| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size). |
| 5 | RCC WORKS |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 9 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 11 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 12 | (c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick. |
| 13 | (d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 14 | (g)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 15 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4C/Sand) |
| 16 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i)cement mortar 1:4 (1 cement : 4coarse sand) |
| 17 | (a) Upto 1st floor level |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(a) Local best quality Tolhao wood. |
| 19 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws.(a) Local best quality Tolhao wood.(35mm thick) |
| 20 | Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanaighat coarse sand: 6 stone aggrt. 20mm nominal guage). |
| 21 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair oflever handles with necessary screws etc. complete (best make of approved quality ) |
| 22 | Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete :(a) 250x10 mm |
| 23 | Providing & fixing Brass handles with necessary screws etc. complete.(a) 125mm |
| 24 | Providing and fixing bright finished brass hard drawn hooks and eyes (i) 150mm |
| 25 | Providing & fixing M.S. grills of required pattern to wooden frames vertically andhorizontally with M.S. flats at required spacing & frames basedon Architecturaldrawing i/cpriming,painting etc.Complete as per direction ofEngineer-in-Charge. |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600 x 600 mm |
| 27 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3Coarse Sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 28 | Marble stone flooring in treads of steps and risers using single length upto 2.00 metre with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality. |
| 29 | Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete. |
| 30 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick |
| 31 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick. |
| 32 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and |
| 33 | two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 34 | (a) Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5mm having approx. 15% perforated size and pattern as approved by the Engineer-in-charge and as per manufacter\"s specification,with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60. |
| 35 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes |
| 36 | 12mm cement plaster of mix : 1:4 (1 cement : 4 Kanhaighat coarse sand). |
| 37 | 15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand). |
| 38 | 15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 39 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer |
| 40 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 41 | Finishing walls with textured exterior paint of required shade : (i)New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 42 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats |
| 43 | Applying priming coat :-(a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 44 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 45 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 46 | 2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3c/sand) with a floating coat of neat cement inside & outside as per standard design. |
| 47 | (b) Water Supply & Sanitary Installation |
| 48 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 49 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:4:8(1 cement :4 coarse sand :8graded stone aggrt. 40mm nominal size). |
| 51 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 52 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 53 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 54 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 55 | (b) Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 56 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 t C/Sand) |
| 57 | 15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 58 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 59 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 60 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (i) W.C. pan with ISI marked white solid plastic seat and lid. |
| 61 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and makinggood the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of15 mm C.P.brass pillar taps |
| 62 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore |
| 63 | P/F Brass full way valve with C.I. wheel (screwed end) (i) 25mm dia. |
| 64 | (ii) 32mm dia. |
| 65 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 66 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (a) Rectangular shape 1500x450 mm |
| 67 | Providing and fixing C.P brass shower rose with 15 or 20 mm inlet (B) 150 mm dia |
| 68 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A)Concealed work, including cutting chases and making good the wall etc.(i) 15 mm nominal outer dia Pipes |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 72 | (c ) Ground Sump 5 KL Capacity - 1nos |
| 73 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a) Lift upto 1.5 m, |
| 74 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cem :3 coarse sand:6 graded stone aggrt.40mm n/size). |
| 76 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 77 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 78 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 79 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 80 | 15 mm cement plaster 1:3 (1 cement: 3coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 82 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 83 | Providing IEI for T-V Qtr |
| 84 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in PVC cassing capping with modular type switch, modular plate, suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd. |
| 85 | Group A |
| 86 | Group B |
| 87 | Group C |
| 88 | Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable inPVC cassing capping along with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd. |
| 89 | Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable inPVC cassing capping etc.as reqd. |
| 90 | 2X1.5mm2+1X1.5mm2 earth wire |
| 91 | 2X2.5mm2+1X2.5mm2 earth wire |
| 92 | 2X4mm2+1X4mm2 earth wire |
| 93 | 2X10mm2+1X10mm2 earth wire |
| 94 | Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd. |
| 95 | 5/6 amps switch |
| 96 | 15/16 amps switch |
| 97 | 3 pin 5/6 amps socket outlet |
| 98 | 6 pin 15/16 amps socket outlet |
| 99 | P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd. |
| 100 | S/F brass batten/angle holder i/c connection etc.as reqd. |
| 101 | S/F 12W LEDbulb |
| 102 | SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell\"s) |
| 103 | S/F fancy wall bracket suitable for 1x9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc as reqd. |
| 104 | S/F surface/ pendent mounting 1 x 18 W LED lamp channel luminories complete with all accersories connection etc. as required |
| 105 | S/F fan hook i/c bolt & nuts. |
| 106 | S/F 48\"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient) |
| 107 | S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc. |
| 108 | Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioningetc. as reqd. |
| 109 | S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd. |
| 110 | S/F call bell/buzzer suitable for DC/AC single phase 230V complete as reqd. |
| 111 | S/F bell push modular type complete as reqd. |
| 112 | P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd. |
| 113 | S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way |
| 114 | S/F 5 amp to 32 amp rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole |
| 115 | (a)10 amp MCB \"C\" Curve |
| 116 | (a)20 amp MCB \"C\" Curve |
| 117 | Supplying & fixing (following rating) double pole 240V isolatorin existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp |
| 118 | P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc. |
| 119 | Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate havinglocking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.) |
| 120 | Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd. |
| 121 | P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd. |
| 122 | S/F swaged type steel tubular pole 8 mt.long as per 410-SP-14 conforming to IS-2713 (Pt-II) 1980 with bracket in cement concrete 1:3:6 (1 cem.:3 c/sand : 6 gr. St. 40mm n/size) foundation i/c excavation and refilling etc. as reqd. |
| 123 | S/F L.T. cross arm 50X50X6mm - 2 wires |
| 124 | S/F back clamp for L.T. pole |
| 125 | S/F stay set complete with stay wire & stay insulator etc.as reqd. |
| 126 | Supply and drawing of AB cable of size (3x50+1x35)mm2 |
| 127 | Supplying & installation of dry powder(Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity: 4 kg (ISI marked). |
| 128 | Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked). |
| 129 | (B) SH :- Construction of Type-IV Quarters at Kakching District (Block A) |
| 130 | Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a)Lift upto 1.5 m |
| 131 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 132 | Supplying and filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete |
| 133 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:5:10 (1 cement :5 Local coarse sand :10 graded stone aggrt. 40mm nominal size). |
| 134 | Providing and laying in position specified grade of reinforced cement concrteexcluding the cost of centering, shuttering,finishing and reinforcement- All work upto plinth level (a) 1:1.5:3 (1 cement : 1.5 Local coarse sand : 3 graded stone aggrt. 20mm nominal size). |
| 135 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Localcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 136 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Localcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 137 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars. |
| 138 | (b)Thermo-Mechanically Treated bars. |
| 139 | Centering & shutteringincluding strutting , propping etc and removal of form for :(a) Foundation footings, bases of columns etc. and mass concrete. |
| 140 | (c)Columns, pillars, Piers , abutment , post and struts |
| 141 | (d) Lintel , beams , plinth beams , girder , bressumers and cantilever with water proof ply 12mm thick |
| 142 | (b) Suspended floor , roof , landing, balconies ans access platform with water proof ply 12mm thick |
| 143 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 144 | Brick work with 1st class common burnt clay FPS ( non modular) bricks in foundation and plinth in cement mortar 1: 4 (1 Cem:4 Local coarse sand) |
| 145 | Half brick masonry with 1st class common burnt burnt clay FPS in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement : 4 Local coarse sand) |
| 146 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Localcoarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Localcoarse sand) |
| 147 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately (a) Local best quality Tolhao wood |
| 148 | P/F panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/cISI marked MS butthinges bright finishedof required size with necessary screws excluding panelling which will be paid separately , all complete as per direction of Engineer in charge (b)Local best quality Tolhaowood 35 mm thick shutters |
| 149 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portioninside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (a) Local best quality Tolhao Wood |
| 150 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local Best Quality Tolhao wood |
| 151 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm |
| 152 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (a) 250x10 mm |
| 153 | (b) 100x10 mm |
| 154 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (a) 125mm |
| 155 | (b) 100 mm |
| 156 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as D,F4B,K11B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted,including providing and fixing of hinges, pivots , including priming coat of approved steel primer,but excluding the cost of other ittings,complete all as per approved design. (sectional weight of only steel members shall be measured for payment).(a) Fixing with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x 10cm of 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 157 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 158 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 Local coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600x600 mm |
| 159 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3Coarse Sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 160 | Providing and laying Polished Granite stone flooring in required design and patterns, in linearas well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishingetc. all completeas specified and as directed by the Engineer -in - Charge. (a) Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 161 | Providing and laying Ceramic glazed floor tiles 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 162 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 163 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick |
| 164 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick. |
| 165 | Providing and fixing insulating boardceiling of approved quality with necessary nails etc.complete(framework to be paid separately): Natural colour insulating board (i) 12mm |
| 166 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes |
| 167 | Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete. |
| 168 | 12mm cement plaster of mix1:4 (1 cement : 4 Local coarse sand). |
| 169 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Local coarse sand). |
| 170 | 15 mm cement plaster 1:3 (1 cement: 3 Local coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 171 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 172 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer |
| 173 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats |
| 174 | Finishing walls with textured exterior paint of required shade : (i)New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 175 | Applying priming coat :-(a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 176 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 177 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 178 | Coal tarringtwo coats on new works using 0.15 and 0.12 litrs of coal tar per sqm for 1st coat and 2nd coat respectively. |
| 179 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 180 | 2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 Local c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 Local c/sand) with a floating coat of neat cement inside & outside as per standard design. |
| 181 | Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood. |
| 182 | (b). SEPTIC TANK |
| 183 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 184 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 185 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:4:8(1 cement :4 coarse sand :8graded stone aggrt. 40mm nominal size). |
| 186 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 187 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 188 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 189 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 190 | (b) Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 191 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 t C/Sand) |
| 192 | 15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 193 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 194 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 195 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (i) W.C. pan with ISI marked white solid plastic seat and lid. |
| 196 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and makinggood the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of15 mm C.P.brass pillar taps |
| 197 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore |
| 198 | P/F Brass full way valve with C.I. wheel (screwed end) (i) 25mm dia. |
| 199 | (ii) 32mm dia. |
| 200 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 201 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (a) Rectangular shape 1500x450 mm |
| 202 | Providing and fixing C.P brass shower rose with 15 or 20 mm inlet (B) 150 mm dia |
| 203 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 204 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 205 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A)Concealed work, including cutting chases and making good the wall etc.(i) 15 mm nominal outer dia Pipes |
| 206 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 207 | (c ) Ground Sump 5 KL Capacity - 1nos |
| 208 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a) Lift upto 1.5 m, |
| 209 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 210 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cem :3 coarse sand:6 graded stone aggrt.40mm n/size). |
| 211 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 212 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 213 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 214 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 215 | 15 mm cement plaster 1:3 (1 cement: 3coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 216 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 217 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 218 | ( C )SH :- Construction of Type-IV Quarters at Kakching District (Block B) |
| 219 | Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a)Lift upto 1.5 m |
| 220 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 221 | Supplying and filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete |
| 222 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:5:10 (1 cement :5 Local coarse sand :10 graded stone aggrt. 40mm nominal size). |
| 223 | Providing and laying in position specified grade of reinforced cement concrteexcluding the cost of centering, shuttering,finishing and reinforcement- All work upto plinth level (a) 1:1.5:3 (1 cement : 1.5 Local coarse sand : 3 graded stone aggrt. 20mm nominal size). |
| 224 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Localcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 225 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Localcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 226 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars. |
| 227 | (b)Thermo-Mechanically Treated bars. |
| 228 | Centering & shutteringincluding strutting , propping etc and removal of form for :(a) Foundation footings, bases of columns etc. and mass concrete. |
| 229 | (c)Columns, pillars, Piers , abutment , post and struts |
| 230 | (d) Lintel , beams , plinth beams , girder , bressumers and cantilever with water proof ply 12mm thick |
| 231 | (b) Suspended floor , roof , landing, balconies ans access platform with water proof ply 12mm thick |
| 232 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 233 | Brick work with 1st class common burnt clay FPS ( non modular) bricks in foundation and plinth in cement mortar 1: 4 (1 Cem:4 Local coarse sand) |
| 234 | Half brick masonry with 1st class common burnt burnt clay FPS in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement : 4 Local coarse sand) |
| 235 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Localcoarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Localcoarse sand) |
| 236 | Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately (a) Local best quality Tolhao wood |
| 237 | P/F panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/cISI marked MS butthinges bright finishedof required size with necessary screws excluding panelling which will be paid separately , all complete as per direction of Engineer in charge (b)Local best quality Tolhaowood 35 mm thick shutters |
| 238 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portioninside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (a) Local best quality Tolhao Wood |
| 239 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :(a) Local Best Quality Tolhao wood |
| 240 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm |
| 241 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (a) 250x10 mm |
| 242 | (b) 100x10 mm |
| 243 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (a) 125mm |
| 244 | (b) 100 mm |
| 245 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as D,F4B,K11B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted,including providing and fixing of hinges, pivots , including priming coat of approved steel primer,but excluding the cost of other ittings,complete all as per approved design. (sectional weight of only steel members shall be measured for payment).(a) Fixing with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x 10cm of 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 246 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 247 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 Local coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600x600 mm |
| 248 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3Coarse Sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 249 | Providing and laying Polished Granite stone flooring in required design and patterns, in linearas well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishingetc. all completeas specified and as directed by the Engineer -in - Charge. (a) Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 250 | Providing and laying Ceramic glazed floor tiles 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 251 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 252 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick |
| 253 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick. |
| 254 | Providing and fixing insulating boardceiling of approved quality with necessary nails etc.complete(framework to be paid separately): Natural colour insulating board (i) 12mm |
| 255 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes |
| 256 | Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete. |
| 257 | 12mm cement plaster of mix1:4 (1 cement : 4 Local coarse sand). |
| 258 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Local coarse sand). |
| 259 | 15 mm cement plaster 1:3 (1 cement: 3 Local coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 260 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 261 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer |
| 262 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats |
| 263 | Finishing walls with textured exterior paint of required shade : (i)New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 264 | Applying priming coat :-(a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 265 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 266 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 267 | Coal tarringtwo coats on new works using 0.15 and 0.12 litrs of coal tar per sqm for 1st coat and 2nd coat respectively. |
| 268 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 269 | 2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 Local c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 Local c/sand) with a floating coat of neat cement inside & outside as per standard design. |
| 270 | Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood. |
| 271 | (b). SEPTIC TANK |
| 272 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 273 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 274 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:4:8(1 cement :4 coarse sand :8graded stone aggrt. 40mm nominal size). |
| 275 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 276 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighatcoarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 277 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 278 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 279 | (b) Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 280 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 t C/Sand) |
| 281 | 15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 282 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 283 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 284 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (i) W.C. pan with ISI marked white solid plastic seat and lid. |
| 285 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and makinggood the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of15 mm C.P.brass pillar taps |
| 286 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore |
| 287 | P/F Brass full way valve with C.I. wheel (screwed end) (i) 25mm dia. |
| 288 | (ii) 32mm dia. |
| 289 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 290 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (a) Rectangular shape 1500x450 mm |
| 291 | Providing and fixing C.P brass shower rose with 15 or 20 mm inlet (B) 150 mm dia |
| 292 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 293 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 294 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A)Concealed work, including cutting chases and making good the wall etc.(i) 15 mm nominal outer dia Pipes |
| 295 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 296 | (c ) Ground Sump 5 KL Capacity - 1nos |
| 297 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a) Lift upto 1.5 m, |
| 298 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 299 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cem :3 coarse sand:6 graded stone aggrt.40mm n/size). |
| 300 | (b) 1:2:4 (1 cem :2coarse sand:4 graded stone aggrt.20mm n/size). |
| 301 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 302 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 303 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 304 | 15 mm cement plaster 1:3 (1 cement: 3coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 305 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 306 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 307 | Providing IEI for 2 nos of T-IV Quarter Block A and B |
| 308 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in PVC cassing capping with modular type switch, modular plate, suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd. |
| 309 | (a) Group A |
| 310 | (b) Group B |
| 311 | © Group C |
| 312 | Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable inPVC cassing capping along with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd. |
| 313 | Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable inPVC cassing capping etc.as reqd. |
| 314 | (a) 2X1.5mm2+1X1.5mm2 earth wire |
| 315 | (b) 2X2.5mm2+1X2.5mm2 earth wire |
| 316 | © 2X4mm2+1X4mm2 earth wire |
| 317 | Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd. |
| 318 | (a) 5/6 amps switch |
| 319 | (b) 15/16 amp. switch |
| 320 | © 3 pin 5/6 amps socket outlet |
| 321 | (d) 6 pin 15/16 amps socket outlet |
| 322 | P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd. |
| 323 | S/F brass batten/angle holder i/c connection etc.as reqd. |
| 324 | S/F 12W LEDbulb |
| 325 | SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell\"s) |
| 326 | S/F fancy wall bracket suitable for 1x9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc as reqd. |
| 327 | S/F surface/ pendent mounting 1 x 18 W LED lamp channel luminories complete with all accersories connection etc. as required |
| 328 | S/F fan hook i/c bolt & nuts. |
| 329 | S/F 48\"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient) |
| 330 | S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc. |
| 331 | Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioningetc. as reqd. |
| 332 | S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd. |
| 333 | S/F call bell/buzzer suitable for DC/AC single phase 230V complete as reqd. |
| 334 | S/F bell push modular type complete as reqd. |
| 335 | P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd. |
| 336 | S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way |
| 337 | S/F 5 amp to 32 amp rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole |
| 338 | (a)10 amp MCB \"C\" Curve |
| 339 | (b)20 amp MCB \"C\" Curve |
| 340 | Supplying & fixing (following rating) double pole 240V isolatorin existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp |
| 341 | Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd. |
| 342 | Extra for using salt and charcoal for pipe electrode as reqd. |
| 343 | P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd. |
| 344 | Supply & installation of carbon diaoxide type fire extinguisher (suitable for fires involving materials like oil, electric & delicate machinaries). Capacity : 4.5 kg (ISI marked). |
| 345 | ( D )SH :- Construction of Type-III (G+3) Quarters at Kakching District |
| 346 | (A) GROUND FLOOR |
| 347 | SH : EARTH WORK |
| 348 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 349 | b) Lift above 1.5 m to 3.00 m |
| 350 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 351 | Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete |
| 352 | SH : CONCRETE WORKS |
| 353 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 354 | SH : R.C.C. WORKS |
| 355 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 356 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 357 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 358 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in positionand binding all complete (b) Thermo-Mechanically Treated bars. |
| 359 | FORM WORKS |
| 360 | Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete |
| 361 | (b)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 362 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick |
| 363 | ( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick |
| 364 | (e)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 365 | (f)Stairs, ( excluding landing) except spiral-staircases. |
| 366 | BRICKS WORKS |
| 367 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 368 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 369 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).(a)Local best quality Tolhao wood |
| 370 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows i/c ISI marked MS butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately,, all complete as per direction of Engineer-in-charge. (a) Local best quality Tolhao wood, 35 mm thick shutter |
| 371 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Talhao wood |
| 372 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3coarse sand:: 6 stone aggrt. 20mm nominal guage). |
| 373 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 374 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm |
| 375 | Providing and fixing bright finished brass handles with screws etc.complete :.(a) 125mm |
| 376 | Providing and fixing bright finished brass hard drawn hooks and eyes(a) 150 mm |
| 377 | Providing and fixing glazing in aluminium door, window, ventilator, shutter and partitions etc with EPDM rubber/neoprene gasket etc complete as per the architechtural drawing and direction of engineer in charge. (Cost of aluminium snap beading shall be paid in basic item)(i)With float glass panes of 5.50 mm thickness |
| 378 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4Coarse Sand)including grouting the joints with white cement and matching pigments etc. complete i) Size of Tile 600x600 mm |
| 379 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 380 | Granite 12.5mm thickin risers of steps , skirting , dado walls and pillars laid on 10 mmthick base of cement mortar 1 : 3 ( 1 Cement: 3coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green |
| 381 | Providing and fixing stainless steel (grade 304 )railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered e/c fixing accessories such as nuts, bolts, fasteners etc ) |
| 382 | SH : FINISHING |
| 383 | 12mm cement plaster of mix 1:4 (1 cement : 4 coarse sand). |
| 384 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 385 | 15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall |
| 386 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete |
| 387 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer |
| 388 | Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm. |
| 389 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work. |
| 390 | Applying priming coats:-With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 391 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 392 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, includingfinishing the top smooth |
| 393 | 2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Localsand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Localsand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Localsand) with a floating coat of neat cement inside & outside as per standard design. |
| 394 | (B) FIRST FLOOR |
| 395 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 396 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 397 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in positionand binding all complete (b) Thermo-Mechanically Treated bars. |
| 398 | FORM WORKS |
| 399 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 400 | (b)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 401 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick |
| 402 | ( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick |
| 403 | (e)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 404 | (f)Stairs, ( excluding landing) except spiral-staircases. |
| 405 | BRICKS WORKS |
| 406 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 407 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).(a)Local best quality Tolhao wood |
| 408 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows i/c ISI marked MS butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately,, all complete as per direction of Engineer-in-charge. (a) Local best quality Tolhao wood, 35 mm thick shutter |
| 409 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Tolhao wood |
| 410 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3coarse sand:: 6 stone aggrt. 20mm nominal guage). |
| 411 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 412 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm |
| 413 | Providing and fixing bright finished brass handles with screws etc.complete :.(a) 125mm |
| 414 | Providing and fixing bright finished brass hard drawn hooks and eyes(a) 150 mm |
| 415 | Providing and fixing aluminium work for door window s ventilator and partition with extruded built up standardtubular section / appropriate Z section and other section of approved make conforming to IS : 733 and IS :1285 fixed with rawl plugs and screws or with fixing clip or with expansion hold fasteners including necessary filling up of gap at junction at top bottom and sides with required EPDM / neoprene gasket etc . aluminium section shall be smooth rust free straight mitred and jointed mechanically whereever required including clest angle /. Aluminium snap beading for glazing / panneling c CP brass / stainless steel screws all comple as per architectural drawings and the direction of engineer in charge ( glazing and panelling to be paid separately |
| 416 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4Coarse Sand)including grouting the joints with white cement and matching pigments etc. complete i) Size of Tile 600x600 mm |
| 417 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 418 | Granite 12.5mm thickin risers of steps , skirting , dado walls and pillars laid on 10 mmthick base of cement mortar 1 : 3 ( 1 Cement: 3coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green |
| 419 | SH : FINISHING |
| 420 | 12mm cement plaster of mix 1:4 (1 cement : 4 coarse sand). |
| 421 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 422 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete |
| 423 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer |
| 424 | Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm. |
| 425 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work. |
| 426 | Applying priming coats:-With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 427 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 428 | (C) SECOND FLOOR |
| 429 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 430 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 431 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in positionand binding all complete (b) Thermo-Mechanically Treated bars. |
| 432 | FORM WORKS |
| 433 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 434 | (b)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 435 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick |
| 436 | ( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick |
| 437 | (e)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 438 | (f)Stairs, ( excluding landing) except spiral-staircases. |
| 439 | BRICKS WORKS |
| 440 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 441 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).(a)Local best quality Tolhao wood |
| 442 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows i/c ISI marked MS butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately,, all complete as per direction of Engineer-in-charge. (a) Local best quality Tolhao wood, 35 mm thick shutter |
| 443 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Tolhao wood |
| 444 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3coarse sand:: 6 stone aggrt. 20mm nominal guage). |
| 445 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 446 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm |
| 447 | Providing and fixing bright finished brass handles with screws etc.complete :.(a) 125mm |
| 448 | Providing and fixing bright finished brass hard drawn hooks and eyes(a) 150 mm |
| 449 | Providing and fixing aluminium work for door window s ventilator and partition with extruded built up standardtubular section / appropriate Z section and other section of approved make conforming to IS : 733 and IS :1285 fixed with rawl plugs and screws or with fixing clip or with expansion hold fasteners including necessary filling up of gap at junction at top bottom and sides with required EPDM / neoprene gasket etc . aluminium section shall be smooth rust free straight mitred and jointed mechanically whereever required including clest angle /. Aluminium snap beading for glazing / panneling c CP brass / stainless steel screws all comple as per architectural drawings and the direction of engineer in charge ( glazing and panelling to be paid separately |
| 450 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4Coarse Sand)including grouting the joints with white cement and matching pigments etc. complete i) Size of Tile 600x600 mm |
| 451 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 452 | Granite 12.5mm thickin risers of steps , skirting , dado walls and pillars laid on 10 mmthick base of cement mortar 1 : 3 ( 1 Cement: 3coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green |
| 453 | SH : FINISHING |
| 454 | 12mm cement plaster of mix 1:4 (1 cement : 4 coarse sand). |
| 455 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 456 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete |
| 457 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer |
| 458 | Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm. |
| 459 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work. |
| 460 | Applying priming coats:-With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 461 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 462 | (D) THIRDFLOOR |
| 463 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 464 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 465 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in positionand binding all complete (b) Thermo-Mechanically Treated bars. |
| 466 | FORM WORKS |
| 467 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 468 | (b)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 469 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick |
| 470 | ( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick |
| 471 | (e)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 472 | (f)Stairs, ( excluding landing) except spiral-staircases. |
| 473 | BRICKS WORKS |
| 474 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 475 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).(a)Local best quality Tolhao wood |
| 476 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows i/c ISI marked MS butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately,, all complete as per direction of Engineer-in-charge. (a) Local best quality Tolhao wood, 35 mm thick shutter |
| 477 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality Tolhao wood |
| 478 | Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3coarse sand:: 6 stone aggrt. 20mm nominal guage). |
| 479 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 480 | Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm |
| 481 | Providing and fixing bright finished brass handles with screws etc.complete :.(a) 125mm |
| 482 | Providing and fixing bright finished brass hard drawn hooks and eyes(a) 150 mm |
| 483 | Providing and fixing aluminium work for door window s ventilator and partition with extruded built up standardtubular section / appropriate Z section and other section of approved make conforming to IS : 733 and IS :1285 fixed with rawl plugs and screws or with fixing clip or with expansion hold fasteners including necessary filling up of gap at junction at top bottom and sides with required EPDM / neoprene gasket etc . aluminium section shall be smooth rust free straight mitred and jointed mechanically whereever required including clest angle /. Aluminium snap beading for glazing / panneling c CP brass / stainless steel screws all comple as per architectural drawings and the direction of engineer in charge ( glazing and panelling to be paid separately |
| 484 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4Coarse Sand)including grouting the joints with white cement and matching pigments etc. complete i) Size of Tile 600x600 mm |
| 485 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3coarse sand), jointing, grouting the joint with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm |
| 486 | Granite 12.5mm thickin risers of steps , skirting , dado walls and pillars laid on 10 mmthick base of cement mortar 1 : 3 ( 1 Cement: 3coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green |
| 487 | SH : FINISHING |
| 488 | 12mm cement plaster of mix 1:4 (1 cement : 4 coarse sand). |
| 489 | 15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand). |
| 490 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete |
| 491 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer |
| 492 | Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm. |
| 493 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work. |
| 494 | Applying priming coats:-With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 495 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 496 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 80mm dia. nominal outer dia Pipes |
| 497 | (E) Water Supply & Sanitary Installation |
| 498 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. |
| 499 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 500 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)1:3:6 (1 cem :3Coarse Sand:6 graded stone aggrt.40mm n/size). |
| 501 | (b) 1:2:4 (1 cem :2 LocalLocal coarse sand:4 graded stone aggrt.20mm n/size). |
| 502 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Local coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 503 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 504 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick |
| 505 | (b) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 506 | (c) Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 507 | Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 LocalC/Sand) |
| 508 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth : (i)cement mortar 1:4 (1 cement : 4Local Local coarse sand) |
| 509 | 15 mm cement plaster 1:3 (1 cement: 3 Local coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 510 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 511 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 512 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (i) W.C. pan with ISI marked white solid plastic seat and lid. |
| 513 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make,including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 514 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore |
| 515 | P/F Brass full way valve with C.I. wheel (screwed end) (i) 25mm dia. |
| 516 | (ii) 32mm dia. |
| 517 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 518 | Providing and fixing C.P brass shower rose with 15 or 20 mm inlet (B) 150 mm dia |
| 519 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 520 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 521 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Internal Concealed work, including cutting chases and making good the wall etc.(i) 15 mm nominal outer dia Pipes |
| 522 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 80mm dia. nominal outer dia Pipes |
| 523 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 50mm dia. nominal outer dia Pipes |
| 524 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 525 | (F ) Ground Sump 20 KL Capacity - 1nos |
| 526 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a) Lift upto 1.5 m, |
| 527 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 528 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a)C.C. 1:3:6 (1 cem :3 Local coarse sand:6 graded stone aggrt.40mm n/size). |
| 529 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Local coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 530 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Local coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 531 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Local coarse sand:3 graded stone aggregate 20 mm nominal size.) |
| 532 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a )Thermo-Mechanically Treated bars |
| 533 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. |
| 534 | (b ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick. |
| 535 | (d) Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc. |
| 536 | (e)Edges of slab and breaks in floors and walls (i) Under 20cm wide |
| 537 | 15 mm cement plaster 1:3 (1 cement: 3 Local coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall. |
| 538 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(i) 32mm dia. nominal outer dia Pipes |
| 539 | P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg) |
| 540 | Providing IEI T-III (G+3) |
| 541 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular typeswitch, modular platesuitable size G.I. and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd. |
| 542 | Group A |
| 543 | Group B |
| 544 | Group C |
| 545 | Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd. |
| 546 | Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd. |
| 547 | 2X1.5mm2+1X1.5mm2 earth wire |
| 548 | 2X2.5mm2+1X2.5mm2 earth wire |
| 549 | 2X4mm2+1X4mm2 earth wire |
| 550 | 2X10mm2+2X10mm2 earth wire |
| 551 | 4X16mm2+2X16mm2 earth wire |
| 552 | Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. |
| 553 | 5/6 amps switch |
| 554 | 15/16 amps switch |
| 555 | 3 pin 5/6 amps socket outlet |
| 556 | 6 pin 15/16 amps socket outlet |
| 557 | Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd. |
| 558 | (a) 4 Pair |
| 559 | S/F I.O Outlet Box for RJ 45 |
| 560 | S/F surface/pendent mounting 1x18 w LED lamp channel luminaries complete with all accessories and connection etc as reqd. |
| 561 | S/F fancy wall bracket suitable for 1X15W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd. |
| 562 | SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W015 complete with connection etc as reqd.(Havell\"s) |
| 563 | SITC LED street light 60W 757K made of pressure dia housing with toughned glass and individual high power LED with secondry optics IP66 pritection & impact resistance of (Havell\"s) ENDURAPEARLPLUSL60W complete with all accessories i/c connection etc as reqd. |
| 564 | SITC 50W LED 500K energy saving IP 65 Flood light luminaries with high power LED as light source Havell\"s JETACOMPAECTOFL50W LED 757LTG complete with connection as reqd. |
| 565 | S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd. |
| 566 | S/F bell push modular type complete as reqd. |
| 567 | Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioningetc.as reqd. |
| 568 | S/F 12\"(305mm) dia light duty exhaust fan complete with all accessories |
| 569 | S/F fan hook i/c bolt & nuts. |
| 570 | S/F 48\" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell\"s Pacer) white/Brown/Ivory |
| 571 | S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. |
| 572 | S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd. |
| 573 | S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK. |
| 574 | Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :- |
| 575 | 1. 200 amp. TPN on load changeover switch -1 No. |
| 576 | 2. 200 amp. TPN bus bar chamber- 1 No. |
| 577 | 3. 125 amp. TPN thermal adjustable MCCB - 4Nos. |
| 578 | 4. Prewired module Ammeter, voltmeter with selector switch and indicator lamp (Digital) |
| 579 | S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd. |
| 580 | S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc. |
| 581 | S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way |
| 582 | Supplying & fixing (following rating) double pole 240V isolatorin existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp |
| 583 | S/F 5 amp to 32 amp rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole |
| 584 | (a) 10 amp. |
| 585 | (b) 20 amp. |
| 586 | Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate havinglocking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.) |
| 587 | Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd. |
| 588 | P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd. |
| 589 | Supply & installation of carbon diaoxide type fire extinguisher (suitable for fires involving materials like oil, electric & delicate machinaries). Capacity : 4.5 kg (ISI marked). |
| 590 | Supply & installation of Dry Powder (Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity : 4 kg (ISI marked). |
| 591 | S/F swaged type steel tubular pole 8 mt. long as per 410 SP 14 conforming to IS 2713 (Pt.II) 1980 with bracket in cement concrete 1:3:6 (1:cemeny :3 c/sand :6 gr. St.40 mm n/size) foundation i/c excavation and refilling et. As reqd. |
| 592 | Supply and drawing of AB cable of size (3x50+1x35)mm2. |
| 593 | Cross arm 50X50X6 mm2 wire. |
| 594 | Back clamp for cross arm 50X50X6 mm. |
| 595 | S/F stay set complete with stay wire &stayu insulator etc. as reqd. |
| 596 | 50mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd. |