| 1 | Supplying and laying of 3.5 x 185 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 100 mm (ID) x 120 mm (OD) SN8 DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. |
| 2 | Supplying and laying of 3.5 x 95 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 100 mm (ID) x 120 mm (OD) SN8 DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. |
| 3 | Supplying and laying of 3.5 x 25 Sqmm aluminum conductor, PVC insulated, PVC sheathed, armored underground cable of 1.1 kV grade, conforming to IS 7098 standards, through 63 mm (ID) x 77 mm (OD)DWC HDPE pipe with proper socket coupling. The work includes excavation to a depth of up to 75 cm, laying of the cable with necessary protection, and refilling of the trench, complete in all respects as required. |
| 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.i)3.5 x 185 Sqmm (57 mm) |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.ii)3.5 x 95 Sqmm (45 mm) |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.iii)3.5 x 25 Sqmm (28 mm) |
| 7 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron,60 cm long and fixing the same in ground as required |
| 8 | SITC of cubical canopy type out door hut type Junction boxfrom 3 mm thick CRCA sheet having size 500 mm (L) x 350mm (D) x 500mm (H) fabricated with CRCA sheet 3 mm thick mounted on 04 Nos 50 mm x 50 mm x 6 mm thick angle iron frame, erected in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling,hinged front & back doors with locking arrangements,,cable tray with provision of fixing of glands at hte bottom,antirust design, air ventilation grooves, water drop proofing arrangement ,insluators,earthing studs,nuts bolts etc.as required including connections,painting with primer & finish paint with synthetic enamel paintwith04 nos aluminium bus bar strip suitable for 200 A,415 V capacity with suitable insulated support for AL bus bar complete as required. |
| 9 | Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 3 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm passivated gland plate, depth not less than 350 mm and all connection (incoming and out coming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50 mm x 50 mm x 6 mm angle iron frame with 800 mm 6 Nos long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1150 mm x 1850 mm x 450 mm as CPRI approvedNote:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Deptt.Incomeri) MCCB 04 Pole 200 Amp35/36 Ka , L frame,adjustable thermal and adjustable magnetic setting,- 02 nos with spreader terminalsii) MFM 4410 LCD Meter CL 1.0 WC441010OOOO 9425- 2 No.iii) SPD Type 2, 40KA, 3P + N AUSP023PN40 - 1 No iv)Residual Current Circuit Breaker (Model No - BG406330, 4 Pole, 63 Amp and Sensitivity 300 mA,- 2 Nov) CTs 200/5A, CL-1, 15 VA,Cast Resin for metering - 3 Nos.vi) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoingsi) MCCB 04 Pole 125 AmpFixed type 25Ka breaking cap.04 nosii) MCCB 04 Pole 63 AmpFixed type 16Ka breaking cap.02nos |
| 10 | Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 3 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied withsuitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 4 Nos 800 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1025 mm x 1250 mm x 450 mm as CPRI approved..Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department.Incomeri) MCCB 04 Pole 125 Amp25 Ka , L frame,adjustable thermal and adjustable magnetic setting,= 02 nos with spreader terminals ii) MFM 4410 LED Meter CL 1.0 WC441010OOOO 9425 - 1 No. iii)Residual Current Circuit Breaker (Model No - BG406330, 4 Pole, 63 Amp and Sensitivity 300 mA, - 2 Noiv) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoingsi) MCCB 04 Pole 63 AmpFixed type 16Ka breaking cap.= 03 nos with spreader terminals Incomer |
| 11 | Supplying, installation, testing and commissioning of indoor feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 3 mm thick CRCA sheet, Single door type with inbuilt locking arrangement, 3 mm passivated gland plate, depth not less than 350 mm and all connection (incoming and out coming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50 mm x 50 mm x 6 mm angle iron frame with 600 mm 6 Nos long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1500 mm x 1500 mm x 450 mm as CPRI approved.Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department.Incomer:i)On Load Changeover switch open execution type 04 Pole 320 Amp . 02 nosii)MCCB 04 Pole 250 Amp35-36 Ka , L frame,adjustable thermal and adjustable magnetic setting, 01 nos with spreaderiii)3 Phase Digital Ammeter CL-1.0 - 1 No. iv)3 PhaseDigital Voltmeter CL-1.0 - 1 No.ii) MFM 4410 LED Meter CL 1.0 WC441010OOOO 9425 - 1 No. v)CTs 200/5A, CL-1, 15 VA, Cast Resin for metering - 3 Nos.iv) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoingsi) MCCB 04 Pole 200 Amp35-36 Ka , L frame,adjustable thermal and adjustable magnetic setting,03 nos with spreaderii) MCCB 04 Pole 125 Amp 25 Ka breaking capacity , L frame, adjustable thermal and adjustable magnetic setting, 02 nos with spreader terminals |
| 12 | Fabrication supply installation and commissioning of CPRI approved outdoor type cubical canopy based Bus Bar Box with IP54 protection grade made up of 2.5 mm thick CRAC sheet done with 70 micron Powder Coating (RAL-7032) after 7 tank chemical pretreatment having 150 mm deep and 350 mm x 250 mm surface area excluding canopy with front openable door including suitable MS clamp for mounting on pole, nut bolts gasket and locking arrangements and Alluminum(E91E Grade) TP+N with Current Density 0.8A/sq. mm -100 Amps with suitable insulation support,6 way DIN Rail - 01 Nos, 16 AMPs DP MCB C series- 01 Nos, 6 AMPs SP MCB C series- 04 Nos and interconnection with 1.5 sqmm FRLS flexible copper cable etc as req. |
| 13 | Fabrication supply installation and commissioning of CPRI approved outdoor type cubical canopy based LED driver Box with IP54 protection grade made up of 3 mm thick CRAC sheet done with 70 micron Powder Coating (RAL-7032) after 7 tank chemical pretreatment having 250 mm deep and 600 mm x 400 mm surface area excluding canopy with front openable door,GI channel 2mm thick and 600 mm x 60 mm size for mounting of 03 Nos LED drivers including suitable GI clamp for mounting on pole, nut bolts gasket and locking arrangements with suitable insulation support and interconnection with 1.5 sqmm FRLS flexible copper cable etc as req. |
| 14 | Supply and erection of 10-meter-long hot dip galvanized octagonal pole with base plate fabricated in a single section.The pole shall be provided with brackets suitable for mounting three (03) LED floodlight luminaires. Each pole shall have two (02) holes of 18 mm diameter, symmetrically located on the bracket and pole, to facilitate entry of multicore wires.The pole shall be erected on a reinforced cement concrete (RCC) in Ratio 1:3:6for foundation withsteel reinforcement not less than 60 Kg andto ensure structural strength. Proper fixing shall be carried out using nuts, bolts, washers, and other accessories as required. Specificationsi) Pole Top Diameter: 100 mmii) Pole Bottom Diameter: 200 mmiii) Sheet Thickness: 4 mmiv) Base Plate Size: 320 mm × 320 mm × 20 mmv) Bracket for LED Fittings: Flanged type, 1300 mm long, fabricated from 100 × 100 × 6 mm GI channel, with three (03) mounting plates of size 250 × 175 × 5 mm thick, duly welded.vi) Cable Arrangement: Provision for three (03) inlet and outlet cables of size 3 × 1.5 sqmm for LED light connections.vii) Foundation Bolts: Four (04) nos. M24 × 850 mm bolts with nuts, washers, and plates, including connection and interconnection.viii) The pole shall be fixed using double nuts and installed complete in all respects. |
| 15 | Dismantling of 07/10 Mtr height tubular pole embedded in cement concrete foundation etc. as required |
| 16 | Installation of 01 Nos flood lights on the newly installed 10 Mtr tubular pole after Dismantling from existing 7 Mtr pole including suitable GI nut bolt & washer etc. as required |
| 17 | Supplying and drawing of 1.50 sq. mm 3 Core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 from top of the pole to the junction box |
| 18 | Earthing with GI earth earth pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclousure with cover plate having locking arrangement and watering pipe etc with charcoal coke and salt etc as required |
| 19 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 20 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connectionetc. as required. |
| 21 | Providing, laying and fixing 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. |
| 22 | Supplying and installing a 150-Watt, non-integral type LED flood light with warm white illumination (2700–3000 Kelvin) and IP66 protection rating, suitable for operation on a 230 Volt, 50 Hz supply. The unit is designed with a high power factor of ≥0.98, ensuring energy efficiency and stable performance, and operates reliably within a temperature range of 10°C to 75°C. It delivers superior luminous efficiency of >120 Lm/W, with a beam angle of 120° and a lifespan exceeding 50,000 working hours. The flood light maintains low total harmonic distortion (<10%) and is equipped with surge protection between 4 kV and 6 kV. The housing is constructed from pressure die-cast aluminum alloy for the gear compartment and extruded aluminum for the lamp body, providing excellent heat dissipation and durability. A minimum warranty of five years is included. The scope of work covers proper installation on the existing pole bracket, connection with 1.5 sqmm multicore wiring, and integration of the driver and light fittings, complete with all necessary accessories to ensure a fully functional setup. |
| 23 | Buyback of existing 7 Mtr height tubular pole, including bracket and Control gear box \"as is where is\" basis excluding switchgears, LED driver and other electrical accesories in control gear box, embedded in cement concrete foundation - weight approx- 70 Kg. vendors are advised to check the latest condition of poles on ground. |
| 24 | Buyback of existing 3.5 x 35 Sqmm / 3.5 x 25 Sqmm aluminum armored old underground (UG) cables from the excavated trench. The reopening of the trench for laying new 3.5 x 25 Sqmm aluminum cable to establish pole-to-pole connections, in accordance with Item No. 3 of the Estimate.Process Details:i) The old cable will first be disconnected from the existing poles.ii)The disconnected cable will then be retrieved from the excavated trench.iii)Lay the new 3.5 x 25 Sqmm aluminum cable in the trench, as specified under Item No. 3 of the Estimate.Special Conditions:i) Only cables of size 3.5 x 25 Sqmm and 3.5 x 35 Sqmm retrieved from the trench will be considered for buyback by the contractor.ii) Any cables of other sizes retrieved during excavation will be handed over to the department and will not be taken by the contractor. |