| 1 | Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in soft / loose soil and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in Hard / dense soil and getting out in Hard / dense soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated meterial to a distance n.exc50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Water testing for physical, chemical, and biological parameters once in 3 months stating the quality of potable water from Govt recognized lab for supplied water as well as received water.The original test certificate is of every 03 month is deposited to office Engineer-In-Charge complete all as specified and directed.Note : (i) Water samples to be collected in presence in Engr-in-Charge.(ii) Sterlize containters to be brought by the contractor. |
| 6 | Taking up or taking down steel tubing and connections including cleaning for refixing or removal to store for the following sizes complete all as specified and directed :- |
| 7 | 15 mm dia |
| 8 | 20 mm dia |
| 9 | 25 mm dia |
| 10 | 40 mm dia |
| 11 | 50 mm dia |
| 12 | 80 mm dia |
| 13 | Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches complete all as specified and directed offollowing sizes :-. |
| 14 | 15 mm dia |
| 15 | 20 mm dia |
| 16 | 25 mm dia |
| 17 | 40 mm dia |
| 18 | 50 mm dia |
| 19 | 80 mm dia |
| 20 | Relaying only GI tubes any grade in trenchesmaterials obtained from Item No. 6 here-in-before after cleaning or rerunning the old screw threadswith replacement of unsv fittings and fixtures complete all as specified and directed of following sizes:- |
| 21 | 15 mm dia |
| 22 | 20 mm dia |
| 23 | 25 mm dia |
| 24 | 40 mm dia |
| 25 | 50 mm dia |
| 26 | 80 mm dia |
| 27 | Supply and Fixing for gun metal gate valve with following mm dia with iron wheel head screwed both ends ISI markedfixed to GI pipe including removal old unserviceable one complete all as specified and directed. |
| 28 | 15 mm dia. |
| 29 | 20 mm dia. |
| 30 | 25 mm dia. |
| 31 | 40 mm dia. |
| 32 | 50 mm dia. |
| 33 | 80 mm dia. |
| 34 | Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot or socket ends or flange ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified and directed of following sizes:- Note :Excavation and earth work shall be measured and paid separately. |
| 35 | 400 mm dia |
| 36 | 200 mm dia |
| 37 | 150 mm dia |
| 38 | 100 mm dia |
| 39 | Supply and Fixing MS Fittings for pipe line of CI/DI/ERW for breakdown in entire AOR of GE (MH &RH) Khadki area with necessary exacavation upto 1.5 mtr depth and on plan upto the 4 Sq meter whichever is required and after jointing the kit complete refilling and removal of the excavated soil complete all as specified and directed:-Note :- (i) Minor spare parts likerubber insertion gasket joints, nuts, bolts & washers of required size & Nos, cleaning the pipe surface,chamfering or cutting the edges of pipes for positioning, jointingand testingis included in quotaed rate. |
| 40 | Supply and Fixing Cast iron Sluice Valve with stainless steel spindle and cast iron hand wheel complying with IS:14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one of the following bore sizes complete all as specified and directed:- |
| 41 | 300 mm dia sluice valve |
| 42 | 200 mm dia sluice valve |
| 43 | 150 mm dia sluice valve |
| 44 | 100 mm dia sluice valve |
| 45 | 80 mm dia sluice valve |
| 46 | Supply and Fixing Cast iron Non Return Valve complying with IS:14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unserviceable one complete all as specified and directed of the following sizes:- |
| 47 | 200 mm dia |
| 48 | 150 mm dia |
| 49 | 100 mm dia |
| 50 | 80 mm dia |
| 51 | Taking down exsiting unserviciable and Supply and fix in repair temper proof air release valve cast iron body flanged type double acting type, ISI Markon existing places complete all as specified and directed of the following sizes:- Make : Swastik / Normax/ Kartar / Kirloskar |
| 52 | 150 MM Dia |
| 53 | 100 MM Dia |
| 54 | 80 MM Dia |
| 55 | Material and labour for making hole/ferrule for fixing in existing 300/400 CI/DI pipe line of air release valve of 100 mm dia along withnecessary 100 mm GI nipple and suitable legnth ofbarral peace with provision of one no 100 mm sluice valve of PN 1.6 complete all as specified and directed.NOTE : (i) Rates inclusive of T & P required for making hole to the existing DI/CI pipe of 200mm /300mm /400 mm dia.(ii) Rates inclusive of one 80 mm Air release valve and one no 80 mm sluice valve of PN 1.6. (iii) Rates inclusive of provision of one No. 80 mm barral piece of required length incusive of one no pack Tee(iv) Rates inclusive of no pach Tee of size 200mm/ 300mm / 400mm x100mm.(v) Rates inclusive of flange,suitble for 80 mm pipe, 80 mm GI socketand necessary welding works(vi) Rates inclusive of any earth work required at site. |
| 56 | Material and labour for repair the sluice valve of following size spindle and change the Stainless Steel spindle and its internal part socket complete all labour work and fixing back to its original postion and make sluice valve functional complete all as specified and directed. |
| 57 | 400 mm dia sluice valve |
| 58 | 300 mm dia sluice valve |
| 59 | 200 mm dia sluice valve |
| 60 | 150 mm dia sluice valve |
| 61 | 100 mm dia sluice valve |
| 62 | 80 mm dia sluice valve |
| 63 | Supply and Fixing following Mechanical Joint for pipe line of CI/DI/ERW for breakdown in entire under AOR of GE (MH & RH) Khadki with necessary exacavation upto 1.5 mtr depth and on plan upto the 4 Sq meter whichever is required and after jointing the kit complete refilling and removal of the excavated soil complete all as specified and directed:-Note :- (i) Minor spare parts likerubber insertion gasket joints, nuts, bolts & washers of required size & Nos, cleaning the pipe surface,chamfering or cutting the edges of pipes for positioning, jointingand testingis included in quotaed rate.(ii) Necessary barrel piece if requried at site is deemed to be included in the quotated rates. |
| 64 | 400 mm dia |
| 65 | 300 mm dia |
| 66 | 200 mm dia |
| 67 | 150 mm dia |
| 68 | 100 mm dia |
| 69 | 80 mm dia |
| 70 | Supply and Fixing following JP Joint for pipe line of GI for breakdown in AOR of GE (MH & RH) Area with necessary exacavation upto 1.5 mtr depth and on plan upto the 4 Sq meter whichever is required and after jointing the kit complete refilling and removal of the excavated soil complete all as specified and directed:-Note :- (i) Minor spare parts likerubber insertion gasket joints, nuts, bolts & washers of required size & Nos, cleaning the pipe surface,chamfering or cutting the edges of pipes for positioning, jointingand testingis included in quotaed rate. |
| 71 | 100 mm dia |
| 72 | 80 mm dia |
| 73 | 50 mm dia |
| 74 | Material and Labour for construction of Brick Masonry Valve Pit, one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded stone aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40mm x 40mm x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded stone aggregate) Block of size 230mm x 200mm x 100 mm, applying two coats of Anti-corrosive Paint over and including a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit of following sizes complete all as specified and directed:- |
| 75 | 1000mm x 1000mmon plan and deep upto 1000 mm (Internal Dimension) |
| 76 | 900mm x 900mmon plan and deep upto 1000 mm (Internal Dimension) |
| 77 | 600mm x 600mmon plan and deep upto 750 mm (Internal Dimension) |
| 78 | Taking down unserviciable andMaterial and Labour for fabrication/structuralwork with mild steelsheet/ angleironin any shape or size as indicated or directed andincluding belding/ bracing, painting with one coat of red oxide primer and two coat of blackpaint (one coatbefore fixings and one coat of blackpaint after fixing) (Fe 290 Gde E-165) complete all as specified and directed. |
| 79 | Material and labour for PCC 1:3:6 ,Type C1, M-10, using 20 mm graded stone aggragate for foundations, filling and mass concrete complete all as specified and directed. |
| 80 | Material and Labour for repair of existing Brick Masonry Valve Chamber, with brick work with sub- class \"B\" brick in one brick thick wall in cement mortar 1:4including Rendering of Cement plaster 15 mm thick internally and externally with Cement motor 1:6complete all as specified and directed. |
| 81 | Material and labour in repair of mild steel plates (plain or chequered) of5mm thick or over in thickness in available sizes Fe-290 (Gde E-165) complete all as specified and directed. |
| 82 | Material and Labour in repairfor taking down of unserviceable Actuator of water supply automation system setup from valve and servicing it properly and replace the burnt out / unserviceable components if any of the setup and aligned the same for proper functioning and reinstall at it\"s initial position including testing proper complete all as specified and directed.Note:(i)Rates quoted shall be deemed to be included for fixing of the following new components underrespective item like protection relay, contactor, pin, nozzle, minor valves, gland, grease, nut bolts even major parts. (ii) Contractor should visit site before quoting the rates. (iii)Cost of transportation shall be deemed to be included in the rate quoted for these items. |
| 83 | Taking down unserviciable and Supply and Fixing in replacement Water pressure gauge of capacity 14 Kg/mm2 gauge 4\" (size of dial) complete all as specified and directed. (Make-ISI Make) |
| 84 | Taking down unserviciable and Supply and Fixing in replacement Water pressure gauge of capacity 14 Kg/mm2 gauge 8\" (size of dial) complete all as specified and directed. (Make-ISI Make) |
| 85 | Supply and Fixing in repairs following capacity triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and over flow etc complete all as specified and directed. |
| 86 | 500 Ltr |
| 87 | 1000 Ltr |
| 88 | 2000 Ltr |
| 89 | Supply and fix float valve suitable for following sizes / dia pipeline as required complete all as specified and directed. |
| 90 | 15mm |
| 91 | 20mm |
| 92 | 25mm |
| 93 | Disconnecting existing tanks of following capacity setting aside (or lowering if required) water tank, dewatering, cleaning and removeing all dirt, scale and algae formation from inside the tank by usingcleaning chemicals including paste stickers mentioning \"TANK CLEANED ON \" with date, month, & year. The stages of cleaning process of tanks are as follows :-(a) To drain out the water by using exist valve or high capacity dewatering system.(b)Cleaning all the algae formation inside the tank by using high-strength calcium hypochlorite (HSCH) chemicals and scrubbing the walls & base of the tank by scrubber.(c) Fresh water cleaning with high speed jet pump.(d)Drying the tank then first stage of bacteria screening and sterlization of the tank by using high-strength calcium hypochlorite (HSCH)chemical.(e)Cleaning the floor of the water tank by heavy duty industrial vaccum clearner.(f)Second stage of bacteria screening and starilization of the tank by using ultra violet ray ejector covering 360 degree within the tank and killing all suspended bactaria (g)Third stage of bacteria screening and sterilization of the tank floor by usinghigh-strength calcium hypochlorite (HSCH)chemical.Note - (i)The quoted rate shall include for removal of mud, grits and deposits etc properly from site of work and on completion of work sterlisation certificate to submitted to the Engineer-in-charge.(ii)Cleaning needs to be done mechanically by authorised dealer/agent as approved by Engr-in-charge.(iii)Cleaning chemical shall also be approved by Engineer-in-charge. |
| 94 | 500 Ltrs/ 1000 Ltrs |
| 95 | 2000 Ltrs |
| 96 | Labour only for attending the emergency repairs to leakage/damage GI/ CI/DI pipe of 300/400 mm dia either in night or in any holiday, running with in the of AOR of GE (MH & RH) Khadki including carrying out major repairs to the leakage/breakage etc as required to makethe system in order / functional and necessary excavation, returning, filling of soils and removal of waterby using pump, cutting and jointing with new fittings as required at site complete all as specified and directed.Note(i) Rate inclusive ofearth work by means of JCB machine.(ii) Jointing materials if required will be measured in kg under respective items in this schedue. |
| 97 | All as per Item No 30.00 for dia pipe 150 mm to 200 mm |
| 98 | All as per Item No 30.00 for dia pipe 50 mm to 100 mm |
| 99 | All as per Item No 30.00 for dia pipe 25 mm to 40 mm |
| 100 | All as per Item No 30.00 for dia pipe 15 mm to 20 mm |