| 1 | Surface dressing not exceeding 15cm deep in soft/ loose soilincluding cutting of grass, roots, bushes if any and removing from site all grass, roots and extra soil if any complete all as specified and as directed. |
| 2 | Excavation in trenches (Manual), not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations of shafts, wells, cess pits, manholes, pipe line, cable in trenches etc., not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 3 | Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed. |
| 4 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 5 | Labour for earth filling, spreading and levelling in layers n exc. 25 cm thick (each layer) consolidating the surface with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge including levelling, well ramming and watering as required and consolidation complete all as specified and as directed. Note :- Earth obtained from excavation shall be re used and nothing extra on account of lead shall be paid. |
| 6 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed |
| 7 | Material and labour for PCC ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed |
| 8 | Material and labour for for hardcore of broken brick bats gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface complete all as specified. |
| 9 | Material and labour for 125mm thickcement concrete ( 1:3:6),type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 10 | Material & Labour for 40 mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4), type B-0, (using 12mm graded stone aggregate), including supply and mixing of liquid WPC in mortar @ 200 gm per bag of cement of 50kg, including Polythene film, 50 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm, complete all as specified and as directed. |
| 11 | Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement including 10mm wide, 30mm deep joints at the rate of 2.00 mtr centre to centre and at every turning point, filling the Joints withbituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and as directed |
| 12 | Material and labour for rendering/plastering 15 mm thick in CM (1:4) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 13 | Material and labour for rendering/plastering 15 mm thick in CM (1:6) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 14 | Material and labour for Washed stone grit plaster (rough cast plaster ) on exterior walls in two layers, under layer 10mm cement plaster (1:4) (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster (1:1/2:2) (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern, complete as specified and as directed. Note :- (i)The shade of grit finish should be different colour of aggregate as required and approved by GE. |
| 15 | Material and labour for preparation of new plastered surfaces, surface after complete removal, applying acrylic putty on internal surfaces of walls/ceiling/soffits etc (thickness vary from 1.5 to 2 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using readymade putty, including sanding with wall sander after filling the putty in first coat/second coat to make surface smooth and ready for receiving interior painting complete all as specified and as directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.Make of acrylic Putty: - Berger / Asian / Nerolac |
| 16 | Material and labour for applying 02 coats of exterior acrylic emulsion paint of approved tint/shade (CompanyDepot Tinted) @ 6 sq.m/litre/2 coats to external walls / Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. (on new or old prepared external surface after complete removal) over and including a coat of exterior primer @ 11 sq.m/litre/1 coat (primer shall be same make as acrylic emulsion paint), paint and primer applying by using airless spray gun complete all as specified and as directed.Brand and Make of exterior acrylic emulsion paint: - Weather Coat Glow of Berger / Apex Weatherproof of Asian / Excel of Nerolac Brand and Make of interior primer: - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac |
| 17 | Material and labour for mild steel Framed work such as in doors or gates, made by using rolled mild steel angle, or tee sections, or other section with gusset plates, rails, braces, round bars etc., complete, cut to shape, bending and welding, riveting etc, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including fabrication as directed, including hold fast, locking arrangement, sliding door bolt, stopper etc conforming to Fe-410-W (Gde E-250) quality A, complete all as specified and as directed. |
| 18 | Material and labourfor Mild steel, 1.25mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as requiredcomplete all as specified and as directed. |
| 19 | Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed including fixing material in any situation complete all as specified and as directed. |
| 20 | Material and labour for structural steel work, framed work made by using rolled mild steel Joist, channel, angle, or tee sections, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails, fixed independently distance pieces, cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, and cut to shape, drilled and counter sunk for screw, conforming to Gde Fe-410-W (Gde E-250 quality A)complete all as specified and as directed. |
| 21 | Material and labour for preparation ofnew steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st quality) of approved tint/colour over a coat of red oxide primer with using paint brush complete all as specified and as directed |
| 22 | Taking down carefully existing point wiring (light/fan/sockets/bell/power point) any type complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed. |
| 23 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincludingmedium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 24 | All as per above point wiring item but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ). |
| 25 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincludingmedium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 20 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 26 | Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch on independent board (using red, black and green etc colour wires as per colour coding i.e for phase, neutral, earth wire) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked) including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. drawn through andincludingmedium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, junction boxes, pipe hook/clips/clip clamps etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (min 60mm deep, suitable length and made from 1.6-1.63mm thick sheet) including inner and outer plate, outer cover plate white colour, any module as per requirements suitable for fixing the modular switch/ socket / regulator etc, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.Note :- (i) Modular switch, socket shall be measured and paid separately under appropriate item of BOQ. |
| 27 | Supply and fixing modular switch 6Amps, single pole, one way, 1 module complete all as specified and as directed. |
| 28 | Supply and fixing modular switch 16Amps, single pole, one way, 1 module complete all as specified and as directed. |
| 29 | Supply and fixing modular Socket outlet multipurpose type 6 Amp, 2 module complete all as specified and as directed. |
| 30 | Supply and fixing modular Socket outlet multipurpose type 16 Amp, 2 module complete all as specified and as directed. |
| 31 | Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, topline series, 240 volts, 6 Amp, complete all as specified and as directed. |
| 32 | Supply and fixing modular stepped type (1-4/5), electronic Fan regulator, 100-120 watt,250 volts, (2 module) suitable for any type of fan except BLDC fan complete all as specified and as directed. |
| 33 | Taking down existing LED tubelightof any size complete all as specified and as directed. |
| 34 | Supply and fixing LED tube light fitting polycarbonate housing 1 x 20/22Watt, appx 4 feet long, housing environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 35 | Material and labour for Cutting openings, through brick walls built in cement mortar at any floor for exhaust fan of300/380mm sweep including making good with cement mortar (1:4) complete all as specified and directed. |
| 36 | Supply and fixing exhaust fan (heavy duty, minimum 3 star rating) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame, and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long, including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds and fixing for covering to opening in wall as directed, making electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable drawn in flexible PVC conduit,and making good the disturbed surface complete all as specified and as directed.Note :- (i) Serial Number as issued by Engr-In-Charge shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 37 | Supply and fixing exhaust fan (heavy duty, minimum 3 star rating) steel body, AC single Phase 230V, 50Hz, 900RPM, size 380/400mm sweep with blades and frame, and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long, including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds and fixing for covering to opening in wall as directed, making electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable drawn in flexible PVC conduit,and making good the disturbed surface complete all as specified and as directed.Note :- (i) Serial Number as issued by Engr-In-Charge shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |