| 1 | Civil Work |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres |
| 3 | FLOORING BREAKING(for Slit): Dismantling carefully the existing serviceable tiles/slabs/clay tiles/Marble slab/granite slab/Kota stone/tandoor stone/Shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material out of hospital premises as directed by the Engineer-in-Charge. |
| 4 | Demolishing brick work/blockwork and plaster manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside ACTREC campus as per direction of Engineer-in-charge. |
| 5 | Construction |
| 6 | Providing & Fixing of the Aluminium fully Fixed windows as per the specification below, made out from Anodised Aluminium extrusions with 20-25 microns Anodizing. Special Grade EPDM rubber beading, Silicone Sealant of approved make and also with complete fitting at site with proper embedding in the structural framework. Required as per drawings and instructions of the Architects/ Consultants & all complete fitting at site. The Aluminium Frame shall weigh be more than 1.55Kg/m. All gaps between civil/structural work and aluminium frames shall be sealed and made watertight by applying silicone sealant and with good quality hardware and accessories like GI screws, Virgin PVC ,gaskets, silicon sealant on the periphery, as per detailed drawing etc. complete. All the section and design of ceiling shall be approved by Engineer in charge before the procurement of material. Providing and fixing Spacer Frame of approved make as per the instruction of Engineer in charge. Providing and fixing double glazed hermetically sealed glazing in aluminium ceiling, ventilators and partition etc. with 6 mm thick clear toughened float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. :Hot finished welded type tubes. |
| 8 | Providing and laying autoclaved aerated cement blocks masonry with 50-100 mm thick AAC blocks at all levels in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 9 | Supply and Fixing of Slim openable Aluminium door of 12mm thick Toughened Glass with designer etching including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle size 600mm Centre to Centre, lock and stopper etc. included in the item rate). as approved by Architect using sleek anodised aluminium section (anodising of approved colour) with complete glass of maximum dimension 3m or as per drawing. The Fixed glass to be fixed usingapproved Profiles of aluminium at Top & Bottom &at sides (the profile to shared for approval). The profile size to be 45x25MM to be fixed on to the floor/wall/ ceiling as per the architect design. The Profile shall be 20 micron matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness including 20 Micron of Anodizing of approved colour. All complete as per the instructions of Engineer in charge. |
| 10 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 12 | Providing and fixing PVC Designer false ceiling along with wooden pallete design mounted onheavy duty supporting grid as per manufacturers and approved specification including all necessary hardware fittings, fixtures, clips etc. fitted to allow for cutting, wastage and making openings for lighting fixtures, A/C grills etc. complete in all respect as per the specification and instruction of Engineer in charge. |
| 13 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18mm thick |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Providing and fixing of 2 sided double bolted Door handles, mortise lock and stoppers etc |
| 16 | Providing and laying Glazed vitrified floor/Dado tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800 x 1200 mm |
| 17 | Providing and fixing, in position concealed G.l. section for wall panelling using board of required thickness fixed on the \"W profile (0.55 mm thick) having a knurled web of 51.55 and two flanges of 26mm each with lips of 10.55mm placed @610mm c/c mm with thickness of 0.55 mm and web in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Multipurpose cement board reinforced with suitable fibre cement screw.8 mm thick cement fibre board, Type- B, Category- III as per IS 14862:2000 |
| 18 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2 coats |
| 19 | Providing and fixing of Aluminium pipe of size 100mm x 50mm with a thickness of 2mm having pre wood finished with not less than 50 microns wood grain Anodizing should be erected as vertical pillar as shown in pillar. The pillar shall be fixed on the ceiling with L-bracket/Cleats and on the floor should imbedded by cutting tiles inserting the section below and finishing the surface as per the instruction of Engineer in charge. |
| 20 | Providing & fixing onAcrylic Signages as per approval of EIC |
| 21 | Providing & fixing of logo back printed on frosted film on the door or where as instructed by EIC of size not less than 1000*1200 |
| 22 | ELECTRICAL WORKS |
| 23 | Supply & Fixing of following sizes of double door /recess type metal cladtriple pole and neutral distribution board with MCBs of 6 to 32 Amp per waycomplete with incoming MCB conforming with relevant specs.& drawings. |
| 24 | 12 way TPNDistribution board |
| 25 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCBof 12 ways/phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43Protection on provided iron/GI frame (horizontal busbar type) as per specification no.SW-MCBDB. |
| 26 | Supplying, erecting &marking FPMCB40A to63A, with rated short-circuitbreaking capacity (Icn)10kAC Curve in provided distribution board as per specification no.SW-MCB |
| 27 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB. |
| 28 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 29 | 12 way VTPN Distribution board for HVAC |
| 30 | Supplying & erecting triplepole andneutraldistribution board verticle (TPNDB), TP MCB of 12 ways/, with door, 1.2mm thickness surface/flushmounted, IP 43Protection on provided iron/GI frame (horizontal busbar type) asdirected by EIC ES |
| 31 | Providing & erecting 4 PoleMCCB,415V, upto100A, rated short-circuit breaking capacity 25 kA(Ics=100% ofIcu),adjustable thermal(overload) setting andfixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as |
| 32 | Supplying, erecting & marking TPMCB40A to63A, with rated short-circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB Type C Curve |
| 33 | Local Contol for HVAC |
| 34 | Supplying, erecting &marking FPMCB40A to63A, C Curvewith rated short-circuitbreaking capacity (Icn)10kA in provided enclosure board as directed by EIC ES |
| 35 | SITC of Enclosurebox metal type for 4 pole MCB including Gland and lugs |
| 36 | Supplying, erecting& terminatingFR XLPE insulated,galvanisedsteel wire armoured (round) cable 1100 V, 4 core4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe including glanding and connection for 12 nos end connections |
| 37 | MAIN & SUB MAIN CABLES/WIRING |
| 38 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3.5core 50 sq. mm. Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU for VTPNincluding gland ( 02 ) and lugs ( 08) |
| 39 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3.5core 25 sq. mm. Aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU for VTPNincluding gland ( 02 ) and lugs ( 08) |
| 40 | SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduitHeavy(HMS) as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire from main distribution board to power point circuits and lighting switchboard. |
| 41 | SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduitHeavy(HMS) as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire from main distribution board to power point circuits and lighting switchboard. |
| 42 | Point wiring |
| 43 | SITC of Primary point wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed including PVC conduit Heavy(HMS) / casing capping , with modular switch , modular plate,suitable GI box for concealled , suitable PVC box for surface, ceiling fan rose, PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 44 | SITCSecondary point wiring light to light looping with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed includingPVC conduit Heavy(HMS) / casing capping , with modular switch, modular plate,suitable GI box for concealled , suitable PVC box for surface, ceiling fan rose, PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 45 | POWER POINTS WITH WIRING |
| 46 | Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface orrecess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided.• All the power sockets inside and power panel insidewiring ferruling to be done as instructed by EIC ES |
| 47 | 3 Module |
| 48 | 6 Module |
| 49 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. |
| 50 | Modular switch 6A/16A |
| 51 | Modular Socket 6A/16A |
| 52 | Lighting |
| 53 | SITC of LED Tube lights of 4ft of 22watt / 24 watt including Ceiling junction box/ ceiling rose for light connection with metal clamping |
| 54 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt ) 15watt surface / concealed including ceiling rose / junction box PVC type with clamping Supplying, installation, Testing & Commissioning of LED Recessed/ surfaceDown lighter (Round/ square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI>80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below5%), life time (LED,Driver & electrical circuitary), of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shallbe confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. asrequired with . System lumen efficacy ≥105and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C) |
| 55 | SITC of 1200mm BLDC Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with BrushLess Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, suitable foroperation with regulator for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply,earthing including fan regulator 17 Nos to be fix in main switchboard etc. complete as req |
| 56 | Providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, |
| 57 | SITC of LED strip / ropelights 10watt to 15watt per meter, colour temp as directed by EIC ES LED Strip Light - 22 W - 2700 K - 60- 90 LED Density Per meter |
| 58 | SITC of LED strip light drivers6A to 10A as directed by EIS ES |
| 59 | SITC of alluminium profile housing for LED strip lights as directed by EIC ES |
| 60 | TELEPHONE & LAN WIRING |
| 61 | SITC of CAT 6 LAN cableSupply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cableto TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required. For telephone and data including RJ 45 Connector reqruied( 50 NOSfor connection at rack side and field side ) |
| 62 | SITC of CAT 6 fully loaded 24 port Patch Panel with cable management bar at rear side keystone jacks having the comliance with punch down tool and compliance / Certifications for ISO 9001:2015 & ROHS |
| 63 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON |
| 64 | SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS |
| 65 | Removing and refixing of existing electrical fixtures lightsfans ,LED ,fire alarm , IT fixtured and as directed by EIC ES and rerouting of existing wiring as directed by EIC ES |
| 66 | Fire alarm system |
| 67 | Supplying, installing, testing andcommissioning ofmicroprocessor basedintelligentaddressable main fire alarm panel,central processing unit with the2 loop capacity and capable of supporting not less than 250 devices and detectors per loop, with on-board LCD alphanumeric backlit display suitable for minimum80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 minutes in alarm condition, The panel shall have suitable provision for network connectivity & compatible for third partyintegration(Open Protocol to communicate) viaa MODBUS/BACNETinterface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacement warranty and inclusive of lifetime software license validity, as per specification no FF-AFAS/CP. |
| 68 | Supplying, installing, testing and commissioning of Addressable OpticalPhoto Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have single/twin bi- colour LED for 360 deg viewing. The detector is conforming toIS 2189: 2008,11360_1985_Reff2020_EN 54/VdS/ UL&FMapprovedwith3years equipment replacement warranty, Designed tomeet UL268, 7thEdition.FF- AFAS/SD |
| 69 | Supplying, installing, testing andcommissioning ofaddressable manual call points( break glass type/pull station type), made of addressable break glass plastic square inshapesurface/flushmountedwith\"Break Glass\"massage embeddedontheglass, complete erected with mountingbase andrequired accessories, Module shall conform toEN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP |
| 70 | Supplying, installing, testing and commissioning of AddressableSoundercumStrobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189:2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/ S-ST |
| 71 | Supplying, installing, testing and commissioning of addressable fire monitor modulefor flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitorpotential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM |
| 72 | Supply installation ofcable : 2 Core x 1.5 mm, Multistranded Copper, FRLS, Armoured cable, RED in Colour.The cable shall belaid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling. |
| 73 | Mic and speaker system |
| 74 | SUPPLY , INSTALLATION , TESTING AND COMMISSINING OF PUBLIC ANNOUNCEMENT SYSTEM WITH 04 MIC INPUT, USB, BT, AUX CONNECTION , LINE INPUT, 60 W |
| 75 | Supply and Installation of TABLE TOP MIC WITH Noise cancellation function.Single zone desktop paging microphone with a sturdy, aluminium die-cast top and special high reliability switches with integrated LED indicators. Fitted with a flexible 300mm (12”) gooseneck and a high quality unidirectional dynamic cartridge. |
| 76 | Supply installation of Speakar Loop and Signal cable : 2 Core x 1.5 mm, Multistranded Copper, FRLS, Armoured cable, RED in Colour.The cable shall belaid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling. |
| 77 | Supply and Installation of Ceilling Speaker 06w/03w/1.5 watt tapping |
| 78 | Air Cooled Split floor mounted Tower AC:Supply, Installation, testing and commissioning of floor standingtype tower air conditioning Unit as per following specification.Technology of Compressor: Non-Inverter/InverterCompressor: Scroll/Rotary ( 5 to 10 years warantee)Nominal Capacity: 4 TR ( Min 3.8 TR)Rated Voltage: 415 V, 3 Phase, 50 Hz, ACRefrigerant: R-32 or Eco-friendlyClassification by function: Cooling OnlyUnit Type: Single Split ( Single Indoor and Single Outdoor)Material of Evaporator & Condenser Coil: CopperMaterial of Fins: Aluminium with anti corrosion coatingMaterial of Filter : Synthetic Fiber ( Reusable)This shall include drilling holes in wall, core cutting in slab & finishing as required and as instructed by EIC. |
| 79 | Copper PipinG: Supply and installation of one pair (set) of copper tubing complete with supports between indoor & outdoor along with insulation sleeve as per suitable size duly wrapped with monsoon tap. All copper pipe shall be laid in perforated cable tray.Provision of GI/MS channel with cover duly painted to conceal the piping/wiring, as required |
| 80 | 9.5/15.9mm or as recommended by OEM |
| 81 | Copper Flexible Cable:Supply and installation of 4Cx 6 sqmm. PVC insulated copper cable, 1.1 KV grade in conduit/casing capping, |
| 82 | PVC drain Pipe:SITC PVC drain pipe Drain piping complete with all accessories with 6mm Nitrile Rubber Insulation. 25/32 mm |
| 83 | Removing, shifting and refixing of tower AC inclusing T&C along with gas charging |