| 1 | Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying pipe line etc, complete all as specified and as directed by Engineer-In-Charge.Note :-The quoted rate shall be deemed to have included necessary \"trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete complete including necessary all tools, tackles etc. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge. |
| 3 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge. |
| 4 | Replacement old un-serviceable Sluice Valve with new Sluice Valve, cast iron, Class PN 1.6, size 200mm bore pipe, flanged type, conforming to IS: 14846-2000, ISI marked with stainless steel spindle, brass nuts and iron wheel head including jointing material such as rubber fibre board packing ring and nuts, bolts and washers of suitable size for vertical or horizintal fittings, complete all as specified and as directed by Engineer-In-Charge. |
| 5 | Description all as serial ietm No- 4.00 here-in-before but for 150mm bore pipe. |
| 6 | Description all as serial ietm No- 4.00 here-in-before but for 100mm bore pipe. |
| 7 | Description all as serial ietm No- 4.00 here-in-before but for 80mm bore pipe. |
| 8 | Supply and fixing Tubes, \"medium grade\" galvanised, 15mm bore , ISI markedincluding all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc, laid in trenches or fixed on walls including taking down old tubing, complete all as specified and as directed by Engineer-In-Charge. |
| 9 | Description all as serial item No- 08.00 here-in-before but for 20mm bore pipe.. |
| 10 | Description all as serial item No- 08.00 here-in-before but for 25mm bore pipe.. |
| 11 | Description all as serial item No- 08.00 here-in-before but for 40mm bore pipe. |
| 12 | Description all as serial ietm No- 08.00 here-in-before but for 50mm bore pipe. |
| 13 | Description all as serial item No- 08.00 here-in-before but for 80mm bore pipe. |
| 14 | Description all as serial item No- 08.00 here-in-before but for 100mm bore pipe. |
| 15 | Replacement old un-serviceable gate valve with new gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15mm bore pipe line, complete all as specified and as directed by Engineer-In-Charge. |
| 16 | Description all as serial item No- 15.00 here-in-before but for 20mm bore pipe. |
| 17 | Description all as serial item No- 15.00 here-in-before but for 25mm bore pipe. |
| 18 | Description all as serial item No- 15.00 here-in-before but for 40mm bore pipe. |
| 19 | Description all as serial item No- 15.00 here-in-before but for 50mm bore pipe. |
| 20 | Run lead joint, suitable for cast iron pipes and fittings of 200mm bore including jointing materials such as lead, spun and spun yarn, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. |
| 21 | Description all as serial item No- 20.00 here-in-before but for 150mm bore pipe. |
| 22 | Description all as serial item No- 20.00 here-in-before but for 100mm bore pipe. |
| 23 | Supply only rubber mat with new synthetic rubber insulating mat for preventing HT shock, thickness not less than 25mm, size 2.00x1.00 mtrs, complete all as specified and as directed by Engineer-In-Charge. |
| 24 | M&L for replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead of galvanised iron strip of size 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and20mm bore light gradeGI pipewith funnel and wire mesh for watering including necessaryexcavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR( Part-I) of 2009 and testing on completion. (Note : Earth result should not exceed 2 Ohms) |
| 25 | Replacement old un-serviceable Non Return Sluice Valve with new Non Return Sluice Valve, Class PN 1.6, size 200 mm bore pipe, flanged type, including jointing material such as rubber fibre board packing rings, nuts, bolts and washers of suitable size, complete all as specified and as directed . |
| 26 | Description all as serial ietm No- 25.00 here-in-before but for 150mm bore pipe. |
| 27 | Description all as serial ietm No- 25.00 here-in-before but for 100mm bore pipe. |
| 28 | Description all as serial ietm No- 25.00 here-in-before but for 80mm bore pipe. |
| 29 | Repairs of valve pit of size 900x900x900mm (internal dimensions) including brick masonry, rendering in 15mm thick cement mortar 1:4 on internal and external surfaces and white wahsing with two coats of lime wash including painting with two coats of black colour synthetic enamel paint to mild steel surfaces of angle iron framed work mild steel sheet with mild steel hinges, handles and suitable locking arrangements, fastening arrangements, nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 30 | Repairs of valve pit of size 1200x1200x1200mm (internal dimensions) including brick masonry, rendering in 15mm thick cement mortar 1:4 on internal and external surfaces and white wahsing with two coats of lime wash including painting with two coats of black colour synthetic enamel paint to mild steel surfaces of angle iron framed work mild steel sheet with mild steel hinges, handles and suitable locking arrangements, fastening arrangements, nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 31 | M&L for Construction of brick masonry valve pit of size 1200x1200x1200mm (internal dimensions of chamber) including plain cement concrete, M-7.5 (1:4:8), type-D2 (using 40mm graded crushed stone aggregates) 100mm thick, as in sub baseand PCC M-15 (1:2:4), type-B2 (using 40mm graded crushed stone aggregates) 100mm thick, as in flooring, brick work masonry, 23cm thick in cement mortar 1:4, rendering 15mm thick in cement mortar 1:4 on internal and external surfaces with two coat of lime wash, mild steel framed work as in valve pit covers with angle iron frame 50x50x6mm and including mild steel sheet cover 3.15mm thick complete, drilling/ welding for fixing of steel sheeting with mild steel hinges, handles and suitable locking arrangements, fastening arrangements for fixing, nuts, bolts and washers including painting with two coats of synthetic enamel paint over a coat of red oxide primer, including dismantling of existing valve pit and removal the dismantled material to a distance of not exceeding 50mtrs, complete all as specified and as directed by Engineer-In-Charge. |
| 32 | Cleaning of overhead water tank, capacity 100000 Gallons, height/ staging 18.85mtrs, by scraping with mild steel wire brush and removing all the silt, dirt, algae, sludge etc from the surfaces of walls and floor including removal the same to a distance not less than 50mtrs, washing the cleaned surface with bleaching powder solution thoroughly and applying two coats of lime wash on internal surfaces of reservoir, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, and writing the particulars such as capacity of tank, date/ due date of tank cleaning in bold letters, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, including painting with one coat black synthetic enamel paint to external surfaces of flow pipes with valves any type as connected with overhead water tank and making flow signs with white synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge. |
| 33 | Cleaning of overhead water tank, capacity 50000 Gallons, height/ staging 18.85mtrs, by scraping with mild steel wire brush and removing all the silt, dirt, algae, sludge etc from the surfaces of walls and floor including removal the same to a distance not less than 50mtrs, washing the cleaned surface with bleaching powder solution thoroughly and applying two coats of lime wash on internal surfaces of reservoir, also applying two coats of cement paint of external surfaces of tank with staging after preparation of surfaces, and writing the particulars such as capacity of tank, date/ due date of tank cleaning in bold letters, on table size not less than 60cmx40cm, painted with black and white synthetic enamel paint on external surface, including painting with one coat black synthetic enamel paint to external surfaces of flow pipes with valves any type as connected with overhead water tank and making flow signs with white synthetic enamel paint, complete all as specified and directed by Engineer-In-Charge. |
| 34 | Supply and provide chlorine test kit for the pump house to check the free chlorine level at source & user end at up to 2.0 PPM level complete all as specified and directed. |
| 35 | Testing & checking the Quality of water in following parameter need to dertermine as perIS: 10500-2012 As per IS: 10500-2012 :-(a)Microbial parameter of waterNote : The rates are includes (i)The testing of water is required to be carried out from Govt approved Lab and intimate portability for drinking purpose for the troops and families in Akhnoor mil stn.(ii)Collection of water from tubewell in sterilized bottle obtained from Govt Lab jointly and submit the sample on same to Lab as directed by Engr-in-Charge.(iii)Collection of water reports and submitted to office after testing all as directed by Engr-in-Charge. |
| 36 | Replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 125 Amps, four poles, 415 Volts, AC, 50 Hz, with side handle, conforms to IS:13947 (Part-3); IEC:60947-2, complete all as specified and as directed by Engineer-In-Charge. |
| 37 | Replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 250 Amps, four poles, 415 Volts, AC, 50 Hz, with side handle, conforms to IS:13947 (Part-3); IEC:60947-2, complete all as specified and as directed by Engineer-In-Charge. |
| 38 | Material and labour for replacement of unserviceable MS heavy Column pipe of size 100mmduty of length 3Mtr including suitable flanges on both sides, provn of 8 Nos suitable holes for for fixing purpose and cut portion on both outer side of flanges for placing ofsubmersible cable including provn of suitable 4 Nos strip duly welding on both flanges and provn of one suitable 3mm thick rubber packing, complete all as specified and as directed by Engineer-In-Charge. |
| 39 | Material and labour for replacement of unserviceable MS heavy Column pipe of size 80mmduty of length 3Mtr including suitable flanges on both sides, provn of 8 Nos suitable holes for for fixing purpose and cut portion on both outer side of flanges for placing ofsubmersible cable including provn of suitable 4 Nos strip duly welding on both flanges and provn of one suitable 3mm thick rubber packing,complete all as specified and directed by EIC |
| 40 | Testing of chlorine jointly in presence of operator of 06 Nos tube wells once in a day Morning / Evening before supply hrs to ensure free chlorination 2.0 PPM at source & including routine and periodical maintenance of chemical dozing pumps replacement of defective spare parts to keep them functional at serviceable condition and maintaining record duly signed by operator. Note:- 1.The cost of transportation daily to check tube well in Morning & Evening deemed to be includeed in unit rate of above item. 2.Spare parts required shall be measured and paid separately as supply only. 3.The record of free chlorine check to be put up daily to JE E/M / AGE E/M4.Contractor will be responsible for proper chlorination in all pump houses. In case chlorination is found NIL at any location during oversear the work by concerned JE E/M or Engr-in-Charge the recovery @ Rs 1000.00 will deducted per location, per day, per month from contractors RAR/ Final Bill. |
| 41 | Supply and provide Orthotolidine solution for testing of chlorine in water, complete all as specified and directed. |
| 42 | Replacement of rusted/unserviceable nut, bolts & washers of column pipes of submersible motor of any size/capacity, complete all as directed by Engr-in-charge. |
| 43 | M&L in replacement of rusted/unserviceable MS clamp of suitable size with nut, bolts & washers complete for hanging submersible pump set with column pipes in borewell any size/cap, complete all as specified and as directed by Engineer-In-Charge. |
| 44 | M&L in replacement of rusted/unserviceable MS cap of suitable size as casing cover of borewell, complete all as specified and directed by Engr-in-charge. |
| 45 | Replacement of old unserviceable/ damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge. |
| 46 | Supply ad fixing in replacementcopper lead cable 1.50mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12/ 24 Volts battery including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge. |
| 47 | Supply and fixing Display board, size 1.50X1.20X0.30 mtrs, and cubical type, made of 3.0mm thick acrylic sheet(transparent type) of superior quality having installation details in approved colour letters atleast 12mm wide and 100mm high, cubical shall be fixed on painted angle iron frame of size 40X40X6mm, 1500mm high from ground level, embedded in PCC 1:2:4 below 450mm from ground level,including taking down old board, complete all as specified and as directed by Engineer-in-charge. Note: Colour of letters shall be as approved by Engineer-in-charge. |
| 48 | Lifting up submersible pump set of any capacity alongwith MS/GI column pipe from bore well at different locations including submersible cable of any size by manual or mechanical means after disconnecting all electrical connections from LT panel or starter and transport to workshop for repair and workshop to site after repairing, complete all as specified and directed by Engineer-in-charge. Note : (i) Submersible cable, column pipes to be stacked at asuitable place at TW/pump house for inspection and cleaning properly, with anti sclant solution and painting with synthetic enameled paint.(ii) All T&P shall be arranged by the contractor.(iii) All items taken out from TW/Pump Houses shall be kept in well secured places and shall be the responsibility of the contractor till the machines are not made functional. |
| 49 | Lowering of submersible pump set of any capacity alongwith MS column pipe exc 50 mm dia but not exc 150 mm dia, making flanged joints, cable connections and providing binding dori for binding and packing the submersible cable, complete all as specified & directed. |
| 50 | Dismantling of pump set for inspection and identification of serviceable and unserviceable partsfor repair and overhauling and reassembling after replacement of unserviceable parts complete upto 50 HP submersible pumping set all as specified and directed .Note:- (a) Rate quoted for the this item shall include labour charges for the refixing the serviceable parts and fixing of new parts. (b) Spare parts shall be measured and paid seprately under supply only item. |
| 51 | Replacement of stainless steel pump main shaft suitable for and upto 20 HP pump set all as per existing size and shape, complete all as specified and as directed by Engineer-in-charge. |
| 52 | All as per srl item No 51.0 above but of capacity up to50 HP pump. |
| 53 | Supply and fixing in replacement of GM bushes all as per existing size suitable for submersible pumping set of capacity 30000GPH / 20000 GPH, complete all as specified and as directed by Engineer-in-charge. |
| 54 | All as per srl item No 53.0 above but of capacity 10000GPH / 12000 GPH. |
| 55 | Supply and fixing in replacement of stainless steel bush all as per existing size suitable for submersible pumping set of capacity 30000GPH/20000GPH. |
| 56 | All as per srl item No 55.0 above but of capacity 10000GPH / 12000 GPH. |
| 57 | Supply only of neck ring all as per existing size and shape suitable for submersible pumping set of capacity 30000GPH/20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 58 | All as per srl item No 51.0 above but of capacity 10000GPH / 12000 GPH. |
| 59 | Supply and fixing in replacement of GM impeller all as per existing shape and size suitable for submersible pumping set of capacity 30000GPH/ 20000GPH. |
| 60 | All as per srl item No 59.0 above but of capacity 10000GPH / 12000 GPH. |
| 61 | Supply and fixing in replacement of of CI bowls stage suitable for submersible pumping set of capacity 30000GPH/20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 62 | All as per srl item No 61.0 above but of capacity 10000GPH / 12000 GPH. |
| 63 | Supply and fixing in replacement of studs 100mmx45mm of suitable size, suitable for submersible pumping set of capacity 30000GPH/20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 64 | All as per srl item No 63.0 above but of capacity 10000GPH / 12000 GPH. |
| 65 | Supply only of suction connecting piece CI all as per existing size and shape suitable for submersible pumping set of capacity 30000GPH/20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 66 | All as per srl item No 65.0 above but of capacity 10000GPH / 12000 GPH. |
| 67 | Supply and fixing in replacement of main pump shaft all as per existing shape and size suitable for submersible pumping set of capacity 30000GPH/ 20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 68 | All as per srl item No 67.0 above but of capacity 10000GPH / 12000 GPH. |
| 69 | Supply and fixing in replacement of motor pump coupling with key all as per existing size suitable for submersible pumping set of capacity 30000GPH/20000GPH, complete all as specified and as directed by Engineer-in-charge. |
| 70 | All as per item No 69.0 above but of capacity 5000 GPH. |
| 71 | Supply and fixing in replacement of impeller all as existing size and shape suitable for submersible pump capacity 5000 GPH. |
| 72 | Supply and fixing in replacement of bushes PVC suitable for submersible pump of capacity 5000 GPH, complete all as specified and as directed by Engineer-in-charge. |
| 73 | Supply and fixing in replacement of Submersible cable jointing kit for upto 35sqmm 3 core submersible cable. |
| 74 | Supply and fixing in replacement of Rubber gasket with 8 Nos holes made out of 6mm thick superior quality neoprime sheet suitable for 100 mm bore, complete all as specified and as directed by Engineer-in-charge. |
| 75 | Supply and fixing in replacement of stainless steel sleeves suitable for bowl assy of capacity 30000 GPH, complete all as specified and as directed by Engineer-in-charge. |
| 76 | All as per srl item No 75.0 above but of capacity 10000GPH / 12000 GPH. |
| 77 | Dismantling and re-assemble of submersible electric motor upto 50 HP, 3 phase 440 volts,taking out burnt material and rotor, cleaning and making it smooth for rewinding complete.Note : The items required for repair & replacement will be measured as supply only against relevant item of sch A |
| 78 | Rewinding stator of upto 50 HP motor with existing size and gauge of PVC insulated water proof copper winding wire and insulation material complete all as specified and directed.Make of winding wire Finolex/CCI/KEN.Note : Contracter will giveWarranty of rewinded motor at least 6 month minimum. Contractor will send his rep to Pump House for attending complaint. The contracter will rectified bottlenecks with in 48 Hrs if fail for any reason,a fine of Rs 1000/-day will be imposed for non compliance. |
| 79 | Supply and fixing in replacement of thrust bearing bronze all as per existing shape and size suitable for up to 50HP submersible pump, complete all as specified and as directed by Engineer-in-charge. |
| 80 | Supply and fixing in replacement of thrust plate all as per existing size and shape, complete all as specified and as directed by Engineer-in-charge. |
| 81 | Supply and fixing in replacement of housing bush Gun Metal all as per existing size upto 50 HP motor, complete all as specified and as directed by Engineer-in-charge. |
| 82 | Supply and fixing in replacement of rotor sleeve Gun Metal all as existing size and shape suitable for up to 50 HP submersible electric motor, complete all as specified and as directed by Engineer-in-charge. |
| 83 | Supply and fixing in replacement of rotor seal bush Gun Metal all as existing size and shape suitable up to 50 HP submersible electric motor, complete all as specified and as directed by Engineer-in-charge. |
| 84 | S&F in repair of a submersible pumpof cap to draw the water 20000/30000 glns proppel through submersible motor of cap 20HP deliver at a head of 110/125 meter with 10/12 staging .complete all as specified and as directed by Engineer-in-charge. |
| 85 | Supply and fixing in replacement of \"T\" bolts and nuts all as per exisitng size and shape suitable for submersible electric motor all as per exisitng size and shape, complete all as specified and as directed by Engineer-in-charge. |
| 86 | S&F of Submersible Copper cable 3 core, 10 sqmm including lowering/lifting of submersible pump set MAKE : Finolex/CCI /GLOSTER. |
| 87 | Minor repair of LT/Starter Panels (Guardian) etc. without using any accessories to make the pump sets operational. |
| 88 | Carrying out servicing/maint of 83/100/125 KVA DG set, Make : \"Greaves/Kirloskar/Cummin\"including \"B\" check as per manufacturers mannualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set completeall as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as \"Supply only\" items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item . |
| 89 | (a) Supply only oil filter |
| 90 | (b) Supply onlyDiesel filter |
| 91 | (c) Supply only Fuel filter |
| 92 | (d)Supply only Air clean filter |
| 93 | (e) Supply only Hose pipe & Flexible pipe complete set. |
| 94 | (f) Supply only Fan belt |
| 95 | Carrying out servicing/maint of 62.5 KVA DG set, Make : \"Greaves/Kirloskar/Cummins\"including \"B\" check as per manufacturers mannualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set completeall as directed by Engineer-in-Charge.Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as \"Supply only\" items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item |
| 96 | (a) Supply only oil filter |
| 97 | (b) Supply onlyDiesel filter |
| 98 | (c) Supply only Fuel pre filter |
| 99 | (d) Supply only Air clean filter |
| 100 | (e) Supply only Hose pipe & Flexible pipe complete set. |
| 101 | (f) Supply only Fan belt |
| 102 | Carrying out servicing/maint of35/40 KVA DG set, Make : \"Greaves/Kirloskar\"including \"B\" check as per manufacturers mannualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set completeall as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as \"Supply only\" items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item . |
| 103 | (a) Supply only oil filter |
| 104 | (b) Supply onlyDiesel filter |
| 105 | (c) Supply only Fuel filter |
| 106 | (d) Supply only Air clean filter |
| 107 | (e) Supply only Hose pipe & Flexible pipe complete set. |
| 108 | (f) Supply only Fan belt |
| 109 | Disconnecting electric connections of servo voltage stabilizers, capacity 40 KVA to 100 KVA,draining out the transformer oil in clean barrels for re-use, cleaning of sludge from oil tank and transporting to workshop for repairs and return back to it\"s original position after repairs including loading and unloading by mechenical means, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ. |
| 110 | Supply and fixing in replacement of Sensing card for low and high voltage including connectiing wire capacity 40 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 111 | Supply and fixing in replacement ofCarbon bushes (Set of three) capacity 40 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. |
| 112 | Supply and fixing in replacement of Servo motor, capacity 10 Kgs, 60 RPH, 240 Volts, 50 Hz. capacity 40 KVA to 100 KVA,complete all as specified and as directed by Engineer-In-Charge. |
| 113 | Rewinding ofprimary/ secondary coil of transformer of voltage stabilizer with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge.Note: Coil shall have same number of turns of winding wire and with matching to manufacturer design. |
| 114 | Supply and fixingin replacement of Dimmer Booster Coilfor automatic voltage corrections, make, type and design as per site requirement. |
| 115 | Supply and fixingin replacement of Push button suitable for servo voltage stabilizers of any capacity, as per existing design and range, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. |
| 116 | Supply and fixingin replacement of Digital voltmeter, range 0-500 Volts, size 96mmx96mm, flush type, complete all as specified and as directed by Engineer-In-Charge. |
| 117 | Supply and fixingin replacement of Digital ammeter, range 0-100 Amps, size 96mmx96mm, square shape, complete all as specified and as directed by Engineer-In-Charge. |
| 118 | Supply and fixingin replacement of Selector switch suitable for Voltmeter/ Ammeter as per existing design and range, complete all as specified and as directed by Engineer-In-Charge. |
| 119 | Supply and fixing Phase indicating LED type lamps (RYB), complete all as specified and as directed by Engineer-In-Charge. |
| 120 | Supply and filling in replacement of engine oil/lubricant, 20W40 grade suitable for diesel engine of DG set of any capacity and any make complete all as specified and as directed by Engineer-in-charge. |
| 121 | Supply only fixing in replacement of coolant fluid suitable for radiator of DG set of any capacity and any make, complete all as specified and as directed by Engineer-in-charge. |
| 122 | Supply & installation in replacement of Chlorine dozing system with new Altoch Dosing System , Model ADS-I, Item Nr:- ADS 100 with Non-metallic solution tank of 100 ltrs capacity with motor driven agitator to maintan uniform suspension throughout the tank, electrically operated chlorine dosing tank consisting of Dosing tank of 100 ltrs of PE/FRP MOC with PE/FRP Lid & level gauge along with single phase electric motor and agitator, 90 watts,1440 RPM, 230 Volts, 50 cycles, 02 Amp and having speed controller to reduce speed upto 800 RPM, with shaft & blade in plastic-mounted on tank. Lid must have port hole for pouring calcium hypochlorite and water when necessary. Lid must have provision for mounting dosing pump on the lid/wall incuding High pressure Single head Gear Motored adjusable Dosing Pump Set, Model:- 96 NGQ51, Item NR:- DPP965, uneffected on dry running having no loss of prime, independent of back pressure and able to handle both chemical solutions as well as suspension, 230 volts, 50 cycles, AC, 44 Rpm, 1/30 fraction HP having output 2US GPD to 40 U.S GPD complete with accessories i.e. lead tubing, connecting nuts, injection check valve, clay weight and ferrules incuding complete instalation, complete all as specified and directed by Engr-in-Charge. |
| 123 | Supply, installation, testing and commissioning in replacement of old unserviceable LT panel with new LT panel for electric motor protection unmanned type, solid state, Three phase, 415 Volts, 50 Hz, alongwith digital select metering, protection against high/ low voltage, single phase reserve and unbalance phasing, over loading, dry running, having three Nos. of LED indicators for low voltage current, high voltage, reserve, unbalancing phasing motor, compacted panel for fully automatic mode of operations, wall mounted type, capacity of motor for 50 HP, complete all specified and as directed by Engineer-In-Charge.Note: (i) The installation and fixing of panel shall be as per manufacturer’s directions. (ii) Quoted rate shall be inclusive to making good to the disturbed surface with plastering and painting as per existing specifications. |