| 1 | Demolition of cement concrete (unreinforced) of any description in ground floor not otherwise specifically provided for complete all as specified and directed. |
| 2 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 3 | M&L Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6built in cement mortar of any description complete all as specified and as directed. |
| 4 | M&L Providing, cement concrete type B0 1:2:4 (12.5mm graded) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed all as specified and directed. |
| 5 | M&L 10 mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete etc finished even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L Preparation of new plastered surfaces and applying three coats of white wash on walls complete all as specified and directed. |
| 7 | M&L hard core broken stone of guage n exc 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 8 | M & L for 40 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone agg) as in Hard standing etc.with , spike rolling ,or making impression of expanded metal, while the concrete is green includingcomplete all as specified and directed. |
| 9 | M&L in 300mmx300mmx25mm thick pre-polished cement concrete chequered tile jointed in neat cement slurry and pointed in white or coloured cement to match the floor, complete, all as specified and directed. |
| 10 | M&L for screedbed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 11 | M&L 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base floor, complete all as specified and directed |
| 12 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade over sand cushion with grey cement and no pigment incl removal of old and necessary demolition complete all as specified and directed. |
| 13 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and including side kerb concrete, incl removal of old and necessary demolition complete all as specified and directed. |
| 14 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 15 | M&L for Stone kerb of roughly squared stones of size 15cm x 30cm, dressed so that the maximum depression from a straight edge held againstthe dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush and all as specified and directed. |
| 16 | Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, over sand cushion with grey cement and no pigment and including side kerb concrete, including removal and refixing complete all as specified and directed . |
| 17 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil complete all as specified and directed. |
| 18 | Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as specified and directed. |
| 19 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 20 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness will be considered for paymet. |
| 21 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed . |
| 22 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material to out side MD land.(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 23 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 24 | Material and labour in repair for 3.5 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 25 | Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 26 | Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. |
| 27 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 28 | M&L as in repairenergy efficient flood lightLED type 200watts, IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD complete all as specified and as directed. Make - Philips /Bajaj/Havells/CG |
| 29 | Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bent to shape as directed, fixed on poles with necessaryclamp of required size suitable for steel tubular pole including suitableGInuts and bolts washers complete all as specified and as directed . |
| 30 | Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:-(i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 luxand for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS.(ii)Surge protection device (SPD) should provide protection against indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity.(iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 typeB1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete.The scope of work also comprising the following :-The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller\"s preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use,Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :- |
| 31 | (a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells)(b)Supply Resign cast CT\"S - set of 3(c)GSM based smart street light controller.(d) Lux based sensor to operate external as per light intensity.(e)Line Contactor, AC 3duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells)(f)MCB SP 32 Amps- 06 Nos(make -L & T, BCH, Havells)(g)Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination.(h) GSM/Timer/Bypass Mode switch.(j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. |
| 32 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 16 A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 33 | M&L as in repairenergy efficient street light luminaire LED type 45watts IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD complete all as specified and as directed. Make - Philips /Bajaj/Havells/CG |
| 34 | Supply and Fixing GI tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 35 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 36 | Material and labour in repair for 4 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 37 | M&L for Octagonal GI poles complete with GI base plate finial taper plug, bolts, nuts and screws,with suitable bracketall as specifiedof height 7 M including necessaryEarth work,PCC foundation copping etc and refixing of all existing fitting fixture from existing in old electric pole complete all as specified and as directed Make - Philips /Bajaj/Havells/CG |
| 38 | M&L RCC M25 (using 20mm graded stone aggregate) for foundations, including rafts,footings,foundation beams; plinth beams; bases for columns, lintel beams etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 39 | M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip with deep quality confirming to FE 500/FE 500D complete all as specified and directed. |
| 40 | M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concreteall as specified and directed |
| 41 | M&L providing 3 core PVC insulated FRLS copper wire of 1.5 Sqmm multistrandedfrom MCB to light fittings complete all as specified and as directed. |
| 42 | M&L as in repairenergy efficient street light luminaire LED type 70watts IP66, 230volts, 50 Hz, in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD complete all as specified and as directed.Make - Philips /Bajaj/Havells/CG |
| 43 | M&L as in repairenergy efficient flood lightLED type 100watts, IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD complete all as specified and as directed. Make - Philips /Bajaj/Havells/CG |
| 44 | M&L as in repairenergy efficient street light luminaire LED type 35/36watts, IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housingand cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KVSPD complete all as specified and as directed. Make - Philips /Bajaj/Havells/CG |
| 45 | Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panel,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with theromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular encloser should be minimum 200mm for air circulation & to minimize temp rise. Panel shallbe fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 100 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- |
| 46 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 40 Amp, 16 KA- 01 No (Incomer). (b) Change over switch 63 Amp, 4P front operated-01 No(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 32 Amp, 10 KA- 02 Nos(O/G).(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set(f) Space for spare feeder - 01 No. Note :-(i) The contractor shall submit CPRI approved IP65 certificate and other technical details of polycarbonate modular enclosure as mentioned in BOQ alongwith the make approval.(ii)The Contractor shall submit the drawing for approval of GE before executing the work.(iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 47 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. |
| 48 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 49 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 50 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 51 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 52 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 53 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 54 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 55 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 56 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 57 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 58 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 59 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 60 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 61 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 62 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 63 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 64 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 65 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 66 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 67 | Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed. |
| 68 | S&Fin repair Earth continuity conductor or main earthing lead by providing 20 x 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.NOTE : All Joints should be joined by Exothermic Welding or Brazing. |
| 69 | Note :- An amount of Rs 37,053.50 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |