| 1 | S & F in replacement Pressure die cast aluminum alloy housingLED street light fitting90Wattcomprises of pressure die cast Aluminium housing & having system efficiency 110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. |
| 2 | S&F in replacement Nature Switch street light controller three phase 5 KW of automatic street light switch using infrared sensor based NATURAL SWITCH for automatic switching of street lights, required illuminance for switching on is ≤30 Lux and for switching off ≥10 Lux also having part night operation 4 to12 hour with contactors and outgoing and incoming MCBs connected with min 10sqmm FLRS multistranded circuit all these must be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof and termite proof conforming to IP54 complete all as specified and directed by engineer in charge. |
| 3 | Material and labour for painting to existing LT steel tubular poles of sizes 9 mtr including bracket and other accessories as per site requitrement after preparing/ scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint and upto 1.5 mtr height from pedestral in 30 cm height in black and white paints complete all as per site requirement complete all as specified as directed. |
| 4 | Material and labour for painting to existing steel tubular poles of sizes 11 mtr in MRS after preparing/ scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint complete all as per site requirement complete all as specified as directed. |
| 5 | S and F in replacement polycarbonate junction loop in / loop out box of internal size 250 x 200 x 100 mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.Make :- HENSEL / SINTEX / HANSU of model HB 14. |
| 6 | S&F in replacement service bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.5 mtrlong (approx) bend to shape 115 degree and fix to pole for fixing of street light fitting on pole/wall etcfixed with 2 Nos 32x 6 mm GI clamp, Nut,bolts,washer etc complete all as specified and directed. |
| 7 | Supply and fix in replacement 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduitfor street light pole including connection from kiosk box to street light fittings complete all as specified and directed. |
| 8 | Supply, install and testAll in One Integrated Solar LED Street light ≥ 24.7 watt withIP-65 protection,compact design including pole mounting bracket & nut , bolts clamp etc for fixing of bracket , microwave based motion sensor for optimising battery autonomy with factory setting dimming profile along with microwave sensor for run time maximization, suitable for 2 Nights Autonomy/Backup, all as specified and directed by Engr-in-Charge. ALL IN ONE INTEGRTATEDSOLAR LIGHT: Solar Panels with Lithium Ferro phosphate battery and charger built into the luminaire. Cat Part No. BRC 010 LED 40/765, Make ofPhilips or equivalent of Havells/Bajaj/Crompton |
| 9 | Supply & Fix LED flood light ftg 150 Watts , Incl Driver unit assy with surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. |
| 10 | Taking down Street lights, Hight mast light fitted on poles/buildings at height up to 10-20 mtr from ground level and repairing the same and refixing with proper connections complete all as per the instruction of JE E&M / Engineer in Charge.Note: - (i) Cost of spares and accessories will be measured and paid seperately under relevent items. (ii) Cost for soldering of panel shall be deemed to be included in the unit rate quoted. |
| 11 | Supply only LED driver unit suitable for 60 watt LED Fitting complete all as specified and directed at site. |
| 12 | Supply onlyLED driver unit suitable for 90 watt LED Fitting complete all as specified and directed at site. |
| 13 | Supplyonly LED driver unit suitable for 120/150 watt LED Fitting complete all as specified and directed at site. |
| 14 | Supply & Fixing in replacement LED post top lamps of capacity 25 W used for gate light IP 65 spun aluminium landcape luminiare opal cover all as specifird and directed by Engr-in-Charge. |
| 15 | M&L in replacement of XLPE 4 core 25 sqmm insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall all as directed by Engineer-in-Charge.Note: (i) Rateinclude the cost of lugs of proper size andcable gland(ii) Necessary Excavation,PCC coverand sand cushioning shall be measurd & paid seprately. |
| 16 | Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etcall as specified and directed at site. |
| 17 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed. |
| 18 | Supply and providing sand cushioning with dry clean sand 8 cm below cable and 15 cm above the cable including punning to 18 cm total thickness complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 19 | Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
| 20 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 21 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 22 | Taking down/dismantling LT PCC poles and deposit to MES store complete all as specified and directed at site by Engr-in-charge. |
| 23 | Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts and screw as specified, type 410 SP-31, 9.0 Metre long including painting all external exposed steel surfaces with two coats of aluminium paint over a coat of red oxide zinc chrome primer and all internal surfaces & external surfaces in contract with concrete with two coats of black bituminous paint and painting of bottom portion of the pole upto 0.75m from top of the coping with two coat of synthetic enamel paint over a coat of red oxide primer and writing pole no with synthetic enamel white paint on black colour circle of suitable size complete all as specified and directed.(Note: Excavation & Earth work andPCCfoundation/baseshall be measured and paid seperately ). |
| 24 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 25 | Excavation in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge |
| 26 | Demolition of cement concrete in ground floor and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as directed.. |
| 27 | M&L for PCC(1:2:4) type B1 using 20 mm graded stone aggaregate in kerbs/coping /bed plates and like including weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 28 | M&L for PCC(1:4:8) type D2 using 40 mm graded stone aggregates in foundation, mass concrete and fillingincluding weathering slightly rounded or chamfered completewith necessary use and waste fo formwork complete all as specified and directed at site. |
| 29 | Material and labour for cutting out the burnt out existing cable from outgoing of distribution transformer/ Incoming cable to LT panel/ Outgoing cable from LT panel and reconnecting by providing new lugs,tapes etc for cable of any size complete all as specified and directed .Note - Excavation work for use to loop of existing cable shall be includes in quoted rates. |
| 30 | S&F in replacementof Retro Sign board with MS structure, 3 mm thick Aluminium composite panel (ACP) retro print double sided in square shape of size 3 feet x 3 feet framing made with MS frame with MS square pipe leg for mounting of Board to be provide in height of 1.5 mtr and grouted in PCC complete all as specification Note- (i) Provide name, History of E/M instalation as per approval by AGE and cost to be included in qouted rates. (ii) Earth and PCC work is deemed to be included in the rate quoted. |
| 31 | M&L for Earthing complete with Copper Earth Plate Electrode 600x600x3.15mm thick burieddirectlyin ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connectedto Copper Earth Strip 20x3mm and drawn through andincluding Galvanised Iron Protection Pipe40mmbore (dia) ‘light grade’ upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Copper or Bronze Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of char coal or coke dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded aggre gate) reinforced with and including 8mm dia TMT Bars @10 Cm centre to centre both ways and suitable handle of 10 mm dia round bar, GI Wire Mesh, Funnel with GI Watering Pipe 20 mm bore (dia) ‘medium grade’, necessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion complete all as specified and as directedNote :(i) 7.5 RM Copper earth strip deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than permissible limiton testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate. |
| 32 | Supply and installationtesting andand commissioning outdoor LT panel totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply,fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel for, protection ofenclosure IP-54 as per IS standards complete with pretreatmentand powder coating of approvedcolour including suitable angle 50mm x 50mm x 6mmiron/flat iron frame work/supports, hinged door , front and rear opening and locking arrangements, cable gland and lugs for incoming and outgoing cables, necessary excavation and earth work PCC foundation etc deemed to be inclided in quoted rate, switchgear fitted and connected internally complete with bus bar as per capacity of switchgear all as directed and specified by Engr-in-charge including taking down old panel and following:- (a)4 Nos verticle copper bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves contiuous rating 100 Amps with provision to connect the outgoing cable.(b) LED type indicating lamp for R,Y,B phases at incoming side. Digital Ammeter with suitable CT for RYB phases and build in selector switch -01 Nos. Digital voltmeter for RYB phases protected through 1 Amps fuse with selector switch 01 Nos. All wiringto be completed bt 2.5 sqmm pvc wire multistranded single core wire.(c) MCCBTPN, 415 volt fixed type, 40 Amps, adjustable overload and short curcuit with breaking capacity 36 KA- 01 No (Incoming )(Make: L&T/Schnieder/siemens)(d) MCCBTPN, 415 volt fixed type, 25 Amps adjustable overload and short curcuit with breaking capacity 36 KA- 02 No (Outgoing)(Make: L&T/Schnieder/siemens)(e) MCCBTPN, 415 volt fixed type, 16 Amps adjustable overload and short curcuit with breaking capacity 25 KA- 02 No (Outgoing)(Make: L&T/Schnieder/siemens)(f) Panel inbuild on load Change over switch of capccity 63A 4 Pole connection of main line and generator line should terminate and outgoing of change over to Main incoming MCCB though 100 A bus bar. |
| 33 | M &L for GI Earthing complete with GIearth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of depth not less than 0.90x 0.60 x 2.25 mtr below ground level with top edge ofthe plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earthstripof size 25x4 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers,testing of completion (drawn in earth lead protection pipe light gade GI of size 32/40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSRPart - I connected to earthing lead with Main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG ,including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EICNote :(i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately.(ii) Earth resistance of earth pit should be not more than permissible limit on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm top of GI Plate. |
| 34 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |