| 1 | Cleaning of existing sewage line 150 mm internal dia at any depth incl manholes by removing the manholes covers of any type/ size and cleaning by means of hydraulic jet pressure machine/ manually bamboo rodding as required at site from manholes and well flushing with water after cleaning incl getting out sludge if any and liquid materials from connecting manholes depositedin sewer line and removing the solids and sludge to atdistancenot exceeding 250m and covering the same with the soil obtained from excavation of pit including excavation and earth work and reinstating the manhole covers in its original position and as directed by Engr - in - Charge. Note:-Cleaning of existing sewage pipe line / manholes by suitable suction pump loaded vehicle / trailers / manually by bamboo rodding available in the market and depose effluent out side the defence land shall be included in the quoted rate. |
| 2 | All as per item no 1 here in beforebut 200 mm bore pipe. |
| 3 | Cleaning the blockage of bathroom/kitchen by cleaning the nahani traps / gully traps of all the mud / sludge and getting out washing throughly traps, CI waste pipe by opening the cleaning eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 250m from the gully trap and covering the same with the soil obtained from excavation of pit including excavation and earth work complete all as specified and directed.. |
| 4 | Cleaning the blockage of WC indian or European type by removing of all the mud / sludge and getting out including cleaning of SGSW or CI pipe upto first manholes and depositing the sludge in a pit of suitable size at a distance not exceeding 250m from the WC and covering the same with the soil obtained from excavation of pit including excavation and earth work complete all as specified and directed. |
| 5 | Removing the manhole covers (CI or RCC) any type or shape and desludging / dewatering of septic tank,Manhole and soakage well of upto 1.5mtr depthby mechanical pumping/ manually by plugging inlet as required, making it fully functional to the entire satisfaction of Engr -in- charge including carrying the effluent and reinstating the manholes cover to its original position complete all as specified and directed.Note:- Cleaning of septic tank/ soakage wells/ manholes by suitable suction pump loaded vehicle / trailers available in the market and dispose effluent out side the defence landshall be included in the quoted rates. |
| 6 | Cleaning and desludging of existing septic tanks / sump well/ deep manholes exc 1.5 mtr and n exc 3mtr deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment including removal of sludge and other foreign materials out side the MD land by any means complete (working in foul condition) all as specified & directed by Engr-In-Charge.Note:- (i) Ser item No67 to 70 for Cleaning Minimum 04 Nos ofLabours with one site supervisor for collection and disposal of complaintstill contract period shall be included in the quoted rates.(ii) For Ser item No 5 to 6, excavation and earth work deemed to be included in unit rate. |
| 7 | Exavation over area not exc1.5mtr deep and getting out in soft/loose soil completed as all at site. |
| 8 | Ditto-as per item no-7 above but exceeding 1.5 mtr but n.exc 3.00 mtr deep -dito- |
| 9 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil etc. including trimming bottom and sides of trenches, leveling/ grading and ramming bottom of excavation complete all as specified and directed. |
| 10 | Excavation in trenches n exceeding 1.5 m wide andexceeding 1.5 m in depth but not exceeding 3.mtr depth and getting out in soft/loose soil etc. including trimming bottom and sides of trenches, leveling/ grading and ramming bottom of excavation complete all as specified and directed. |
| 11 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as directed. |
| 12 | Removing surplus excavated soil to a distance n.exc 50 meter and depositing where directed at leveln.exc 1.50 m above the starting point. All as directed |
| 13 | Demolition and breaking up 150mm dia drain pipes (saltglazed, stoneware , AC or reinforced concrete) drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as directed. |
| 14 | S&F ultra plus PE, DWC ( Double Wall corrugated ) pipes confirming IS-16098 Part - 2 : 2013 pertaining structuredwall plastics pining system for Non - pressure drainage and sewerage 150 mm bore pipe and fittings with non smooth surface, type B complete all as specified and directed. |
| 15 | M&L for concrete bed for 150 mm bore pipe in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 16 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories |
| 17 | S&F 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls excludingclamps fixed to wall properly. Complete all as specified & directed |
| 18 | S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof. Complete all as specified & directed |
| 19 | S&F for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors or wall complete all as specified & directed. |
| 20 | S&F PVC (SWR) bend any radius 110mm dia |
| 21 | S&F PVC (SWR) bend any radius 75mm dia |
| 22 | S&F PVC(SWR) Tee any radius 110mm dia |
| 23 | S&F PVC(SWR) Vent cowl 110mm dia |
| 24 | S&F 110mm dia Branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as directed. |
| 25 | Demolition of old decayed / damaged brick work in cement or cement lime mortar and in any condition including removal of samecomplete all as directed. |
| 26 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 mtr mean radius and built in CM 1:4 complete all as specified and directed. |
| 27 | M&L for brick work using sub class B brick curved or straight on plan to any radius in half brick wall builit in CM(1:4)complete all as specified and as directed by Engr-in-Charge. |
| 28 | Demolition of cement concrete(unreinforced)in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as directed |
| 29 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for such as cover slab of manholes and septic tank, etc, reinforcement cut as required to facilite demolition complete all as directed |
| 30 | M&L for RCC (1:1.5:3) type A-1 using 20mm graded stone aggregate as in slabs supported on walls beams and columns etc complete all as specified and directed. |
| 31 | M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precastmanhole / septic tanks covers including necessary form work and setting in CM 1:4 complete all as specified and directed. |
| 32 | Use and waist form work to soffits of suspended slabs such as roof slabs, floor slabs n.exc.200mm thick in rough finished surfaces etc. |
| 33 | Use & waste of form work to rough finished surfaces of concrete as in foundations, footings, beams, columns, shelves, chajja etc complete all as spd and directed |
| 34 | M&L for mild steel TMT bars 6-8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed. |
| 35 | Taking down cement or cement lime plaster of any descriptionon brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as directed. |
| 36 | M&L for rendering 15 mm thick in CM 1:4 on any faces brick work including finishing the surface fair and smooth without using extra cementcomplete all as specified and directed. |
| 37 | M&L for providing PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping of manholes and similar work complete all as specified and directed. |
| 38 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, mass concrete etc complete all as specified and directed. |
| 39 | M&L for PCC 1:2:4 type B-2(using 40 mm graded stone aggregate) as in channels benching of manhole, laid to shape and slope, including necessary form work etc complete all as specified and directed. |
| 40 | Cutting into exisiting manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed. |
| 41 | M&L for brick work with sub class \"B\" bricks in one brick thick honey com walling built in CM (1:4) complete all as specified & directed. |
| 42 | M&L for Filling of brick bats in soak well laid dry complete all as specified and directed. |
| 43 | Supply only integral water proofing compound.ISI Marked |
| 44 | M&L for Preparation of newly plastered surface of walls,and applying two coats of cement base paint over a coat of primer to external surfaces of walls complete all as directed |
| 45 | M&L for preparation of old decorated surface of walls rubbing,watering etc and applying one coat of cement base paint complete all as specified anddirected. |
| 46 | Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground/portion, post embedded in natural ground etc complete all as specified and as directed. |
| 47 | Excavatinginpost holes (or similar holes) in soft/loose soil each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface. complete all as directed. |
| 48 | Material and labour for 100mm thick PCC 1:4:8 Type C2 (40mm graded stone aggregate) as in hardstanding/Path/Paving, surface is to be finished even and fair without using extra cement complete all as specified and directed |
| 49 | Dismantling floor hearth or wall tiling, interlocking paver block/cheuered cement concrete tiles including cement mortar bedding ( but not backing) removing serviceable tiles and rubbish off the premises. Complete all as specified & directed |
| 50 | M&L for coloured cheuered cement concrete tiles 20cmx20cmx25mm thick with gray cement and pigment, set,jointed and pointed in neat cement slurry in floors including 15mm thick screedbed in CM 1:6 all as specified and directed |
| 51 | M&L for pressed precast concrete interlocking paver block any shape and size confirming toIS 15658-2006 of 60mm thick M-35 grade with gray cement and pigment complete all as specified and directed |
| 52 | M&L for sand filling under floors or in foundations including watering and consolidation. Complete all as directed |
| 53 | Material and labour for providing plain cement concrete 1:2:4 type B-1(20mm graded crushed stone aggregate) set in CM 1:4, as in copings, includingnecessary form work complete all as specified and as directed |
| 54 | M/L hard core gauge n.exc 63 mm deposited spread & levelled in layars n exc 15 cm thick watered & rammed in a true surface using broken stone or boulder . |
| 55 | M&L for PCC Type B-2 (1:2:4) using 40 mm graded stone aggregate in foundation filling and packing of fencing post or other works complete all as specified & directed |
| 56 | S&F Mild steel work as inhand rails, half round or other stock section or core for woodenhand-rail straight portion, drilled and countersunk forbalusters running bars for doors, balusters, nosing to steps including embeding in concrete and screws etc wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron filets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 57 | M&L for preparation of new steel surfaces of any description over 10 cms in width or girth not otherwise described and apply two coat of synthetic enameled paint over a coat of red oxide zinc chrome primer as specified & directed |
| 58 | Supplied and fixed in repair galvanized 2 strands steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standared rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire , staples or steel pins etc as directed(each line wire to be measured). complete all as specified & directed. |
| 59 | S & F 5 to 10 mm dia mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm but n. exc. 10 cm long complete. all as specified & directed |
| 60 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but n.exc 10 cm long dia of neck in mm 11 mm to 15 mm.complete. all as specified & directed |
| 61 | S&F Chimney bars (straight or camber) : bearing bars; tongues or water bars for window frames, window guard bars, bars for chain link fencingplain, let in and fixed independently in wooden frames, L or T section supports for shelves etc and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 62 | Dismantling fencing wire mesh, any type or in any situation complete all as directed |
| 63 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified. |
| 64 | Supply only chain weight of chain link fencing shall be mesured through B.O.O) link MS galvanised fencing, any size or type as directed by Engr-In-Charge. |
| 65 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |