| 1 | SH: Type-II Teacher Qtr. 1 (one) No. |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | Sh:- Cement Concrete Work |
| 6 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 7 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 8 | Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size). |
| 9 | Sh:- RCC Work |
| 10 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 11 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. (a) M 201 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 12 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. (A) M20 ( 1Cement : 1.5 Coarse sand :3 Stone Aggerate 20 mm nominal size.) |
| 13 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforcement of RCC work including bending, binding and placing in position complete (a)Tar/TMT steel |
| 15 | Centring and shuttering including strutting, propping etc and removal of form work for a) Foundation footings, bases of columns etc. and mass concrete |
| 16 | b) Column, pillars, posts and struts etc. |
| 17 | c) Walls including attached buttresses, pilasters etc |
| 18 | d) Lintels, beams, girders, bressumers and cantilevers etc |
| 19 | e) Suspended floors, roofs, landings Shelves and their supports, balconies and chajjas (3.5 mtr Height) |
| 20 | Sh:- Brick Work |
| 21 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 22 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 23 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 24 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 25 | Sh:- Wood Work |
| 26 | Providing approved best available local wood (Class- B-II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 27 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 28 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I |
| 29 | Providing and fixing 30 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including bright finished or and black enamelled iron wire butt hinges with necessary screws.a) 2nd class approved local wood class - B I. |
| 30 | Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nuts and screws etc complete.Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nuts and screws etc complete.a) 300 x 16 mm |
| 31 | Providing and fixing MS Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.200x10mm |
| 32 | 150x10mm |
| 33 | Providing and fixing MS Handles anodised transparent or dyed to required color or shade with necessary screws etc complete 125mm |
| 34 | 100mm |
| 35 | Providing and fixing MS hooks & Eyes. (b) 250mm |
| 36 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round barswith roundheaded boltsand nuts or by screws.a)Plain grills |
| 37 | Providing and fixing 40x3mm flat iron hold fasts 40cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x 15cm in1:3:6(1cement:3sand: 6hard stone chips 40 mm nominal size). |
| 38 | Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc. |
| 39 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. a) Timber class - A IV |
| 40 | Sh:- Steel Work |
| 41 | Providing and fixing MS fan clamp type I of 16mm dia MS bar bent to shape with hooked ends in RCCslabs during laying including painting the exposed portion of loop all as per standard design complete. |
| 42 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 43 | Welding by Electric plant |
| 44 | Sh:- Flooring |
| 45 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40mm thick |
| 46 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completea) Size of Tile 600x600 mm |
| 47 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.a) Size of Tile 600x600 mm |
| 48 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 49 | SH: ROOFING WORK |
| 50 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Blue scope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses |
| 51 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by themanufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. |
| 52 | Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately). |
| 53 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood. |
| 54 | Extra for making chamfered edges of beading. |
| 55 | Sh:- Finishing |
| 56 | 12 mm cement plaster 1 : 5 (1 cement : 5 fine sand). |
| 57 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 58 | 6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand). |
| 59 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 60 | Interior apply: Applying one coat of wall putty of approved brand manufacture on wall surface |
| 61 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 62 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 63 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 64 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 65 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 66 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 67 | Sh:- Miscellanious Works |
| 68 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement :3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mmbed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 69 | Sh:- Drainage |
| 70 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 71 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipe |
| 72 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipe |
| 73 | Constructing brick masonry manhole with 2nd class bricks in cemen tmortar1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand :4stone single 20mm nomina lsize), foundation concrete1:4: 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete1:2:4mix(1cement:2coarse sand:4stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a)Inside size 90x80cm and 45cm deep including CI cover with frame (light duty) 455x610mm interna ldimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 74 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 75 | SH:- Water Supply Works |
| 76 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15mm Nominal bore |
| 77 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 20 mm Nominal bore |
| 78 | Providing and fixing brass bib cock of approved quality. a) 15mm Nominal bore |
| 79 | Providing and fixing brass stop cock of approved quality. a) 15 mm Nominal bore |
| 80 | Providing and fixing PVC connection pipe with brass union.B) 30 cm lengtha) 15 mm nominal bore |
| 81 | Sh:- Sanitary Work |
| 82 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan |
| 83 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste and making good the walls where required. Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 84 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 85 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 86 | Providing and fixing CP brass waste for wash basins and sinks. a) 32 mm dia |
| 87 | Providing and fixing CP Brass or MI trap for wash basin and sinks.a) 32 mm dia |
| 88 | Providing and fixing sand cast iron/ cast iron (spun) soil, Waste and vent pipe a) 100 mm dia |
| 89 | b) 50mm dia |
| 90 | Providing and fixing sand cast iron single equal plain junction of required degree.a) 100 x 100 x 100 mm |
| 91 | SH: Boundary Wall (Length 425.00 mtr) |
| 92 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 93 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 94 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 95 | Reinforcement cement concrete work in columns, pillars,piers,abutments, post and struts etc upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 96 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar1:3 (1cement:3finesand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 97 | Centring and shuttering including strutting, propping etc and removal of form work for a) Lintels, beams, girders, bressumers and cantilevers etc. |
| 98 | b) Column, pillars, posts and struts etc. |
| 99 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel |
| 100 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 101 | Extra for half brick masonary in superstructure above floor two level. |
| 102 | Providing and fixing Barred Wire Round Type of required pattern with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Barred Wire |
| 103 | 12 mm cement plaster 1 : 64(1 cement : 4 fine sand). |
| 104 | Colour washing such as green, blue or buff on new work (two or more coats) including a base coat of white washing with lime to give an even shade |
| 105 | SH: MS Gate 1(one) No. |
| 106 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 107 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 108 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 109 | Reinforcement cement concrete work in columns, pillars,piers,abutments, post and struts etc upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 110 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar1:3 (1cement:3finesand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 111 | Centring and shuttering including strutting, propping etc and removal of form work for a) Lintels, beams, girders, bressumers and cantilevers etc. |
| 112 | b) Column, pillars, posts and struts etc. |
| 113 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 114 | Colour washing such as green, blue or buff on new work (two or more coats) including a base coat of white washing with lime to give an even shade. |
| 115 | Providing and Fixing MS Gate/ Grill of required Pattern with MS flate, Square or round bars with roundheaded bolts & Nuts or by screws. a) MS Gate |
| 116 | SH: Additional Class Room 2(two) Nos |
| 117 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 118 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 119 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 120 | Sh:- Cement Concrete Work |
| 121 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 122 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 123 | Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size). |
| 124 | Sh:- RCC Work |
| 125 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 126 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. (a) M 201 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 127 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. (A) M20 ( 1Cement : 1.5 Coarse sand :3 Stone Aggerate 20 mm nominal size.) |
| 128 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20(1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 129 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 130 | Reinforcement of RCC work including bending, binding and placing in position complete (a)Tar/TMT steel |
| 131 | Centring and shuttering including strutting, propping etc and removal of form work fora) Foundation footings, bases of columns etc. and mass concrete |
| 132 | b) Column, pillars, posts and struts etc. |
| 133 | c) Walls including attached buttresses, pilasters etc |
| 134 | d) Lintels, beams, girders, bressumers and cantilevers etc |
| 135 | e) Suspended floors, roofs, landings Shelves and their supports, balconies and chajjas (3.5 mtr Height) |
| 136 | Sh:- Brick Work |
| 137 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:5 (1 cement : 5 fine sand). |
| 138 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 139 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 140 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 141 | Sh:- Wood Work |
| 142 | Providing approved best available local wood (Class- B-II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 143 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I |
| 144 | Providing and fixing 30 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including bright finished or and black enamelled iron wire butt hinges with necessary screws.a) 2nd class approved local wood class - B I. |
| 145 | Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nuts and screws etc complea) 300 x 16 mm |
| 146 | Providing and fixing MS Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 200x10mm |
| 147 | b) 150x10mm |
| 148 | Providing and fixing MS Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a)125mm |
| 149 | b)100mm |
| 150 | Providing and fixing MS hooks & Eyes. (b) 250mm |
| 151 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round barswith roundheaded boltsand nuts or by screws. a)Plain grills |
| 152 | Providing and fixing 40x3mm flat iron hold fasts 40cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x 15cm in1:3:6(1cement:3sand: 6hard stone chips 40 mm nominal size). |
| 153 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. a) Timber class - A IV |
| 154 | Sh:- Steel Work |
| 155 | Providing and fixing MS fan clamp type I of 16mm dia MS bar bent to shape with hooked ends in RCCslabs during laying including painting the exposed portion of loop all as per standard design complete. |
| 156 | Sh:- Flooring |
| 157 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40mm thick |
| 158 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor. a) 18 mm thick |
| 159 | Extra for providing and fixing glass strips in joints of terrazzo floor.a) 40 mm wide and 4 mm thick |
| 160 | SH: ROOFING WORK |
| 161 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/and residual bitumen applied hot @ 1.45 Kg. per Sq.m. of area for each courses, second course of roofing felt type-3 grade-I (hessian base self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 162 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand). a) 100 mm diameter pipe |
| 163 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand). (A) CI Plain benda)100 mm diameter |
| 164 | Sh:- Finishing |
| 165 | 12 mm cement plaster 1 : 5 (1 cement : 5 fine sand). |
| 166 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 167 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 168 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 169 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 170 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 171 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 172 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 173 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 174 | Sh:- Miscellanious Works |
| 175 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement :3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mmbed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 176 | Sh:- Drainage |
| 177 | e) Suspended floors, roofs, landings Shelves and their supports, balconies and chajjas (3.5 mtr Height) |