| 1 | Cleaning of Sewage line of 100mm bore from gully traps, grease traps etc. upto 1.5m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley complete all as specified and directed. |
| 2 | All as per Item No 1.00 here-in-before but sewage line of 150 mm bore and depth of sewage line upto 2m complete all as specified and directed. |
| 3 | All as per Item No 1.00 here-in-before but sewage line of 200 mm bore and depth of sewage line upto 2m complete all as specified and directed. |
| 4 | Cleaning of septic tank of any capacity or description including cleaning and pumping out fluid, cleaning of sludge from compartment of septic tank including intercepting chamber & washing down withwater complete and removing the sludge in covered van/trolley outside the Govt land complete all as specified and directed. |
| 5 | M & L dewatering of soak well by pumping or any suitable means dia of soak well exceeding 2.50 m and n. exc 3.00 and depth not exc 3.00 complete all as specified and directed. |
| 6 | Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD land and taken out cover slab and reset in the same position after cleaning and testing all as specified and directed. cleaning shall be done either manually or mechanically as required complete all as specified and directed. |
| 7 | All as per Item No. 6.00 here-in-before but depth exceeding 1.5 m and not exc 3 m deep complete all as specified and directed. |
| 8 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified and directed. |
| 9 | M & L for Brickwork with subclass ‘B’ bricks,(OLD SIZE BRICKS) straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 10 | All as per Item No 9.00 herei-in-above but except bricks complete all as specified and directed. |
| 11 | Demolition of Brickwork or stone/ boulder masonry, laid dry and removal complete all as specified and directed. |
| 12 | M & L for brick flooring at any location laid flates bedding and grouting in cement mortar 1:3 and pointed in cement mortar (1:3) using Ist class burnt brick (Best quality) complete all as specified and directed. |
| 13 | M & L for PCC (1:3:6) type C-1 (using 20 mm gradded stone aggregates) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapetscopings,water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed. |
| 14 | M & L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed.Note: Forming fair finished channel for drain using extra cement shall be measured and paid for separately. |
| 15 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 16 | M & L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked), finished even & smooth without using extra cement complete all as specified and directed.Note: Supply only water proofing admixture shall be measured and paid for separately. |
| 17 | M & L rendering 15mm thick in cement mortar (1:6) on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed. |
| 18 | M & L rendering 5mm thick in cement mortar (1:3) on concrete surfaces in ceiling, finished even & smooth without using extra cementcomplete all as specified and directed. |
| 19 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 20 | M & L for preparation of newly BRICK, STONE, CONCRETE, ASBESTOS CEMENT SHEET OR PLASTER Surfaces of any description over 10cm girth or width, not otherwise described and applying Twocoat of weather proof exterior emulsion paint complete all as specified and directed. |
| 21 | M & L for preparation of new plastered surfaces of walls and applyingTwo coats of Oil bounddistemper of approved tint complete all as specified and directed. |
| 22 | M & L for preparation of newly plastered/unplasteredsurfaces of ceilings & applying two coats of oil bound distemper (OBD) complete all as specified and directed. |
| 23 | Demolition ofreinforced cement concrete as in cover/slab of drain/culvert/septic tank/soakage well complete all as specified and directed. |
| 24 | M & L for precast RCC (1:2:4)type C-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in cement mortar (1:6) complete all as specified and directed.Note: Reinforcement shall be measured and paid for separately. |
| 25 | M & L for providing and laying 75mm thickfor precast SFRC drain cover without frame but including complete sides iron sheets (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in square or rectangular shape complete all as specified and directed. |
| 26 | M & L for providing and laying 50mm thickfor precast SFRC drain cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 2 to 3 ton /Sqm in square or rectangular shape complete all as specified and directed. |
| 27 | M & L Mild steelTMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to TMT bar complete all as specified and directed. |
| 28 | Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar complete all as specified and directed. |
| 29 | M & L 150 mm Salt glazed stonware pipelaid and jointed complete with collars complete all as specified and directed. |
| 30 | M&L 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 31 | M & L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 32 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 33 | All as per Item No 32.00 here-in-above exc 1.5 m deep and n.exc 3 m deep complete all as specified and directed. |
| 34 | M & L cement concrete (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 35 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified and directed. |
| 36 | M & L for 150mm dia Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 37 | Dismantling of old PVC (SWR)/CIpipes any type & any size complete all as specified and directed. |
| 38 | S & F PVC (SWR) 110 mm pipe single socket in any length with rubber ring joints fixed to wall /floors or in trenches etc complete all as specified and directed. |
| 39 | S & F PVC (SWR) 75 mm pipe single socket in any length with rubber ring joints fixed to wall / floor or in trenches complete all as specified and directed. |
| 40 | S & F PVC (SWR) bends 110 mm bore complete all as specified and directed. |
| 41 | S & F PVC (SWR) bends of 75mm radius complete all as specified and directed. |
| 42 | S & F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement of outter diameter outlet complete all as specified and directed. |
| 43 | S& F PVC (SWR) junction single, (Single T) equal or unequal of 110mm dia with access door complete all as specified and directed. |
| 44 | S &F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed. |
| 45 | S & F PVC (SWR) vent cowl of 75mm dia complete all as specified and directed. |
| 46 | S & F Sand cast,100 mm diaCast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors and including dismantling of old u/s pipes complete all as specified and directed. |
| 47 | S & F Sand cast,100 mm diaCast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in wall and including dismantling of old u/s pipes complete all as specified and directed. |
| 48 | S & F Sand cast,75 mm diaCast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors and including dismantling of old u/s pipes complete all as specified and directed. |
| 49 | S & F Sand cast,75 mm diaCast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in wall and including dismantling of old u/s pipes complete all as specified and directed. |
| 50 | S & F in repair CI Bends 100 mm dia(any radius),diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 51 | S & F in repair CI Bends 75 mm dia(any radius),diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 52 | S & F 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 53 | S & F 75mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 54 | S & F in repair150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P\" complete all as specified and directed. |
| 55 | Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete,brick work,masonary etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 56 | Excavation in post holes each not exc 0.5 cum, getting out soft/loose soil , returning, filling in and ramming earth or broken rubble mixed with earth aroundin layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 57 | M & L for Plain Cement Concrete Type C2 (1:3:6) (using 40 mm gradedstone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 58 | S & F mild steel work such as angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) including necessary welding where required as per site requirement and other similar works complete, conforming to Gde E-165 (Fe 290) complete all as specified and directed. |
| 59 | S & F mild steel round bars as in tie bars of 10 mm dia and over, fixed to fencing posts including cut to length, bent to shape, welding of bar at spots as directed and other similar works, conforming to Grade E-165 (Fe 290) complete all as specified and directed.Note: Cost of cutting to length, bent to shape rquired & binding with MS wire is included in above rate. |
| 60 | S & F Mild steel screw boltsdia of Neck 5mm to 10mm(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but n exc 10cm long complete all as specified and directed. |
| 61 | Dismantling structural steel work including door /gate , frame ,trusses complete all as specified and directed. |
| 62 | M & L for compound girdersand stachions, lattice giders, aerial masts, stair,gate,frame work , staging for water tanks and the like including caps, bases, splices etc channel sections or angles with plates, including all lattice bars, stiffeners, gussets plates, etc.Fe- 290 (Gde E-165) quality \"A\" complete all as specified and directed. |
| 63 | S & F Rolled mild steel Framed work as in doors or gates of angle or other section confirming to Fe-290with gusset plate , rails braces etc. complete drilled for fixing of steel sheeting or othercoveringdoor etc to be prepared for hanging or slinding with and including either hooks hinges and rollers for slinding gates, guide rail of MS flat and framing required for fixing of rollers, pintle hinges, locking arrangement as required and hanging also fastening and fixing complete using Fe- 290 (Gde E-165) quality \"A\" complete all as specified and directed. |
| 64 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed. |
| 65 | M & L for painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zincchromic primer including preparation of surfaces complete all as specified and directed. |
| 66 | M & L for painting to new or previously untreated steel surfaces of any description n exc 10cm in width or girth with two coats of synthetic enamel paint over a coat of zincchromic primer including preparation of surfaces complete all as specified and directed. |
| 67 | Dismantling of fencing wire mesh,any type complete all as specified and directed. |
| 68 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 69 | Fixingonly chain link fencing including line wires, meshsize 100mmX100mm and 4mm dia of wire etc. including provision of binding wire complete as all specified and directed. |
| 70 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)complete all as specified and directed. |
| 71 | Demolition of cement concrete (un-renforced) in ground floor and paving. N.exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as specified and directed. |
| 72 | M & Lfor 100 mm thick PCC (1:4:8) type D -2 (using 40 mm graded aggregate) as in sub base complete all as specified and directed. |
| 73 | M & L for providing and laying prepolishedcement concrete Chequered tiles 30cmx30cmx25mm thick, with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape heavy duty, set, jointed and pointed in neat cement slurry in floorsover screed bed 15mm thick (1:6) cement mortar complete all as specified and directed. |
| 74 | M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 75 | M & L for 75 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as inplinth protection surface finished fair and even complete all as specified and directed.Note: Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. |
| 76 | M & L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.Note:The rate quoted by tenderer is deemed to included in item for painting any type of Bldgs for married/OTM accn , stores, all type fencing/Gates/concertina Coil angle including any height and width at AF Stn Sarsawa shall be made good by contractor without any extra cost to the Govt. |
| 77 | M & L for preparation of old painted woodenSurfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tintand applying one coat of synthetic enamel paint complete all as specified and directed.Note:The rate quoted by tenderer is deemed to included in item for painting any type of Bldgs for married/OTM accn , stores, all type fencing/Gates/concertina Coil angle including any height and width at AF Stn Sarsawa shall be made good by contractor without any extra cost to the Govt. |
| 78 | M & L for preparation of old PAINTING BRICK, STONE, CONCRETE, ASBESTOS CEMENT SHEET OR PLASTER SURFACES Surfaces of any description over 10cm girth or width, not otherwise described and applying one coat of wheather proofExterior Emulsion Paint (exterior grade) complete all as specified and directed.Note: The rate quoted by tenderer is deemed to included in item for painting any type of Bldgs for married/OTM accn , stores, all typeany height and widthshall be made good by contractor without any extra cost to the Govt. |
| 79 | M & L for exterior or interior waterproof/weather proof cement based1 mm thick puttyonnew plastered/old surfacewall after scrapping to prepare the surface even and smooth complete all as specified and directed. |
| 80 | M & L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 81 | Restraining & resecuringthe old chain link fencing including making good stable etc complete all as specified and directed. |
| 82 | S & F in repairGalvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 83 | Restraining & resecuringthe old Galvanised. 2 strand, steel barbed wire 2.24mm dia barbedincluding making good stable etc complete all as specified and directed. |
| 84 | S & F in repair Punched tape concertina coil any dia or any other coil size of any type of standards,rails etc including provision of mild steel(annealed) binding wire complete all as specified and directed. |
| 85 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed. |
| 86 | M & L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate),as in sub base complete all as specified and directed. |
| 87 | M & L for Vitrified Ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick cement screeding in cement mortar (1:6) complete all as specified and directed. |
| 88 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick coloured (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchand over 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 89 | M & L for Vetrified Ceramic tiles 10mm thick light shade (square/rectangular) polished, area of each tiles nexceeding 0.36, in vertical surfaces as skirting and dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 10mm thick rendering in cement mortar (1:4) complete all as specified and directed. |
| 90 | M & L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed. |
| 91 | M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed cement mortar (1:6) complete all as specified and directed. |
| 92 | M & L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 93 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, Rough finished surfacesof concretec flat complete all as specified and directed. |
| 94 | M & L for Reinforced cement concrete (nominal mix) in Type B1 (1:2:4) (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.Note: Reinforcement shall be measured and paid for separately. |
| 95 | Dismantling water tanks of capacity exc 250ltr but not exc 500ltr and removing from site complete all as specified and directed. |
| 96 | Dismantling water tanks of capacity exc 500 ltr but not exc 1000ltr and removing from site complete all as specified and directed. |
| 97 | S & F 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc all as specified in SSR Part-I complete all as specified and directed. |
| 98 | S & F 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc all as specified in SSR Part-I complete all as specified and directed. |
| 99 | S & F 15mm dia ball valves brass high pressure with polythelene float and fly net complete, screwed iron pipes complete all as specified and directed. |
| 100 | Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 101 | Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 102 | S & F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified and directed. |
| 103 | S & F steel tubing medium grade 20mm bore Medium grade fix to wall/floor fixed complete all as specified and directed. |
| 104 | DismantlingPlain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coveringscomplete all as specified and directed. |
| 105 | M & L for Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 106 | M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedcomplete all as specified and directed. |
| 107 | M & L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore, etc. to store and rubbish not exc. 50m complete all as specified and directed. |