| 1 | M&L for cleaning of existing sewage system / pipe line of dia upto 200mm at any depth located in different situations / sites, taking off the manhole cover and placing in the same original position after getting out liquid / sludge / solid contents from the manholes / sewage line and complete perfect function / running / flowing condition without any obstruction by removing all blockages in system using pressure jet cleaning technology & super succection machine only, making it fully functional to the entire satisfaction of Engineer-in-Charge including removing of all waste material out of CG land, complete all as specified and as directed by Enginee-in-Charge. (Rate for getting out of liquid, sludge/ other materials from manholes / lines and removal is included in unit quoted rate) |
| 2 | De-sludging from septic tanks and soakage wells of any capacity, size and depth including dewatering and disposal of sludge etc and taking off the manhole cover and placing in the same position after taking out sludge through mechanically sewage suction pump and safely store in covered container etc complete and removing the sludge in covered van/trolly outside the CG land all as specified and directed by Engineer-in-Charge. Note :-Only solid material will be measured for the purpose of payment. |
| 3 | Desilting/ de-sludging from manhole of depth upto 3m including dewatering, carriage of sludge from manhole mechanically and disposal outside CG land complete all as specified and directed by Engineer-In-Charge. |
| 4 | Cleaning of blockage of bathroom / kitchen by cleaning the Nahani traps / floor traps of all the mud / sludge and getting out, washing thoroughly grating of trap, waste pipes by opening the cleaning eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 50 metres from the gully trap and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as specified and directed by Engineer - in – Charge. |
| 5 | Cleaning of blockage of Water closet Indian or European type by removing of all the mud / sludge and getting out, including cleaning of pipe upto 1st manhole and depositing the sludge in a pit of suitable size at a distance not exceeding 50 metres from the gully trap and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as specified and directed by Engineer - in – Charge. |
| 6 | Cleaning of drain lines of cross sectional area upto 1 sqm by removing all the dust, particles, mud etc and getting out including opening of blockage of drain if required and removal of materials upto a distance not exceeding 50 metres from the drain complete all as specified and directed by Engineer - in – Charge. |
| 7 | Cleaning of gully trapsof size 125/110mm and removal of blockagecomplete all as specified and directed by Engineer-In-Charge. |
| 8 | Dimolition of precast cement concrete articles, brickwork or stone/ boulder masonry / PCC block masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stone work etc |
| 9 | M&L for pre-cast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete |
| 10 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 11 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 |
| 12 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for including removal of debris off the MD land. |
| 13 | M & Lfor precast concrete slab in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face using cement concrete1:2:4 type B-1 using 20 mmgraded aggregates set and jointed in CM 1:4 complete all as specified and directed by Engineer-in charge. |
| 14 | M&L for RCC (Nominal mix) type A-1(1:1.5:3) (20mm graded aggregate) as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like complete all as specified and as directed |
| 15 | M&L forFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping)complete all as specified and as directed. |
| 16 | M & L for CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in coping supported on wall, complete all as specified and as directed |
| 18 | M&L for demolition of cement concrete of any description and in anypositionnot otherwise specifically provided for (road cutting) including removal of rubbish out side CG land complete all as specified and as directed. |
| 19 | M&L for 100 mm thick PCC Type B2 1:2:4 (40mm graded aggregate) as in sub base/floors or filling in roadscomplete all as specified and as directed |
| 20 | M&L for DWC pipe of 150 mm dia complete laid in trenches and jointed including testing along with necessary jointing material tees/ union/ socket etc completeall as manufacturers instructions including taking out old pipe. |
| 21 | M & L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes of bore 150mm after they are laid and tested in cement concrete type C-2 (1:3:6) complete all as specified and directed. |
| 22 | Demolition and breaking up drain pipes (SGW , AC or reinforced concrete) set in cement mortar internal dia of pipe 300 mmcomplete all as specified and directed. |
| 23 | M&L for 300 mm dia reinforced concrete puipes, class NP2 laid in trenches and jointed including testing along with necessary jointing material coller etc complete all as specified and directed. |
| 24 | M & L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes of bore 300mm after they are laid and tested in cement concrete type D-2 (1:4:8) complete all as specified and directed. |
| 25 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan in soft /loose soil and getting out complete all as specified and directed. |
| 26 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft /loose soil complete all as specified and directed. |
| 27 | Removing excavated material (soils) n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 28 | M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation, filling and mass concrete, complete all as specified and directed by Engr-in-Charge. |
| 29 | Taking down eaves gutter and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan neck etc icluding cleaning or refixing or removal to sore complete all as specified and as directed.Note: Measured overall as fixed along the centre line over fitting and accesories for payment purpose. |
| 30 | S&F 100 mm dia PVC (SWR) waste and vent pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 31 | S&F 75 mm dia PVC (SWR) waste and vent pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 32 | S&F in repairs PVC (SWR) 75mm bore branch piece, single (Single \"Y\") equal orwith access door Complete all as specified and as directed by Engineer-In-Charge. |
| 33 | S&F in repairs PVC (SWR) bends of size 75 mm complete all as specified and as directed by Engineer-In-Charge. |
| 34 | S&F in repairs PVC (SWR) bends of size 110mm complete all as specified and as directed by Engineer-In-Charge. |
| 35 | S&F in repairs stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays for 110 mm dia bore pipe, including bolts and nuts and securing ends of stays to wall or roof complete. |
| 36 | S&F in repairs stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays for 75 mm dia bore pipe, including bolts and nuts and securing ends of stays to wall or roof complete. |
| 37 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 38 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165. |
| 39 | M&L for preparation of new steel surface over 10cm in width or girth not otherwise described and applying two coats of PU enamel paint over a coat of red oxide primer complete. |