| 1 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed. |
| 2 | Taking down cement plaster on brick/stone masonary any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed. |
| 3 | Material and labour for brick work with old size sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 4 | Ditto all as per Ser item No 3.00 above, but except bricks. |
| 5 | Material and labour PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth cources, roof kerbs or mud stops, benching, coping, bed plates, parapets, water throughs and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed. |
| 6 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified. |
| 7 | Material and labour for MS TMT bars 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 8 | Material and labour for brick work with old size sub class \"B\" bricks, straight or curved on plan to any radus in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 9 | Material and labour for 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) finished fair and even complete all as specified and directed. |
| 10 | Material and labour providing 25mm thick(measured solid) precast cement concrete louvres and jallies in PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregates) including all mouldings but excluding frame set in cement mortar (1:4) including taking down old damaged jalliesand removing the debris out of defence land complete all as specified and directed. |
| 11 | M&L for Preparation of old plasteredsurfaces of walls,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint on the walls, pillars, cornices etc complete all as specified and as directed. Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys. |
| 12 | Material and labour preparation of newly plastered or unplastered surface of walls including cornices, pillasters etc. and applying two coats of cement base paint complete all as specified and directed. |
| 13 | Material and labour preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 14 | Material and labour preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 15 | Dismantling of fencing posts/ struts of any description (wood, steel or RCC) embedded in concrete, brick work, masonry etc. including taking out embedded portion and making good to disturbed surface complete all as specified and directed. |
| 16 | Dismantling of chain link fencing with mesh, any type complete all as specified and directed. |
| 17 | Excavation in post holes (or similar holes) each not.exc 0.5 cum in any type of soil, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed. |
| 18 | Material and labour PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling, post holes, mass concrete, similar works complete all as specified and directed. |
| 19 | Material and labour PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as insurface channels, drains and other similar works complete all as specified and directed. |
| 20 | Material and labour mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets, sag rods (for securing wire meshfencingetc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 21 | Supply only MS chain link fencing 4mm dia galvanised steel wire and 50mm x 50mm size mesh fixed to steel fencing post by nut & bolts etc including provision of binding wire complete all as specified & directed |
| 22 | Fixing only chain link fencng including line wire any mesh size and type to any type of standards, rails, straining, bolts etc including provn of binding wire complete all as spcecified and directed. |
| 23 | Supply and fixing mild steel screw bolts diameter of neck 10mm (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of boltn exc 5cm long complete all as specified and directed. |
| 24 | S&Fgalvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. fixed in repair complete all as specified and directed (each line wire to be measured separately). |
| 25 | Restraining resecuring includng making good staples galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed |
| 26 | Providinng and fixing in repair concertina coil fencing with punched tape concertina coil 600mm dia. 10m openable length (total length 90m) having 50 Nos round per 6mtr length, upto 3.00m height of wall with existing iron angle Y/U- shaped placed 2.40m or 3.00 m apart and with 9 horizontal R.B.T reinforced bared wire, stud tied with G.I staples and GI clips to retain horizontal, including necessary bolts or GI barned wire tied to angle iron, all comppete as per direction of EIC with reinforced barned tape (TBT)/sring core (2.5mm thick) wire of high tensile strength of 165 kg/sqmm with tape (0.52mm thick) and weight 43.478 gm/mtr. including removing old concertina coil where as required |
| 27 | Dismantling structural steel work including door, gates etc complete all as directed. |
| 28 | Demolition of reinforced cement concrete in ground floors and paving n. exc. 15cm thickness (reinforcement to cut as required to facilitate demolition) complete all as specified and directed. |
| 29 | Material and labour for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. using steelconforming to Fe-410 Gde-E-250 complete including drilled for fixing of steel sheeting or other covering; doors, door frame chowkhats etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified and directed. |
| 30 | Excavation in trenches in soft /loose soil, not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan andgetting out complete all as specified and directed. |
| 31 | Returning, filling in including leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and directed. |
| 32 | Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 33 | Removingand cleaning of soil, grass from drain of any typeto clear the blockagecomplete all as specified and directed |
| 34 | Material and labour for precast cement concrete type B-11:2:4 (20mm graded aggregate) and set in Cement Mortar (1:4) as in landings, manholes cover slabs, chajjas, shelves and similar articlesincluding necessary form work complete all as specified and directed. |
| 35 | M&L for 18 to 20 mm thick Granite (of any type) work in single piece (table rubbed and polished) in steps, floors, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshadeover and including 20mm thick CM (1:6) bedding layer complete all as specified and as directed. |
| 36 | M&L 16 to 18mm thick Dholpur stone cladding repair in patches gang saw cut with machine cut edges, uniform colour of each stone size not exceeding 0.25 sqm fixed with and including in CM 1:3, making V grooveat top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment |