| 1 | Demolition of cement concrete (unreinforced) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed. |
| 3 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 5 | Removing excavated material (soils) exceeding 1500 m but not exceeding 5000 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 6 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 300 mm, set in cement mortar complete all as specified and as directed. |
| 7 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 150 mm, set in cement mortar complete all as specified and as directed. |
| 8 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 200 mm, set in cement mortar complete all as specified and as directed. |
| 9 | M & L for concrete bed to glazed stoneware pipes of internal diameter 300 mm, class SP1, laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and completely surrounding or encasing pipes with concrete complete all as specified and as directed. |
| 10 | M & L for concrete bed to glazed stoneware pipes of internal diameter 150 mm laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and completely surrounding or encasing pipes with concrete complete all as specified and as directed. |
| 11 | M & L for concrete bed to glazed stoneware pipes of internal diameter 200 mm, laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and completely surrounding or encasing pipes with concrete complete all as specified and as directed. |
| 12 | Supplying and laying reinforced concrete pipes with collars, 300 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. |
| 13 | Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. |
| 14 | Supplying and laying reinforced concrete pipes with collars, 200 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. |
| 15 | M & L for glazed stoneware square mouth gully trap, P type, size 150 X 100 including setting and jointing to drain with cement mortar 1:1 complete all as specified and as directed. |
| 16 | M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 17 | Material and labour for plastering 15 mm thick on other than fair faces of brick wall or stone surfaces in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed.Note: Water proofing compound shall be measured and paid for separately. |
| 18 | Supply only integral water proofing compound of approved make complete all as specified and directed. |
| 19 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed. |
| 20 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. |
| 21 | M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed. |
| 22 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. |
| 23 | M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 24 | Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 25 | Excavating over areas exceeding 1.5 m but not exceeding 3 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 26 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed. |
| 27 | Removing excavated material (soils) exceeding 250 m but not exceeding 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 28 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 29 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 30 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 31 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 32 | M & L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 33 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 34 | M & L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20 cm wide for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 35 | Cutting into existing manholes for connecting new drains of pipe of nominal size 300 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed. |
| 36 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 37 | M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 38 | Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 39 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 40 | M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. |
| 41 | Dismantling of cast iron, PVC pipe or reinforced concrete drain pipes of size 75mm /100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed. |
| 42 | S & F cast iron, sand cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 1729: 2002 in any length with cement joints & including fittings of suitable size, laid in trenches or in floors complete all as specified and as directed. |
| 43 | S & F cast iron, sand cast, socket and spigot, nominal dia 75 mm soil, waste and vent pipe as per IS 1729: 2002 in any length with cement joints & including fittings of suitable size, laid in trenches or in floors complete all as specified and as directed. |