| 1 | Taking down carefully ceiling fan down rod complete all as specified and directed by Engr-in-Charge. |
| 2 | Supply, fixing and testing of anti-suicide fan rod of 20 mm dia, GI tubing medium grade 30cm long as require fixed at site includingclamp sandminor works regarding the fixing of rod and disconnection and reconnection of 3 core copper wire complete all as specified and directed by Engr-in-Charge. |
| 3 | Supply, fixing and testing of anti-suicide fan rod of 20 mm dia, GI tubing medium grade 45cm long as require fixed at site includingclamp sandminor works regarding the fixing of rod and disconnection and reconnection of 3 core copper wire complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F in replacement of copper conductor multistranded standard FRLS PVC insulated 1.5 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L in replacement of wall fan of 450 mm sweep, 3 blade type, 1440 rpm, 80 watts with 3 speed rating suitable for AC supply, 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F air circulator fans, wall mounting type, heavy duty, oscillating up to 60° of size 450 mm sweep, working on 230 volts, single phase, 50 Hz AC supply, 1400 RPM, and fan blade metallic finish complete with Aerodynamically designed balance blade and metallic guard complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed with all fittings including tees , junction boxes, modular GI gang box & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified and directed by Engr-in-Charge. Note: 1) Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. 2) Rates are deemed to be inclusive of Modular GI gang box & cover plates of any module & Quantity as required on site. |
| 8 | One 3 pin socket outlet 5 amps independent board with other switches, with cables 1.5 sqmm size. |
| 9 | One light point/Fan Point control by one switch. |
| 10 | One 3 pin socket outlet point 16 Amps on independent board |
| 11 | S&F modular switch 1 way, 6 Amp 1 module complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F ceiling rose 3 terminal 230 volt complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed suitable PVC conduit with two runs of 6.0 Sqmm and 6.0 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and directed by Engr-in-Charge. Note: The work includes cutting of Chasis and making good the disturbed surfaces and rate deemed to be included in quoted rate. |
| 15 | M&L for distribution boards in sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F flexi connection of size 15mm dia with brass nut 2 Nos suitable for connection of geysers, complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply, installation and testing exhaust fans of 300 mm sweep, AC single phase, 4 blade type, double ball bearing , 1200-1400 rpm,having metallic blades, vibration free balanced impeller of air delivery of 1950 Cum/Hr, metallic finish, power consumption 90 watts complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for installation and testing new Geyser storage type 4/5 star rating having capacity 25 ltrs, ABS body, 2000 watts, 220-240 volts with thermal cut off suitable for AC supply, 50 HZ complete with all standard accessories like inlet and outlet PVC connection of heavy duty type and Non return valve in inlet water supply and 02 Nos angle valve complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F in repairs of following size GI tubing medium grade with all fitting and fixed complete to walls and ceiling or laid in floors of size including all accessories such as tee, bend, elbow and union etc. including making good to disturbed surface of wall and match with the existing one (ISI marked) complete all as specified and directed by Engr-in-Charge:- |
| 20 | 15 mm dia |
| 21 | 20mm dia |
| 22 | M&L for Brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mmwith capstan heads, chromium plated, screwed down high pressure, with lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F steel tubular swaged poles type 410 SP-64 (12 meter long) complete with CI base plate, finial taper plug, bolts, nuts & screwsincluding foundation and coping complete all as specified and directed by Engr-in-Charge. Note: Excavation for fixing the pole is deemed to be included in quoted rate. |
| 24 | S&F LED Flood light150 Watt pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection complete mounting onhigh mast light12 mtr heightincluding clamps, nuts / bots / washers etc connecting with suitable flexible copper conductor cable complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements and comprising of following :- (or as manufactures recommendation and design) including taking down old unserviceable timer panel complete. (a) Incomer MCB TPN 63 Amps, 240/410V- 01 Nos.(b) Digital timer switch - 01 No. (d) Contactor AC 3 rating, 3ph, of capacity 65/100 Amps - 01 No. (e)ON/OFF indicating lamp - 01 Set.(f)Auxillary change over switch 6 A - 01 No |
| 26 | Excavation in trenches soft/loosesoil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depthfor foundation etc or for shaft well, cesspits, manholes, fire hole etc. n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and directed by Engr-in-Charge. |
| 27 | Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-in-Charge. |
| 28 | Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge. |
| 30 | Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and as directed by the Engineer-in-Charge. |
| 31 | S&F MS flat work for mounting of pole, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sqmm, 3.5core complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | M&L for Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm buried directlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron strip 32x6mm sizeby meansof bolts, nuts, check nutsandwashersof galvanisediron and 32x6mm GI strip protected by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC (1:2:4) typeB-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle, excavationand earthworkin any type of soil, charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mash and medium grade GIprotectionpipe 15mm bore 5 Mtr long and GI strip upto main earthingof polecomplete all as shown in electrical plateNo 3 of MES Sch 2022 Part-I complete all as specified and as directed by the Engineer-in-Charge.(i) M&L for earth continuity conductor as Main earthing land fixed to wall as batten etc. all as required of size 20x3mm copper strip. (ii) M&L Tubing GI med grade 40mm dia for protection of earthing strip and passing the Road/passes and etc.(iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 34 | Supply and install hi wall split units indoor/outdoor completewith minimum 5 star rating capacity 1.5 TR complete all as specified and directed by Engr-in-Charge.Note: 1) Making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type), T&P required for installation & making good the disturbed surface is deemed to be included in quoted rates. |
| 35 | Supply, installation, commissioning and testing of evaporative type Air Cooler (Desert Cooler) Steel body minimum 20 gauge, 230 Volts, single phase having capacity of 5000 Cum/Hr including standard accessories like inbuilt float valve, front panel, side panel and storage tank capacity not less than 50 ltrs complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for sub main wiring withunder mentioned run of single core PVC insulated but unsheathed FRLS cable of size 6.0 Sqmm multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium gradeISI marked ( not less than 20 mm) with all conduit fittings & fixing accessories for concealedin wall/ ceiling or surface incl the specified run of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engr-in-Charge.Note : Cutting and chasing of wall & making good surface with plaster work is deemed to be included in rates quoted by contractor. The under mentioned runs of single core cable and specified earth continuity conductor andrelevant conduit with fitting accessories will be measured as one run |
| 39 | S&F MCB Single pole, of capacity 6-32A, 10KA, 240 volt50 HZ complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F 500 litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball PTMT, valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimum weight 210 grams including dismantling old one etc complete all as specified and directed by Engr-in-Charge. |
| 41 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed by Engr-in-Charge.Note: Cleaning repairing, etc. measured separately. |
| 42 | S&F framed work such as grills, gratings, tank cover, drain covers made of angle, channel, bars and sheets etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-O or Fe 310-O complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F welded steel wire fabric not exceeding 4 kg/sqmwelded to steel sections at any position complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint over one coat of red oxide primer (for steel surfaces) complete all as specified and directed by Engr-in-Charge. |
| 45 | Taking down and refixing only old GI tubing 15 mm bore pipe and connections in new or old position as on walls ceiling floors etc. complete all as specified and directed by Engr-in-Charge. |
| 46 | Taking down and refixing only old GI tubing 20mm bore pipe and connections in new or old position as on walls ceiling floors etc. complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply and layingXLPE insulated PVC sheathed, armoured,heavy duty, aluminium conductor electric cable 1100 Volt gradeof4 core10 Sqmm in duct/floor/wall with provision of saddle and lugs, etc including taking down of old one,all as specified and directed by Engr-in-Charge. |
| 48 | Supply onlywiringwith two run of PVC (FR) insulatedmultistranded copper conductor cable of 2.5 sqmm drawing through PVC conduitswith contineous earth wire PVC (FR) insulated cableof size 1.5 sqmmconnected toearth including all conduit accessories. (Note : Two run of sub main wire, one run of earth wire and one run of PVC Conduit pipe measured as one unit). all as specified and directed by Engr-in-Charge. |
| 49 | S&F Bollard light fitting decorative illuminated cross that appears to be made using computer numerical control laser cut techniques, cross features a distinctive geometric \"jaali\" (screen or lattice) pattern on its vertical and horizontal beams, at the centre where the beams intersect, there is circular emblem featuring a unit logo design with the letters \"7 BRD\" inscribed on it and made of die-cast aluminiumluminaires for downward lighting with high power LED 05 Nos as light source with epoxy powder coated black after phosphochromeate treatement of 30 Watt capacity, height 4000mm and width 200mm, IP65 protection all as specified and directed by Engr-in-Charge. |
| 50 | Supply and lay High density poly ethylene pipes (HDPE) 25 mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. all as specified and directed by Engr-in-Charge. |