| 1 | Surface dressing not exc 15cm depth in soft soil complete all as specified. |
| 2 | Excavation in trenches n.exc 1.5m deepand n exc 1.5 m in width in hard/dense type of soilfor foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out complete all as specified. |
| 3 | M&L forHardcore of broken stone or boulders n exc 63mm deposited, spread and levelled in layers n exc 15cm thick watered and rammed to a true surface. |
| 4 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregatein fdn filling and mass concrete complete all as specified. |
| 5 | Removing excavated materialexc 1.50 km but n exc 5km and depositing where directed for soils |
| 6 | M & L inwalling of random rubble, uncoursed, Bangalore type masonry,well bonded bedded and solidly hearted, built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4, complete all as specified and directed. |
| 7 | M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 8 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe line, foundation etc, and getting out in soft /loose soil all as directed. |
| 9 | Returning filling in including spreading, leveling, Watering and well ramming in layers not exceeding 25 cm all as directed. |
| 10 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed. |
| 11 | Supply & Fix as in replacement GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 12 | M&L for Screwing existing steel tubing for alterations or additionsor threading in position without taking down of size 50 mm dia complete all asspecified and directed. |
| 13 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm to existing pipe complete all as specified and directed. |
| 14 | S&F in replacementUnions Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, of size 50 mm dia to existing pipe complete all as specified and directed. |
| 15 | Material and Labour for Cutting existing GI/DI pipes of size 80 to 200 mm dia in position for insertion of new tees and socket of size 15/20/25 mm dia Complete all as specified and as directed. |
| 16 | Supply & Fix as in replacement GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 17 | M&L for Screwing existing steel tubing for alterations or additionsor threading in position without taking down of size 40 mm dia complete all asspecified and directed. |
| 18 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm to existing pipe complete all as specified and directed. |
| 19 | S&F in replacementUnions Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, of size 40 mm dia complete all as specified and directed. |
| 20 | Supply & Fix as in replacement GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 21 | M&L for Screwing existing steel tubing for alterations or additionsor threading in position without taking down of size 25 mm dia complete all asspecified and directed. |
| 22 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm to existing pipe complete all as specified and directed. |
| 23 | S&F in replacementUnions Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, of size 25 mm dia complete all as specified and directed. |
| 24 | Supply, installation, testing and commissioning stater panelCPRI Tested suitable for 3 phase 415 Volts of suitable size made out of3.00 mm thick CRCA sheet for outdoor panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation in (1:2:4) type B-1 using 20mm graded stone aggregate as per site/ manufacturer requirementto accomodate to the following :-INCOMING(a)MCCB 4 pole 63 Amp 16 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a)MCB TPN 40 Amp 10 KA - 01 No.(b)MCB 3 pole 32 Amp 10 KA - 01 No.(c)Star delta starter15 HP suitable for Submersible pump along with Suitable motor protection - 01 No. |
| 25 | Material and labour in repair for 3.5 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 26 | Supply and Fix in repairs Rotational moulded polyethylene water storage tankscylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltr complete all as specified and directed. |
| 27 | Supply and Fix in repairs of Nipple suitable for HDPE water tank having Minimum size 20 mm |
| 28 | S & F PTMT Ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or PTMT ferrule and fixed of size 20 mm dia complete all as specified and directed. |
| 29 | Supply and Fix in repairs Rotational moulded polyethylene water storage tankscylindrical vertical with closed top hoisted and fixed in position of capacity 1000 ltr complete all as specified and directed. |
| 30 | Supply and Fix in repairs of Nipple suitable for HDPE water tank having Minimum size 25mm |
| 31 | S & F PTMT Ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or PTMT ferrule and fixed of size 25 mm dia complete all as specified and directed. |
| 32 | M&L for construction of PCC block walling valve pit of size 600mmx 600mm x600mm(internal dimension) including excavation and earth work in any type of soil, with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and shown on drawing. |
| 33 | Supply and fixing in replacement of 50 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including plain fittings like socket/ Tee / Reducer etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 34 | Supply and fixing in replacement of CPVC union of OD 50 mm |
| 35 | Supply and fixing in replacement of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) OD 50mm |
| 36 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 50 mm dia, ISI marked complete all as specified and as directed. |
| 37 | Supply and fixing in replacement of 40 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including plain fittings like socket/ Tee / Reducer etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 38 | Supply and fixing in replacement of CPVC union of OD 40 mm |
| 39 | Supply and fixing in replacement of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) OD 40mm |
| 40 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 40 mm dia, ISI marked complete all as specified and as directed. |
| 41 | Supply and Fix in repairs Rotational moulded polyethylene water storage tankscylindrical vertical with closed top hoisted and fixed in position of capacity 2000 ltr complete all as specified and directed. |
| 42 | Supply and Fix in repairs ofNipple suitable for HDPE water tank having Minimum size 40mm |
| 43 | S & F PTMT Ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or PTMT ferrule and fixed of size 40 mm dia complete all as specified and directed. |
| 44 | Supply & Fix as in replacement GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 45 | M&L for Screwing existing steel tubing for alterations or additionsor threading in position without taking down of size 20 mm dia complete all asspecified and directed. |
| 46 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm to existing pipe complete all as specified and directed. |
| 47 | S&F in replacementUnions Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, of size 20 mm dia complete all as specified and directed. |
| 48 | Supply & Fix as in replacement GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 49 | M&L for Screwing existing steel tubing for alterations or additionsor threading in position without taking down of size 15 mm dia complete all asspecified and directed. |
| 50 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm to existing pipe complete all as specified and directed. |
| 51 | S&F in replacementUnions Both ends screwed to iron pipes, or one flange end bedded in red lead cement, and other end screwed to iron pipe, of size 15 mm dia complete all as specified and directed. |
| 52 | S&F in replacement Bib Tap cast copper alloy, chromium plated fency type of size 15 mm dia complete all as specified and directed. |
| 53 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate bedding upto a height of 45 CM above ground level, including dismanting and taking out unserviceable LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- |
| 54 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The contractor shall submit CPRI approved IP65 certificate and other technical details of polycarbonate modular enclosure as mentioned in BOQ alongwith the make approval.(ii)The Contractor shall submit the drawing for approval of GE before executing the work.(iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 55 | Supply and fixing in replacement of25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including plain fittings like socket/ Tee / Reducer etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 56 | Supply and fixing in replacement of CPVC union of OD 32 mm |
| 57 | Supply and fixing in replacement of CPVC union of OD 25 mm |
| 58 | Supply and fixing in replacement of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) OD 32mm |
| 59 | Supply and fixing in replacement of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) OD 25mm |
| 60 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 32 mm dia, ISI marked complete all as specified and as directed. |
| 61 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 25 mm dia, ISI marked complete all as specified and as directed. |
| 62 | Supply and Fix in repairs Rotational moulded polyethylene water storage tankscylindrical vertical with closed top hoisted and fixed in position of capacity 5000 ltr complete all as specified and directed. |
| 63 | SSupply and Fix in repairs of Nipple suitable for HDPE water tank having Minimum size 50mm |
| 64 | S & F PTMT Ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or PTMT ferrule and fixed of size 50 mm dia complete all as specified and directed. |
| 65 | Supply and fixing in replacement of 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including plain fittings like socket/ Tee / Reducer etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 66 | Supply and fixing in replacement of CPVC union of OD 20 mm |
| 67 | Supply and fixing in replacement of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) OD 20mm |
| 68 | Supply and fixingin repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed. |
| 69 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness shall be considered for paymet. |
| 70 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed . |
| 71 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material to out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 72 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 73 | Supply and Fixing GI tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 74 | Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 75 | Supply, installation, testing and commissioning LTFeeder pillar box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts of suitable size out door made out 3.00 mm thick CRCA sheet of outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 200 Amp and including PCC foundation as per site requairment to accomodated to the following :-INCOMING(a)MCCB 4 pole 63 Amp 16 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos. OUTGOING(a) Weather Proof panelPlug and shocket angled type IP 67Single Phase 1P +N +E, 20 Amp - 04 Nos(b)MCB TPN20 Amp 10 KA - 01 No. (c)MCB SPN20 Amp 10 KA - 02 Nos. |
| 76 | Material and labour in repair for 3.5 core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 77 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. |
| 78 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 79 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 80 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 81 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 82 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 83 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 84 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 85 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 86 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 87 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 88 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 89 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 90 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 91 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 92 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 93 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 94 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 95 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 96 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 97 | Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed. |
| 98 | S&Fin repair Earth continuity conductor or main earthing lead by providing 20 x 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.NOTE : All Joints should be joined by Exothermic Welding or Brazing. |
| 99 | Note :- An amount of Rs 75,388.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |