| 1 | Dismantling of existing wooden floor-mounted switch and socket faceplates with associated back boxes, of different sizes, quantities 8-module 10 no. and 6-module5 no. also includingremoving of data-voice outlet faceplates, 2-port (15no.), along with dismantling conduits/raceway andassociated circuit wiring and CAT-6 cables, including cutting ofwooden floor complete in all respects, as directed by the Engineer-in-Charge. |
| 2 | Providing and fixingfollowing size Stainless Steel Cover Plate including fastener, screws as required ,complete in all respects, as per the direction of the Engineer-in-Charge. |
| 3 | 290mmX120mm |
| 4 | 230mmX120mm |
| 5 | 120mmX120mm |
| 6 | 2000mmx120mm |
| 7 | Supplying and laying of one number ISI marked PVC Insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on above false ceiling. |
| 8 | 4x16 sq.mm |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | 4 X 16 sq. mm (28mm) |
| 11 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 12 | Providing and fixing following rating and breaking capacity 4 poleMCCB with themoagnetic release,IS/IEC 60947-2 and terminal spreaders with MCCB enclosure sheet steelincluding drilling holes, duly factory painted as required, making connections, etc. as required |
| 13 | 100 A,30KA |
| 14 | Supplying & fixing following rating, 415 V, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required |
| 15 | 63 ATP&N |
| 16 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 17 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 18 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 19 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 20 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . |
| 21 | 4 way (4 + 12), Double door |
| 22 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 23 | 8 way , Double door |
| 24 | Supplying & fixing 5A to 32A rating, 240/415 V, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.. |
| 25 | Single pole |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 27 | 6 pin 15/16 A socket outlet |
| 28 | 15/16 A switch |
| 29 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 30 | 8 Module |
| 31 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 32 | 8 Module |
| 33 | 6 Module |
| 34 | 3 Module |
| 35 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 36 | Supplying and laying DLP PVC trunking system and accessories with Body Flexible cover Flat angle End cap for accommodating wire and power chord for aesthetics in specific areas complete as directed. (Acceptable make: Legrand). |
| 37 | Body without cover 80mm x 50 mm |
| 38 | Flexible cover width 40 mm |
| 39 | Flat angle |
| 40 | Clip on partition-Plastic |
| 41 | Body without cover 32mm x 16 mm |
| 42 | Flexible cover width 20 mm |
| 43 | Flat angle |
| 44 | Clip on partition-Plastic |
| 45 | Supplying,Installation,Testing & Commissioning of LEDRecessed/surfaceDown lighter (Round ) COB Type(System lumen efficacy ≥120lm/Watt )of following body material and construction as per IS : 10322withdriver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270Volt,frequency50/60 hz,Operating temp range-50Cto400C,internalsurgeprotectionof2.5KVwithShort&Open circuit protection ,THD < 10% ,P. F.≥0.95,IP20, CRI >80 , UGR (Unified GlareRating) < 19, Flicker free (flickershould be below 5%), life time (LED, Driver & electrical circuitry), lifetime of minimum50000 Burning Hours with,70%ofinitial Lumenmaintained tilllife ends , CCT3000°K(AsperANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption shouldnotmorethan the specified rating and Fixture shall be ofrelevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEMmusthaveitsowninhouseNABLlabsetupforalltestingfacilitiesforLED fixtures.\"completeinallrespecti/c external connectionswith1.5sqmmFRLS/HFFR, PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥120<135 lm/Watt output .LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submittedShape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermalmanagement:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast /Extruded aluminium Body including trim with Aluminium Reflector.Product shall be got approved by E-in-charge before supply that it fulfils the specification.warranty certificate shall be submitted. |
| 46 | 22 watt |
| 47 | Supplying, installation, Testing & Commissioning of Panellight 2x2 ft.(System lumen efficacy>135 lm/Watt), of following body material and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC140-270 Volt,frequency50/60hz,Operatingtemprange-50Cto40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95,IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver & electrical circuitry),of minimum50000 Burning Hours with , 70% of initial Lumenmaintained tilllife ends ,CCT 3000°K /4000°K /5700°K /6500°K(As perANSI Bin), SDCM(Standard Deviation Colour Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete inallrespecti/c external connectionswith1.5sq.mm FRLS/HFFR, PVC insulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy>135lm/Watt output . LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminiumBody (Thickness > 1.20 mm).Product shall be got approved by E-in-charge before supply that it fulfils the specification.warranty certificate shall be submitted. |
| 48 | 36 watt |