Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-02-2026 | Other Corrigendum | Other | 18-03-2026 |
| Sl. No. | Item Description |
| 1 | SCH \"A\"/ BOQ PART-I (BUILDING WORK) |
| 2 | M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed. |
| 3 | M&L for RCC (design mix) M-30 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 4 | M&L for RCC (design mix) M-30 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed. |
| 5 | M&L for RCC (design mix) M-30 (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed. |
| 6 | M&L for RCC (design mix) M-30 (20mm graded aggregates) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness; above top of footings including attached pilasters and buttresses complete all as specified and directed. |
| 7 | M&L for formwork for rough finish to sides of pillars, posts, struts, piers, columns and stanchionscomplete all as specified and directed. |
| 8 | M&L for formwork for rough finish to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etccomplete all as specified and directed. |
| 9 | M&L for formworkfor rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed. |
| 10 | M&L for formworkfor rough finish to edge of concrete flats exc 10 cm but n\"exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work, complete all as specified and directed. |
| 11 | M&L for formworkfor rough finish to sides of walls, retaining wall, basement wall etc. complete all as specified and directed. |
| 12 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed. |
| 14 | M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | M&L for precast PCC (1:3:6) type C1 (using 20mm graded aggregate) solid block (200mm thick and exc 10cm in width) masonary work, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 16 | M&L for precast PCC (1:3:6) type C1 (using 20mm graded aggregate) solid block masonary work, 100mm thick or slab 10cm thick (plain or interlockingjoints), straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 17 | M&L for 15mm thick plastering on fair faces of brick/ PCC block wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick in CM (1:4) mixed with @ 200ml per bag WPC (liquid type) and surface finished even and fair complete all as specified and directed.Note :- WPC (Liquid type) shall be deemed included in quoted rate. |
| 18 | Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed. |
| 19 | M&L for 10mm thick rendering on fair faces of brick/ PCC block masonary work or concrete surface in cement plaster (1:6) finished the surface even and fair complete all as specified and directed. |
| 20 | M&L for 5mm thick rendering on fair faces surface in cement plaster (1:3) as in ceiling and fininshed surface even and fair complete all as specified and directed. |
| 21 | M&L for preparation ofnewly plastered surfaces on walland applying two coats of oil emulsion distemperover alkali resistance for primming to distemper for smooth finish of wall complete all as specified and directed. |
| 22 | M&L for preparation ofnewly plastered surfaces of ceillingand applying two coats of oil emulsion distemperover alkali resistance for primming to distemper for smooth finish of wall complete all as specified and directed. |
| 23 | M&L for preparing newly plastered surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489: 2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces as per manufacturer instruction complete all as specified and directed. |
| 24 | M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate. |
| 25 | S&F aluminium anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 26 | S&F aluminium anodised door shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 27 | S&F aluminium anodised window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, aluminium anodised fittings such as peg stay one 150mm long, hinge type B-21 100 long (2Nos), suitable size handle etc. complete all as specified and directed. |
| 28 | S&F 6.3mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden/ PVC/ aluminium beading, in square n\"exc 0.5 sqm in each pane complete all as specified and as directed. |
| 29 | S&F 6mm thick figured glass, pin headed type and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 30 | S&F 12 mm thick prelaminated particle board exterior grade, ISI marked, both side with decorative choice lamination fixed with aluminium frame work complete all as specified and directed. |
| 31 | S&F aluminium anodisedgrill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 32 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube, fixing in same opening complete as all as specified and directed. |
| 33 | S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site complete all as specified and directed. |
| 34 | S&F 1.25mm thick lath steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple, Safety lever locks mild steel with 4 levers and one shop coat of primer, erected in position as indicated complete all as specified and directed. |
| 35 | S&F rolled mild steel section for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 36 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 37 | M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. |
| 38 | M&L for 75 mm thick PCC (1:4:8) type D2, (40 mm graded stone agg) as in sub base of floor/ hardstanding/ footpath complete all as specified and directed. |
| 39 | M&L for 125mm thick PCC (1:2:4) type B2, (40 mm graded stone agg) as in sub base of floor complete all as specified and directed. |
| 40 | M&L for 100mm thick PCC (1:2:4) type B2, (40 mm graded stone agg) as in flooring laid in pannel with suitable joints complete all as specified and directed. |
| 41 | M&L for 30mm thick PCC (1:2:4) type B0(12.5 mm graded stone agg) as in flooring with and including approved metallic floor hardner to make wearproof topping as specified, laid in pannel with suitable dividing strips complete all as specified and directed. |
| 42 | M&L for 20mm thick screed bed or bedding layer in CM (1:3) for laying of floor finishes etc complete all as specified and directed. |
| 43 | M&L for 15mm thick screed bed or bedding layer in CM (1:4) for laying of floor finishes etc complete all as specified and directed. |
| 44 | M&L for 10mm thick rendering on fair faces of brick work or concrete surface in cement plaster (1:3) as in backing coat andfinished the surface even and rough to receive finishes complete all as specified and directed. |
| 45 | M&L for mat finished vitrified tiles of any design and pattern, double charged, 10 mm thick, as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles and area of each tile not excding 0.36 Sqm complete all as specified and directed.Note: Shade of the tiles including Colour, design and pattern shall be got approved by GE. |
| 46 | Description same all as per item No 1.44 above but as in dado/ skirting complete all as specified and directed. |
| 47 | M&L for non skid, joint free, coloured ceramic tiles7-8mm thick (Square/Rectunglar) and area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles complete all as specified and directed.Note:- Shade of the tiles including Colour, design and pattern shall be approved by GE. |
| 48 | M&L for coloured, glazed ceramic tiles (joint free) size 350x250x7-8mm or 450x350x 7-8mm thick as in dado/ skirting/ vertical surface etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, complete all as specified and directed. |
| 49 | M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror finish polishing complete all as specified and as directedNote:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.) |
| 50 | Description same all as per item No 1.48 above but, as in skirting/ dado/ riser of step (10-12mm thick Kota stone) complete all as specified and as directed. |
| 51 | S&F vitreous China wash down water closet pan (Pedestal pattern) incl close seat cover, hinges, fixing accessories and accessories set and cistern with cistern fitting complete, flush pipe incl all joints completeall as specified and directed.Make – Jaquar Cat No-ECS-WHT-851S220NPP or equivalent model of make as specified in appendix. |
| 52 | S&F vitreous china urinal full stall type urinal complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe complete all as specified and directed. |
| 53 | S&F vitreous china wash hand basin, white, flat back, size 600mm x 480mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. |
| 54 | S&F in repair towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden cleats having min weight 190 gms complete all as specified and directed. |
| 55 | SCH \"A\"/ BOQ PART-II (EXCAVATION, EARTH WORK AND SITE CLEARANCE) |
| 56 | Excavating over areas, n exc 1.5m deep and gettingout in any type of soil complete all as specified and directed. |
| 57 | Excavation in trenches n\"exc 1.5 m width and n\"exc 1.5 m in depth for foundation etc / for laying of cable/ pipe etc n\"exc 10 sqm on plan and n\"exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 58 | Excavating in trenches n\"exc 1.5 m width and n\"exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n\"exc 10 sqm on plan and n\"exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 59 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 60 | Removal of surplus soil to a distance n\"exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 61 | SCH \"A\"/ BOQ PART-III (INTERNAL WATER SUPPLY) |
| 62 | S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusionwelded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following size of pipe complete all as specified and directed :- |
| 63 | 16mm outer dia |
| 64 | 20mm outer dia |
| 65 | 25mm outer dia |
| 66 | S&F 15 mm dia bore bib taps,long body, cast copper alloy with fancy type, chromium plated capstan head long body with wall flange, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.Make : JAQUAR, Cat Part No. CON-107KN or equivalent make as specified. |
| 67 | Supply only 15 mm borepillar taps, cast copperalloy, with capstan heads, chromium plated , Fancy type screwed down for pipe, high pressure , with or without l\"ettered \" \"HOT\" or \"COLD\" with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.MAKE: Jaguar, Model CON-021KN (Continental series) or equivalent model of make as specified in appendix. |
| 68 | S&F 15mm bore angular stop valve with flange, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.Make:- Jaquar, Cat Part No. CON-059KN or equivalent of make as specified. |
| 69 | S&F PP-R Gate valves for 32 outer dia of pipe (brass insert) as per requirement of the site, complete all as specified and directed. |
| 70 | S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Min wt 60 gms) complete all as specified and directed. |
| 71 | Supply onlyPVC connection 15 mm size with PTMT nut of 450mm length complete all as specified and directed. |
| 72 | S&F 5000 litres capacity rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 25mm outer dia PP-R pipe as washout pipe 450 mm long with plug and 25mm outer dia PP-R pipe as overflow pipe 600 mm long with fittings completeall as specified and directed. |
| 73 | SCH \"A\"/ BOQ PART-IV (INTERNAL ELECTRIFICATION) |
| 74 | M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit \"medium grade\" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box suitable for housing switches, sockets, fan regulators etc coverED with 3mm thick plastic ocver sheet (hylum) complete all as specified and directed for following:-Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii)If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding. |
| 75 | One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch. |
| 76 | One 5 pin socket out let 5/6 Amp on independent board. |
| 77 | One light point controlled by two way 5 Amp switch. |
| 78 | Descrition same all as per item No 4.01 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. |
| 79 | S&F switch piano, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Anchor Cat Part No- 95111/ 14111or equivalent ofmakes as specified. |
| 80 | S&F switch piano, flush type button 5/6 Amp single pole two way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Anchor Cat Part No- 95111/ 14111or equivalent ofmakes as specified. |
| 81 | S&F switch socket combination, flush type, flush 5 pin, 5 Amp multipurpose complete all as specified and directed. Make: Anchor Cat Part No- 38820/ 50494or equivalent ofmakes as specified. |
| 82 | S&F switch socket combination 2 in 1, 5 pin ,5 and 15 Amp flush type confirming to IS : 3854 and ISI marked complete all as specified and directed.Anchor Cat Part No- 14615 / 95615or equivalent ofmakes as specified. |
| 83 | S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed. Make – Anchor Jumbo Code-39050 / 3224 or equivalent of make as specified. |
| 84 | S&F switch bell push button type 6 Amp single pole complete all as specified and as directed. Make – Anchor Code-14113 or equivalent make as specified. |
| 85 | S&F bell electric DING DONG type,AC, 230V single pole, 2module complete all as specified and as directed. Make – Legrand cat No: 5734 43 or equivalent make as specified. |
| 86 | S&F fan regulator electronic, stepped type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified anddirected. Make: Anchor, Cat Part No 14501/ 95502 or equivalent others make as specified. |
| 87 | S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH,PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:-NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii)The quoted rates shall be deemedto be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface.The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs. |
| 88 | 2x10 Sqmm+ 1x10 Sqmm earth wire with PVC conduit 25mm dia |
| 89 | 2x6 Sqmm+ 1x6 Sqmm earth wire with PVC conduit 20mm dia |
| 90 | 2x4 Sqmm+ 1x4 Sqmm earth wire with PVC conduit 20mm dia or more |
| 91 | 2x2.5 Sqmm+ 1x1.5 Sqmm earth wire with PVC conduit 20mm dia |
| 92 | 4x6 Sqmm+ 2x6 Sqmm earth wire with PVC conduit 25mm dia |
| 93 | S&F 4mm dia GI wire fixed or laid in ducts/ floor/ wall or to poles or any other indicated situation complete all as specified and directed. |
| 94 | S&F connecting & testing, distribution board, 12 way, vertical type, TPN, sheet metalenclosures, double door, 415V, IP-43 protection suitable for 200/ 250 Amp, 4 pole, MCCB as incomer andoutgoings MCB’s TP/SP complete all as specified and directed.Make : Legrand, Cat Part No. 6079 24 or equivalent make as specified. |
| 95 | S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected :- |
| 96 | DB SPN, 8 wayMake :-Legrand Cat Part No-5076 11 or equivalent others make as specified. |
| 97 | DB SPN, 16 wayMake :-Legrand Cat Part No-5076 13 or equivalent others make as specified. |
| 98 | S&F MCCB 200 Amp, 4 Pole,Icu= 36 KA, 50 Hz, 415 V, adjustable type, having thermal magnetic release complete all as specified and directed.Make : Legrand, Cat Part No. 4202 48 or equivalent make as specified. |
| 99 | S&F connecting & testing MCB, 230V/ 415Vwith rupturing capacity 10 KA of following capacity complete all as specified and directed:- |
| 100 | MCB 6 to 32 Amp, SP, \"B\" series/ curve, Make :-Legrand, Cat Part No 4024 31 to 4024 36 or equivalent others make as specified. |
| 101 | MCB 6 to 32 Amp, SPN, \"C\" series/ curve, Make :-Legrand, Cat Part No 4086 09, 4086 12, 4086 14 to 4086 17 or equivalent others make as specified. |
| 102 | MCB 40 to 63 Amp, SPN, \"C\" series/ curve,Make :-Legrand, Cat Part No 4086 18 to 4086 20 or equivalent others make as specified. |
| 103 | MCB 40 to 63 Amp, FP, \"C\" series/ curve, Make :-Legrand, Cat Part No 4087 92 to 4087 94 or equivalent others make as specified. |
| 104 | S&F industrial type socket & plug top of 20Amp, 230V, Single Pole and neutral,sheet metal enclosure with and including MCB of ‘C’ series 10KA of following capacity complete all as directed and specified :-Make :- Legrand, Cat Part No- 5078 11 (socket & plug top) or equivalent others make as specified. |
| 105 | Single pole, 32 Amps, 240 volt. Make :- Legrand, Cat Part No- 4085 95or equivalent others make as specified. |
| 106 | Single Pole, 20 Amps, 240 volt.Make :- Legrand, Cat Part No- 4085 93or equivalent others make as specified. |
| 107 | S&F industrial type socket & plug top of 32Amp, 415V, triple Pole and neutral,sheet metal enclosure with and including single pole MCB of 32Amp, 10KA, \"C\" series complete all as directed and specified.Make :- Legrand, Cat Part No- 5078 18 (socket & plug top) & 4085 87 (MCB) or equivalent others make as specified. |
| 108 | S&F telephone socket RJ-11 with sutter 1 modulecomplete all as specified and as directed. |
| 109 | S&F telephone cable 5 pair complete all as specified and as directed. |
| 110 | S&F ultra slim elegance LED lighting fixture with polycorbonate body, integrated electronic driver, 6500K, 2 feet, energy efficient and environment friendly with and including suitable size cable, of following capacity complete all as directed and specified :- |
| 111 | 10 wattMake :- Havells, Cat Part No- LHEXAWP7UN1W020 or equivalent others make as specified. |
| 112 | 20 wattMake :- Havells, Cat Part No- LHEXAZP7PN1W010 or equivalent others make as specified. |
| 113 | S&F exhaust fan with louver shutter, heavy duty, AC, single phase, 230 V, of size 250 mm sweep, 900 RPM and connecting up with and including suitable sizt of cable from ceiling rose/ connector to exhaust fan complete all as specified and directed. |
| 114 | Supply and hanging ceiling fan five star rating with double ball bearing 350 RPM, 1200mm sweep, working on 140-285 Volts AC 50 Hz, PF 0.99 with super energy efficient BLDC motor & power consumption shall not more than 28W under standard test condition along with down rod, canopy and all accessories, with smart remote control, all as supplied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 volts grade of suitable size (not less than 1.5 sqmm) and length including and making necessary electric connection etc complete all as directed. Note: Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 3 years for any defects developed during the period. |
| 115 | S&F surface mounted LED bay light fitting 100 watt, energy saving, environmental friendly, long life, High-pressure die cast aluminium housing with LEDs as light source, suitable for highlighting architectural features, sports fields or area lightingwith and including suitable size copper cable of required length complete all as specified and directed.Make : Havells, Cat No. JETALEGANZAFLS100WLED757P60DTOTG or equivalent make as specified. |
| 116 | S&F Air circulating fan, wall mounted, 600 mm sweep, 230 Volts, 50 Hz, single phase and connecting up with and including three core flexible cable of size 1.5 Sqmm copper wire from ceiling rose/connector to fan of length not less than 0.5 mtr. complete all as specified and directed. |
| 117 | SCH \"A\"/ BOQ PART-V (EXTERNAL WATER SUPPLY) |
| 118 | S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- |
| 119 | 25mm bore |
| 120 | 40mm bore |
| 121 | S&F stop valve, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size complete all as specified and directed:- |
| 122 | 25mm bore |
| 123 | 40mm bore |
| 124 | M&L for cutting of 80mm bore existing CI/DI pipe lines in position, for insertion of Tee of size 80x80x40mm complete all as specified and directed. Note :- (i) Excavation, earth work and run lead joint required for execution of work shall be shall be deemed included in quoted rate.(ii) CI specials (fittings) shall be deemed included in quoted rate. |
| 125 | SCH \"A\"/ BOQ PART-VI (EXTERNAL ELECTRIFICATION) |
| 126 | S&F including laying, commisioning and testing of 1.1 KV grade XLPE insulated, PVC sheathed, steel armoured, aluminum stranded conductor LT UG cable (Conforming to IS:7098), ISI marked, in trenches / ducts / through GI pipes under roads offollowing size complete all as specified and directed:-Note:- 1. The earth work, GI pipe shall be measured and paid sepretely.2. Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc. |
| 127 | 300 Sqmm, 3½ core. |
| 128 | 95 Sqmm, 3½ core. |
| 129 | 35 Sqmm, 3½ core. |
| 130 | 16 Sqmm, 4 core. |
| 131 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 132 | Supply and laying un-reinforced precast concrete cable cover of class LV, type-1 with peak size 250mm x 150mm x 40mm (ISI marked) for protection of UG cable over sand cushoniing laid in trenches with axis of the cover perpendicular to the axis of the cable complete all as specified and directed. |
| 133 | S&F earth continuity conductor or main earthing lead 32x 6 mm GI striplaidin pipe / fixed to poles or any other indicated situation including jointing using by GI nuts, bolts and washer in addition to welding complete all as shwonin drawings, & all as specified and directed . |
| 134 | S&F 80mm bore galvanized steel water tubing(GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole complete as specified and directed.Note : MS Clamp, nut bolts and washer shall be deemed included in quoted rate for fixing with pole etc. |
| 135 | Supply, installation, commissioning and testing of outdoor type, cubical LT panel board, CPRI approved factory made,powder coated (Siemens grey structural RAL 7032 shade) having minimum thickness 100 micron,suitable for 3 phase 4 wire415 v, 50 Hz and provided with suitable\"U\" type gasket to make it dust/vermin proof & general construction confirming to IS : 8623/93,floor block mounting type made out of 3.15 mm thick CRCA sheet with using 50mm x 50mm x 6mm angle iron frame,factory fabricated duly compartmentalized for each control gear with front & back openable, lockable / operableby keys from both sides having brass chromium plated 19mm dia fancy locks, louvers & air vent gasketfor natural flow of air and to accommodate incommer / outgoing MCCBs and TPN aluminium bus bar of rating not less than the 1.5 timesthe rated capacity of the incommer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size \"F\" class insulator made of non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at aninterval not less than 500mm through out the length of the TPN bus bar and extension links shall not beless than 300mm long supported on same type insulatorsand having provision for termination of incomer and outgoing cables. |
| 136 | All inter connections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5times rated capacity of individual outgoingfeeders & shouldbe insulated with heat shrinkablePVC sleeves.All control wiresshall be with FRLS PVC insulated, unsheathed 2.5 sqmm multistrandedcopper conductor and shall be properly bunched, tied, ferrulated for proper identification and crimped with aequate size of lugs.Thecubicleshall have a bottom channel of size 75x40mm duly coated with zinc metal coating havingthickness not less than 100 microns.A detachable predrilled gland plate of thickness 2 mm powder coated should be used at the bottomwith and including necessary earth work and PCC work for fixing panel legs. The degree of protection for inner shell shall be IP-42 & carry the following items :- |
| 137 | (i) INCOMING :-(a) Ammeter size 96 mm X 96mm, flush mounted digitaltype, three phase of class 1.0 -Qty-01 No. (b) LED Indicator 22.5mm for 12 volts AC/DC supply-Qty-01 set of 3 Nos. (c) Voltmeter size 96 mm X 96mm, flush mounted digitaltype, three phase, class 1.0 -Qty-01No. (d) MCCB, 400Amps, 4 pole, breaking capacity Icu = 36 KA, 415 Volts, AC supply, with adjustable load setting, having thermal magnetic release -Qty- 01 No(ii) OUT GOING :-(a) MCCB, 200 Amps, 3 pole, breaking capacity Icu = 25 KA, 415 Volts, AC supply, with adjustable load setting, having thermal magnetic release -Qty- 02 No(b) MCCB, 63 Amps, 3 pole, breaking capacity Icu = 16 KA, 415 Volts, AC supply, with adjustable load setting, having thermal magnetic release -Qty- 02 No(c) MCCB, 32 Amps, 3 pole, breaking capacity Icu = 16 KA, 415 Volts, AC supply, with adjustable load setting, having thermal magnetic release -Qty- 02 No(d) CT with ratio 400/5Amp-Qty- 01 No |
| 138 | Notes :-1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-rusting/water rinsing/activation/phosphating water rinsing/passivation).2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel3. The panel manufacturer should have following certification:(i) CPRI certification degree of protection IP-54 ( should have IEC:61439-1-2 & IEC:60529 tests)(ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA(iii) CPRI certification rated current for short circuit not less than 5000A4. All the electricals switch gear like MCCBs, MCB should be of same make5. Drawing of panel board should be got approved from GE/AGE (I) before fabrication.6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2. |
| 139 | S&F 35w LED street light luminaire, new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 including 1.5 Meter long bracket made out of light grade GI pipe of suitable dia and all necessary fixing arrangements and connecting with suitable size of cablecomplete all as specified and directed.Make: Havells, Cat Part No.ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent make as specified. |
| 140 | S&F HDGI hexagonal/octagonal pole 5 meter height having top dia 70mm and bottom dia 135mm and thickness 3mm with andincluding 4 Nos \"J\" hook foundation bolts of dia 16mm and 450mm long with base plate complete all as specified and directed. |
| 141 | M&L for excavation in post holes not exceeding 0.5 cum for erection of pole, removing the excavated material to a distance not exceeding 50m and provinding PCC bed and RCC foundation as per the following including form work complete all as specified and directed:-(a) Size of post hole (For exacavation) - 0.45x0.45x1.2m(b) Reinforcement (TMT bar 12mm dia)- 1.7m x 4 Nos = 6.8m(c) Reinforcement (TMT bar 8mm dia)- 1.6m x 7 Nos = 11.2m(d) RCC (M30 grade) column aggregate = 0.4mx.0.4mx1.3m(e) PCC (1:4:8) type D2 as in bed - 450mmx450mmx100mm |
| 142 | SCH \"A\"/ BOQ PART-VII (ROAD, HARDSTANDING & PATH) |
| 143 | M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. |
| 144 | M&L for 150 mm thick PCC (1:3:6) type C2, (40 mm graded stone agg) as in sub base of floor/ hardstanding etc complete all as specified and directed. |
| 145 | M&L for 100mm thick PCC (1:2:4) type B2 (40 mm graded stone agg) as in hard standing/ path, finished even and fair without using extra cement including spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed. |
| 146 | M&L for forming expansion joints 20mm thick and thickness of concrete slab 100mm, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing with sealing compound grade \"B\" complete all as specified and directed. |
| 147 | M&L for forming construction joints 30 mm deep x 10 mm wide filled with sealing compound grade \"B\" complete all as specified and directed. |
| 148 | SCH \"A\"/ BOQ PART-VIII (SEWAGE DISPOSAL) |
| 149 | M&L for PCC (1:3:6) Type C2 (40 mm graded aggregate) as in foundations, filling and mass-concrete in manhole etc complete all as specified and directed. |
| 150 | M&L for concrete bed to pipes in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150mm bore sewer pipe line complete all as specified and directed. |
| 151 | M&L for 150mm bore CI pipe (sand cast), in any length with or without ear, laid in trenches and jointed in CM (1:1) complete all as secified and directed. |
| 152 | M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast,water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 153 | M&L for extra for forming fair finished drain, or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed. |
| 154 | Add or deduct from item No. 8.05 for each 25 mm girth or part thereof over or under 30Cm complete all as specified and directed.Note:- For adjustment only and quantities may be varied (Plus/Minus) to any extend as per site requirement. |
| 155 | M&L for precast PCC (1:3:6) type C1 (using 20mm graded aggregate) solid block masonary work, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 156 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:4) surface finished even and fair complete all as specified and directed. |
| 157 | M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for manholes) and set in CM (1:4) including necessary fair finish formwork complete all as specified and directed. |
| 158 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed. |
| 159 | M&L for mild steel work as in rungs, handle to manhole etc and similar articles conforming to Fe-290(Gde-E-165) complete all as specified and directed. |
| 160 | SCH \"A\"/ BOQ PART-IX (AREA DRAINAGE) |
| 161 | M&L for PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in surface channel and drain including saucer drain and toe wall etc complete all as specified and directed. |
| 162 | M&L for extra for forming fair finished drain, or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed. |
| 163 | Add or deduct from item No. 9.2 for each 25 mm girth or part thereof over or under 30Cm complete all as specified and directed.Note:- For adjustment only and quantities may be varied (Plus/Minus) to any extend as per site requirement. |
| 164 | M&L for precast PCC (1:3:6) type C1 (using 20mm graded aggregate) solid block masonary work, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 165 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:4) surface finished even and fair complete all as specified and directed. |
| 166 | SCH \"A\"/ BOQ PART-X (LIGHTENING PROTECTION) |
| 167 | S&F air termination rod single pointed, aluminium rod 2mm dia and 300mm long as specified in SSR Part-I (2009) complete all as specified and as directed. |
| 168 | S&F test point terminal box made of gun metal or phosphorous brounze of size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed |
| 169 | S&F aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed |
| 170 | SCH \"A\"/ BOQ PART-XI (AIR CONDITIONING AND WATER COOLERS) |
| 171 | Supply, installation, commissioning and testing of electric driven water cooler of single phase having capacity of 80 litres and normal cooling capacity 40 litres/ hour complete all as specified and directed. |
| 172 | Supply, installation, commissioning and testing of Hi wall split type airconditioningunits indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5TR (4500 Kcal/Hr) complete of comprising of the following:-(a) Room evaporative indoor unit with three speed blower fanof appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water.(b) Out door condensing unit of capacity 4500 K Cal / Hrs comprising of 01 no. compressor of 1.5TR capacity withcondenser fan motor of appropriate capacity - 01 No, air cooled condenser of 1.5TR capacity - 01 No,shall be installed out side the building.(c). Refrigerant copper pipe for suction & discharge linewith insulation, condensing water drain pipe& protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed.(d) Making good the disturbed surface to match the existing surface after plugging the hole etc . |
| 173 | Note :- (i).Cutting holes in walls/windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done.The unit rate quoted by contractor shall deemed to be inclusive of this aspect.(ii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer inclusive in above rate.(iii)copper piping/with insulations and drain piping shall also deemed to be inclusive in quoted unit rate. |
| 174 | Supply, installation, commissioning and testing of voltage stabilizer of following capacity, for automatic voltage correction of 20 volts per second, single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 220 volts + 2.5 % and High / low voltage cut off with facility of delayed start time of 3 minute complete all as specified and and directed :- |
| 175 | Capacity 3 KVA. |
| 176 | Capacity 1 KVA. |
| 177 | SCH \"A\"/ BOQ PART-XII (FIRE ALARM SYSTEM) |
| 178 | Supply, install, testing and commissiong of Fire alarm control panel complying with BSEN 54 single loop panel of capacity from 99 detector & 99 modules upto 200 detector and modules complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Siemens/ System Sensor. |
| 179 | S&F detector complying with and type certified to EN 45 addressable type, multisensor detector with heat and smoke combination, photoelectric/ optical with base complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Siemens/ System Sensor. |
| 180 | Supply, install, commissioning andtesting of addressable sounder complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Safeway. |
| 181 | Supply, install, commissioning andtesting of addressable type mannual call point resettable type complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Safeway. |
| 182 | M&L for fire alarm sounders / sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output variation of + 5db for 1000m range complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Siemens/ System Sensor. |
| 183 | S&F beam master detector, transceive type including power supply unit and module complete all as directed and specified. Make : AGNI/ Surekha/ Apollo/ Safeway. |
| 184 | S&F including laying and testing of PVC insulated, PVC sheathed stranded copper conductor cable of size 1.5 Sqmm 4core, galvanised steel steel strip or wire armourd, electric control cable (heavy duty) complete all as directed and specified. |
| 185 | SCH \"A\"/ BOQ PART-XIII (MISC)- EOT CRANE 20T |
| 186 | Design, supply, install, testing and commission of indoor type class M7 duty electrically operated, overhead travelling (EOT) crane of capacity 20 Ton, double girder type, suitably design for the proposed building/ structure duly confirming the following specification complete all as specified and directed :-(a) Cross travel (CT) span - 8mtr(b) Long travel (LT) span- 15.3 mtr(c) Clear Hook high- 6 mrt from FFl(d) Speed (M/min) (i) Cross travel- 15 M/min (ii) Long travel- 25 M/min (iii) Main hoist - 03 M/min(e) Control system - The control panels shall be provided with VWF controls.(f) Mehtod of operation - The crane shall be operated by pendant from flor level with provision for two speed micro and main speed.(g) Load Indicator - LED display load indicator with load pin type load cell with provision for indicator of load, alarm and shut down of Crane in case of load greater than 10% of rated load.(h) Audio & Visual indicators - Siren with audio and visual facility shall be provided to provide indication white crane is in operation. |
| 187 | NOTE:-(i) The scope includes long travel beam along with rail, box type double girder with rail shouded bus bar, all safety provision with limit switch, EHT Breakers and any accessories as recommended by OEM.(ii) The contractor shall submit design data, drawings, detailed specification of the crane and shall be get approved by the Accepting Officer. |
| 188 | S&F 3HP electric motor 3 Phase, 440volts, 50Hz, with gear box, chain & sprocket for opening & closing (forward & reverse motion) of rolling shutter with suitable starter panel with facility for forward & reverse operation of motor, including door limit switches, LT copper cables from starter panel to motor complete all as specified and directed. |
| 189 | S&F roof mounted turbo ventilation 600 mm sweep including metal base plate with SS variable duct suitable for roof mounting complete all as specified and directed. |
| 190 | M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earthstrip of size 32x6 mm as earthing lead by means ofbolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009)withconected to eath test point including adequate quantity of charcoal dustand comman salt, PCC (1:3:6) type C-1chamber andfor earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both wayswith MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for wateringand 40mm dia medium grade GI pipe as earth lead protection pipe completeall as specified and directed.Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor. |
| 191 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. |
| 192 | Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 193 | M&L for road cutting of size n\"exc 20cm width and n\"exc 90cm depth for laying of cable including making good the road with and including PCC (1:3:6) type C2 complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy