| 1 | Supply install testing and commissioning of OEM manufacturer, static silent (Sound roof enclosure) Diesel engine driven generating set capable of delivering 62.5 KVA, 415 Volts, 3 phase, 4 wire system, 50 Hz at power factor 0.8 minimum. The DG Set should consist of diesel engine coupled to matching alternator, through flexible coupling and comprising of four stroke vertical cylinder water cooling, directly coupled with AC alternator self excited, self regulated and screen protected dust and vermin proof with static exciation system, fixed on common structural steel frame on anti vibration pad, fuel tank, instrument panel, maintenance free battery with starting arrangement and complete set installed in sound proof acoustic enclosure canopy of suitable size as per CPCB norms, standard control panel with metering controls and standard accessories and fittings, necessary engine conforming to IS 10001/10002 and alternator as per IS-13364 complete all as specified and directed and comprising of the following :- |
| 2 | BOQ Item No 1 Contd/...(a)Engine :- diesel generating sets, powered byengines, are rated at 1500 RPM and conform to relevant IS specifications.The engine shall be capable to stand de-rating factor at Borarupak, Arunachal Pradesh for 62.5 KVA rated out put of alternator. The engines are radiator cooled, four stroke, ISO 8528-5 G2, turbo charged and multi-cylinder and with the following accessories:- -Electrical starter motor 12V/24 Volts DC (As per OEM) -Battery charging alternator -fuel system with governor -Dual spin-on fuel filter -Spin-on full flow lub oil filter -Residential silencer -Dry type air cleaner -Shut-off coil with safeties for LLOP/HWT -Flywheel and flywheel housing (b)Alternator :- suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system, conforming to BS 5000 / IS 4722. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated.The alternator should have the following features: -IP: 23 Enclosure, Insulation class \"H\" -Permissible overload of 10% for one hour in 12 hours of operation as per standards(c) Fuel Tank suitable for 8 hours of operation with level indicator. (d) 12V, DC, SMF batteries as per manufacturer\"s instructions with battery leads. |
| 3 | Supply install testing and commissioning of OEM manufacturer, static silent (Sound roof enclosure) Diesel engine driven generating set capable of delivering 45 KVA, 415 Volts, 3 phase, 4 wire system, 50 Hz at power factor 0.8 minimum. The DG Set should consist of diesel engine coupled to matching alternator, through flexible coupling and comprising of four stroke vertical cylinder water cooling, directly coupled with AC alternator self excited, self regulated and screen protected dust and vermin proof with static exciation system, fixed on common structural steel frame on anti vibration pad, fuel tank, instrument panel, maintenance free battery with starting arrangement and complete set installed in sound proof acoustic enclosure canopy of suitable size as per CPCB norms, standard control panel with metering controls and standard accessories and fittings, necessary engine conforming to IS 10001/10002 and alternator as per IS-13364 complete all as specified and directed and comprising of the following :- |
| 4 | BOQ Item No 3 Contd/...(a)Engine :- diesel generating sets, powered byengines, are rated at 1500 RPM and conform to relevant IS specifications.The engine shall be capable to stand de-rating factor at Likabali Mil Stn for 45 KVA rated out put of alternator. The engines are radiator cooled, four stroke, ISO 8528-5 G2, turbo charged and multi-cylinder and with the following accessories:- -Electrical starter motor 12V/24 Volts DC (As per OEM) -Battery charging alternator -fuel system with governor -Dual spin-on fuel filter -Spin-on full flow lub oil filter -Residential silencer -Dry type air cleaner -Shut-off coil with safeties for LLOP/HWT -Flywheel and flywheel housing (b)Alternator :- suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system, conforming to BS 5000 / IS 4722. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated.The alternator should have the following features: -IP: 23 Enclosure, Insulation class \"H\" -Permissible overload of 10% for one hour in 12 hours of operation as per standards(c) Fuel Tank suitable for 8 hours of operation with level indicator. (d) 12V, DC, SMF batteries as per manufacturer\"s instructions with battery leads. |
| 5 | Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying ofUG cable complete all as specified and directed. |
| 6 | Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in soft/loose soil for laying ofUG cable complete all as specified and directed. |
| 7 | Returning , fillingin incl spreading, leveling , wateringand well ramming in layers not exc 25 cm thick in soils. |
| 8 | Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point. |
| 9 | M&L for sand cushioning using dry and clean tibba sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including consolidation upto 180mm thick complete all as specified and directed.Note :- Punned thickness only will be measured and paid. |
| 10 | Supply and laying well burnt/ fire brick of size 230 x 113 x 75mm locally available best quality, sub-class bricks laid in trenches perpendicular to UG cable as cable protection complete all as specified and as directed. |
| 11 | Supply and laying un-reinforced precast concrete cable cover class LV, Type I, flat, size 250 mm x 150mm x 40mm thick, concrete grade grade M-20 minimum, all as specified and as directed. |
| 12 | Supply and laying of XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 70 Sqmm x 3.5 core complete all as specified and directed . |
| 13 | Supply and laying of XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 25 Sqmm x 4 core complete all as specified and directed . |
| 14 | Supply and laying of 80mm dia GI tubinglight grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified anddirected. |
| 15 | Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCAsteel sheet of3.15 mm thickand 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 600 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed. |
| 16 | BOQ Item No 15 Contd/...INCOMMING:-(i) In open execution on-load Change over switch of capacity 200 Amps, 4 Pole, 415 Volt.- 01 No.(ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No.(iii) LED Indicator lamp in three colour RYB - 01 Set of 3.OUTGOING:- (i) MCCB 4 pole, 100 Amps, 16 kA - 02 No\"s. |
| 17 | M & L for Earthing complete with copper earth plate electrode 600x600x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to machinery/equipment etc and incl copper strip 20×3 mm dia as earthing lead by means of bolts, nuts, check nuts and washers, protected with and incl 50 mm dia light grade GI pipe for protection, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work.PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I incl testing on completion complete all as specified and directed. |
| 18 | M & L for Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to machinery/equipment etc and incl GI strip 32×6 mm dia as earthing lead by means of bolts, nuts, check nuts and washers, protected with and incl 50 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work.PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I incl testing on completion complete all as specified and directed. |
| 19 | S&F on load manual change over switch with sheet steel enclosure of currect rating 100 Amps, 4 pole, 415 Volts, 50 Hz complete all as specified and as directed. |