Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out soft/loose soil etc complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and directed. |
| 3 | All as per ser item No. 2 here-in-before but additional 1.5m or part thereof in depth beyond the first 1.5 mand getting out in soft/loose soil etc complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmloose/soft soil etc complete all as specified and directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointetc complete all as specified and directed. |
| 6 | Rough excavation not exe 1.5 m deep and getting out in soft and loose soil complete all as specified and directed. |
| 7 | All as per ser item No 06here-in-before butexe 1.5 mn.exe 3m deep and getting out in soft /loose soil complete all as specified and directed. |
| 8 | Removing excavated material to a distanceexc 250m but not exc 500 and depositing where directed complete all as specified and directed. |
| 9 | Excavating over areas, n exc 1.5m deep for foundation and getting out in soft / loose soil complete all as specified and directed. |
| 10 | Excavating in over areas exc 1.5m and n exc. 3.0m depth for foundation etc. and getting out soft/loose soil complete all as specified and directed. |
| 11 | Excavating in over areas exc 3.00m and n exc. 3.0m depth for foundation etc. and getting out soft/loose soil complete all as specified and directed. |
| 12 | Excavating in over areas exc 4.5m and n exc. 6.0m depth for foundation etc. and getting out soft/loose soil complete all as specified and directed. |
| 13 | Removing excavated material exc 50m but n.exc 100m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 14 | M&L cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concreteetc complete all as specified anddirected. |
| 15 | M&L RCC(Design Mix) M-25(using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. |
| 16 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for flat rough finished concrete etc complete all as specified and directed. |
| 17 | M&L RCC(Design Mix) M-25(using 20 mm graded stone aggregate) asin beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed. |
| 18 | M&L for formwork to sides and soffits of floor or roof beam, beam hauchings girders, bressummers, lintels etc. for rough finished surfaces ofconcrete etc complete all as specified and directed. |
| 19 | M&L RCC(Design Mix) M-25(using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 20 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular on plan or polygon for rough finished surfaces ofconcreteetc complete all as specified and directed. |
| 21 | M&L TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 22 | All as per ser item No 21 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 23 | M&L RCC(Design Mix) M-25(using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deckslabs and in shelves and the like (tank slab) etc complete all as specified and directed. |
| 24 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces ofconcrete etc complete all as specified and as directed. |
| 25 | M&L brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m meanradius built in CM 1:6 complete all as specified and directed. |
| 26 | M&L for 10 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed. |
| 27 | M&L for rendering 5 mm thick in CM 1:3 on ceiling surface finishedeven and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for 15 mm thick rendering in CM 1:4 on other than fair faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed. |
| 29 | Supply only integral waterproofing compound complete all as specified and directed. |
| 30 | M&L for applying three coats of white wash on wall including preparation of plastered or un-plastered surfaces of walls, complete all as specified and directed. |
| 31 | M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 32 | M&L for applying two coats of cement base paint on wall over a coat of priming paint including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 33 | M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 34 | M&L for eves board 1.40 mm thick with angle iron/flat iron space between wall iron framed work such as grills, gratings, etc. with ends of bars shoulderedand/orriveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings, frameworkof water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified anddirected. |
| 35 | M&L framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 36 | M&L for 6mm thick E board (classic) of size 610mmx610mm as in false ceiling fixed with aluminium snap grid frame work of same size as aluminium Tee of size 25mmx25mmx1.50mm as main runner, 25mmx25mmx1.25mm thick aluminium Tee as cross runner and aluminium angle of size 25mmx25mmx1.25mm at the perimeter including GI adjustable suspender of required length including taking down dismantling existing old ceiling of any description complete all as specified and directed. |
| 37 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering /cladding to wall , fixed with self tapping screws andfor flashing include for embedding mortar alongwith other labour and materials required to complete the work. complete all as specified and directed. |
| 38 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self tapping screws and for flashing include for embedding mortar alongwith other labour and materials required to complete the work complete all as specified and directed. |
| 39 | M&L for moorum/red bajri filling in floors or pavings laid in layers n exc 15cm thick spread, levelled and rammed including watering complete all as specified and directed. |
| 40 | M&L for hardcore of gauge n exc. 63 mm, broken stone broken orbouldersdeposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified anddirected. |
| 41 | M&L for 75 mm thick cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate)as in sub base of floors complete all as specified and directed. |
| 42 | M&L for 75 mm thick cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in floors to be finished even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&L for 150 mm thick cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in platform of ramp to be finished even and smooth without using extra cement complete all as specified and directed. |
| 44 | M&Lfor non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 laid over and including 25mm thick PCC 1:2;4 type B1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed. |
| 45 | M&L for glazed ceramiccolored tiles 300mm x 200mm and 7mm thickas in vertical surfaces such as skirting, dados etc jointed in neat cement slurry and pointed in white or colored cement to match, set and jointed in neat cement slurryover and including 15mm thick backing coat in CM 1:4 laid,complete all as specified and directed. |
| 46 | S&F for 1.2 mm thick Pressed steel frames size 125mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. |
| 47 | S&F 35 mm thick 2nd class hard wood (Hollock/Sal/Bijasal), locally fabricated glazed skeleton doorshutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified inSSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed. |
| 48 | S&F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 49 | S&F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed. |
| 50 | S&F mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed. |
| 51 | S&F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed. |
| 52 | S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 53 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail.MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement including 3 Nos stainless steel hinges, 100mm long, 2 Nos aluminium handle 150mm long and 2 Nos aluminium tower bolt 200mm long fixed to each shutter complete all asspecified in clause No. 8B.2 at Sl page No. 143 to 144 and shownin drawingon sl page No 156of SSR 2010 respectively complete all as specified and directed. |
| 54 | S&F factor made solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying & fixing in opening as specified in clause No. 8B.3 at Sl page No. 145 and shown in drawing on sl page No 160 of SSR 2010 respectively and directed. |
| 55 | S&F 200 mm long MS barrel tower bolts stone enamelled black, with bright boltcomplete all as specified and directed. |
| 56 | S&F 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 57 | S&F 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed. |
| 58 | S&F 125mm long MS handles, pressed and type stone enamelled black complete all as specified and directed. |
| 59 | S&F 300mm, MS ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed. |
| 60 | S&F 2nd class hard wood small fittings suchas brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary\" labours, articles n exc 200 cu. cm each complete all as specified and directed. |
| 61 | M&L for applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer including preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth complete all as specified and directed. |
| 62 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. |
| 63 | S&F 75 mm dia of PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed |
| 64 | S&F 110mm dia of PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenchescomplete all as specified and directed. |
| 65 | S&F 75 mm dia of PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenchescomplete all as specified and directed. |
| 66 | M&L for vitreous China squatting Pan \"Orissa Pattern\" size 580mm x 440mm white with integral foot rests including flush pipe of PVC 32mm dia for low level cisternincluding connection to trap, \"P\" trap and to flushing pipe, anti-syphonage pipe, etc. including making good to floor complete all as specified and directed. |
| 67 | M&L for vitreous China wash basin, white, flat back, size 550 x 400mm excluding taps, chain and plug and porcelain stopper butincludingwaste pipe and coupling 32mmfor basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including MS brackets & flush pipe of polyethylene of high density complete all as specified and directed. |
| 68 | S&F for vitreous China bowl urinal flat back, size of 465mmx355mmx265mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and directed. |
| 69 | S&F steel rolling shutters 1.00mm thick of laths , without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type complete all as specified and directed. |
| 70 | S&F 500 ltrs capacity rotational moulded polyethylene water storage tank triple layered, ISI engraved (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed. |
| 71 | S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight- 210 gm) complete all as specified and directed. |
| 72 | M&L for PCC 40mm thick1:2:4 type B-0 damp proof course using water proofing compound to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately. |
| 73 | S&F for swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)with arm195mm long, bend of 45 degree and flange of PTMT any colour (Minimum weight 40gms) complete all as specified and directed. |
| 74 | M&L for lagging on pipe of internal dia 20mm used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9843not exposed to weather complete all as specified and directed. |
| 75 | S&F PTMT towel rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and directed. |
| 76 | S&F for PVC (SWR) WC connector with lip ring 110mm complete all as specified anddirected. |
| 77 | S&F for PVCvalve-less syphonic flushing cistern of 10 ltr capacity, low level white with inlet ball valve float and handle including brackets complete all as specified and directed. |
| 78 | S&F for Soap dish, vitreous China white, approximate size 160mmx 160mmx90mm complete all as specified and directed. |
| 79 | S&F PVC connection pipe of 15mm dia and 600mm long with PTMT nuts and washer complete all as specified and directed. |
| 80 | S&F for Stop valve fancy type, chromium plated with long shankandcup (concealed type) of 15mm bore, for PPR pipe or for unions complete all as specified and directed. |
| 81 | M&L for CP Pillar taps fancy type,with capstan head chromium plated of 15 mm bore complete all as specified and directed. |
| 82 | S&F for bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe of for brass ferrule of 15mm bore (ISI marked) complete all as specified and directed. |
| 83 | S&Ffor 16mm outer dia of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 84 | S&F for 20mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 85 | S&F for 600x450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 86 | Construction of 10 users septic tank (brick construction) including inlet and out let chamber with top of slab at ground level including necessary earth work and disposal of surplus soil to a distance not exceeding 50m supplying and placing vent pipe, in position to manhole cover brick construction and all other relevant works, complete with, upflow filter and media complete all as specified and shown on drawing No CESZ/TD-1080/2011 Sheet 1/1 dated 01.12.2011. |
| 87 | Construction ofSoakage wells, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combedmasonry with top ring of M25 concrete including intercepting chamber and screen chambermade ofBrick masonry in CM, RCC cover slab in M25/SFRC cover, inter connecting pipes ofRCC/DWC complete filled with brick bats of size 1.80 m dia x 3.0m effective depth complete all as specified and directed shown on drawing No CESZ/TD-01/2015 Sheet 3/3 dated 22.02.2015 . |
| 88 | M&L for PCC M 7.5 (Nominal Mix) type D-2, (using 40mm graded stone aggregate) as in bed of drain pipe 150 mm dia (nominal) including packing under and hanuching against the sides of pipe after they are laid and tasted complete all as specified. |
| 89 | M&L PCC 1:3:6, (Nominal Mix) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 90 | M&L brick work sub class \"B\" old sizebrick, straight or curved on plan exceeding6m mean radius built in CM 1:4 as in man holes and repairs compete all as specified and directed by Engr-in-Charge. |
| 91 | M&L PCC 1:2:4, type B -1 (using 20 mm graded stone aggregate) cast in situ in lintels upto 1.5 m span, cills and other similar bands, plinth course, parapets, coping, bed plates and the like including weathering slightly, water through all as specified and directed by Engr-in-Charge. |
| 92 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in surface channel and drain of manholes etc completeall as specified and directed by Engr-in-Charge. |
| 93 | M&L for extra for forming fair finished drain or channel 50cm inner girth in cement concrete using extra cement including forms moulds, mitred /stopped ends etc all as specified and directed by Engr-in-Charge. |
| 94 | M&L for 15mm thick rendering cement plaster in CM 1:4 on other thanfair faces ofbrick masonry surface finished even and smooth without using extra cement complete as specified and directed by Engr-in-Charge. |
| 95 | M&L 150 mm thick reinforced concrete pipes, class NP2 laid and jointed complete with collars complete all as specified and directed. |
| 96 | M&L precast RCC 1:2:4 type B1 cover slab (using 20mm graded stone aggregate) with plain fair faces including chamfers, weathering and setting in CM 1:6 including necessary form work complete all as specified and directed. |
| 97 | M&L for stone walling of random rubble stone masonry, brought upto course well bonded, bedded and solidly hearted built in CM 1:4 including providing weep holes, complete all as specified and directed. Note : - Deduction of volume occupied by PCC bond stone shall be made and payment of stone masonry shall be made based on net measurement only. |
| 98 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed face beds and joints of random rubble walling uncoursed or brought upto course surface n exc.40mm in granite or trap stone complete all as specified and directed. |
| 99 | S&F 110 mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 100 | M&L precast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) set in cement mortar 1:4 as in bond stone walling, complete all as specified and directed. |
| 101 | M&L for stone/boulder filling, laid dry, hand packed tightly around weep hole complete all as specified and directed. |
| 102 | M&L for raised pointing to random rubble stone masonry , uncoursed or brought upto courses in cement mortar 1:3 complete all as specified and directed. |
| 103 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming and finishing to required height etc., n exc. 1.5 m high above base complete all as specified and directed. |
| 104 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming and finishing to required height etc. Exc 1.50m butn exc. 3.00 m high above base complete all as specified and directed. |
| 105 | M&L providing cement concrete (Design Mix) M-15 1:2:4 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete) complete all as specified and directed. |
| 106 | M&L for formwork to sides of curved concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces of concrete complete complete all as specified anddirected. |
| 107 | M&L for formwork to sides of concrete face of wall, parapers and staircase railings and similar work including attached pilasters, buttresses etc. vertical or to batter fair finished curved surfaces of concrete all as specified and directed. |
| 108 | M&L for formwork to sides and soffits of domes, vaults, shell roofs and arch ribs rough finished add for fair surfaces of finished concrete curved in curved in one plane completeall as specified and directed. |
| 109 | M&L 550D TMT CRS (Corrosion resistant) mild steel bars 10mm and above cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed. |
| 110 | M&L 550D TMT CRS (Corrosion resistant) mild steel bars 5-8 mm for Stirrups, cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed. |
| 111 | M&L 550D TMT CRS (Corrosion resistant) mild steel bars 6-8 mmfor slab, cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm diacomplete all as specified and directed. |
| 112 | M&L RCC M-30 (Design Mix), (using 20mm graded stone aggregates) as in foundation, footing, plinth beams, base for column etc. and mass concrete complete all as specified and directed. |
| 113 | M&L RCC M-30 (Design Mix), (using 20mm graded stone aggregates) as in Walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttressesand like complete all as specified and directed. |
| 114 | M&L RCC M-30 (Design Mix), (using 20mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m spansand like complete all as specified and directed. |
| 115 | M&L RCC M-30 (Design Mix), (using 20mm graded stone aggregates) as in domes, vaults, shell roofs, arch ribs and folded plates, and like complete all as specified and directed. |
| 116 | M&L 15mm thick rendering in cement mortar 1:3 on concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 117 | M&L5 mmthick rendering in cement mortar 1:3 onceiling surfaces finishing even & smooth without using extra cement complete all as specified and directed. |
| 118 | M&L 15mm thick rendering in cement mortar 1:3screed bedof floor surfaces with water water compound on concrete surfaces finished even & smooth without using extra cementcomplete all as specified and directed. |
| 119 | M&L two coats of cement based paintover a coat of alkali resistant primer over new plastered/unplastered surfaces including preparation of surfaces complete all as specified and directed. |
| 120 | M&L for 100mm thick cement concrete 1:3:6,type C-2 (using 20mm graded stone aggregate) as in plinth protectionwithmastic compoundfinished even and smooth without using extra cement complete all as specified and directed. |
| 121 | M&L for bitumen blown 80/25, applied hot, two coats, to concrete surfaces at the rate of 1.5Kg per sq. m per coat over bituminous primer@10Kg/10sqmcoat on outer face of wall complete all as specified anddirected. |
| 122 | M&L for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) in surface drains complete all as specified and directed. |
| 123 | Supply and applying NITTO bond compound all as specified |
| 124 | S&F water Bar (Rubber) inserted between reinforcementconcretewalls surfaces complete all asspecified and directed by Engr-in-Charge. |
| 125 | S&F 150 mm GI tubes, \"medium grade\" galvanised, with all fitting and fixed complete to inlet pipes and out let pipes in walls, ceilings or laid in floors complete all asspecified and directed. |
| 126 | M&L 100 mm thick Cast ironspun pipe soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in walls complete all as specified and directed. |
| 127 | S&F for 75 mm dia CI pipe vent cowl complete all as specified and directed. |
| 128 | M&L for 100mm thick plain cement concrete1:3:6, type C 2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 129 | M&L 80mm thick, machine pressed precast concrete interlocking paver block, with grey cement and and no pigment,any shape and size confirming to IS 15658-2006, M-40 Grade complete all as specified and directed.Note: Sand Cushioning shall be measured and paid separately. |
| 130 | M&L for sand cushion under paving block including watering and consolidation for interlockingtiles complete all as specified. |
| 131 | Siting, boring and testing of trial bore hole suitable for 200mm bore MS casing pipe in any type of strata including soft / hard rock by DTH /ODEX/ Rotary combination rig and getting out for upto 50 mtr depth below ground level.Note:- (i) The diameter of the bore hole should be sufficiently large enough for lowering well assembly of 200mm casing pipe and packing of gravel around MS Casing from top to bottom.(ii) The contractor shall submit a report for siting of the borewell. The siting is to be conducted by qualified team. Any failure in siting proper location will render the bore null and void - Proper location means only suitable location for continuous water output of 35 laps (for upto 12 hours a day). It does not refer to the quality of water(iii) Testing of yield will be conducted for 24 hours with measurement using a water meter for measuring(iv) The quantity maybe increased/ decreased if desired water output is not received/ received early or for other reasons as decided by engineer in charge |
| 132 | All as per ser Item No 131 here-in-before but depth from 51 to 100 mtr below ground level |
| 133 | All as per ser Item No 131 here-in-beforebut depth from 101 to 150mtr below ground level |
| 134 | Supplying, assembling and lowering 200 mm nominal bore mild steel ERW ISI marked casing blind pipe having wall thickness 8.0 mm as per IS-4270-1992 and jointing with electric arc welding, in random length of 3 to 6 metre, jointing and painting with two coats of bituminous paint of external surfaces of pipe complete all as specified and directed. |
| 135 | Supply, assembling and lowering 200mm nominal bore MS ERW fine cut pipe having wall thickness 8mm, slotted pipe conforming to IS-4270-1990 with slot of size 1/8\" wide & 3\" long each and numbers as per location of intermediate aquifers, complete all as specified and directed. |
| 136 | Supply and lowering in borewell, MS ERW column pipe 80 mm bore in 3 mtr length both end flanged with MS flanges 10 mm thick with cut for passing the submersible cable and four no. of holes 10 mm dia with suitable size of nuts, bolts, washers, and rubber gasket complete all as specified and directed.Note: All arrangement andT&P required for lowering the column pipe in the bore shall be made by the contractor under their own arrangement at no extra cost. |
| 137 | S&F casing caping 200mm dia highly tempered with (MS-AN4Z) grade made out of MS sheet 3 mm thick and fixing with MS clamps 50x6 mm FI with nuts, bolts and washers complete in all respect all as specified and directed. |
| 138 | Development of borewell as per IS-2800 by means of compressor of min 250 PSI capacity air compressor until the sand free water is obtained from the well for an uninterrupted period of 16 hours in a cycle of 24 hours. The final discharge shall be free form sand to deliver yield as quoted above and carrying out necessary yield test by V notch method/ by using water meters and submitting the test report complete all as specified and directed by Engr-in-Charge. |
| 139 | Supply, laying/ fixing cable for flat submersible with stranded copper conductor 3 core 1100 Volts grade 6 Sqmm cross sectional area confirming to relevant IS complete all as specified and directed. |
| 140 | M&L for best quality pea gravel of mixed size varing 4 mm to 5 mm and packing the same around casing pipe from top to filter portion in the almost top complete all as specified and directed. |
| 141 | Supply, installation, testing and commissioning of submersible centrifugal pumping set, multi-stage (minimum five stages), suitable for installation in 150 mm to 200 mm diameter bore well, complete with stainless steel pump shaft and stainless steel impellers, suitable for connection to 80 mm nominal diameter rising main, capable of delivering minimum 425 LPM discharge against a total head in the range of 150 to 230 metres. The pumping set shall comprise a submersible electric motor of adequate power, 3-phase, 415 V ±10%, 50 Hz AC, IE3 / 5-Star energy efficient, suitable for continuous duty, complete with all standard accessories, complete all as specified and directed. |
| 142 | Supply only (after testing at site) of submersible centrifugal pumping set, multi-stage (minimum five stages), suitable for installation in 150 mm to 200 mm diameter bore well, complete with stainless steel pump shaft and stainless steel impellers, suitable for connection to 80 mm nominal diameter rising main, capable of delivering minimum 490 LPM discharge against a total head in the range of 150 to 230 metres. The pumping set shall be complete with submersible electric motor of adequate power, 3-phase, 415 V ±10%, 50 Hz AC, IE3 / 5-Star energy efficient, suitable for continuous duty, complete with all standard accessories, complete all as specified and directed. |
| 143 | Supply, installation, testing and commissioning of submersible centrifugal pumping set, multi-stage (minimum five stages), suitable for installation in 150 mm to 200 mm diameter bore well, complete with stainless steel pump shaft and stainless steel impellers, suitable for connection to 80 mm nominal diameter rising main, capable of delivering minimum 490 LPM discharge against a total head in the range of 150 to 170 metres. The pumping set shall be complete with submersible electric motor of adequate power, 3-phase, 415 V ±10%, 50 Hz AC, IE3 / 5-Star energy efficient, suitable for continuous duty, complete with all standard accessories, complete all as specified and directed. |
| 144 | Supply only (after testing at site) of submersible centrifugal pumping set, multi-stage (minimum five stages), suitable for installation in 150 mm to 200 mm diameter bore well, complete with stainless steel pump shaft and stainless steel impellers, suitable for connection to 80 mm nominal diameter rising main, capable of delivering minimum 490 LPM discharge against a total head in the range of 150 to 170 metres. The pumping set shall be complete with submersible electric motor of adequate power, 3-phase, 415 V ±10%, 50 Hz AC, IE3 / 5-Star energy efficient, suitable for continuous duty, complete with all standard accessories, complete all as specified and directed. |
| 145 | Strata sample box (for keeping 75 samples) made out of 20mm thick veneered particle board and 12mm thick ply wood with 25mmx25mm aluminium angle 2mm thick bearer overall length 1200mm x 750mm x 100mm with front glass sheet sliding type cover with aluminium frame all around 2 Nos key holes plate of size 40mm x 25mm and 3mm thick complete showing name of tube well, location and strata sample with depth complete all as specified. |
| 146 | M&L for chemical/bacteriological analysis and portability test of water obtained from borewell from Government lab or government approved lab and submitting the report in triplicate complete all as specified and directed.Note : One test shall be conducted on water obtained during boring and one test shall be conducted on water obtained after the completion of the project |
| 147 | S&F in renewal of starter LT Panel Board CPRI type test certified, indoor type of suitable size as per relevant IS, mounted on angle iron legs of size 50x50x6mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volts, 50HZ AC Supply, busbar chamber with aluminium busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25 mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed, Make of Panel Board : dvepl/aspl/tricolite/Siemen/Schneider (i) MCCB TP neutral link 415 volt 50 Hz, AC 125 Amps 36 KA with adjustable thermal magnetic release for over load & short circuit protection - 01 No as Panel Incomer. (ii) MCCB TP neutral link 415 volt 50 Hz, AC 25-100 Amps 16 KA with adjustable thermal magnetic release for over load & short circuit protection - 04 Nos.(iii) Star delta Starter 15 H.P. with, control relays, timers, auto/manual selector switch for suitable rating with ON, OFF, Trip Indicating Light, Push Buttons, Digital metering with CT/pt set, Control mcb etc. fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 01No. (iii) Star delta Starter 30 H.P. with, control relays, timers, auto/manual selector switch for suitable rating with ON, OFF, Trip Indicating Light, Push Buttons, Digital metering with CT/pt set, Control mcb etc. fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 01 No. (iv)Smart motor protection controller of dvepl make cat no. dvmpc163 protection or equivalent of ASPL/ Tricolite/Siemen/Schneider against auto phase polarity corrector, over voltage, under voltage, Phase loss, Phase unbalanced , Phase Asymmetry with On / Trip Indicating Light, auto reset with selectable on relay fitted in panel board - 02 set. |
| 148 | M&L for plain cemented concrete 1:2:4, type B2 ratio, in foundation/ filling and mass concrete complete all as specified and directed. |
| 149 | M&L brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement motor 1:3 cement to sand ratio complete all as specified and directed. |
| 150 | M&L for galvanised, corrugated mild steel sheeting, of thickness 0.80mm, with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 as in roof covering/ wall covering, fixed with self tapping screws complete all as specified. |
| 151 | M&L for plain, galvanised, mild steel sheeting, with grade of zinc coating 275, of thickness of 1 mm, including washers, joints, etc. as in roof covering/ wall covering, fixed with self tapping screws complete all as specified. |
| 152 | S&F GI water tubing 80mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and directed by Engr-in-Charge. |
| 153 | S&F GI water tubing 40mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and directed by Engr-in-Charge. |
| 154 | S&F GI water tubing 25mm bore \"medium grade\", galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and directed by Engr-in-Charge. |
| 155 | S&F 40mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipeand fixed complete all as specified and directed by Engr-in-Charge |
| 156 | S&F 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipeand fixed complete all as specified and directed by Engr-in-Charge |
| 157 | S&F cast iron non return valve 80mm, with flanged ends, with any fittings required all as specified and directed by Engr-in-Charge. |
| 158 | S&F XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 Volts grade , cross sectional area 95 Sqmm, 4 core complete all as specified and directed. |
| 159 | S&F on load change over switch 415 V in sheet metal enclosure 4 pole of capacity 125 Amps all as specified and directed by Engr-in-Charge. |
| 160 | S&F Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 50 KVA complete all as specified and directed. |
| 161 | Supply, installation, testing and commissioning of OEM manufactured, CPCB IV+ compliant, silent type Diesel Generator Set of capacity 50 kVA, rated 415 Volts, 3 Phase, 4 Wire, 50 Hz, 0.8 power factor, running at 1500 RPM, complete with acoustic enclosure, mounted on common MS base frame with AVM pads and inbuilt fuel tank, suitable for continuous operation under ambient conditions from –10°C to +40°C, complete all as specified and directed. The DG set shall conform to the latest editions of CPCB IV+ emission and noise norms,IS 8183/ BS 5514,ISO 3046,IS 10002,IS 13364 (Part 2):2003,IS 2147.Notes:- (i) The quoted rate shall be deemed to be inclusive of supply and laying of cables and terminations from the generator to the AMF panel, including making necessary openings in walls and making good all disturbed surfaces to match the existing finishes, complete all as specified and directed.(ii) The quoted rate shall be deemed to be inclusive of the first fill of lubricating oil and carrying out the final successful acceptance test.(iii) The quoted rate shall include excavation, removal of soft/hard soil, PCC, construction of cement concrete foundation, backfilling and mass concrete of Type B2 (1:2:4) using 40 mm graded aggregate, as per OEM drawings, for placement of the DG set, complete all as specified and directed.(iv) Factory inspection and testing of the DG set shall be carried out in the presence of the representative of the Accepting Officer, and all associated charges shall be borne by the contractor.(v) The contractor shall submit detailed technical specifications, approved model, make, drawings and OEM literature to the Accepting Officer for approval prior to placement of the order.(vi) The make of the DG set, switchgear, accessories and all items to be incorporated in the panel board shall be as specified in Schedule ‘A’ (List of Makes) or shall be got approved from the Accepting Officer on the drawings before placement of the order. |
| 162 | The DG set shall comprise: (A) Diesel Engine 4-stroke, turbocharged, water-cooled diesel engine conforming to CPCB IV+ emission and noise norms. The engine shall be of adequate BHP to deliver the rated 50 kVA output continuously, with 10% overload for one hour, as per ISO 3046 and installation, testing and commissioning of the DG set shall be carried out in accordance with IS 8183 and OEM recommendations complete with:i. Electric self-starting system with maintenance-free battery and charging alternatorii. Dry type air filter, fuel filters, lubricating oil filter and lubrication systemiii. Mechanical / electronic governor with frequency regulation within ±1%iv. Cooling system with radiator, fan, belts and water pumpv. Exhaust manifold with residential type silencer and flexible bellowsvi. Safety protections for low lube oil pressure, high water temperature and over-speedvii. Cold starting kit (B) Alternator Brushless, self-excited, self-regulated, copper-wound alternator, salient pole type, rated 50 kVA, 415 V ±1%, 3 Phase, 4 Wire, 50 Hz, star connected, insulation class ‘H’, temperature rise class ‘H’, drip-proof enclosure, conforming to IS/BS 5000 / BS 2613, complete with AVR and accessories.(C) Control Panel / AMF PanelFactory-built AMF control panel made of 2 mm thick CRCA sheet, dust and vermin proof, powder coated, suitable for 415 V, 3 Phase supply, complete with: (i). Copper bus bars rated at 1.5 times rated current (ii). 4-pole MCCB, contactors, fuses and internal copper wiring (iii). Microprocessor-based display for voltage, current, frequency, kW, kWh, PF, speed, battery voltage and engine parameters (iv). Indications and annunciations for low oil pressure, high water temperature, over-speed and battery low(v). Auto start/stop facility (automatic changeover beyond AMF panel in consumer’s scope |
| 163 | (D) Acoustic EnclosureOEM-manufactured, NAL/CPCB approved acoustic enclosure, fabricated from 1.6 mm thick CRCA sheet, powder coated after pre-treatment, composite construction, conforming to IS 2147, complete with:i. Sound insulation as per OEM normsii. Noise level not exceeding 75 dBA at 1 metre under free-field conditions as per IS 13364 (Part 2):2003iii. Internal LED lighting and external emergency stop push buttoniv. Batteries and control panel housed within enclosure on insulated platform(E) Exhaust, Foundation and MountingExhaust and fuel systems complete with all accessories as per OEM design and CPCB IV+ requirements, including exhaust silencer, flexible connections, insulation, fuel injection system, filters and hoses, suitable for safe, vibration-free operation of the DG set . RCC / PCC foundation of type B2 1:2:4 with using 40 mm graded stone aggregate as per OEM drawing, including excavation, PCC, mass concrete, backfilling and finishing complete. |
| 164 | M&L for earthing complete with galvanized steel earth plate electrode 60 cmx60cm x 6 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level ,using galvanised iron strip 32×6mm as earthing lead (as earth lead wire), by means of bolt, nuts, check nuts and washer of GI and earth wire protection by provision of GI medium grade pipe, 15mm bore including provn of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced XPM(weight not less than 4 kg/Sqm) and frame of angle iron 25x 25x 3 mm with lugs 2 nos and with 6 mm dia MS bar handle made to shape , GI medium 20 mm bore pipe for watering perforated at bottom 1.75mtr long placed on top edge of earth plate ,common salt and charcoal,fitting,test point with fixing arrangement , funnel ,wire mesh and earth work in any type of soil returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electric plate No 3 of SSR- 2009 Pt 1 and Connection to earth test point all as specified and testing on completion. Note:- Item of earthing includes the cost of 7.5m long galvanised iron earth lead wire and protection pipe of 15mm bore GI medium grade . |
| 165 | M&L for Point wiring for one light point/Ex/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi strand cable and 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi stranded cable (green colour) as earth lead in and including cable 1100 volts grade including 25mm casing and capping (ISI marked) for one light/ fan point controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with theexisting specification complete all as specified. |
| 166 | M&L for point wiring for 3 pin 5A socket outlet independent point controlled by one switch with 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi strand cable and 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi stranded cable (green colour) as earth lead, 1100 Volts grade including 25mm casing and capping (ISI marked) for one light/ fan point controlled by one switch including CI/MS sunk box of required size, & directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with theexisting specification complete all as specified. |
| 167 | M&L for point wiring for one 3 pin 15 Amps socket outlet/sheet metal enclosure independentwith 4.00 sqmm PVC insulated un-sheathed copper conductor single core multi strand cable and 2.5 sqmm PVC insulated un-sheathed copper conductor single core cable (green colour) as earth leadin and including 25mm PVC capping casing medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with theexisting specification complete all as specified. |
| 168 | S&F switch piano type flush 6 Amps Single pole one way complete all as specified and directed. |
| 169 | S&F switch socket combination 5 in 1, 5 and 15 Amps flush type universal controlled by one switch complete all as specified and directed. |
| 170 | S&F socket outlet 2 in1, 3 pin 5 Amps flush type complete all as specified and directed. |
| 171 | S&F of flame proof cum waterproof LED bulk head light fitting of 15W , IP 66 Protection of cast aluminium alloy material and heat and impact resistance toughen \"A\" clear glass having anti corrosiveepoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 172 | S&F in renewal for decorative LED batten for surface and pendant applications.Anodized extruded aluminium housing, high transmisitivity diffuser, high lumen output of VIVA MINI LED Luminaires (4FT) of20W connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 173 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep, minimum air delivery 210 CFMwith service value 6.00 BEE, five star rated with brushless direct current motor complete all as specified and directed. |
| 174 | S&F ceiling rose surface backelite 65x50mm two to threeterminal (ISI marked) complete all as specified and directed. |
| 175 | S&F MCB \"C\" series SPN 240V, 32 Amps all as specified and directed |
| 176 | S&F MCB \"C\" series SPN 240V, 6 to 32 Amps all as specified and directed. |
| 177 | S&F exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge |
| 178 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, cooper inding of sweep 300 complete all as specified and directed. |
| 179 | S&FRCBO for earth leakage, single pole and neutral (SPN) 30mA, 240V, 32 Amps all as specified and directed. |
| 180 | S&F sheet metal enclosure MCB distribution board. Single pole & neutral 240 Volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, to fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 181 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail