| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core (multistranded) cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. D.S.R 1.8.1 |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core (multistranded) cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. D.S.R 1.9 |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1x1.5 sqmm.for Inverter D.S.R 1.17.1 |
| 4 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required D.S.R 1.29. |
| 5 | Supplying and fixing metal box of 150mm X 150mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 2 nos. of 3 pin 5/6 A socket outlet and 2 nos. of 5/6 A piano type switch, connections, painting etc. as required.(TV Point) D.S.R 1.22.4 +1.23.1+1.23.4 |
| 6 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. D.S.R 1.30 |
| 7 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. D.S.R 1.57 |
| 8 | Supplying and fixing of following ways surface/ recess mounting, Horizontel type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required . (Note : Horizontel type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door DSR 2.4.1 |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. D.S.R 2.10.3 |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole D.S.R 2.10.1 |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 1.5sq.mm+1X1.5sq. mm earth wire D.S.R 1.14.1 |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X 2.5sq.mm+1X2.5sq. mm earth wire D.S.R 1.14.2 |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X 4sq.mm+1X4sq. mm earth wire D.S.R 1.14.3 |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X 6sq.mm+1X6sq. mm earth wire D.S.R 1.14.4 |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X 10 sq. mm +1 X 6 sq. mm earth wire D.S.R 1.14.5 |
| 16 | Earthing with G.I. earth Pipe 4.5 Meter Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. D.S.R 5.2 |
| 17 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. D.S.R 5.7 |
| 18 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. D.S.R 1.38 |
| 19 | Brush Less Direct Current (BLDC) Fan withoutRemote. Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.. D.S.R 9.2.3 |
| 20 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N D.S.R 2.1.1 |
| 21 | S/F of fresh air Fan 300mm 1-phase 1400 rpm,230/250 volts,50Hz. RA |
| 22 | Supplying, Installation, Testing & Commissioning of18-22 watt LED surface mounted Batten light (System lumen efficacy ≥105 <120lm/Watt). rating and Fixture shall be confirming to relevant BIS standards. Complete in all respect. DSR 8.9.5 |
| 23 | Supply and Fixing of Bulkhead fitting upto 10 Watt lumen 1000 complete in all respect. CAT AAA SOR 23.11 |
| 24 | Supplying, installation, Testing & Commissioningof 45 Watt ( System Lumen efficiency >=105<=120 lm/watt) Street light LED fixture powder coatedpressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV. confirming to relevant BIS standards. Complete in all respect. DSR 8.12.11 |
| 25 | Dismentaling of old Electrical installation including less cost of old material and repairing of surface. APSR Please Enable Macros to View BoQ information |