Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Total BoQ2 Supply price |
| 2 | Total BoQ3 Erection price of Supply |
| 3 | Total BoQ4 SGR Building price |
| 4 | New Substation (SCADA Enabled) |
| 5 | New Substation 2x12.5 MVA Indoor type GIS |
| 6 | Substation |
| 7 | 33 KV MATERIAL |
| 8 | 12.5 MVA, 33/11 KV Power T/F With on-load tap changer including all fitting & accessories etc.(As per UPCL specifications) including loading and unloading. |
| 9 | Concreting of power X\"mer foundation including rail 90 Lbs(482kg),ms angle 50x50x6 mm( 74 kg), MS bar 12 mm dia(116 kg),Excavation of earth in mixed soil(5.776 cmt.),CC 1:4:8(4.344 cmt),Brick work in 1:4(1.147 cmt),RCC 1:1.5:3(2.7 cmt),Plaster in 1:4 (12 sqm). Minimum Height from ground level should be 3 feet. |
| 10 | 33/0.4 KV 25 KVA Station Transformer as per UPCL specifications. (as per Annex-A9) |
| 11 | 33/0.433 KV, 25 KVA Station Transformer |
| 12 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 13 | MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 14 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 15 | MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 16 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 17 | 33 KV Line isolator Vertical type |
| 18 | 33 KV Fuse set |
| 19 | MS Channel 100x50x6mm 2 no. 2.8 mtr. Long with Clamp,Nuts & Bolts for AB Switch all galvanized as per SBD specs for SP-55 Pole. |
| 20 | MS Channel 100x50x6mm 2.8 mtr. Long with Clamp, Nuts & Bolts for DO fuse set all galvanized as per SBD specs for SP-55 Pole . |
| 21 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 22 | 33 KV lightening arrestor |
| 23 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 24 | 33 kV Danger board with clamp Bolts & Nuts |
| 25 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 26 | Insulators for holding earthing strip of lightening arrestor & transformer neutral |
| 27 | G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator |
| 28 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 29 | LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 25 kVA T/F. |
| 30 | Three phase LT-CT operated Smart Meter (with Supply & Erection Charge) for Station/ Distribution Transformer with metering Cubical, CTs etc (Three Phase, Four Wire, Energy Meter for 3-Phase 25 kVA Distribution Transformer) |
| 31 | LTDB & DTR metering channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs For SP-55 |
| 32 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 33 | Rod type earthing complete for pole,LT Panel & metering Cubical with GI wire 6 SWG Annexure C37 |
| 34 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 35 | 8 SWG GI wire |
| 36 | Compound filled earthing/Chemical Earthing(with G.I. Strip 35x6mm for Neutral Earthing of Transformer Annexure C 37 A |
| 37 | Compound filled earthing/Chemical Earthing |
| 38 | G.I. Strip 35x6mm |
| 39 | Compound filled earthing/Chemical Earthing of Transformer Body(with G.I. Strip 35x6mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B |
| 40 | Compound filled earthing/Chemical Earthing |
| 41 | 8 SWG GI wire |
| 42 | G.I. Strip 35x6mm |
| 43 | Compound filled earthing/Chemical Earthingof Lightning Arrestor with G.I. Strip 35x6mm Annexure C 37 C |
| 44 | Compound filled earthing/Chemical Earthing |
| 45 | G.I. Strip 35x6mm |
| 46 | Alluminium paint (Double Coat) |
| 47 | Red Oxide paints |
| 48 | Grouting with Cement Concreating ratio with 1:3:6 |
| 49 | 33kV Single Busbar Gas Insulated Switchgear: |
| 50 | Supply & Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 station transformer, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required.SCADA compatible/operated as per UPCL specifications. |
| 51 | Incoming 33 KV Double Pole structure of SP-55 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A11) |
| 52 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 53 | 33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, bolts & nuts all galvanized (for DoublePole) |
| 54 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 55 | 33 KV Line isolator Vertical type |
| 56 | 33 KV Fuse set |
| 57 | MS Channel 100x50x6mm 3.2 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for 33 KV Line isolator Vertical type & Fuse set. |
| 58 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 59 | 33 kV Base channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized for Cable GI pipe support |
| 60 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 61 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 62 | 33 KV lightening arrestor |
| 63 | 33 kV Polymer Pin Insulator complete |
| 64 | GI Fish Plate 50x8mm for 33 kv DP |
| 65 | Disc fitting forPanther conductor 90 KN B&S type |
| 66 | 33 kV Composite Polymer Disc Insulator B & S type |
| 67 | 33 kV Danger board with clamp Bolts & Nuts |
| 68 | Wedge connector for Panther |
| 69 | Aluminum Binding wire & tape |
| 70 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 71 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 72 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 73 | 8 SWG GI wire |
| 74 | Alluminium paint (Double Coat) |
| 75 | Red Oxide paints |
| 76 | Grouting with Cement Concreating ratio with 1:3:6 |
| 77 | Stay complete (As per Annex-C-18) |
| 78 | 33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD |
| 79 | Stay Wire 7/8 SWG |
| 80 | 33kv Stay Insulator |
| 81 | Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized |
| 82 | Grouting with Cement Concreating ratio with 1:3:6 |
| 83 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 84 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 85 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 86 | 33 KV Cable jointing kit indoor type suitable for 1Cx630 sq. mm. TR-XLPE cable |
| 87 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 88 | Cable jointing kit indoor type suitable for 3Cx50 sq. mm. TR-XLPE cable 33 KV |
| 89 | 33 kv LA sub station class -II |
| 90 | 11KV MATERIAL |
| 91 | Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required. PT required for each of the bus section. SCADA operated. |
| 92 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 93 | 11 KV TR-XLPE Cable joining kit for 1Cx630 Sq. mm. (Outdoor) |
| 94 | 11 KV TR-XLPE Cable joining kit for 1Cx630 sq. mm. (Indoor) |
| 95 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 96 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm. (Indoor ) |
| 97 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm (Outdoor) |
| 98 | LT MATERIALS |
| 99 | LT Power Cable 3.5Cx70 sq. mm. from station T/F to AC/DB along with suitable lugs and its laying double circuit. |
| 100 | LT Control Cable |
| 101 | 2x2.5 Sq.mm |
| 102 | 4x2.5 Sq.mm |
| 103 | 10x2.5 Sq.mm |
| 104 | LT PVC Cable 2Cx6 sq. mm |
| 105 | LT PVC Cable 4Cx10 sq. mm |
| 106 | DC INSTRUMENTS |
| 107 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 108 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 109 | D.C. Distribution Board of prescribed specification. |
| 110 | AC INSTURMENTS |
| 111 | AC Power distribution board of prescribed specification & lighting system consisting of |
| 112 | AC Power Distribution Board |
| 113 | EARTH MAT/CIVIL WORK |
| 114 | Earth Mat |
| 115 | MS round 32 mm dia 6.21 Kg/mtr for laying earth mat/ 32 No electrodes |
| 116 | Cross Joints welding |
| 117 | T-joints. |
| 118 | lap Joint |
| 119 | G.I. Strip for earthing |
| 120 | a) 75mmx8mm |
| 121 | b) 50mm x 5 mm |
| 122 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm & GI wire 8 SWG with Bolts Clamp, & Nuts All Galvanised.(For Fencing, ACDB & DCDB) Annexure C37 |
| 123 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 124 | 8 SWG GI wire |
| 125 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr or 1 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode in ground so that the top of electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. 33 KV LA, 11 KV LA, 33 KV panels, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 126 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 Annesure N-8 A |
| 127 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 128 | For Power transformer neutrul earthing |
| 129 | For Power transformer body earthing |
| 130 | For Power transformer LA earthing |
| 131 | 11 KV & 33 KV VCB pannel earthing both end |
| 132 | G.I. Strip 35x6mm |
| 133 | MISCELANEOUS |
| 134 | MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for Terminal Gantry Bay, bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt All Galvanised. |
| 135 | Wire mesh fencing with gate, stay support, toe wall, duly painted on both site. |
| 136 | ACSR Panther conductor |
| 137 | Fire fighting accessories including |
| 138 | i) 4 sand bucket with angle iron chuggi type stand. |
| 139 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 140 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 141 | 33KV LINE MISCELLANEOUS MATERIALS |
| 142 | Wedge connector for Panther to Panther |
| 143 | Wedge connector for Panther to Dog |
| 144 | Connectors suitable for Panther. |
| 145 | i) For LA suitable for Panther |
| 146 | ii) For Isolators suitable for Panther |
| 147 | v) For Transformers suitable for Panther. |
| 148 | vii)Reinforcement steel M.S. Bar 12mm |
| 149 | viii) Perforated tray for control cable |
| 150 | 11KV LINE MISCELLANIOUS MATERIALS |
| 151 | Outgoing 11kV Double Pole structure of SP-23 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A10) |
| 152 | Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 153 | 11 kV top channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs( for Double pole) |
| 154 | PP of suitable size for Top portion of STP-410, SP-23 Pole |
| 155 | Lightening Arrestors Polymer (9kV, 5kA) |
| 156 | 11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch |
| 157 | 11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators,fuse barrel etc. |
| 158 | 11 kV channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs(for SP-23 pole)for AB Switch and DO Fuse |
| 159 | PP of suitable size for Middle portion of STP-410, SP-23 Pole |
| 160 | 11 kV Base channel 100x50x6mm 2.2 mtr. Long with clamps,nuts & bolt all galvanized for Cable GI Pipe Support |
| 161 | PP of suitable size for Bottom portion of STP-410, SP-23 Pole |
| 162 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 163 | 11 kV Polymer Pin Insulator complete |
| 164 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 165 | Disc fitting for Dog 70 KN B&S type |
| 166 | 11 kV Danger Board with Clamp with N&B |
| 167 | Wedge connector for DOG |
| 168 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-23 Pole) |
| 169 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 170 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 171 | 8 SWG GI wire |
| 172 | Alluminium paint (Double Coat) |
| 173 | Red Oxide paints |
| 174 | Grouting with Cement Concreating ratio with 1:3:6 |
| 175 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 176 | Disc fitting forPanther conductor 90 KN B&S type |
| 177 | Disc fitting for Dog 70 KN B&S type |
| 178 | Cost of Civil work (including foundation, walls, floor, electrical substation building, outdoor yard Gravelling etc. as per enclosed UPCL drawing) |
| 179 | Items for substation office of reputed make |
| 180 | v) Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room. |
| 181 | vi) Shock treatment charts |
| 182 | vii) Danger Board, |
| 183 | viii) Single Line Diagram Board |
| 184 | ix) First Aid Box |
| 185 | x) Sub-station Name Board |
| 186 | xi) Shut down / Break down board (Bi-lingual Hindi & English) |
| 187 | xii) Breakdown Board |
| 188 | xiii) Max. Min. load Board |
| 189 | xiv) Instruction Board |
| 190 | xvi) HT Hand Gloves |
| 191 | Sign Board 1 No. 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3\"x3\",6mm) and height of board 6 feet from ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)to indicate Name of scheme. |
| 192 | New Substation 2x10 MVA Indoor type GIS |
| 193 | Substation |
| 194 | 33 KV MATERIAL |
| 195 | 10 MVA, 33/11 KV Power T/F With on-load tap changer including all fitting & accessories etc.(As per UPCL specifications) including loading and unloading. |
| 196 | Concreting of power X\"mer foundation including rail 90 Lbs(482kg),ms angle 50x50x6 mm( 74 kg), MS bar 12 mm dia(116 kg),Excavation of earth in mixed soil(5.776 cmt.),CC 1:4:8(4.344 cmt),Brick work in 1:4(1.147 cmt),RCC 1:1.5:3(2.7 cmt),Plaster in 1:4 (12 sqm). Minimum Height from ground level should be 3 feet. |
| 197 | 33/0.4 KV 25 KVA Station Transformer as per UPCL specifications. (as per Annex-A9) |
| 198 | 33/0.433 KV, 25 KVA Station Transformer |
| 199 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 200 | MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 201 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 202 | MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 203 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 204 | 33 KV Line isolator Vertical type |
| 205 | 33 KV Fuse set |
| 206 | MS Channel 100x50x6mm 2 no. 2.8 mtr. Long with Clamp,Nuts & Bolts for AB Switch all galvanized as per SBD specs for SP-55 Pole. |
| 207 | MS Channel 100x50x6mm 2.8 mtr. Long with Clamp, Nuts & Bolts for DO fuse set all galvanized as per SBD specs for SP-55 Pole . |
| 208 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 209 | 33 KV lightening arrestor |
| 210 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 211 | 33 kV Danger board with clamp Bolts & Nuts |
| 212 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 213 | Insulators for holding earthing strip of lightening arrestor & transformer neutral |
| 214 | G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator |
| 215 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 216 | LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 25 kVA T/F. |
| 217 | Three phase LT-CT operated Smart Meter (with Supply & Erection Charge) for Station/ Distribution Transformer with metering Cubical, CTs etc (Three Phase, Four Wire, Energy Meter for 3-Phase 25 kVA Distribution Transformer) |
| 218 | LTDB & DTR metering channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs For SP-55 |
| 219 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 220 | Rod type earthing complete for pole,LT Panel & metering Cubical with GI wire 6 SWG Annexure C37 |
| 221 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 222 | 8 SWG GI wire |
| 223 | Compound filled earthing/Chemical Earthing(with G.I. Strip 35x6mm for Neutral Earthing of Transformer Annexure C 37 A |
| 224 | Compound filled earthing/Chemical Earthing |
| 225 | G.I. Strip 35x6mm |
| 226 | Compound filled earthing/Chemical Earthing of Transformer Body(with G.I. Strip 35x6mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B |
| 227 | Compound filled earthing/Chemical Earthing |
| 228 | 8 SWG GI wire |
| 229 | G.I. Strip 35x6mm |
| 230 | Compound filled earthing/Chemical Earthingof Lightning Arrestor with G.I. Strip 35x6mm Annexure C 37 C |
| 231 | Compound filled earthing/Chemical Earthing |
| 232 | G.I. Strip 35x6mm |
| 233 | Alluminium paint (Double Coat) |
| 234 | Red Oxide paints |
| 235 | Grouting with Cement Concreating ratio with 1:3:6 |
| 236 | 33kV Single Busbar Gas Insulated Switchgear: |
| 237 | Supply & Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 station transformer, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required.SCADA compatible/operated as per UPCL specifications. |
| 238 | Incoming 33 KV Double Pole structure of SP-55 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A11) |
| 239 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 240 | 33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, bolts & nuts all galvanized (for DoublePole) |
| 241 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 242 | 33 KV Line isolator Vertical type |
| 243 | 33 KV Fuse set |
| 244 | MS Channel 100x50x6mm 3.2 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for 33 KV Line isolator Vertical type & Fuse set. |
| 245 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 246 | 33 kV Base channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized for Cable GI pipe support |
| 247 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 248 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 249 | 33 KV lightening arrestor |
| 250 | 33 kV Polymer Pin Insulator complete |
| 251 | GI Fish Plate 50x8mm for 33 kv DP |
| 252 | Disc fitting forPanther conductor 90 KN B&S type |
| 253 | 33 kV Composite Polymer Disc Insulator B & S type |
| 254 | 33 kV Danger board with clamp Bolts & Nuts |
| 255 | Wedge connector for Panther |
| 256 | Aluminum Binding wire & tape |
| 257 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 258 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 259 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 260 | 8 SWG GI wire |
| 261 | Alluminium paint (Double Coat) |
| 262 | Red Oxide paints |
| 263 | Grouting with Cement Concreating ratio with 1:3:6 |
| 264 | Stay complete (As per Annex-C-18) |
| 265 | 33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD |
| 266 | Stay Wire 7/8 SWG |
| 267 | 33kv Stay Insulator |
| 268 | Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized |
| 269 | Grouting with Cement Concreating ratio with 1:3:6 |
| 270 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 271 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 272 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 273 | 33 KV Cable jointing kit indoor type suitable for 1Cx630 sq. mm. TR-XLPE cable |
| 274 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 275 | Cable jointing kit indoor type suitable for 3Cx50 sq. mm. TR-XLPE cable 33 KV |
| 276 | 33 kv LA sub station class -II |
| 277 | 11KV MATERIAL |
| 278 | Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required. PT required for each of the bus section. SCADA operated. |
| 279 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 280 | 11 KV TR-XLPE Cable joining kit for 1Cx630 Sq. mm. (Outdoor) |
| 281 | 11 KV TR-XLPE Cable joining kit for 1Cx630 sq. mm. (Indoor) |
| 282 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 283 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm. (Indoor ) |
| 284 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm (Outdoor) |
| 285 | LT MATERIALS |
| 286 | LT Power Cable 3.5Cx70 sq. mm. from station T/F to AC/DB along with suitable lugs and its laying double circuit. |
| 287 | LT Control Cable |
| 288 | 2x2.5 Sq.mm |
| 289 | 4x2.5 Sq.mm |
| 290 | 10x2.5 Sq.mm |
| 291 | LT PVC Cable 2Cx6 sq. mm |
| 292 | LT PVC Cable 4Cx10 sq. mm |
| 293 | DC INSTRUMENTS |
| 294 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 295 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 296 | D.C. Distribution Board of prescribed specification. |
| 297 | AC INSTURMENTS |
| 298 | AC Power distribution board of prescribed specification & lighting system consisting of |
| 299 | AC Power Distribution Board |
| 300 | EARTH MAT/CIVIL WORK |
| 301 | Earth Mat |
| 302 | MS round 32 mm dia 6.21 Kg/mtr for laying earth mat/ 32 No electrodes |
| 303 | Cross Joints welding |
| 304 | T-joints. |
| 305 | lap Joint |
| 306 | G.I. Strip for earthing |
| 307 | a) 75mmx8mm |
| 308 | b) 50mm x 5 mm |
| 309 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm & GI wire 8 SWG with Bolts Clamp, & Nuts All Galvanised.(For Fencing, ACDB & DCDB) Annexure C37 |
| 310 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 311 | 8 SWG GI wire |
| 312 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr or 1 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode in ground so that the top of electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. 33 KV LA, 11 KV LA, 33 KV panels, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 313 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 Annesure N-8 A |
| 314 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 315 | For Power transformer neutrul earthing |
| 316 | For Power transformer body earthing |
| 317 | For Power transformer LA earthing |
| 318 | 11 KV & 33 KV VCB pannel earthing both end |
| 319 | G.I. Strip 35x6mm |
| 320 | MISCELANEOUS |
| 321 | MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for Terminal Gantry Bay, bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt All Galvanised. |
| 322 | Wire mesh fencing with gate, stay support, toe wall, duly painted on both site. |
| 323 | ACSR Panther conductor |
| 324 | Fire fighting accessories including |
| 325 | i) 4 sand bucket with angle iron chuggi type stand. |
| 326 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 327 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 328 | 33KV LINE MISCELLANEOUS MATERIALS |
| 329 | Wedge connector for Panther to Panther |
| 330 | Wedge connector for Panther to Dog |
| 331 | Connectors suitable for Panther. |
| 332 | i) For LA suitable for Panther |
| 333 | ii) For Isolators suitable for Panther |
| 334 | v) For Transformers suitable for Panther. |
| 335 | vii)Reinforcement steel M.S. Bar 12mm |
| 336 | viii) Perforated tray for control cable |
| 337 | 11KV LINE MISCELLANIOUS MATERIALS |
| 338 | Outgoing 11kV Double Pole structure of SP-23 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A10) |
| 339 | Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 340 | 11 kV top channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs( for Double pole) |
| 341 | PP of suitable size for Top portion of STP-410, SP-23 Pole |
| 342 | Lightening Arrestors Polymer (9kV, 5kA) |
| 343 | 11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch |
| 344 | 11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators,fuse barrel etc. |
| 345 | 11 kV channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs(for SP-23 pole)for AB Switch and DO Fuse |
| 346 | PP of suitable size for Middle portion of STP-410, SP-23 Pole |
| 347 | 11 kV Base channel 100x50x6mm 2.2 mtr. Long with clamps,nuts & bolt all galvanized for Cable GI Pipe Support |
| 348 | PP of suitable size for Bottom portion of STP-410, SP-23 Pole |
| 349 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 350 | 11 kV Polymer Pin Insulator complete |
| 351 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 352 | Disc fitting for Dog 70 KN B&S type |
| 353 | 11 kV Danger Board with Clamp with N&B |
| 354 | Wedge connector for DOG |
| 355 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-23 Pole) |
| 356 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 357 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 358 | 8 SWG GI wire |
| 359 | Alluminium paint (Double Coat) |
| 360 | Red Oxide paints |
| 361 | Grouting with Cement Concreating ratio with 1:3:6 |
| 362 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 363 | Disc fitting forPanther conductor 90 KN B&S type |
| 364 | Disc fitting for Dog 70 KN B&S type |
| 365 | Cost of Civil work (including foundation, walls, floor, electrical substation building, outdoor yard Gravelling etc. as per enclosed UPCL drawing) |
| 366 | Items for substation office of reputed make |
| 367 | v) Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room. |
| 368 | vi) Shock treatment charts |
| 369 | vii) Danger Board, |
| 370 | viii) Single Line Diagram Board |
| 371 | ix) First Aid Box |
| 372 | x) Sub-station Name Board |
| 373 | xi) Shut down / Break down board (Bi-lingual Hindi & English) |
| 374 | xii) Breakdown Board |
| 375 | xiii) Max. Min. load Board |
| 376 | xiv) Instruction Board |
| 377 | xvi) HT Hand Gloves |
| 378 | Sign Board 1 No. 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3\"x3\",6mm) and height of board 6 feet from ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)to indicate Name of scheme. |
| 379 | 33 KV Feeder Line : Underground cable |
| 380 | 33 KV new UG |
| 381 | 33 KV UG TR-XLPE 1Cx630 Sq mm Single Ckt. |
| 382 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 383 | CABLE LAYING : Laying, installing, testing & commissioning of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable at the depth not less than 1.5 meter in open trench, proper dressing of trench with bricks and sand works. Making RCC slab for protection of cable loop.,back filling, removal of excess earth from site including earth compression. Cable dia including using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) rollers for cable support, Hydraulic jack for cable drum etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL ) |
| 384 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 385 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 1Cx630 Sqmm) |
| 386 | Laying and pulling of 1Cx630Sqmm cable (4 Run) for cable loop using RCC Slab protection Layer and digging using coventional method including soft sand cushioning 75 mm below and 75 mm above cable,warning tape including cable marking and tagging,supply of all civil material, labour and T&P as per IS 1255 :1983 or latest amendments(as per site require ment) |
| 387 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels(HDD method),back filling, removal of excess earth from site including earth compression,rollers for cable support, Hydraulic jack for cable drum etc. including cable marking & tagging, termination of cable on terminal gantry or RMU and final testing of HT cable |
| 388 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 389 | Supply & Laying of HDPE Pipe PE 80/100 PN6 110 mm dia for HT cable at the depth not less than 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends |
| 390 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels,back filling, removal of excess earth from site including earth compression |
| 391 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 392 | Supply & Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 110 mm Dia for 33 KV 1Cx630 Sq mm TR-XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method |
| 393 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 1Cx630 Sqmm) |
| 394 | Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 100 mm Dia |
| 395 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 396 | PG clamp T-Type (3 Bolt) |
| 397 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 398 | Straight through jointing kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated , screened, armoured, PVC sheathed power cable, heat-shrink type including termite proofing SS mesh and all accessories |
| 399 | Design & construction of Joint Pit Chamber (1 no in 1 KM) for 33 KV cables : conforming to specifications / guidelines of PWD Uttarakhand and approval including supply of civil materials, reinstatement of road / footpath surface as per PWD Uttarakhand requirements. (Estimated quantities are for max dimensions upto 2000 mm (w) x 2000 mm (l) x (h) 1200 mm whereas actual dimensions subject to space availability and approvals) With Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) works and Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for HDPE sheathed including soakpit |
| 400 | i) Excavation of earth in mixed soil |
| 401 | ii) Brick work 1:4 |
| 402 | iii) MS bar 12 mm. |
| 403 | iv) CC 1:1.5:3 |
| 404 | Fabrication of lid support mesh structure for Joint Pits using Galvanised M.S. Channel 125x65x6 mm. |
| 405 | Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) |
| 406 | Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables . |
| 407 | Concrete route marker for HT cable having emboss \" DANGER UPCL 33 KV CABLE BELOW\" and directional arrows |
| 408 | 33 KV UG TR-XLPE 3x400 Sq mm Double Ckt. |
| 409 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 410 | CABLE LAYING : Laying, installing, testing & commissioning of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable at the depth not less than 1.5 meter in open trench, proper dressing of trench with bricks and sand works. Making RCC slab for protection of cable loop.,back filling, removal of excess earth from site including earth compression. Cable dia including using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) rollers for cable support, Hydraulic jack for cable drum etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL ) |
| 411 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 412 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 3x400 Sqmm) |
| 413 | Laying and pulling of 3x400Sqmm cable (DC)for cable loop using RCC Slab protection Layer and digging using coventional method including soft sand cushioning 75 mm below and 75 mm above cable,warning tape including cable marking and tagging,supply of all civil material, labour and T&P as per IS 1255 :1983 or latest amendments(as per site require ment) |
| 414 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels(HDD method),back filling, removal of excess earth from site including earth compression,rollers for cable support, Hydraulic jack for cable drum etc. including cable marking & tagging, termination of cable on terminal gantry or RMU and final testing of HT cable |
| 415 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 416 | Supply & Laying of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable at the depth not less than 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends |
| 417 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels,back filling, removal of excess earth from site including earth compression |
| 418 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 419 | Supply & Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for 33 KV 3Cx300 Sq mm TR-XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method |
| 420 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 3x400 Sqmm) |
| 421 | Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia |
| 422 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 423 | PG clamp T-Type (3 Bolt) |
| 424 | Termination kit for 33 KV Grade, 3-core, 400 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 425 | Straight through jointing kit for 33 KV Grade, 3-core, 400 Sq.mm, Al conductor, XLPE insulated , screened, armoured, PVC sheathed power cable, heat-shrink type including termite proofing SS mesh and all accessories |
| 426 | Design & construction of Joint Pit Chamber (1 no in 1 KM) for 33 KV cables : conforming to specifications / guidelines of PWD Uttarakhand and approval including supply of civil materials, reinstatement of road / footpath surface as per PWD Uttarakhand requirements. (Estimated quantities are for max dimensions upto 2000 mm (w) x 2000 mm (l) x (h) 1200 mm whereas actual dimensions subject to space availability and approvals) With Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) works and Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for HDPE sheathed including soakpit |
| 427 | i) Excavation of earth in mixed soil |
| 428 | ii) Brick work 1:4 |
| 429 | iii) MS bar 12 mm. |
| 430 | iv) CC 1:1.5:3 |
| 431 | Fabrication of lid support mesh structure for Joint Pits using Galvanised M.S. Channel 125x65x6 mm. |
| 432 | Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) |
| 433 | Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables . |
| 434 | Concrete route marker for HT cable having emboss \" DANGER UPCL 33 KV CABLE BELOW\" and directional arrows |
| 435 | New 33 KV Bay With VCB\"s |
| 436 | 33 KV Bay with VCB (SCADA Compatible) |
| 437 | Cost of Earthmat & Delta Earthing of Sub-station (M3) |
| 438 | M.S. Angle 65x65x6mm for cleat at cross joint all galvanized. |
| 439 | M.S Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing |
| 440 | Gravel pitching of size 1/2\" to 3/4\" (20x30x1) |
| 441 | a) 65mmx6mm |
| 442 | G.I. Strip 40x6 mm. |
| 443 | Excavation of earth in mixed soil |
| 444 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 445 | Earthing of structures using G.I. strips including strengthening, cutting, bending & welding with structure and equipments. |
| 446 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 447 | Earthfilling in yard |
| 448 | COST OF TERMINAL GANTRY WITH LA, Line Isolater,Bus Isolator, Post Insulator, CT, Busbar & connectors AT 33/11 KV SUB-STATION (M4) |
| 449 | COST OF TERMINAL GANTRY |
| 450 | M.S. Channel 125x65x65 mm all galvanized. |
| 451 | M.S. Angle 50x50x6mm all galvanized. |
| 452 | M.S. Channel 125x65x65 mm all galvanized. |
| 453 | 33 kV Composite Polymer Disc Insulator B & S type |
| 454 | Disc fitting forPanther conductor 90 KN B&S type |
| 455 | 33 KV lightening arrestor |
| 456 | M.S. bolts & nut with washers all galvanized. |
| 457 | Stone pad 300x300x75 mm. |
| 458 | MS plate 225x225x8 mm thick all galvanized. |
| 459 | Fabrication charges of structure as per approved drawing |
| 460 | Excavation of earth in mixed soil |
| 461 | Grouting with Cement Concreating ratio with 1:3:6 |
| 462 | Cement Plaster 1:4, on top & side walls |
| 463 | Erection of T.G. with LA |
| 464 | COST OF ONE SET OF LINE ISOLATOR |
| 465 | 33 KV Line isolator Vertical type |
| 466 | M.S. Channel 125x65x65 mm all galvanized. |
| 467 | M.S. Angle 75x75x8mm all galvanized. |
| 468 | M.S. Angle 50x50x6mm all galvanized. |
| 469 | M.S. flat 50x6 mm. all galvanized. |
| 470 | M.S. bolts & nut with washers all galvanized. |
| 471 | Fabrication charges of structure as per approved drawing |
| 472 | Excavation of earth in mixed soil |
| 473 | Grouting with Cement Concreating ratio with 1:3:6 |
| 474 | Cement Plaster 1:4, on top & side walls |
| 475 | Erection charges of isolator structure |
| 476 | Erection charges of line isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator. |
| 477 | COST OF ONE SET OF BUS ISOLATOR |
| 478 | 33KV 3 Pole, Bus Isolator. |
| 479 | M.S. Channel 125x65x65 mm all galvanized. |
| 480 | M.S. Angle 75x75x8mm all galvanized. |
| 481 | M.S. Angle 50x50x6mm all galvanized. |
| 482 | M.S. flat 50x6 mm. all galvanized. |
| 483 | M.S. bolts & nut with washers all galvanized. |
| 484 | Fabrication charges of structure as per approved drawing |
| 485 | Excavation of earth in mixed soil |
| 486 | Grouting with Cement Concreating ratio with 1:3:6 |
| 487 | Cement Plaster 1:4, on top & side walls |
| 488 | Erection charges of isolator structure |
| 489 | Erection charges of Isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator. |
| 490 | COST OF ONE SET OF 33 KV P.I. |
| 491 | M.S. Channel 125x65x65 mm all galvanized. |
| 492 | M.S. Angle 75x75x8mm all galvanized. |
| 493 | 33KV Post Insulator |
| 494 | MS Plate 225x225x8 mm. all galvanized. |
| 495 | M.S. bolts & nut with washers all galvanized. |
| 496 | Fabrication charges of structure as per approved drawing |
| 497 | Excavation of earth in mixed soil |
| 498 | Grouting with Cement Concreating ratio with 1:3:6 |
| 499 | Cement Plaster 1:4, on top & side walls |
| 500 | Erection charges of structure |
| 501 | Fixing and erection charges of Post Insulator |
| 502 | COST OF ONE SET OF CT |
| 503 | 33KV O/D type CT 400/200/1A with Junction box |
| 504 | M.S. Channel 125x65x65 mm all galvanized. |
| 505 | M.S. Angle 75x75x8mm all galvanized. |
| 506 | MS Plate 400x400x8 mm all galvanized. |
| 507 | M.S. bolts & nut with washers all galvanized. |
| 508 | Fabrication charges of structure as per approved drawing |
| 509 | Excavation of earth in mixed soil |
| 510 | Grouting with Cement Concreating ratio with 1:3:6 |
| 511 | Cement Plaster 1:4, on top & side walls |
| 512 | Erection charges of CT structure |
| 513 | Fixing and erection of CT |
| 514 | COST OF BUS BAR & CONNECTORS |
| 515 | ACSR Panther conductor |
| 516 | ACSR Weasel conductor |
| 517 | Disc fitting forPanther conductor 90 KN B&S type |
| 518 | 33 kV Composite Polymer Disc Insulator B & S type |
| 519 | Wedge connector for Panther to Panther |
| 520 | Wedge connector for Panther to Dog |
| 521 | Connectors suitable for Panther |
| 522 | 1. For LA suitable for panther |
| 523 | 2. For LA suitable for dog/weasel |
| 524 | 3. For Isolators suitable for panther |
| 525 | 4. For Isolators suitable for dog/weasel |
| 526 | 5. For CT/PT suitable for panther/dog |
| 527 | 6. For PI suitable for panther |
| 528 | 7. For , VCB suitable for panther |
| 529 | Labour charges for drawing bus-bar & making connection in each equipment, main & auxilary bus bar. |
| 530 | Cost of 33 KV 1250 AMP, Vaccum Circuit Breaker & C&R Panels (M5) |
| 531 | 33KV, 1250A, 3 Phase outdoor type VCB (SCADA Operated with Relay61850) |
| 532 | 33kV Relay and Control Panel for Double Ckt.(SCADA Operated with Relay61850) |
| 533 | Cost of 33 KV Cable Laying & Control Cable(M6) |
| 534 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 535 | M.S CHANNEL 100X50MMX2.8 MTRX4X10 KG/MTR all galvanized. |
| 536 | 33 KV Cable jointing kit outdoor type suitable for 3Cx400 mm TR-XLPE cable |
| 537 | 33 KV Cable jointing kit indoor type suitable for 3Cx400 sq. mm. TR-XLPE cable |
| 538 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 539 | Laying of 33 kv/11 kv cable by excavation oc cable trench in mixed soil,filling of the sand upto height 250mm from bottom most level of the cable trench thereafter properly laing of the cable by placing brick on the both side of the cable then refilling of the sand from the top so as to cover the cable completely and then placing the bricks on the top of te covered cable, spreadinf of the cable warning tape and covering the tench completely with mixed soil including cost of sand bricks etc. |
| 540 | Filling of cable jointing kit 33 kv |
| 541 | Fabrication charges of structure as per approved drawing |
| 542 | COST OF LAYING LT CONTROL CABLES & CABLE TRENCH |
| 543 | M.S. Angle 50x50x6mm all galvanized. |
| 544 | LT Control Cable |
| 545 | 10x2.5 Sq.mm |
| 546 | 4x2.5 Sq.mm |
| 547 | 2x2.5 Sq.mm |
| 548 | vii)Reinforcement steel M.S. Bar 12mm |
| 549 | Perforated tray 400mm width for cable trench |
| 550 | Perforated tray 300 mm width for cable trench |
| 551 | Perforated tray 100 mm width for cable trench |
| 552 | Fabrication charges of structure as per approved drawing |
| 553 | Making cable trench.including fabrication, fixing of MS angle 50/40X6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc. |
| 554 | Cost of misc. items required for sub-station (M7) |
| 555 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 556 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 557 | D.C. Distribution Board of prescribed specification. |
| 558 | single line diagram board of size 2 1/2x 1 1/2 polyflex board with frame,duly painted & writing |
| 559 | Name plate of equipment TG, LI, BI, PI, BG, CT, PT, CB, LA etc. (Size 9\"x5\" with white base, red border & letter written in red color) |
| 560 | Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland. |
| 561 | AC Power Distribution Board |
| 562 | COST OF FIRE PROTECTION |
| 563 | Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room. |
| 564 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 565 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 566 | Testing of S/s |
| 567 | 33 KV 3 Way Ring Main Unit (RMU) (SCADA Enabled) all complete works |
| 568 | Supply, erection, testing and commissioning of 33 KV 3 Way Ring Main Unit (RMU)(SCADA) |
| 569 | Supply. Erection, Testing and commissioning of 33kV 630A 25kA/1 sec Outdoor Motorised extensible type SF6 insulated RMU (3 Way) with 3nos. VCB Module as incoming/outgoing (VVV) including, auxiliary power transformer and suitable provisions with to connect with FRTU including FPIs in future and including provision for double termination connection at 33 KV terminal, supply & fixing of insulated mats (permanently) for all doors from where operation to be done & also including cable tagging with the help of paint & permanent cable taggers (Aluminium) & nomenclature with the help of paint & embossing as approved by UPCL on panels. (Including all complete works as making foundation and cable trench, GI fencing, chemical earthings and locking arraingment) |
| 570 | Capacitor Bank |
| 571 | 11 KV Capacitor Bank |
| 572 | 12.65 kV, 4800 kVAr, 3-Phase, 50 Hz housed in Outdoor Type IP 5X CRCA Panel, Capacitor bank having seven Variable steps of 150+300+450+600+900+1200+1200 Kvar to be installed at substations . Bank shall be complete with Capacitor units of 400/300/200/150/100/50 kVAr, Aluminium busbars, Pin & Post insulators, HRC fuses etc. Outdoor Type CRCA Panel shall be accomodating capacitors,Series Reactor,Vacuum contactor, Surge suppressor, Fuses, RVT etc. |
| 573 | Indoor Type Automatic Power Factor Controller for Seven steps |
| 574 | LA 11 KV substation type class 3 |
| 575 | Vacuum Circuit Breaker along with C&R Panel for Automatic Capacitor Bank (Indoor/ Outdoor)11kV, 630 Amps indoor/outdoor VCB, C&R Panel, CT unit with mounting structure |
| 576 | Control Cables |
| 577 | 4x2.5 Sq.mm |
| 578 | 6x2.5sq.mm. |
| 579 | 16x2.5sq.mm. |
| 580 | Power Cables |
| 581 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 240 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 582 | 11 KV TR-XLPE Cable jointing kit for 3x240sqmm.(Indoor) |
| 583 | 11 KV TR-XLPE Cable jointing kit for 3x240sqmm.(Outdoor) |
| 584 | 11kV, 630 Amp, Off Load Isolator with earth switch and mounting structure |
| 585 | G.I. Strip 35x6mm |
| 586 | Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc. |
| 587 | Civil Work (Including foundation of Capacitor Cubical etc.)as per manufactrer recommendation and aprroved drawing by UPCL including supply of all civil materials,Complete |
| 588 | New Substation (SCADA Enabled) |
| 589 | New Substation 2x12.5 MVA Indoor type GIS |
| 590 | Substation |
| 591 | 33 KV MATERIAL |
| 592 | 12.5 MVA, 33/11 KV Power T/F With on-load tap changer including all fitting & accessories etc.(As per UPCL specifications) including loading and unloading. |
| 593 | Concreting of power X\"mer foundation including rail 90 Lbs(482kg),ms angle 50x50x6 mm( 74 kg), MS bar 12 mm dia(116 kg),Excavation of earth in mixed soil(5.776 cmt.),CC 1:4:8(4.344 cmt),Brick work in 1:4(1.147 cmt),RCC 1:1.5:3(2.7 cmt),Plaster in 1:4 (12 sqm). Minimum Height from ground level should be 3 feet. |
| 594 | 33/0.4 KV 25 KVA Station Transformer as per UPCL specifications. (as per Annex-A9) |
| 595 | 33/0.433 KV, 25 KVA Station Transformer |
| 596 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 597 | MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 598 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 599 | MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 600 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 601 | 33 KV Line isolator Vertical type |
| 602 | 33 KV Fuse set |
| 603 | MS Channel 100x50x6mm 2 no. 2.8 mtr. Long with Clamp,Nuts & Bolts for AB Switch all galvanized as per SBD specs for SP-55 Pole. |
| 604 | MS Channel 100x50x6mm 2.8 mtr. Long with Clamp, Nuts & Bolts for DO fuse set all galvanized as per SBD specs for SP-55 Pole . |
| 605 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 606 | 33 KV lightening arrestor |
| 607 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 608 | 33 kV Danger board with clamp Bolts & Nuts |
| 609 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 610 | Insulators for holding earthing strip of lightening arrestor & transformer neutral |
| 611 | G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator |
| 612 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 613 | LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 25 kVA T/F. |
| 614 | Three phase LT-CT operated Smart Meter (with Supply & Erection Charge) for Station/ Distribution Transformer with metering Cubical, CTs etc (Three Phase, Four Wire, Energy Meter for 3-Phase 25 kVA Distribution Transformer) |
| 615 | LTDB & DTR metering channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs For SP-55 |
| 616 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 617 | Rod type earthing complete for pole,LT Panel & metering Cubical with GI wire 6 SWG Annexure C37 |
| 618 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 619 | 8 SWG GI wire |
| 620 | Compound filled earthing/Chemical Earthing(with G.I. Strip 35x6mm for Neutral Earthing of Transformer Annexure C 37 A |
| 621 | Compound filled earthing/Chemical Earthing |
| 622 | G.I. Strip 35x6mm |
| 623 | Compound filled earthing/Chemical Earthing of Transformer Body(with G.I. Strip 35x6mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B |
| 624 | Compound filled earthing/Chemical Earthing |
| 625 | 8 SWG GI wire |
| 626 | G.I. Strip 35x6mm |
| 627 | Compound filled earthing/Chemical Earthingof Lightning Arrestor with G.I. Strip 35x6mm Annexure C 37 C |
| 628 | Compound filled earthing/Chemical Earthing |
| 629 | G.I. Strip 35x6mm |
| 630 | Alluminium paint (Double Coat) |
| 631 | Red Oxide paints |
| 632 | Grouting with Cement Concreating ratio with 1:3:6 |
| 633 | 33kV Single Busbar Gas Insulated Switchgear: |
| 634 | Supply & Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 station transformer, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required.SCADA compatible/operated as per UPCL specifications. |
| 635 | Incoming 33 KV Double Pole structure of SP-55 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A11) |
| 636 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 637 | 33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, bolts & nuts all galvanized (for DoublePole) |
| 638 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 639 | 33 KV Line isolator Vertical type |
| 640 | 33 KV Fuse set |
| 641 | MS Channel 100x50x6mm 3.2 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for 33 KV Line isolator Vertical type & Fuse set. |
| 642 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 643 | 33 kV Base channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized for Cable GI pipe support |
| 644 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 645 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 646 | 33 KV lightening arrestor |
| 647 | 33 kV Polymer Pin Insulator complete |
| 648 | GI Fish Plate 50x8mm for 33 kv DP |
| 649 | Disc fitting forPanther conductor 90 KN B&S type |
| 650 | 33 kV Composite Polymer Disc Insulator B & S type |
| 651 | 33 kV Danger board with clamp Bolts & Nuts |
| 652 | Wedge connector for Panther |
| 653 | Aluminum Binding wire & tape |
| 654 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 655 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 656 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 657 | 8 SWG GI wire |
| 658 | Alluminium paint (Double Coat) |
| 659 | Red Oxide paints |
| 660 | Grouting with Cement Concreating ratio with 1:3:6 |
| 661 | Stay complete (As per Annex-C-18) |
| 662 | 33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD |
| 663 | Stay Wire 7/8 SWG |
| 664 | 33kv Stay Insulator |
| 665 | Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized |
| 666 | Grouting with Cement Concreating ratio with 1:3:6 |
| 667 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 668 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 669 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 670 | 33 KV Cable jointing kit indoor type suitable for 1Cx630 sq. mm. TR-XLPE cable |
| 671 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 672 | Cable jointing kit indoor type suitable for 3Cx50 sq. mm. TR-XLPE cable 33 KV |
| 673 | 33 kv LA sub station class -II |
| 674 | 11KV MATERIAL |
| 675 | Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required. PT required for each of the bus section. SCADA operated. |
| 676 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 677 | 11 KV TR-XLPE Cable joining kit for 1Cx630 Sq. mm. (Outdoor) |
| 678 | 11 KV TR-XLPE Cable joining kit for 1Cx630 sq. mm. (Indoor) |
| 679 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 680 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm. (Indoor ) |
| 681 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm (Outdoor) |
| 682 | LT MATERIALS |
| 683 | LT Power Cable 3.5Cx70 sq. mm. from station T/F to AC/DB along with suitable lugs and its laying double circuit. |
| 684 | LT Control Cable |
| 685 | 2x2.5 Sq.mm |
| 686 | 4x2.5 Sq.mm |
| 687 | 10x2.5 Sq.mm |
| 688 | LT PVC Cable 2Cx6 sq. mm |
| 689 | LT PVC Cable 4Cx10 sq. mm |
| 690 | DC INSTRUMENTS |
| 691 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 692 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 693 | D.C. Distribution Board of prescribed specification. |
| 694 | AC INSTURMENTS |
| 695 | AC Power distribution board of prescribed specification & lighting system consisting of |
| 696 | AC Power Distribution Board |
| 697 | EARTH MAT/CIVIL WORK |
| 698 | Earth Mat |
| 699 | MS round 32 mm dia 6.21 Kg/mtr for laying earth mat/ 32 No electrodes |
| 700 | Cross Joints welding |
| 701 | T-joints. |
| 702 | lap Joint |
| 703 | G.I. Strip for earthing |
| 704 | a) 75mmx8mm |
| 705 | b) 50mm x 5 mm |
| 706 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm & GI wire 8 SWG with Bolts Clamp, & Nuts All Galvanised.(For Fencing, ACDB & DCDB) Annexure C37 |
| 707 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 708 | 8 SWG GI wire |
| 709 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr or 1 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode in ground so that the top of electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. 33 KV LA, 11 KV LA, 33 KV panels, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 710 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 Annesure N-8 A |
| 711 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 712 | For Power transformer neutrul earthing |
| 713 | For Power transformer body earthing |
| 714 | For Power transformer LA earthing |
| 715 | 11 KV & 33 KV VCB pannel earthing both end |
| 716 | G.I. Strip 35x6mm |
| 717 | MISCELANEOUS |
| 718 | MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for Terminal Gantry Bay, bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt All Galvanised. |
| 719 | Wire mesh fencing with gate, stay support, toe wall, duly painted on both site. |
| 720 | ACSR Panther conductor |
| 721 | Fire fighting accessories including |
| 722 | i) 4 sand bucket with angle iron chuggi type stand. |
| 723 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 724 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 725 | 33KV LINE MISCELLANEOUS MATERIALS |
| 726 | Wedge connector for Panther to Panther |
| 727 | Wedge connector for Panther to Dog |
| 728 | Connectors suitable for Panther. |
| 729 | i) For LA suitable for Panther |
| 730 | ii) For Isolators suitable for Panther |
| 731 | v) For Transformers suitable for Panther. |
| 732 | vii)Reinforcement steel M.S. Bar 12mm |
| 733 | viii) Perforated tray for control cable |
| 734 | 11KV LINE MISCELLANIOUS MATERIALS |
| 735 | Outgoing 11kV Double Pole structure of SP-23 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A10) |
| 736 | Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 737 | 11 kV top channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs( for Double pole) |
| 738 | PP of suitable size for Top portion of STP-410, SP-23 Pole |
| 739 | Lightening Arrestors Polymer (9kV, 5kA) |
| 740 | 11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch |
| 741 | 11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators,fuse barrel etc. |
| 742 | 11 kV channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs(for SP-23 pole)for AB Switch and DO Fuse |
| 743 | PP of suitable size for Middle portion of STP-410, SP-23 Pole |
| 744 | 11 kV Base channel 100x50x6mm 2.2 mtr. Long with clamps,nuts & bolt all galvanized for Cable GI Pipe Support |
| 745 | PP of suitable size for Bottom portion of STP-410, SP-23 Pole |
| 746 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 747 | 11 kV Polymer Pin Insulator complete |
| 748 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 749 | Disc fitting for Dog 70 KN B&S type |
| 750 | 11 kV Danger Board with Clamp with N&B |
| 751 | Wedge connector for DOG |
| 752 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-23 Pole) |
| 753 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 754 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 755 | 8 SWG GI wire |
| 756 | Alluminium paint (Double Coat) |
| 757 | Red Oxide paints |
| 758 | Grouting with Cement Concreating ratio with 1:3:6 |
| 759 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 760 | Disc fitting forPanther conductor 90 KN B&S type |
| 761 | Disc fitting for Dog 70 KN B&S type |
| 762 | Cost of Civil work (including foundation, walls, floor, electrical substation building, outdoor yard Gravelling etc. as per enclosed UPCL drawing) |
| 763 | Items for substation office of reputed make |
| 764 | v) Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room. |
| 765 | vi) Shock treatment charts |
| 766 | vii) Danger Board, |
| 767 | viii) Single Line Diagram Board |
| 768 | ix) First Aid Box |
| 769 | x) Sub-station Name Board |
| 770 | xi) Shut down / Break down board (Bi-lingual Hindi & English) |
| 771 | xii) Breakdown Board |
| 772 | xiii) Max. Min. load Board |
| 773 | xiv) Instruction Board |
| 774 | xvi) HT Hand Gloves |
| 775 | Sign Board 1 No. 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3\"x3\",6mm) and height of board 6 feet from ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)to indicate Name of scheme. |
| 776 | New Substation 2x10 MVA Indoor type GIS |
| 777 | Substation |
| 778 | 33 KV MATERIAL |
| 779 | 10 MVA, 33/11 KV Power T/F With on-load tap changer including all fitting & accessories etc.(As per UPCL specifications) including loading and unloading. |
| 780 | Concreting of power X\"mer foundation including rail 90 Lbs(482kg),ms angle 50x50x6 mm( 74 kg), MS bar 12 mm dia(116 kg),Excavation of earth in mixed soil(5.776 cmt.),CC 1:4:8(4.344 cmt),Brick work in 1:4(1.147 cmt),RCC 1:1.5:3(2.7 cmt),Plaster in 1:4 (12 sqm). Minimum Height from ground level should be 3 feet. |
| 781 | 33/0.4 KV 25 KVA Station Transformer as per UPCL specifications. (as per Annex-A9) |
| 782 | 33/0.433 KV, 25 KVA Station Transformer |
| 783 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 784 | MS Channel 125x65x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 785 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 786 | MS Channel 125x65x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment Nuts & Bolts all galvanized as per SBD specs |
| 787 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 788 | 33 KV Line isolator Vertical type |
| 789 | 33 KV Fuse set |
| 790 | MS Channel 100x50x6mm 2 no. 2.8 mtr. Long with Clamp,Nuts & Bolts for AB Switch all galvanized as per SBD specs for SP-55 Pole. |
| 791 | MS Channel 100x50x6mm 2.8 mtr. Long with Clamp, Nuts & Bolts for DO fuse set all galvanized as per SBD specs for SP-55 Pole . |
| 792 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 793 | 33 KV lightening arrestor |
| 794 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 795 | 33 kV Danger board with clamp Bolts & Nuts |
| 796 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 797 | Insulators for holding earthing strip of lightening arrestor & transformer neutral |
| 798 | G.I.pipe 40/50 mm out.dia. & thickness 4/5 mm, 6 mtr. Long for making opearting mechanism for vertical bus isolator |
| 799 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 800 | LT panel with protection equipment along with MCCB, Earth Fault Relay (EFR) etc. including fixing arrangement for 25 kVA T/F. |
| 801 | Three phase LT-CT operated Smart Meter (with Supply & Erection Charge) for Station/ Distribution Transformer with metering Cubical, CTs etc (Three Phase, Four Wire, Energy Meter for 3-Phase 25 kVA Distribution Transformer) |
| 802 | LTDB & DTR metering channel 100x50x6mm 2.8 mtr. Long with clamp, nuts & bolt all galvanized as per SBD specs For SP-55 |
| 803 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 804 | Rod type earthing complete for pole,LT Panel & metering Cubical with GI wire 6 SWG Annexure C37 |
| 805 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 806 | 8 SWG GI wire |
| 807 | Compound filled earthing/Chemical Earthing(with G.I. Strip 35x6mm for Neutral Earthing of Transformer Annexure C 37 A |
| 808 | Compound filled earthing/Chemical Earthing |
| 809 | G.I. Strip 35x6mm |
| 810 | Compound filled earthing/Chemical Earthing of Transformer Body(with G.I. Strip 35x6mm),Other structure& Equipment( with GI Wire of 8 SWG) Annexure C 37 B |
| 811 | Compound filled earthing/Chemical Earthing |
| 812 | 8 SWG GI wire |
| 813 | G.I. Strip 35x6mm |
| 814 | Compound filled earthing/Chemical Earthingof Lightning Arrestor with G.I. Strip 35x6mm Annexure C 37 C |
| 815 | Compound filled earthing/Chemical Earthing |
| 816 | G.I. Strip 35x6mm |
| 817 | Alluminium paint (Double Coat) |
| 818 | Red Oxide paints |
| 819 | Grouting with Cement Concreating ratio with 1:3:6 |
| 820 | 33kV Single Busbar Gas Insulated Switchgear: |
| 821 | Supply & Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 station transformer, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required.SCADA compatible/operated as per UPCL specifications. |
| 822 | Incoming 33 KV Double Pole structure of SP-55 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A11) |
| 823 | Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 824 | 33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, bolts & nuts all galvanized (for DoublePole) |
| 825 | PP of suitable size for Top portion of STP-410, SP-55 Pole |
| 826 | 33 KV Line isolator Vertical type |
| 827 | 33 KV Fuse set |
| 828 | MS Channel 100x50x6mm 3.2 mtr. Long, Clamp,Nuts&Bolts all galvanized as per SBD specs for 33 KV Line isolator Vertical type & Fuse set. |
| 829 | PP of suitable size for Middle portion of STP-410, SP-55 Pole |
| 830 | 33 kV Base channel 125x65x6mm 3.2 mtr. Long with clamp, nuts & bolt all galvanized for Cable GI pipe support |
| 831 | PP of suitable size for Bottom portion of STP-410, SP-55 Pole |
| 832 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 833 | 33 KV lightening arrestor |
| 834 | 33 kV Polymer Pin Insulator complete |
| 835 | GI Fish Plate 50x8mm for 33 kv DP |
| 836 | Disc fitting forPanther conductor 90 KN B&S type |
| 837 | 33 kV Composite Polymer Disc Insulator B & S type |
| 838 | 33 kV Danger board with clamp Bolts & Nuts |
| 839 | Wedge connector for Panther |
| 840 | Aluminum Binding wire & tape |
| 841 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-55 Pole) |
| 842 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 843 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 844 | 8 SWG GI wire |
| 845 | Alluminium paint (Double Coat) |
| 846 | Red Oxide paints |
| 847 | Grouting with Cement Concreating ratio with 1:3:6 |
| 848 | Stay complete (As per Annex-C-18) |
| 849 | 33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD |
| 850 | Stay Wire 7/8 SWG |
| 851 | 33kv Stay Insulator |
| 852 | Stay Clamp (50x8mm) with Nuts, Bolts & warshers all galvanized |
| 853 | Grouting with Cement Concreating ratio with 1:3:6 |
| 854 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 855 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 50 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 856 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 857 | 33 KV Cable jointing kit indoor type suitable for 1Cx630 sq. mm. TR-XLPE cable |
| 858 | Cable jointing kit outdoor type suitable for 3Cx50 mm TR-XLPE cable 33 KV. |
| 859 | Cable jointing kit indoor type suitable for 3Cx50 sq. mm. TR-XLPE cable 33 KV |
| 860 | 33 kv LA sub station class -II |
| 861 | 11KV MATERIAL |
| 862 | Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, one bus coupler/riser bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT riser panel etc. if required. PT required for each of the bus section. SCADA operated. |
| 863 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 864 | 11 KV TR-XLPE Cable joining kit for 1Cx630 Sq. mm. (Outdoor) |
| 865 | 11 KV TR-XLPE Cable joining kit for 1Cx630 sq. mm. (Indoor) |
| 866 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 867 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm. (Indoor ) |
| 868 | 11 KV TR-XLPE Cable jointing kit for 3x400 sq. mm (Outdoor) |
| 869 | LT MATERIALS |
| 870 | LT Power Cable 3.5Cx70 sq. mm. from station T/F to AC/DB along with suitable lugs and its laying double circuit. |
| 871 | LT Control Cable |
| 872 | 2x2.5 Sq.mm |
| 873 | 4x2.5 Sq.mm |
| 874 | 10x2.5 Sq.mm |
| 875 | LT PVC Cable 2Cx6 sq. mm |
| 876 | LT PVC Cable 4Cx10 sq. mm |
| 877 | DC INSTRUMENTS |
| 878 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 879 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 880 | D.C. Distribution Board of prescribed specification. |
| 881 | AC INSTURMENTS |
| 882 | AC Power distribution board of prescribed specification & lighting system consisting of |
| 883 | AC Power Distribution Board |
| 884 | EARTH MAT/CIVIL WORK |
| 885 | Earth Mat |
| 886 | MS round 32 mm dia 6.21 Kg/mtr for laying earth mat/ 32 No electrodes |
| 887 | Cross Joints welding |
| 888 | T-joints. |
| 889 | lap Joint |
| 890 | G.I. Strip for earthing |
| 891 | a) 75mmx8mm |
| 892 | b) 50mm x 5 mm |
| 893 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm & GI wire 8 SWG with Bolts Clamp, & Nuts All Galvanised.(For Fencing, ACDB & DCDB) Annexure C37 |
| 894 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 895 | 8 SWG GI wire |
| 896 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr or 1 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode in ground so that the top of electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. 33 KV LA, 11 KV LA, 33 KV panels, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 897 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 Annesure N-8 A |
| 898 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 899 | For Power transformer neutrul earthing |
| 900 | For Power transformer body earthing |
| 901 | For Power transformer LA earthing |
| 902 | 11 KV & 33 KV VCB pannel earthing both end |
| 903 | G.I. Strip 35x6mm |
| 904 | MISCELANEOUS |
| 905 | MS (RS Joist, MS Channel, MS angle,Rail as per RESPO drawings enclosed) for Misc. structures for Terminal Gantry Bay, bus bar gantry, LA, CT, PT, PI, Isolators etc. as per drawings & design and site conditions including fabrication, welding, nut & bolt All Galvanised. |
| 906 | Wire mesh fencing with gate, stay support, toe wall, duly painted on both site. |
| 907 | ACSR Panther conductor |
| 908 | Fire fighting accessories including |
| 909 | i) 4 sand bucket with angle iron chuggi type stand. |
| 910 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 911 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 912 | 33KV LINE MISCELLANEOUS MATERIALS |
| 913 | Wedge connector for Panther to Panther |
| 914 | Wedge connector for Panther to Dog |
| 915 | Connectors suitable for Panther. |
| 916 | i) For LA suitable for Panther |
| 917 | ii) For Isolators suitable for Panther |
| 918 | v) For Transformers suitable for Panther. |
| 919 | vii)Reinforcement steel M.S. Bar 12mm |
| 920 | viii) Perforated tray for control cable |
| 921 | 11KV LINE MISCELLANIOUS MATERIALS |
| 922 | Outgoing 11kV Double Pole structure of SP-23 complete with Top channel for holding cable & necessary clamps etc.(As per Anexure A10) |
| 923 | Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6) |
| 924 | 11 kV top channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs( for Double pole) |
| 925 | PP of suitable size for Top portion of STP-410, SP-23 Pole |
| 926 | Lightening Arrestors Polymer (9kV, 5kA) |
| 927 | 11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch |
| 928 | 11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators,fuse barrel etc. |
| 929 | 11 kV channel 100x50x6mm 2.2 mtr. Long with nuts & bolt all galvanized as per SBD specs(for SP-23 pole)for AB Switch and DO Fuse |
| 930 | PP of suitable size for Middle portion of STP-410, SP-23 Pole |
| 931 | 11 kV Base channel 100x50x6mm 2.2 mtr. Long with clamps,nuts & bolt all galvanized for Cable GI Pipe Support |
| 932 | PP of suitable size for Bottom portion of STP-410, SP-23 Pole |
| 933 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 934 | 11 kV Polymer Pin Insulator complete |
| 935 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 936 | Disc fitting for Dog 70 KN B&S type |
| 937 | 11 kV Danger Board with Clamp with N&B |
| 938 | Wedge connector for DOG |
| 939 | Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 m per pole) with top and bottam Clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized for SP-23 Pole) |
| 940 | Rod type earthing of pole by MS earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 Annexure C37 |
| 941 | Rod type earthing of pole by MS earthing rod with welded Clamp 40X3mm, Bolts, Washers & Nuts complete . |
| 942 | 8 SWG GI wire |
| 943 | Alluminium paint (Double Coat) |
| 944 | Red Oxide paints |
| 945 | Grouting with Cement Concreating ratio with 1:3:6 |
| 946 | 11 kV Compsite Polymer Disc Insulator B & S type |
| 947 | Disc fitting forPanther conductor 90 KN B&S type |
| 948 | Disc fitting for Dog 70 KN B&S type |
| 949 | Cost of Civil work (including foundation, walls, floor, electrical substation building, outdoor yard Gravelling etc. as per enclosed UPCL drawing) |
| 950 | Items for substation office of reputed make |
| 951 | v) Rubber mat Class C 3 mm Synthetic Insulating Mat- Confirming to IS 15652 : 2006. Along the all equipments in Control Room. |
| 952 | vi) Shock treatment charts |
| 953 | vii) Danger Board, |
| 954 | viii) Single Line Diagram Board |
| 955 | ix) First Aid Box |
| 956 | x) Sub-station Name Board |
| 957 | xi) Shut down / Break down board (Bi-lingual Hindi & English) |
| 958 | xii) Breakdown Board |
| 959 | xiii) Max. Min. load Board |
| 960 | xiv) Instruction Board |
| 961 | xvi) HT Hand Gloves |
| 962 | Sign Board 1 No. 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3\"x3\",6mm) and height of board 6 feet from ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)to indicate Name of scheme. |
| 963 | 33 KV Feeder Line : Underground cable |
| 964 | 33 KV new UG |
| 965 | 33 KV UG TR-XLPE 1Cx630 Sq mm Single Ckt. |
| 966 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 1-core/ 630 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 967 | CABLE LAYING : Laying, installing, testing & commissioning of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable at the depth not less than 1.5 meter in open trench, proper dressing of trench with bricks and sand works. Making RCC slab for protection of cable loop.,back filling, removal of excess earth from site including earth compression. Cable dia including using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) rollers for cable support, Hydraulic jack for cable drum etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL ) |
| 968 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 969 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 1Cx630 Sqmm) |
| 970 | Laying and pulling of 1Cx630Sqmm cable (4 Run) for cable loop using RCC Slab protection Layer and digging using coventional method including soft sand cushioning 75 mm below and 75 mm above cable,warning tape including cable marking and tagging,supply of all civil material, labour and T&P as per IS 1255 :1983 or latest amendments(as per site require ment) |
| 971 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels(HDD method),back filling, removal of excess earth from site including earth compression,rollers for cable support, Hydraulic jack for cable drum etc. including cable marking & tagging, termination of cable on terminal gantry or RMU and final testing of HT cable |
| 972 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 973 | Supply & Laying of HDPE Pipe PE 80/100 PN6 110 mm dia for HT cable at the depth not less than 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends |
| 974 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels,back filling, removal of excess earth from site including earth compression |
| 975 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 976 | Supply & Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 110 mm Dia for 33 KV 1Cx630 Sq mm TR-XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method |
| 977 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 1Cx630 Sqmm) |
| 978 | Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 100 mm Dia |
| 979 | Laying and Pulling of 33kV (E) 1cx630mm2 TR-TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 980 | PG clamp T-Type (3 Bolt) |
| 981 | Termination kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 982 | Straight through jointing kit for 33 KV Grade, 1-core, 630 Sq.mm, Al conductor, XLPE insulated , screened, armoured, PVC sheathed power cable, heat-shrink type including termite proofing SS mesh and all accessories |
| 983 | Design & construction of Joint Pit Chamber (1 no in 1 KM) for 33 KV cables : conforming to specifications / guidelines of PWD Uttarakhand and approval including supply of civil materials, reinstatement of road / footpath surface as per PWD Uttarakhand requirements. (Estimated quantities are for max dimensions upto 2000 mm (w) x 2000 mm (l) x (h) 1200 mm whereas actual dimensions subject to space availability and approvals) With Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) works and Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for HDPE sheathed including soakpit |
| 984 | i) Excavation of earth in mixed soil |
| 985 | ii) Brick work 1:4 |
| 986 | iii) MS bar 12 mm. |
| 987 | iv) CC 1:1.5:3 |
| 988 | Fabrication of lid support mesh structure for Joint Pits using Galvanised M.S. Channel 125x65x6 mm. |
| 989 | Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) |
| 990 | Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables . |
| 991 | Concrete route marker for HT cable having emboss \" DANGER UPCL 33 KV CABLE BELOW\" and directional arrows |
| 992 | 33 KV UG TR-XLPE 3x400 Sq mm Double Ckt. |
| 993 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 994 | CABLE LAYING : Laying, installing, testing & commissioning of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable at the depth not less than 1.5 meter in open trench, proper dressing of trench with bricks and sand works. Making RCC slab for protection of cable loop.,back filling, removal of excess earth from site including earth compression. Cable dia including using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) rollers for cable support, Hydraulic jack for cable drum etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL ) |
| 995 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 996 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 3x400 Sqmm) |
| 997 | Laying and pulling of 3x400Sqmm cable (DC)for cable loop using RCC Slab protection Layer and digging using coventional method including soft sand cushioning 75 mm below and 75 mm above cable,warning tape including cable marking and tagging,supply of all civil material, labour and T&P as per IS 1255 :1983 or latest amendments(as per site require ment) |
| 998 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using motorised mechanical cable pullers, cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels(HDD method),back filling, removal of excess earth from site including earth compression,rollers for cable support, Hydraulic jack for cable drum etc. including cable marking & tagging, termination of cable on terminal gantry or RMU and final testing of HT cable |
| 999 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 1000 | Supply & Laying of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable at the depth not less than 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends |
| 1001 | Laying and installing, testing & commissioning of HT cable at the depth not less than 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels,back filling, removal of excess earth from site including earth compression |
| 1002 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 1003 | Supply & Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for 33 KV 3Cx300 Sq mm TR-XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method |
| 1004 | Making of Trench using conventional excavation method at requisite depth as per Approved Drawing by UPCL. (New UG Line 3x400 Sqmm) |
| 1005 | Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including Bell Mouth, long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia |
| 1006 | Laying and Pulling of 33kV (E) 3cx400mm2 TR-XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) |
| 1007 | PG clamp T-Type (3 Bolt) |
| 1008 | Termination kit for 33 KV Grade, 3-core, 400 Sq.mm, Al conductor, XLPE insulated, screened, armoured, PVC sheathed power cable, OUTDOOR / heat-shrinkable type including screen and armour earth kits, all accessories and lugs. |
| 1009 | Straight through jointing kit for 33 KV Grade, 3-core, 400 Sq.mm, Al conductor, XLPE insulated , screened, armoured, PVC sheathed power cable, heat-shrink type including termite proofing SS mesh and all accessories |
| 1010 | Design & construction of Joint Pit Chamber (1 no in 1 KM) for 33 KV cables : conforming to specifications / guidelines of PWD Uttarakhand and approval including supply of civil materials, reinstatement of road / footpath surface as per PWD Uttarakhand requirements. (Estimated quantities are for max dimensions upto 2000 mm (w) x 2000 mm (l) x (h) 1200 mm whereas actual dimensions subject to space availability and approvals) With Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) works and Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for HDPE sheathed including soakpit |
| 1011 | i) Excavation of earth in mixed soil |
| 1012 | ii) Brick work 1:4 |
| 1013 | iii) MS bar 12 mm. |
| 1014 | iv) CC 1:1.5:3 |
| 1015 | Fabrication of lid support mesh structure for Joint Pits using Galvanised M.S. Channel 125x65x6 mm. |
| 1016 | Galvanised M.S. Channel 125x65x6 mm. (for frabrication of lid support mesh structure) |
| 1017 | Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables . |
| 1018 | Concrete route marker for HT cable having emboss \" DANGER UPCL 33 KV CABLE BELOW\" and directional arrows |
| 1019 | New 33 KV Bay With VCB\"s |
| 1020 | 33 KV Bay with VCB (SCADA Compatible) |
| 1021 | Cost of Earthmat & Delta Earthing of Sub-station (M3) |
| 1022 | M.S. Angle 65x65x6mm for cleat at cross joint all galvanized. |
| 1023 | M.S Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing |
| 1024 | Gravel pitching of size 1/2\" to 3/4\" (20x30x1) |
| 1025 | a) 65mmx6mm |
| 1026 | G.I. Strip 40x6 mm. |
| 1027 | Excavation of earth in mixed soil |
| 1028 | Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer. |
| 1029 | Earthing of structures using G.I. strips including strengthening, cutting, bending & welding with structure and equipments. |
| 1030 | Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987 |
| 1031 | Earthfilling in yard |
| 1032 | COST OF TERMINAL GANTRY WITH LA, Line Isolater,Bus Isolator, Post Insulator, CT, Busbar & connectors AT 33/11 KV SUB-STATION (M4) |
| 1033 | COST OF TERMINAL GANTRY |
| 1034 | M.S. Channel 125x65x65 mm all galvanized. |
| 1035 | M.S. Angle 50x50x6mm all galvanized. |
| 1036 | M.S. Channel 125x65x65 mm all galvanized. |
| 1037 | 33 kV Composite Polymer Disc Insulator B & S type |
| 1038 | Disc fitting forPanther conductor 90 KN B&S type |
| 1039 | 33 KV lightening arrestor |
| 1040 | M.S. bolts & nut with washers all galvanized. |
| 1041 | Stone pad 300x300x75 mm. |
| 1042 | MS plate 225x225x8 mm thick all galvanized. |
| 1043 | Fabrication charges of structure as per approved drawing |
| 1044 | Excavation of earth in mixed soil |
| 1045 | Grouting with Cement Concreating ratio with 1:3:6 |
| 1046 | Cement Plaster 1:4, on top & side walls |
| 1047 | Erection of T.G. with LA |
| 1048 | COST OF ONE SET OF LINE ISOLATOR |
| 1049 | 33 KV Line isolator Vertical type |
| 1050 | M.S. Channel 125x65x65 mm all galvanized. |
| 1051 | M.S. Angle 75x75x8mm all galvanized. |
| 1052 | M.S. Angle 50x50x6mm all galvanized. |
| 1053 | M.S. flat 50x6 mm. all galvanized. |
| 1054 | M.S. bolts & nut with washers all galvanized. |
| 1055 | Fabrication charges of structure as per approved drawing |
| 1056 | Excavation of earth in mixed soil |
| 1057 | Grouting with Cement Concreating ratio with 1:3:6 |
| 1058 | Cement Plaster 1:4, on top & side walls |
| 1059 | Erection charges of isolator structure |
| 1060 | Erection charges of line isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator. |
| 1061 | COST OF ONE SET OF BUS ISOLATOR |
| 1062 | 33KV 3 Pole, Bus Isolator. |
| 1063 | M.S. Channel 125x65x65 mm all galvanized. |
| 1064 | M.S. Angle 75x75x8mm all galvanized. |
| 1065 | M.S. Angle 50x50x6mm all galvanized. |
| 1066 | M.S. flat 50x6 mm. all galvanized. |
| 1067 | M.S. bolts & nut with washers all galvanized. |
| 1068 | Fabrication charges of structure as per approved drawing |
| 1069 | Excavation of earth in mixed soil |
| 1070 | Grouting with Cement Concreating ratio with 1:3:6 |
| 1071 | Cement Plaster 1:4, on top & side walls |
| 1072 | Erection charges of isolator structure |
| 1073 | Erection charges of Isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator. |
| 1074 | COST OF ONE SET OF 33 KV P.I. |
| 1075 | M.S. Channel 125x65x65 mm all galvanized. |
| 1076 | M.S. Angle 75x75x8mm all galvanized. |
| 1077 | 33KV Post Insulator |
| 1078 | MS Plate 225x225x8 mm. all galvanized. |
| 1079 | M.S. bolts & nut with washers all galvanized. |
| 1080 | Fabrication charges of structure as per approved drawing |
| 1081 | Excavation of earth in mixed soil |
| 1082 | Grouting with Cement Concreating ratio with 1:3:6 |
| 1083 | Cement Plaster 1:4, on top & side walls |
| 1084 | Erection charges of structure |
| 1085 | Fixing and erection charges of Post Insulator |
| 1086 | COST OF ONE SET OF CT |
| 1087 | 33KV O/D type CT 400/200/1A with Junction box |
| 1088 | M.S. Channel 125x65x65 mm all galvanized. |
| 1089 | M.S. Angle 75x75x8mm all galvanized. |
| 1090 | MS Plate 400x400x8 mm all galvanized. |
| 1091 | M.S. bolts & nut with washers all galvanized. |
| 1092 | Fabrication charges of structure as per approved drawing |
| 1093 | Excavation of earth in mixed soil |
| 1094 | Grouting with Cement Concreating ratio with 1:3:6 |
| 1095 | Cement Plaster 1:4, on top & side walls |
| 1096 | Erection charges of CT structure |
| 1097 | Fixing and erection of CT |
| 1098 | COST OF BUS BAR & CONNECTORS |
| 1099 | ACSR Panther conductor |
| 1100 | ACSR Weasel conductor |
| 1101 | Disc fitting forPanther conductor 90 KN B&S type |
| 1102 | 33 kV Composite Polymer Disc Insulator B & S type |
| 1103 | Wedge connector for Panther to Panther |
| 1104 | Wedge connector for Panther to Dog |
| 1105 | Connectors suitable for Panther |
| 1106 | 1. For LA suitable for panther |
| 1107 | 2. For LA suitable for dog/weasel |
| 1108 | 3. For Isolators suitable for panther |
| 1109 | 4. For Isolators suitable for dog/weasel |
| 1110 | 5. For CT/PT suitable for panther/dog |
| 1111 | 6. For PI suitable for panther |
| 1112 | 7. For , VCB suitable for panther |
| 1113 | Labour charges for drawing bus-bar & making connection in each equipment, main & auxilary bus bar. |
| 1114 | Cost of 33 KV 1250 AMP, Vaccum Circuit Breaker & C&R Panels (M5) |
| 1115 | 33KV, 1250A, 3 Phase outdoor type VCB (SCADA Operated with Relay61850) |
| 1116 | 33kV Relay and Control Panel for Double Ckt.(SCADA Operated with Relay61850) |
| 1117 | Cost of 33 KV Cable Laying & Control Cable(M6) |
| 1118 | 19/33 KV (E) grade, Al conductor, Tr-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 400 Sqmm (Colour of Outer sheeth of Cable shall be different from 11 KV & LT cable as specified by UPCL) |
| 1119 | M.S CHANNEL 100X50MMX2.8 MTRX4X10 KG/MTR all galvanized. |
| 1120 | 33 KV Cable jointing kit outdoor type suitable for 3Cx400 mm TR-XLPE cable |
| 1121 | 33 KV Cable jointing kit indoor type suitable for 3Cx400 sq. mm. TR-XLPE cable |
| 1122 | GI pipe 4\" dia. 3mtr long ( for double pole & bus bar gantry) |
| 1123 | Laying of 33 kv/11 kv cable by excavation oc cable trench in mixed soil,filling of the sand upto height 250mm from bottom most level of the cable trench thereafter properly laing of the cable by placing brick on the both side of the cable then refilling of the sand from the top so as to cover the cable completely and then placing the bricks on the top of te covered cable, spreadinf of the cable warning tape and covering the tench completely with mixed soil including cost of sand bricks etc. |
| 1124 | Filling of cable jointing kit 33 kv |
| 1125 | Fabrication charges of structure as per approved drawing |
| 1126 | COST OF LAYING LT CONTROL CABLES & CABLE TRENCH |
| 1127 | M.S. Angle 50x50x6mm all galvanized. |
| 1128 | LT Control Cable |
| 1129 | 10x2.5 Sq.mm |
| 1130 | 4x2.5 Sq.mm |
| 1131 | 2x2.5 Sq.mm |
| 1132 | vii)Reinforcement steel M.S. Bar 12mm |
| 1133 | Perforated tray 400mm width for cable trench |
| 1134 | Perforated tray 300 mm width for cable trench |
| 1135 | Perforated tray 100 mm width for cable trench |
| 1136 | Fabrication charges of structure as per approved drawing |
| 1137 | Making cable trench.including fabrication, fixing of MS angle 50/40X6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc. |
| 1138 | Cost of misc. items required for sub-station (M7) |
| 1139 | Supply & Erection of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 80 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 80AH Battery set and single phase AC input supply. |
| 1140 | Float cum boost battery charger 24V with trickle charging arrangement with all meters of AC/DC voltage & ammeter etc. of prescribed specifications. |
| 1141 | D.C. Distribution Board of prescribed specification. |
| 1142 | single line diagram board of size 2 1/2x 1 1/2 polyflex board with frame,duly painted & writing |
| 1143 | Name plate of equipment TG, LI, BI, PI, BG, CT, PT, CB, LA etc. (Size 9\"x5\" with white base, red border & letter written in red color) |
| 1144 | Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland. |
| 1145 | AC Power Distribution Board |
| 1146 | COST OF FIRE PROTECTION |
| 1147 | Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room. |
| 1148 | ii) Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity. |
| 1149 | iii) Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required |
| 1150 | Testing of S/s |
| 1151 | 33 KV 3 Way Ring Main Unit (RMU) (SCADA Enabled) all complete works |
| 1152 | Supply, erection, testing and commissioning of 33 KV 3 Way Ring Main Unit (RMU)(SCADA) |
| 1153 | Supply. Erection, Testing and commissioning of 33kV 630A 25kA/1 sec Outdoor Motorised extensible type SF6 insulated RMU (3 Way) with 3nos. VCB Module as incoming/outgoing (VVV) including, auxiliary power transformer and suitable provisions with to connect with FRTU including FPIs in future and including provision for double termination connection at 33 KV terminal, supply & fixing of insulated mats (permanently) for all doors from where operation to be done & also including cable tagging with the help of paint & permanent cable taggers (Aluminium) & nomenclature with the help of paint & embossing as approved by UPCL on panels. (Including all complete works as making foundation and cable trench, GI fencing, chemical earthings and locking arraingment) |
| 1154 | Capacitor Bank |
| 1155 | 11 KV Capacitor Bank |
| 1156 | 12.65 kV, 4800 kVAr, 3-Phase, 50 Hz housed in Outdoor Type IP 5X CRCA Panel, Capacitor bank having seven Variable steps of 150+300+450+600+900+1200+1200 Kvar to be installed at substations . Bank shall be complete with Capacitor units of 400/300/200/150/100/50 kVAr, Aluminium busbars, Pin & Post insulators, HRC fuses etc. Outdoor Type CRCA Panel shall be accomodating capacitors,Series Reactor,Vacuum contactor, Surge suppressor, Fuses, RVT etc. |
| 1157 | Indoor Type Automatic Power Factor Controller for Seven steps |
| 1158 | LA 11 KV substation type class 3 |
| 1159 | Vacuum Circuit Breaker along with C&R Panel for Automatic Capacitor Bank (Indoor/ Outdoor)11kV, 630 Amps indoor/outdoor VCB, C&R Panel, CT unit with mounting structure |
| 1160 | Control Cables |
| 1161 | 4x2.5 Sq.mm |
| 1162 | 6x2.5sq.mm. |
| 1163 | 16x2.5sq.mm. |
| 1164 | Power Cables |
| 1165 | 6.35/11 KV (E) grade, Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 240 sqmm (Colour of Outer sheeth of Cable shall be different from 33 KV & LT cable as specified by UPCL) |
| 1166 | 11 KV TR-XLPE Cable jointing kit for 3x240sqmm.(Indoor) |
| 1167 | 11 KV TR-XLPE Cable jointing kit for 3x240sqmm.(Outdoor) |
| 1168 | 11kV, 630 Amp, Off Load Isolator with earth switch and mounting structure |
| 1169 | G.I. Strip 35x6mm |
| 1170 | Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole /Precast CC chamber etc. |
| 1171 | Civil Work (Including foundation of Capacitor Cubical etc.)as per manufactrer recommendation and aprroved drawing by UPCL including supply of all civil materials,Complete |
| 1172 | Indoor type New GIS Substation-1 (Ramjhula, Muni ki Reti) |
| 1173 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 1174 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m |
| 1175 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1176 | Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete. |
| 1177 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 1178 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 1179 | Providing and laying in position cement concrete in ratio 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 1180 | Providing and laying in position specified grade of reinforced cement concrete in ratio 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 1181 | Reinforced cement concrete work in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 1182 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 1183 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 1184 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. |
| 1185 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1186 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1187 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 1188 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges. |
| 1189 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)...Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 1190 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level including the cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1191 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 1192 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 1193 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1194 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1195 | Half brick masonry with F.P.S. brick of class designation 75 in foundations and plinth in. cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1196 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. |
| 1197 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 1198 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 1199 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1200 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 1201 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x63x4 mm |
| 1202 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 1203 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 1204 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 1205 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm |
| 1206 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper |
| 1207 | Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 1208 | Strutural steel work riveted bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 1209 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: ---Hot finished welded type tubes |
| 1210 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. --- |
| 1211 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 1212 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. |
| 1213 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick. |
| 1214 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1215 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 1216 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.75 mm diameter |
| 1217 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.110 mm diameter |
| 1218 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 1219 | 15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6 coarse sand) |
| 1220 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 1221 | 6mm Cement plaster finished with a floating coat of neat cement 1:3. |
| 1222 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : .. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 1223 | Finishing walls with textured exterior paint of required shade for new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1224 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 1225 | Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 1226 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 1227 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 1228 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 1229 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 1230 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 1231 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 1232 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe-----32 mm dia |
| 1233 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1234 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fitting arrangement of approved quality an colour. 450mm long towel rail with total length of 495mm 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 1235 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes |
| 1236 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
| 1237 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 1238 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 1239 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore |
| 1240 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1241 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: 15 mm nominal bore |
| 1242 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore |
| 1243 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore) |
| 1244 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. |
| 1245 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 1246 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For.... fixed portion Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 1247 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 1248 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 1249 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):: With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) |
| 1250 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 1251 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with moduler type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B |
| 1252 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1253 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1254 | Supplying and fixing followingModular type switch/ socket on the existing switch box/ cover including connections : 5/6 amps switch |
| 1255 | Supplying and fixing following Modular type switch/ socket on the existing switch box/ cover including connections : 3 pin 5/6 amp socket outlet |
| 1256 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1257 | Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess including providing and fixing 6 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required(For light plugs to be used in non residential buildings). |
| 1258 | Supplying and fixing suitable size GI box with modular plate and cover in front on ...... providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 1259 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 1260 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1261 | supply and fixing following way, single pole and neuteral, sheet steel, MCB distribution board cosumer unit, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged frount acrylic cover for the MCB knobs, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required.6 way , Double door |
| 1262 | Supply and fixing 5 amps to 32 amps rating, 240 volts, \"C\" serise, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral |
| 1263 | Supply and fixing following rating, 63 amps double pole, 240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 1264 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 1265 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1266 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, earthing etc. complete as required. |
| 1267 | Supply of 20Watt LED Tubelight Philips or equivalent make as approved by E.I. |
| 1268 | Supplying of exhaust Fan 450 mm sweep of Orient or equivalent make as approved by E.I.----------- |
| 1269 | Engaging of suitable beldar for petty work. (Based on DSR Code 114) |
| 1270 | Indoor type New GIS Substation-2 (Bairaj-2/Gumaniwala, Rishikesh) |
| 1271 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 1272 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5m |
| 1273 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1274 | Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete. |
| 1275 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 1276 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 1277 | Providing and laying in position cement concrete in ratio 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 1278 | Providing and laying in position specified grade of reinforced cement concrete in ratio 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 1279 | Reinforced cement concrete work in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 1280 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 1281 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 1282 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. |
| 1283 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1284 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1285 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 1286 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges. |
| 1287 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)...Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 1288 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level including the cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1289 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. |
| 1290 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 1291 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1292 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1293 | Half brick masonry with F.P.S. brick of class designation 75 in foundations and plinth in. cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1294 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. |
| 1295 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 1296 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 1297 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1298 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 1299 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x63x4 mm |
| 1300 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 1301 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 1302 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 1303 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm |
| 1304 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper |
| 1305 | Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 1306 | Strutural steel work riveted bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 1307 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: ---Hot finished welded type tubes |
| 1308 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. --- |
| 1309 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 1310 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate. |
| 1311 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick. |
| 1312 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1313 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 1314 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.75 mm diameter |
| 1315 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.110 mm diameter |
| 1316 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 1317 | 15mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1cement :6 coarse sand) |
| 1318 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 1319 | 6mm Cement plaster finished with a floating coat of neat cement 1:3. |
| 1320 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : .. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 1321 | Finishing walls with textured exterior paint of required shade for new work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1322 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 1323 | Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 1324 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 1325 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 1326 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 1327 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 1328 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 1329 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 1330 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe-----32 mm dia |
| 1331 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1332 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fitting arrangement of approved quality an colour. 450mm long towel rail with total length of 495mm 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 1333 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes |
| 1334 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
| 1335 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 1336 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 1337 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore |
| 1338 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1339 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: 15 mm nominal bore |
| 1340 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore |
| 1341 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 a(15mm nominal bore) |
| 1342 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. |
| 1343 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 1344 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For.... fixed portion Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 1345 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 1346 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 1347 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):: With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) |
| 1348 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 1349 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with moduler type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group B |
| 1350 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1351 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1352 | Supplying and fixing followingModular type switch/ socket on the existing switch box/ cover including connections : 5/6 amps switch |
| 1353 | Supplying and fixing following Modular type switch/ socket on the existing switch box/ cover including connections : 3 pin 5/6 amp socket outlet |
| 1354 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1355 | Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess including providing and fixing 6 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required(For light plugs to be used in non residential buildings). |
| 1356 | Supplying and fixing suitable size GI box with modular plate and cover in front on ...... providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 1357 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 1358 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1359 | supply and fixing following way, single pole and neuteral, sheet steel, MCB distribution board cosumer unit, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged frount acrylic cover for the MCB knobs, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required.6 way , Double door |
| 1360 | Supply and fixing 5 amps to 32 amps rating, 240 volts, \"C\" serise, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral |
| 1361 | Supply and fixing following rating, 63 amps double pole, 240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 1362 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 1363 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1364 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, earthing etc. complete as required. |
| 1365 | Supply of 20Watt LED Tubelight Philips or equivalent make as approved by E.I. |
| 1366 | Supplying of exhaust Fan 450 mm sweep of Orient or equivalent make as approved by E.I.----------- |
| 1367 | Engaging of suitable beldar for petty work. (Based on DSR Code 114) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail