cost of modular boxes, Suitable modular switch base, frame & cover is included in quoted rate.) |
| 82 | All as per above item 81 but for One 3 pin socket out let 5Amp controlled by one switch on same board complete all as specified and as directed. |
| 83 | All as per above item 81 but forOne 3 pin socket out let 5 Amp controlled by one switch on independent board complete all as specified and as directed. |
| 84 | All as per item No 81 above here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board complete all as specified and as directed. |
| 85 | All as per item No 81 here in before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4sqmm cable as earth continuity conductor for one for one one MCB plug and socket point (For Geyser point) complete all as specified and as directed. |
| 86 | S & F Modular switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and as directed. |
| 87 | S & F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and as directed. |
| 88 | S & F Modular switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and as directed. |
| 89 | S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and as directed.. |
| 90 | S & F Modular blanking plates 1 module complete all as specified and as directed. |
| 91 | S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed. |
| 92 | Supply and fixing aluminium body LED light fitting 1x 18 W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 93 | Supply and fix Copper wounded exhaust fan, steel body AC single Phase. 230V of size 380m sweep with 4 blades, complete with suitable louvers out side of wall , 1300 to 1400 RPM including grouting of fasteners, nut bolts, making hole on wall ,connection with three core copper conductor cable from ceiling rose complete all as specified and directed. Note :- Contractor shall provide 02 years manufacturers warranty certificate. |
| 94 | S&F sheet metal enclosuredistribution board SPN 08 way230 V, 50 Hz double doorwith neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs complete all as specified and as directed. |
| 95 | S&F MCBSPN 40 A to 63 A 10 KA 240 volts \"C\" seriescomplete all as specified and as directed. |
| 96 | S&F MCB single pole 5 to 32 Amps 10 KA 240 volts \"C\" series complete all as specified and as directed. |
| 97 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece making connections with three core PVC insulated and sheathed flexible copper conductor cable from plug and socketincluding taking down of old unserviceable geyser from site and deposited in MES store yard all as specified and directed.etc. |
| 98 | S&F Single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 25Amps, 10 KA \"C\" Series complete all as specified and as directed. |
| 99 | M&L for sub main wiring with two single core FRLSPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 Sq mm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 sq mmas earth continuity conductorconnected to commen earth and earth dolly complete incl taking out existing UNSV service connections complete all as specified and as directed.NOTE: 03 Runs of FRLS cable of 06 sqmm with PVC conduit combined consititutes one RM. |