Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mt, in below type of pipeerected with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed. |
| 2 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 3 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 4 | (c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 5 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 6 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 7 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 8 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 9 | (h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 10 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 11 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 12 | Point wiring for independent PLUG with following size mains earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe erected complete with ISI marked 3 / 5 Pinsocket and tissino type switch erected with earth continuity connection erected onMetal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. |
| 13 | [A] For 6 amp plug and 6 amp switchwith 2-1.5 sq. mm Cu. Mains from near by switchboard/db board upto 6 mt. |
| 14 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 15 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 16 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 17 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 18 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 19 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 20 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 21 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 22 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 23 | (j) in existing pipe erected erected concealed inwall/ceiling complete |
| 24 | [B] 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from mcb d b boards. |
| 25 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 26 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 27 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 28 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 29 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 30 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 31 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 32 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 33 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 34 | (j) in existing pipe erected erected concealed inwall/ceiling complete |
| 35 | [C] 6/16A Plug and 16 A switch with 2-4 sq.mm Cu. Mains with 2.5 sq.mm ( green) earthing wire |
| 36 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 37 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 38 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 39 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 40 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 41 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 42 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 43 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 44 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 45 | (j) in existing pipe erected erected concealed inwall/ceiling complete |
| 46 | Point wiring for on board looped PLUG with tissino type single pole ISI marked Switch and Socket erected with necessary connections erected onwooden/Metal/ PVC Boxcovered with 3 mm thick PC(Polycarbonate) /Acrylic sheet for open / concealed wiring for following size. |
| 47 | [A] For 6 Amp. |
| 48 | [B] For 16 Amp. |
| 49 | Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type ofpipe to be erectedcomplete with earth continuity and necessary connection with primary light with accessories erected onMetal /PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheetfor open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. |
| 50 | Note:- Maximum up to 6 mtrs length, excess will be considered asMains for Secondary Point. |
| 51 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 52 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 53 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 54 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 55 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 56 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 57 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 58 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 59 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 60 | (j) in existing pipe erected erected concealed inwall/ceiling complete |
| 61 | Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in following type of pipe to be erected concealed in / flushed on wall / ceiling complete with 6A Tissino Type ISI marked accessories with earth continuity erected on Metal/PVC//Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed. |
| 62 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 63 | (b) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 64 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 65 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 66 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 67 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 68 | (g) with 16 swg(1.6 mm thick) HGS metal conduitpipe and accessories painted black erected concealed inwall/ceiling complete |
| 69 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 70 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 71 | (j) in existing pipe erected erected concealed inwall/ceiling complete |
| 72 | Point wiring for Light / Bell with2-1.5 sq.mm& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erectedwith 6A Modular type switch / bell push & accessories and earth continuityof following type, erected on PVC / Metallic/Wooden box, single mounting base framecovered with textured/metallic/white front plate modules erected on /in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. |
| 73 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 74 | Cat. I |
| 75 | Cat. II |
| 76 | Cat. III |
| 77 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 78 | Cat. I |
| 79 | Cat. II |
| 80 | Cat. III |
| 81 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 82 | Cat. I |
| 83 | Cat. II |
| 84 | Cat. III |
| 85 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 86 | Cat. I |
| 87 | Cat. II |
| 88 | Cat. III |
| 89 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 90 | Cat. I |
| 91 | Cat. II |
| 92 | Cat. III |
| 93 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 94 | Cat. I |
| 95 | Cat. II |
| 96 | Cat. III |
| 97 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 98 | Cat. I |
| 99 | Cat. II |
| 100 | Cat. III |
| 101 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 102 | Cat. I |
| 103 | Cat. II |
| 104 | Cat. III |
| 105 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 106 | Cat. I |
| 107 | Cat. II |
| 108 | Cat. III |
| 109 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 110 | Cat. I |
| 111 | Cat. II |
| 112 | Cat. III |
| 113 | Point wiring for FAN with 2-1.5 sq.mm& earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV GradeFRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipeerectedwith 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted andaccessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/whitefront plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. |
| 114 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 115 | Cat. I |
| 116 | Cat. II |
| 117 | Cat. III |
| 118 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 119 | Cat. I |
| 120 | Cat. II |
| 121 | Cat. III |
| 122 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 123 | Cat. I |
| 124 | Cat. II |
| 125 | Cat. III |
| 126 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 127 | Cat. I |
| 128 | Cat. II |
| 129 | Cat. III |
| 130 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 131 | Cat. I |
| 132 | Cat. II |
| 133 | Cat. III |
| 134 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 135 | Cat. I |
| 136 | Cat. II |
| 137 | Cat. III |
| 138 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 139 | Cat. I |
| 140 | Cat. II |
| 141 | Cat. III |
| 142 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 143 | Cat. I |
| 144 | Cat. II |
| 145 | Cat. III |
| 146 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 147 | Cat. I |
| 148 | Cat. II |
| 149 | Cat. III |
| 150 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 151 | Cat. I |
| 152 | Cat. II |
| 153 | Cat. III |
| 154 | Point wiring for Individual Plug with& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erectedcomplete with Modular type switch & 5 pin Plugerected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. |
| 155 | [I] For 6A Plug and 6 a switchwith 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board |
| 156 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 157 | Cat. I |
| 158 | Cat. II |
| 159 | Cat. III |
| 160 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 161 | Cat. I |
| 162 | Cat. II |
| 163 | Cat. III |
| 164 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 165 | Cat. I |
| 166 | Cat. II |
| 167 | Cat. III |
| 168 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 169 | Cat. I |
| 170 | Cat. II |
| 171 | Cat. III |
| 172 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 173 | Cat. I |
| 174 | Cat. II |
| 175 | Cat. III |
| 176 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 177 | Cat. I |
| 178 | Cat. II |
| 179 | Cat. III |
| 180 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 181 | Cat. I |
| 182 | Cat. II |
| 183 | Cat. III |
| 184 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 185 | Cat. I |
| 186 | Cat. II |
| 187 | Cat. III |
| 188 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 189 | Cat. I |
| 190 | Cat. II |
| 191 | Cat. III |
| 192 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 193 | Cat. I |
| 194 | Cat. II |
| 195 | Cat. III |
| 196 | [II] For 16A Plug and 16 amp switchwith 2-2.5 sq.mm Cu. Wire from mcb db board. |
| 197 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 198 | Cat. I |
| 199 | Cat. II |
| 200 | Cat. III |
| 201 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 202 | Cat. I |
| 203 | Cat. II |
| 204 | Cat. III |
| 205 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 206 | Cat. I |
| 207 | Cat. II |
| 208 | Cat. III |
| 209 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 210 | Cat. I |
| 211 | Cat. II |
| 212 | Cat. III |
| 213 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 214 | Cat. I |
| 215 | Cat. II |
| 216 | Cat. III |
| 217 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 218 | Cat. I |
| 219 | Cat. II |
| 220 | Cat. III |
| 221 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 222 | Cat. I |
| 223 | Cat. II |
| 224 | Cat. III |
| 225 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 226 | Cat. I |
| 227 | Cat. II |
| 228 | Cat. III |
| 229 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 230 | Cat. I |
| 231 | Cat. II |
| 232 | Cat. III |
| 233 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 234 | Cat. I |
| 235 | Cat. II |
| 236 | Cat. III |
| 237 | [III] For 16A Plug and 16 amp switchwith 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board. |
| 238 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 239 | Cat. I |
| 240 | Cat. II |
| 241 | Cat. III |
| 242 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 243 | Cat. I |
| 244 | Cat. II |
| 245 | Cat. III |
| 246 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 247 | Cat. I |
| 248 | Cat. II |
| 249 | Cat. III |
| 250 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 251 | Cat. I |
| 252 | Cat. II |
| 253 | Cat. III |
| 254 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 255 | Cat. I |
| 256 | Cat. II |
| 257 | Cat. III |
| 258 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 259 | Cat. I |
| 260 | Cat. II |
| 261 | Cat. III |
| 262 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 263 | Cat. I |
| 264 | Cat. II |
| 265 | Cat. III |
| 266 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 267 | Cat. I |
| 268 | Cat. II |
| 269 | Cat. III |
| 270 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 271 | Cat. I |
| 272 | Cat. II |
| 273 | Cat. III |
| 274 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 275 | Cat. I |
| 276 | Cat. II |
| 277 | Cat. III |
| 278 | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/whitefront plate modules erectedon/ in wall / ceiling with following type accessories |
| 279 | Cat. I |
| 280 | Cat. II |
| 281 | Cat. III |
| 282 | Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm& earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. |
| 283 | (a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete |
| 284 | Cat. I |
| 285 | Cat. II |
| 286 | Cat. III |
| 287 | (b) with 16 swg HGS metal conduitpipe and accessories painted black erected flushed on wall/ceiling complete |
| 288 | Cat. I |
| 289 | Cat. II |
| 290 | Cat. III |
| 291 | ( c) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete |
| 292 | Cat. I |
| 293 | Cat. II |
| 294 | Cat. III |
| 295 | (d) partial PVC pipe and drops in oval conduit / PVC casing capping erected flushed on wall/ceiling complete |
| 296 | Cat. I |
| 297 | Cat. II |
| 298 | Cat. III |
| 299 | (e) in existing pipe erected flushed on wall/ceiling complete |
| 300 | Cat. I |
| 301 | Cat. II |
| 302 | Cat. III |
| 303 | (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 304 | Cat. I |
| 305 | Cat. II |
| 306 | Cat. III |
| 307 | (g) with 16 swg HGS metal conduitpipe and accessories painted black. erected concealed inwall/ceiling complete |
| 308 | Cat. I |
| 309 | Cat. II |
| 310 | Cat. III |
| 311 | ( h) with oval conduit /PVC casing capping double lock type erected concealed inwall/ceiling complete |
| 312 | Cat. I |
| 313 | Cat. II |
| 314 | Cat. III |
| 315 | (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed inwall/ceiling complete |
| 316 | Cat. I |
| 317 | Cat. II |
| 318 | Cat. III |
| 319 | (j) in existing pipe erected concealed inwall/ceiling complete |
| 320 | Cat. I |
| 321 | Cat. II |
| 322 | Cat. III |
| 323 | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erectedwith necessary connections as per site situation directed by Engineer In charge. |
| 324 | (1)One No. SP 6 Amp. |
| 325 | Cat.I |
| 326 | Cat.II |
| 327 | Cat.III |
| 328 | (2) One No 5 pin plug |
| 329 | Cat.I |
| 330 | Cat.II |
| 331 | Cat.III |
| 332 | (3) Two Pin/RJ-11 Telephone Socket |
| 333 | [A] For One Gang |
| 334 | Cat.I |
| 335 | Cat.II |
| 336 | Cat.III |
| 337 | [B] For Two Gang |
| 338 | Cat.I |
| 339 | Cat.II |
| 340 | Cat.III |
| 341 | (4) TV Co-axial Socket outlet |
| 342 | Cat.I |
| 343 | Cat.II |
| 344 | Cat.III |
| 345 | (5) Electronic hum Free four or more steps EME Fan regulator |
| 346 | Cat.I |
| 347 | Cat.II |
| 348 | Cat.III |
| 349 | (6) Fuse units 10Amp. or 16 Amp. |
| 350 | Cat.I |
| 351 | Cat.II |
| 352 | Cat.III |
| 353 | (7) Blank Plate Single |
| 354 | Cat.I |
| 355 | Cat.II |
| 356 | Cat.III |
| 357 | (8)ComputerRJ-45 socket |
| 358 | Cat.I |
| 359 | Cat.II |
| 360 | Cat.III |
| 361 | (9) 16 Amp. SP one way switch |
| 362 | Cat.I |
| 363 | Cat.II |
| 364 | Cat.III |
| 365 | (10) 6/16Amp. Universal socket |
| 366 | Cat.I |
| 367 | Cat.II |
| 368 | Cat.III |
| 369 | (11) 6 Amps. Bell Push |
| 370 | Cat.I |
| 371 | Cat.II |
| 372 | Cat.III |
| 373 | (12) 6Amp. / 16 Amp. Two Way switch |
| 374 | Cat.I |
| 375 | Cat.II |
| 376 | Cat.III |
| 377 | (13) 6A/10A/16A/20A/25A/32A Single pole Modular MCB Switch |
| 378 | Cat.I |
| 379 | Cat.II |
| 380 | Cat.III |
| 381 | (14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole Modular MCB Switch |
| 382 | Cat.I |
| 383 | Cat.II |
| 384 | Cat.III |
| 385 | (15) 32 Amps. DP switch with Indicator |
| 386 | Cat.I |
| 387 | Cat.II |
| 388 | Cat.III |
| 389 | (16) 32 Amp. DP Main Switch Operating with Energy Key Tag |
| 390 | Cat.I |
| 391 | Cat.II |
| 392 | Cat.III |
| 393 | (17-a) For 400W / 450 watt One Module Electronic Dimmer |
| 394 | Cat. II |
| 395 | Cat. III |
| 396 | (17-b) For 600 / 650 watt Two module Electronic Dimmer |
| 397 | Cat. II |
| 398 | Cat. III |
| 399 | (17-c) For 1000 watt two module Electronic Dimmer |
| 400 | Cat. II |
| 401 | Cat. III |
| 402 | (18) 13 Amp. International Modular Socket |
| 403 | Cat.I |
| 404 | Cat.II |
| 405 | Cat.III |
| 406 | (19) Modular Indicating Call Bell |
| 407 | Cat.III |
| 408 | (20) Modular Buzzer |
| 409 | Cat.II |
| 410 | Cat.III |
| 411 | (21) Foot Light as per colour requirementwith concealed box, modular accessories, acrylic glass cover with suitable LED watt with all accessories as per following module |
| 412 | (a) Two modules Cat-III |
| 413 | (b) Four modules Cat-III |
| 414 | (c) Six modules Cat-III |
| 415 | (22) 16/20/25 Amp. Modular Starter for Motor / A.C. Unit Complete |
| 416 | Cat.II |
| 417 | Cat.III |
| 418 | (23) USB Charger with output of 5 V DC,2.1 A with inbuilt surge protection .cat-III |
| 419 | (24) Batten Holder/Angle Holder with modular frame withmetal ring Cat-III |
| 420 | Providing& erecting following type of Modular Type Accessories with necessary connection. As desired by Engineer In charge |
| 421 | (1) 6 Amp. SP one way switch |
| 422 | (2) 16 Amp. SP one way switch |
| 423 | (3) 6/16Amp. Universal socket |
| 424 | (4) 6 A socket |
| 425 | (5) LAN cable connector with ferule |
| 426 | Providing D type non rechargeable carbon zinc type Cell 1.5v of desired make suitable as demanded by engineer in charge evereday,panasonic,nippo make |
| 427 | Providing AA type 1.5 v non rechargeableCellof desired make as demanded by engineer in charge |
| 428 | (a)carbon-zinc evereday,panasonic,nippo make |
| 429 | (b)alkaline -Dura cell make |
| 430 | Providing AAA type 1.5 v Cell of desired make as demanded by engineer in charge |
| 431 | (a)carbon-zinc evereday,panasonic,nippo make |
| 432 | (b)alkaline -Dura cell make |
| 433 | Providing9v Cell of desired make as demanded by engineer in charge |
| 434 | (a)hiwatt/evereday/panasonic |
| 435 | (b) ultra alkaline -Dura cell make |
| 436 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed |
| 437 | (a)20 mm |
| 438 | (b) 25 mm |
| 439 | (c) 32 mm |
| 440 | (d) 40 mm |
| 441 | Providing & erecting approved make OVAL CONDUIT with necessary fittings fixed with adhesive solution and suitable clamps erectedon wall / ceiling of following size. |
| 442 | (1) 20 mm |
| 443 | (2) 25mm |
| 444 | Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. |
| 445 | (1) 20 mm |
| 446 | (2) 25 mm |
| 447 | (3) 32 mm |
| 448 | (4) 40 mm |
| 449 | (5) 50 mm |
| 450 | Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having double-locking arrangement with grooves, trunking of size not below 12.5 mm in height as per IS with accessories of PVC/Resin polypropylene not below 1.8 mm thick duly sealed in joint & erected on wall / ceiling of following size . |
| 451 | (1) 20 mm |
| 452 | (2) 25 mm |
| 453 | (3) 32 mm |
| 454 | (4) 40 mm |
| 455 | Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes |
| 456 | (1) 75 mm x 50 mm trunking |
| 457 | (2) 100 mm x 50 mm trunking |
| 458 | (3) 50 mm x 50 mm trunking |
| 459 | (4)100 mm x 50 mm trunking with TWIN compartmentWith clip in divider |
| 460 | Supply & installation of surface mountedU PVC snap-on adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with all accessories like removable covers, joints ,height spacer,angles complete with necessary bends, suitable sized junction boxes and tees etc, Complete. |
| 461 | (a)Size: 50x80mm PVC Raceways for Power & Data with 2 compartmentsabove specifications. |
| 462 | (b)Size: 50x130 mm PVC Raceways for Power & Data with 2 compartmentsabove specifications. |
| 463 | Providing & Erecting eight module pop up floor box/flushed with table surface Conform to IEC 60670-1, IEC 60670-23 & IEC 60884-1 with required items as demanded by engineer in charge with complete finishing .cat-III |
| 464 | Supply & installation of modular type accessories for U PVC snap-on adaptable trunking/Pop up Box with required items erectedwith necessary connection. As desired by Engineer In charge |
| 465 | i) 6 A SP 1 Way Switch cat-III |
| 466 | ii) 16ASP 1 Way Switch cat-III |
| 467 | iii) Bell Push 6 A SP 1 Way cat-III |
| 468 | iv) 6A universal socket shuttered cat-III |
| 469 | v) 6/16 A universal socket shuttered cat-III |
| 470 | vi) RJ-11 Telephone socket cat-III |
| 471 | vii) Cat-6 LAN Socket cat-III |
| 472 | Supplyingunder floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Jointsas required and demanded by engineer-incharge andlaying/erectingas per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) cat-III |
| 473 | [1] 50mm x 25mm x 1.6 mm with One Compartment |
| 474 | [2] 75mm x 25mm x 1.6 mm with One Compartment |
| 475 | [3] 100mm x 25mm x 1.6 mm with one compartment |
| 476 | [4] 225mm x 25mm x 1.6 mm with Three Compartment |
| 477 | [5] 250mm x 25mm x 1.6 mm with Three Compartments |
| 478 | [6] 300mm x 25mmx 1.6 mm with Three Compartments |
| 479 | [7] 50mm x 38mm x 1.6 mm with One Compartments |
| 480 | [8] 75mm x 38mm x 1.6 mm with one compartments |
| 481 | [9] 100mm x 38mm x 1.6 mm with One Compartments |
| 482 | [10] 150mm x 38mm x 1.6mm with Three Compartments |
| 483 | [11] 225mm x 38mm x 1.6mm with Three Compartments |
| 484 | [12] 250mm x 38mm x 1.6mm with Three Compartments |
| 485 | [13] 300mm x 38mm x 1.6 mm with Three Compartments |
| 486 | Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black surface/concealed of following size complete to be erected on/in wall or ceiling with erected with necessary saddles, screws, bends, junction boxes etc. with following (Nominal Bore) dia of pipes, in approved manner as directed |
| 487 | (1) 19/20 mm |
| 488 | (2) 25 mm |
| 489 | (3) 32 mm |
| 490 | (4) 38/40 mm |
| 491 | (5) 50 mm |
| 492 | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipeto be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size |
| 493 | (A) with medium class Rigid PVC pipe and accessories |
| 494 | (a) 2 wire 1.5 sq. mm |
| 495 | (b) 2 wire 2.5 sq. mm |
| 496 | (c) 3 wire 1.5 sq. mm |
| 497 | (d) 3 wire 2.5 sq. mm |
| 498 | (e) 4 wire 1.5 sq. mm |
| 499 | (f) 4 wire 2.5 sq. mm |
| 500 | (g) 6 wire 2.5 sq. mm |
| 501 | (B) with 16 swg HGS metal conduitpipe and accessories painted black. |
| 502 | (a) 2 wire 1.5 sq. mm |
| 503 | (b) 2 wire 2.5 sq. mm |
| 504 | (c) 3 wire 1.5 sq. mm |
| 505 | (d) 3 wire 2.5 sq. mm |
| 506 | (e) 4 wire 1.5 sq. mm |
| 507 | (f) 4 wire 2.5 sq. mm |
| 508 | (g) 6 wire 2.5 sq. mm |
| 509 | (C) with oval conduit /PVC casing capping double lock type |
| 510 | (a) 2 wire 1.5 sq. mm |
| 511 | (b) 2 wire 2.5 sq. mm |
| 512 | (c) 3 wire 1.5 sq. mm |
| 513 | (d) 3 wire 2.5 sq. mm |
| 514 | (e) 4 wire 1.5 sq. mm |
| 515 | (f) 4 wire 2.5 sq. mm |
| 516 | (g) 6 wire 2.5 sq. mm |
| 517 | (D) partial PVC pipe and drops in oval conduit / PVC casing capping |
| 518 | (a) 2 wire 1.5 sq. mm |
| 519 | (b) 2 wire 2.5 sq. mm |
| 520 | (c) 3 wire 1.5 sq. mm |
| 521 | (d) 3 wire 2.5 sq. mm |
| 522 | (e) 4 wire 1.5 sq. mm |
| 523 | (f) 4 wire 2.5 sq. mm |
| 524 | (g) 6 wire 2.5 sq. mm |
| 525 | (E) in existing pipe |
| 526 | (a) 2 wire 1.5 sq. mm |
| 527 | (b) 2 wire 2.5 sq. mm |
| 528 | (c) 3 wire 1.5 sq. mm |
| 529 | (d) 3 wire 2.5 sq. mm |
| 530 | (e) 4 wire 1.5 sq. mm |
| 531 | (f) 4 wire 2.5 sq. mm |
| 532 | (g) 6 wire 2.5 sq. mm |
| 533 | providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size |
| 534 | (A) with medium class Rigid PVC pipe and accessories |
| 535 | (a) 2 wire 4 sq. mm |
| 536 | (b) 2 wire 6 sq. mm |
| 537 | (c) 2 wire 10 sq. mm |
| 538 | (d) 3 wire 4 sq. mm |
| 539 | (e) 3 wire 6 sq. mm |
| 540 | (f) 3 wire 10 sq. mm(use earth wire of 4 sq.mm ) |
| 541 | (g) 4 wire 4 sq. mm |
| 542 | (h) 4 wire 6 sq. mm |
| 543 | (i)4 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 544 | (B) with 16 swg HGS metal conduitpipe and accessories painted black. |
| 545 | (a) 2 wire 4 sq. mm |
| 546 | (b) 2 wire 6 sq. mm |
| 547 | (c) 2 wire 10 sq. mm |
| 548 | (d) 3 wire 4 sq. mm |
| 549 | (e) 3 wire 6 sq. mm |
| 550 | (f) 3 wire 10 sq. mm(use earth wire of 4 sq.mm ) |
| 551 | (g) 4 wire 4 sq. mm |
| 552 | (h) 4 wire 6 sq. mm |
| 553 | (i)4 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 554 | (C) with oval conduit /PVC casing capping double lock type |
| 555 | (a) 2 wire 4 sq. mm |
| 556 | (b) 2 wire 6 sq. mm |
| 557 | (c) 2 wire 10 sq. mm |
| 558 | (d) 3 wire 4 sq. mm |
| 559 | (e) 3 wire 6 sq. mm |
| 560 | (f) 3 wire 10 sq. mm(use earth wire of 4 sq.mm ) |
| 561 | (g) 4 wire 4 sq. mm |
| 562 | (h) 4 wire 6 sq. mm |
| 563 | (i)4 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 564 | (D) partial PVC pipe and drops in oval conduit / PVC casing capping |
| 565 | (a) 2 wire 4 sq. mm |
| 566 | (b) 2 wire 6 sq. mm |
| 567 | (c) 2 wire 10 sq. mm |
| 568 | (d) 3 wire 4 sq. mm |
| 569 | (e) 3 wire 6 sq. mm |
| 570 | (f) 3 wire 10 sq. mm(use earth wire of 4 sq.mm ) |
| 571 | (g) 4 wire 4 sq. mm |
| 572 | (h) 4 wire 6 sq. mm |
| 573 | (i)4 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 574 | (E) in existing pipe |
| 575 | (a) 2 wire 4 sq. mm |
| 576 | (b) 2 wire 6 sq. mm |
| 577 | (c) 2 wire 10 sq. mm |
| 578 | (d) 3 wire 4 sq. mm |
| 579 | (e) 3 wire 6 sq. mm |
| 580 | (f) 3 wire 10 sq. mm(use earth wire of 4 sq.mm ) |
| 581 | (g) 4 wire 4 sq. mm |
| 582 | (h) 4 wire 6 sq. mm |
| 583 | (i)4 wire 10 sq. mm (use earth wire of 4 sq.mm ) |
| 584 | providing and erecting Mains with ISI marked electrolyte stranded copper conductor, Non PVC Zero Halogen free fire retardant insulated copper conductor,insulated wire (HRFR) conforms to IS-694, erected in existing pipe with 1.5sq. mm copper conductor of same specifications for earth continuity of following size. |
| 585 | [a] 2wire 0.75 sq.mm (w/o ECC) |
| 586 | [b] 2 wire 1.0 sq.mm (w/o ECC) |
| 587 | [c] 2 wire 1.5 sq.mm |
| 588 | [d] 2 wire 2.5 sq.mm |
| 589 | [e] 2 wire 4.0 sq.mm |
| 590 | [f] 2 wire 6.0 sq.mm |
| 591 | [g] 2 wire 10.0 sq.mm |
| 592 | [h] 3 wire 1.0 sq.mm |
| 593 | [i] 3 wire 1.5 sq.mm |
| 594 | [j] 3 wire 2.5 sq.mm |
| 595 | [k] 3 wire 4.0 sq.mm |
| 596 | [l] 4 wire 1.0 sq.mm |
| 597 | [m] 4 wire 1.5 sq.mm |
| 598 | [n] 4 wire 2.5 sq.mm |
| 599 | [o] 4 wire 4.0 sq.mm |
| 600 | providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. |
| 601 | (a) One wire 1.00 sq. mm |
| 602 | (b) One wire 1.50 sq. mm |
| 603 | (c) One wire 2.50 sq. mm |
| 604 | (d)One wire 4.00 sq. mm |
| 605 | (e)One wire 6.00 sq. mm |
| 606 | (f) One wire 10.00 sq. mm |
| 607 | (g) One wire 16.00 sq. mm |
| 608 | (h) One wire 25.00 sq. mm |
| 609 | (i)One wire 35.00 sq. mm |
| 610 | (j)One wire 50.00 sq. mm |
| 611 | (k) One wire 70.00 sq. mm |
| 612 | (l)One wire 95.00 sq. mm |
| 613 | (m) One wire 120.00 sq. mm |
| 614 | (n) One wire 150.00 sq. mm |
| 615 | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed. |
| 616 | a) 0.75 Sq.mm twin twisted |
| 617 | b) 1.00 Sq.mm twin twisted |
| 618 | c) 1.00 Sq.mm 2 core round/ flat PVC sheathed |
| 619 | d) 1.50 Sq.mm 2 core round PVC sheathed |
| 620 | e) 1.50 Sq.mm 3 core round PVC sheathed |
| 621 | f) 1.50 Sq.mm 4 core round PVC sheathed |
| 622 | g) 2.50 Sq.mm 2 core round PVC sheathed |
| 623 | h) 2.50 Sq.mm 3 core round PVC sheathed |
| 624 | i) 2.50 Sq.mm 4 core round PVC sheathed |
| 625 | j) 4.00 Sq.mm 3 core round PVC sheathed |
| 626 | k) 4.00Sq.mm 4core round PVC sheathed |
| 627 | Providing& erecting Switchboard for Computer or electric apparatus consisting offollowing modular type accessories mounted withPVC/ Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed1 no. 6A/16A universal plug-switchcombined.3 nos. 6A Switch3 nos. 6A 5 pin Plug |
| 628 | For Modular Type Accessories |
| 629 | Cat. II |
| 630 | Cat. III |
| 631 | Bakelite adopter for Holder to be erected. |
| 632 | Starter for 20 watts / 40 watts fluorescent tube. |
| 633 | Hanging bed switch / Bell push 5A erected on existing flexible wire. |
| 634 | 5A, 10 way bakelite connector duly erected on existing board. |
| 635 | 15A. 10 way bakelite connector duly erected on existing board. |
| 636 | Providing & erecting ISI marked 3 pin plug top. |
| 637 | (a) for 5/6 A., 240 V |
| 638 | (b)for 15/16A, 240 V |
| 639 | Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery |
| 640 | Supplying electrical insulation L.T. Tape role with ISI marked having nominal width 1.8 cms nominal length 9.0 mtr nominal thickness 0.125 mm and having self adhesive PVC |
| 641 | Providing & erecting insulated socket 3P+N+E with Plug16A rating which is comprised of Four pole MCB slot and insulated socket IP40 cat-III |
| 642 | Providing & erecting insulated socket 3P+N+E with Plug 32A rating which is comprised of Four pole MCB slot and insulated socket IP40 cat-III |
| 643 | Approved make CFL Retrofit5 / 7 / 9 /11 Watt, erected if required |
| 644 | Cat.I |
| 645 | Cat.II |
| 646 | Cat.III |
| 647 | Approved make C.F.L. Retrofit13/15/18 Watt erected if required |
| 648 | Cat.I |
| 649 | Cat.II |
| 650 | Cat.III |
| 651 | Approved make C.F.L.Retrofit20 / 23 / 25 / 26Watt. erected if required |
| 652 | Cat.I |
| 653 | Cat.II |
| 654 | Cat.III |
| 655 | Approved make C.F.L.Retrofit of following size erected if required |
| 656 | [A] 35/36 Watt |
| 657 | Cat.I |
| 658 | Cat.II |
| 659 | Cat.III |
| 660 | [B] 40/45 Watt |
| 661 | Cat.I |
| 662 | Cat.II |
| 663 | Cat.III |
| 664 | [C] 55/65/85 Watt |
| 665 | Cat.I |
| 666 | Cat.II |
| 667 | Cat.III |
| 668 | Approved make CFL. Non-Retrofit9/11 Watterected if required |
| 669 | Cat.I |
| 670 | Cat.II |
| 671 | Approved make CFL. Non-Retrofit 13 /15 / 18 Watt erected if required |
| 672 | Cat.I |
| 673 | Cat.II |
| 674 | Cat.III |
| 675 | Approved make C.F.L.Non-Retrofit 35 / 36 Watt erected if required |
| 676 | Cat.I |
| 677 | Cat.II |
| 678 | Cat.III |
| 679 | Approved make Spiral Retrofit CFL. for BC/ Screw Type Holder of following size erected if required |
| 680 | [a] 15/20/23/27 Watt |
| 681 | Cat.II |
| 682 | Cat.III |
| 683 | [b] 35 / 36 Watt |
| 684 | Cat.II |
| 685 | Cat.III |
| 686 | [c] 65/50 Watt. |
| 687 | Cat.II |
| 688 | Cat.III |
| 689 | Approved make CFL. Ballast Having P.F. above 0.95 (Adopter) 9/11/13/15/18 Watt erected if required |
| 690 | Cat.I |
| 691 | Cat.II |
| 692 | Cat.III |
| 693 | Approved make CFL. Ballast Having P.F.above 0.95 for 20 watt up to 86 watt erected if required |
| 694 | Cat.I |
| 695 | Cat.II |
| 696 | Cat.III |
| 697 | Providing and erecting decorative wall bracket fittings complete with LED lamp and rust free fittings components mounted in chrome finish housing with holder ,clear/opaque glass diffuser complete erected with lead wires with minimum 15 wattage capacity as per instruction engineer incharge/architect/authority .cat-III |
| 698 | Supplying and erecting approved make of tube fitting with One no T-5 tube24/ 28 Wwith Electronic ballast with each tube separately THD less than 10 & built in adaptors, GI / PVC housing & mirror optic reflector, suitable to work on 120V - 300V, A.C. supply with connector and adapter if required. [Make of fitting & tube may be differ& fitting shall be providing with tube] |
| 699 | Cat II |
| 700 | Cat III |
| 701 | Supply of approved make lumilux triphospher T-5 tube suitable to operate on 120V - 300 V of |
| 702 | (A) 14 Watt |
| 703 | Cat I |
| 704 | Cat II |
| 705 | Cat III |
| 706 | (B) 24Watt / 28 watt |
| 707 | Cat I |
| 708 | Cat II |
| 709 | Cat III |
| 710 | Supplying & erecting energy saving Energy Efficient E+ (1 -4 ft) 28 watt retrofit tube fitting with one no 28watt T-5 tube complete with E.G.P. wings reflector / clear acrylic guard cover & tubeand electronic inbuilt circuit ballast of rating 130 to 325 V A.C. The fittings should be able to fit in any conventional existing T - 8 tube fittings complete erected in an approved manner. |
| 711 | Repairing of any brand of T-5 Indoor or Outdoor type Tube fitting of any nos of T -5 tubesby replacing the electrical components like Resistance, Diode, Capacitor, Transistor, SCR tube side holder, small transformer and other any part and put the same in working condition as original on site /work shop with re-erection if required. (Rates excluding tube cost) |
| 712 | Cat.I |
| 713 | Cat.II |
| 714 | Cat.III |
| 715 | Outdoor street light fitting side entry with clear acrylic /plastic / polystyrene cover complete with starter, polyester choke copper wound complete erected with 40/36 watt tube holders. with lead wire and connections. |
| 716 | (a) With 1 tube 40 watt.120 cms |
| 717 | Cat.I |
| 718 | Cat.II |
| 719 | Cat.III |
| 720 | (b) with 2 tube 40 watt.120 cms. |
| 721 | Cat.I |
| 722 | Cat.II |
| 723 | Cat.III |
| 724 | (A) Providing 45 to 50 cms. 16 SWG conduit pipe down rod white painted with ball sockets and nipple for suspension of fluorescent fitting complete erected with lead wires. |
| 725 | (B) Extra for every additional 100 mm. long double down rod. |
| 726 | Providing & erecting 14 SWG galvanized mild steel chain with end rings for hanging tube fitting as directed. |
| 727 | Shock proof hand lamp with wire guard and 3 mtr of 3 core round flexible wire of suitable size and 3 pin plug top and heavy duty pendant holder |
| 728 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die castpowder coated and high U.V. & corrosion resistancewith diffuserwith company mark/name 160V to 270 V, Power Factor more than 0.95, THD < 15 %,CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) |
| 729 | (A) Tube Light with integral driver |
| 730 | (i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet |
| 731 | Cat-ll |
| 732 | Cat-lll |
| 733 | (ii) 12-14 Watts, Surge-2 KV, IP-20, conventional 4 feet |
| 734 | Cat-ll |
| 735 | Cat-lll |
| 736 | (iii) 18-20 Watts, Surge - 2KV, IP-20, conventional 4 feet |
| 737 | Cat-ll |
| 738 | Cat-lll |
| 739 | (iv) 22-24 Watts, Surge - 2KV, IP-20, conventional 4 feet |
| 740 | Cat-ll |
| 741 | Cat-lll |
| 742 | (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet |
| 743 | Cat-ll |
| 744 | Cat-lll |
| 745 | Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge protection, Polycarbonate diffuser, mounting suitable for E14/E27/B22 lamp holders, pf>=0.5 |
| 746 | (A) LED Lamps integral type, with PC diffuser suitableLAMP holder |
| 747 | (i)2 to 3 watts |
| 748 | Cat-II |
| 749 | Cat-III |
| 750 | (ii)5 to 8 watts |
| 751 | Cat-II |
| 752 | Cat-III |
| 753 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die castpowder coated and high U.V. & corrosion resistancewith diffuserhoused in aluminium casted body with company mark/name 160V to 270 V,Power Factor more than 0.9, THD < 15 %,CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) |
| 754 | (A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 |
| 755 | (i) 5-9 watts,Surge-2 KV |
| 756 | Cat-ll |
| 757 | Cat-lll |
| 758 | (ii) 11-15 watts, Surge-2 KV |
| 759 | Cat-ll |
| 760 | Cat-lll |
| 761 | (iii) 16-20 watts, Surge-2 KV |
| 762 | Cat-ll |
| 763 | Cat-lll |
| 764 | (iv) 22-24 watts, Surge-2 KV |
| 765 | Cat-ll |
| 766 | Cat-lll |
| 767 | (B) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.IP20 |
| 768 | (i)up to 8 Watts,4\" x 4\", Surge-2 KV |
| 769 | Cat-ll |
| 770 | Cat-lll |
| 771 | (ii) 10 watts, 4\" x 4\", Surge-2 KV |
| 772 | Cat-ll |
| 773 | Cat-lll |
| 774 | (iii) 12-15 watts, 6\" x 6\", Surge-2 KV |
| 775 | Cat-ll |
| 776 | Cat-lll |
| 777 | (iv) 18 to 20 watts, 8\" x 8\", Surge- 2 KV |
| 778 | Cat-ll |
| 779 | Cat-lll |
| 780 | (v) 24 watts, 12\" x 12\" , Surge-2 KV |
| 781 | Cat-ll |
| 782 | Cat-lll |
| 783 | (vi)36 watts, 24\" x 24\" mm, Surge- 2KV |
| 784 | Cat-ll |
| 785 | Cat-lll |
| 786 | (vii) from 45 to 48 watts, 24\" x 24\", Surge-2 KV |
| 787 | Cat-ll |
| 788 | Cat-lll |
| 789 | D )LED Strip Light |
| 790 | (i) Minimum 4.8W-120 LED per meter (2 wire, IP-65) with non integral suitable Driver complete |
| 791 | Cat-ll |
| 792 | Cat-lll |
| 793 | (ii) Minimum 7.2W -240 LED per meter,(2 wire, IP-65) with non integral suitable Driver complete |
| 794 | Cat-ll |
| 795 | Cat-lll |
| 796 | (E) Under Water Light,12V DC including Driver,IP-67 with die-cast/deep drawn housing with impact resistance clear toughened glass. |
| 797 | (i) 5-8 watts |
| 798 | Cat-ll |
| 799 | Cat-lll |
| 800 | (ii) 12 watts |
| 801 | Cat-ll |
| 802 | Cat-lll |
| 803 | (F) Spot Light425 Lumens, Surge-2KV |
| 804 | (i) 3 to 7 Watts |
| 805 | Cat-ll |
| 806 | Cat-lll |
| 807 | (ii) 8 to 11 Watts |
| 808 | Cat-ll |
| 809 | Cat III |
| 810 | (G) StepLight havingAluminium die cast and ABS Plastic material. |
| 811 | (i)5 watts, Direct/Indirect luminaire |
| 812 | Cat-ll |
| 813 | Cat-lll |
| 814 | (H) Mirror Light 9 Watts, wall mounted minimum 1 feet long |
| 815 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) |
| 816 | (A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over voltage protection. |
| 817 | (i) 10 to 12 Watts |
| 818 | Cat-ll |
| 819 | Cat-lll |
| 820 | (ii) 15 to 24 Watts |
| 821 | Cat-ll |
| 822 | Cat-lll |
| 823 | (iii) above 24 to 36 watts |
| 824 | Cat-ll |
| 825 | Cat-lll |
| 826 | (B) Flood Light (IP-65), Surge protection-4KV integral and,Light must have 440VAC line supply with over-voltage protection. |
| 827 | (i) above 20 to 30 watts |
| 828 | Cat-ll |
| 829 | Cat-lll |
| 830 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %. (fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) |
| 831 | (A) Street Light (IP-65), Surge protection -4KV integral and , Light must have 440VAC line supply with over-voltage protection. |
| 832 | (i) above 36 to 48 watts |
| 833 | Cat-ll |
| 834 | Cat-lll |
| 835 | (ii) above 48 to 60 Watts |
| 836 | Cat-ll |
| 837 | Cat-lll |
| 838 | (iii) Above 60 watts to 90 watts |
| 839 | Cat-ll |
| 840 | Cat-lll |
| 841 | (iv) above 90 to 120 watts |
| 842 | Cat-ll |
| 843 | Cat-lll |
| 844 | (v) above 120 watts to 160 watts |
| 845 | Cat-ll |
| 846 | Cat-lll |
| 847 | (vi) above 160 watts to 200 watts |
| 848 | Cat-ll |
| 849 | Cat-lll |
| 850 | (vii) above 200 to 250 watts |
| 851 | Cat-ll |
| 852 | Cat-lll |
| 853 | (B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. |
| 854 | (i) above 40 to 48 watts |
| 855 | Cat-ll |
| 856 | Cat-lll |
| 857 | (ii) above 48 to 60 Watts |
| 858 | Cat-ll |
| 859 | Cat-lll |
| 860 | (iii) Above 60 watts to 90 watts |
| 861 | Cat-ll |
| 862 | Cat-lll |
| 863 | (iv) above 90 to 120 watts |
| 864 | Cat-ll |
| 865 | Cat-lll |
| 866 | (v) above 120 to160 watts |
| 867 | Cat-ll |
| 868 | Cat-lll |
| 869 | (vi) above 160 to 200 watts |
| 870 | Cat-ll |
| 871 | Cat-lll |
| 872 | (vii) above 200 to 250 watts |
| 873 | Cat-ll |
| 874 | Cat-lll |
| 875 | (C) Post Top Lantern LED fitting comprises of finish cast aluminum spigot and spun aluminum canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting driver and accessories wired upto terminal block.IP 65 |
| 876 | (i) 20- 30W |
| 877 | Cat-ll |
| 878 | Cat-lll |
| 879 | (ii) 32-40W |
| 880 | Cat-ll |
| 881 | Cat-lll |
| 882 | Bollards |
| 883 | (a) LED Bollard fittings of minimum height 400 mm & dia.100mm having polycarbonateclear/milky diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160mm with erection by M8x75mm fastner with required RCC foundation.IP65 for 9 to 20 watt,surge-4kv cat-III |
| 884 | (b) LED Bollard fittings of minimum height 600 mm & dia.100mm having polycarbonateclear/milky diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160mm with erection by M8x75mm fastner with required RCC foundation.IP65 for 9 to 20 watt,surge-4kv- cat-III |
| 885 | (c) LED Bollard fittings of minimum height 1000 mm & dia.100mm having polycarbonateclear/milky diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160mm with erection by M8x75mm fastner with required RCC foundation.IP65 for 9 to 20 watt and above ,surge-4kv cat-III |
| 886 | providing and erecting PVC body surface or pendent mounting LED Bulk type 9 watt Lighting Fitting with electronic driver. And lumen output from luminaire 720lm , input voltage range 90-300VAC , 50Hz cool white(3000 to 6500k), inbuilt driver, -20degC to +60degC working temperature, AL frame with Beam Angle 120deg |
| 887 | Supplying and Erecting Of L.E.D. type High bay fixture having Power Consumption of following watts with,Input Voltage 110 - 290 V.AC with full efficiency, Power Factor > 0.9 with 50/60 HZ, CCVC LED Driver used for maximum power saving, Best Quality Aluminium alloy housingand aluminium Dome for better heat dissipation, CCT Cool white (6000K), CRI 80, Beam angle > 120 degrees, working temperature -20 deg c to +55 deg c, Body IP 65 |
| 888 | (A) 70 to 90 watts |
| 889 | (B) 90 to 150 watts |
| 890 | (C) 150 to 200 watts |
| 891 | supplying LED Portable/Rechargeable flood light having die - cast aluminium enclosure designed for maximum thermal efficiency of 130lm luminous efficiency at voltage supply between 140-270V AV/12V DC at operating temperature of -20 degree to 60degree celcius with battery back up 3-4hrs |
| 892 | (A) up 10 Watt |
| 893 | (B) 11 to 20 watt |
| 894 | (C) 21 to 30 watt |
| 895 | Repairing of existingindoor LED light fixture(tube light/panel light/spot light/strip light/decorative wall lights etcas per sample) by suitable driver 2 kv according to LED PCB as per requirement of following rating wattage capacity . |
| 896 | (A)1-3 watt capacity |
| 897 | (B)4-6 watt capacity |
| 898 | (C)8-15 watt capacity |
| 899 | (D)16-24 watt capacity |
| 900 | (E)25-36 watt capacity |
| 901 | (F)38-50 watt capacity |
| 902 | Repairing of existingindoor LED light fixture(flood light/street light/bollard lights/decorative wall lights/landscape light etcas per sample )by suitable driver 4 kv,IP65according to LED PCB as per requirement of following rating wattage capacity . |
| 903 | (A)1-3 watt capacity |
| 904 | (B)4-6 watt capacity |
| 905 | (C)8-15 watt capacity |
| 906 | (D)16-24 watt capacity |
| 907 | (E)25-36 watt capacity |
| 908 | (F)38-48 watt capacity |
| 909 | (G)50-80 watt capacity |
| 910 | (H)90-100 watt capacity |
| 911 | providing and erecting Approved make Double Pole Plastic Switch and fuse 250V., 30A confirming to IS erected on Polished wooden block as directed. |
| 912 | Providing Approved makeDouble Pole Cast Iron Clad Switch & rewirable Fuse 240 /250 V confirming to IS. |
| 913 | (a)16A. |
| 914 | Cat.I |
| 915 | Cat.II |
| 916 | Cat.III |
| 917 | (b)32 A |
| 918 | Cat.I |
| 919 | Cat.II |
| 920 | Cat.III |
| 921 | Erection & connection charges for 16A / 32 A DP as following |
| 922 | (a) on existing wooden block / A.I. frame |
| 923 | (b) on polished wooden block. |
| 924 | (c) on angle iron frame duly painted with Red Oxide |
| 925 | Providing Approved makeTriple Pole Cast Iron Clad Switch & rewirable Fuse with neutral link 415/500 V confirming to IS |
| 926 | (a)16 A. |
| 927 | Cat.I |
| 928 | Cat.II |
| 929 | Cat.III |
| 930 | (b) 32 A |
| 931 | Cat.I |
| 932 | Cat.II |
| 933 | Cat.III |
| 934 | Erection & connection Charges For 16A/32A TP as following |
| 935 | (a) on existing wooden block / A.I.frame |
| 936 | (b) on polished wooden block. |
| 937 | (c) on angle iron frame duly painted with Red Oxide |
| 938 | Providing Approved makeTriple Pole Metal / Iron Clad Switch & Fuse with neutral link 415/500 V confirming to IS |
| 939 | (a)63A |
| 940 | Cat.I |
| 941 | Cat.II |
| 942 | Cat.III |
| 943 | (b) 100 A |
| 944 | Cat.I |
| 945 | Cat.II |
| 946 | Cat.III |
| 947 | Erection & connection Charges for 63A/100A TP as following |
| 948 | (a) on existing wooden block / A.I.frame |
| 949 | (b) Erection on angle iron frame duly painted with Red Oxide |
| 950 | Providing Approved make Triple Pole Metal Clad SwitchFuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS. |
| 951 | (a) 32 A |
| 952 | Cat.II |
| 953 | Cat.III |
| 954 | (b) 63 A. |
| 955 | Cat.II |
| 956 | Cat.III |
| 957 | (c) 100 A/125 A |
| 958 | Cat.II |
| 959 | Cat.III |
| 960 | Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with HRC fuse of suitable load and neutral link confirming to IS |
| 961 | (a)200 A |
| 962 | Cat.II |
| 963 | Cat.III |
| 964 | (b) 250A |
| 965 | Cat.II |
| 966 | Cat.III |
| 967 | (c) 300 A/315 A/325 A |
| 968 | Cat.II |
| 969 | Cat.III |
| 970 | Providing Approved make Triple Pole metal clad switch fuse unit 415 / 500V. 400 A with HRC fuse of suitable load and neutral link confirming to IS |
| 971 | Cat.II |
| 972 | Cat.III |
| 973 | Erection & connection charges for 32A/ 63 A / 100 AHRC TPN as following |
| 974 | (a)on existing wooden block /A.I.frame |
| 975 | (b)Erection on New angle iron frame dulypainted with red oxide |
| 976 | Erection & connection Charges for 200A/ 250A/ 300 A /325 A/400 A HRCTPN as following |
| 977 | (a)on existing wooden block / A.I. frame |
| 978 | (b)Erection on New angle iron frame dulypainted with red oxide . |
| 979 | Providing and erecting Approved make panel mounting front fixing rotary switch (CAM Switch) with face plate with double pair of contacts with two fix and a moving contacts, operated by means of slide, rest on disk with grooves for sequential operation rotated by switch handle, square shaft and knob for Two way with off |
| 980 | (i)Two pole |
| 981 | (a) 16/25A - 240 V |
| 982 | (b) 32A - 240V |
| 983 | (ii) Four pole |
| 984 | (a) 16/25A - 440V |
| 985 | (b) 32A- 440V |
| 986 | (c) 40A - 440V |
| 987 | (d) 63A- 440V |
| 988 | providing and erecting Approved make Three Phase & Neutral LT Heavy Duty Switch Disconnector Fuse Unit Cubical type for panel mounting complete with operating mechanism suitable to operate on 415V A.C. , 23A duty With HRC fuses of suitable loadconfirming to IS. 13947 (Part I & III). of following capacities. |
| 989 | (a) 32 Amp |
| 990 | Cat.II |
| 991 | Cat.III |
| 992 | (b) 63 Amp |
| 993 | Cat.II |
| 994 | Cat.III |
| 995 | (c) 100Amp/125 Amp |
| 996 | Cat.II |
| 997 | Cat.III |
| 998 | (d) 200 Amp |
| 999 | Cat.II |
| 1000 | Cat.III |
| 1001 | (e) 250 Amp |
| 1002 | Cat.II |
| 1003 | Cat.III |
| 1004 | (f) 300/320 Amp |
| 1005 | Cat.II |
| 1006 | Cat.III |
| 1007 | (g) 400 Amp |
| 1008 | Cat.II |
| 1009 | Cat.III |
| 1010 | (h) 630 Amp |
| 1011 | Cat.II |
| 1012 | Cat.III |
| 1013 | (i) 800 Amp |
| 1014 | Cat.II |
| 1015 | Cat.III |
| 1016 | Approved make Four Pole LT Heavy Duty Switch Disconnector Fuse Unit Cubical type for panel mounting complete with operating mechanism suitable to operate on 415V A.C. With HRC fuses of suitable load confirming to IS. 13947 (Part I & III). of following capacities |
| 1017 | (a) 32 Amp |
| 1018 | Cat.II |
| 1019 | Cat.III |
| 1020 | (b) 63 Amp |
| 1021 | Cat.II |
| 1022 | Cat.III |
| 1023 | (c) 125 Amp |
| 1024 | Cat.II |
| 1025 | Cat.III |
| 1026 | (d) 200 Amp |
| 1027 | Cat.II |
| 1028 | Cat.III |
| 1029 | (e) 250 Amp |
| 1030 | Cat.II |
| 1031 | Cat.III |
| 1032 | (f) 315/320 Amp |
| 1033 | Cat.II |
| 1034 | Cat.III |
| 1035 | (g) 400 Amp |
| 1036 | Cat.II |
| 1037 | Cat.III |
| 1038 | (h) 630 Amp |
| 1039 | Cat.II |
| 1040 | Cat.III |
| 1041 | (i) 800 Amp |
| 1042 | Cat.II |
| 1043 | Cat.III |
| 1044 | Supplying & erecting following spare parts for panel mounting Switch Disconnector Fuse Units |
| 1045 | Operational Handle Assembly Complete for |
| 1046 | (i) 32 / 63 / 125 Amps |
| 1047 | (ii) 200 / 250 / 320 / 400 / 630 / 800 Amps |
| 1048 | Operating Shaft (Extensible) for |
| 1049 | (i) 32 / 63 / 125 Amps |
| 1050 | (ii) 200 / 250 / 320 / 400 / 630 / 800 Amps |
| 1051 | Cable Terminal ( ‘Z\" Type) Set of Two for |
| 1052 | (i)200 / 250 Amps |
| 1053 | (ii) 320 / 400 Amps |
| 1054 | (iii) 630 / 800 Amps |
| 1055 | Cable Terminal ( ‘Plain\" Type)Set of Four for |
| 1056 | (i)32 / 63 Amps |
| 1057 | (ii)125 / 200 Amps |
| 1058 | (iii) 250 / 320Amps |
| 1059 | (iv)400 / 630/ 800 Amps |
| 1060 | HRC Fuse ContactsSetof six for |
| 1061 | (i) 32 / 63 Amps |
| 1062 | (ii) 125Amps |
| 1063 | (iii)200 / 250 / 320 / 400 Amps |
| 1064 | (iv) 630 / 800 Amps |
| 1065 | Moving Contact finger of Set of Six for 32 / 63 / 125 Amps |
| 1066 | Moving Contact finger of Set of Eight for 200 / 250 / 320 / 400 / 630 / 800 Amps |
| 1067 | Neutral Link for |
| 1068 | (i) 32 / 63 / 125Amps |
| 1069 | (ii) 200 / 250 / 320 / 400 / 630 / 800 Amps |
| 1070 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1071 | Cat-ll |
| 1072 | ICS=100% of ICU only Cat III |
| 1073 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1074 | Cat-ll |
| 1075 | ICS=100% of ICU onlyCat III |
| 1076 | providing and erecting Approved make Four polemoulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S.housing |
| 1077 | Cat-ll |
| 1078 | ICS=100% of ICU only Cat III |
| 1079 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. and above at 415 V. having normal current rating250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1080 | Cat-ll |
| 1081 | ICS=100% of ICU onlyCat III |
| 1082 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KAand above at 415 Vhaving Normal current rating400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1083 | Cat-ll |
| 1084 | ICS=100% of ICU only Cat III |
| 1085 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A.and above at 415 Vhaving normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing |
| 1086 | Cat-ll |
| 1087 | ICS=100% of ICU only Cat III |
| 1088 | providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A.and above at 415 Vhaving normal current rating 800A.with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S.housing. |
| 1089 | Cat-ll |
| 1090 | ICS=100% of ICU onlyCat III |
| 1091 | providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity ICU of 25 K.A. at 415 V having normal current rating up to25A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1092 | Cat-ll |
| 1093 | ICS=100% of ICU onlyCat III |
| 1094 | providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 35 K.A. at 415 V. having normal current rating 125A.with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1095 | Cat-ll |
| 1096 | ICS=100% of ICU only Cat III |
| 1097 | providing and erecting Approved make Three polemoulded case circuit breaker having breaking capacity/strength ICU of 35 K.A. and above at 415 V. having Normal current rating200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1098 | Cat-ll |
| 1099 | ICS=100% of ICU only Cat III |
| 1100 | providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A.and above at 415V. having normal current rating250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1101 | Cat-ll |
| 1102 | ICS=100% of ICU only Cat III |
| 1103 | providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A.and aboveat 415 Vhaving Normal current rating400A with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections & complete erected in existing 16 G.M.S. housing. |
| 1104 | Cat-ll |
| 1105 | ICS=100% of ICU onlyCat III |
| 1106 | providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable tofollowing size of moulded case circuit breaker having CT ratio& MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existingM.S.housing.. |
| 1107 | (1) 15 A -100 A , CT Ratio 1/100 |
| 1108 | (2) 125 A -200 A , CT Ratio 1/200 |
| 1109 | (3) 250 A -400 A , CT Ratio 1/400 |
| 1110 | (4) 600 A -800 A , CT Ratio 1/800 |
| 1111 | providing and erecting following additional parts for panel mounting MCCBs |
| 1112 | (A)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 25A to 250 A panel mounting cat-III |
| 1113 | (B)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 400A to 630 A panel mounting cat-III |
| 1114 | supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to ISof following capacity |
| 1115 | (A) 16A |
| 1116 | Cat I |
| 1117 | Cat. II |
| 1118 | (B) 32A |
| 1119 | Cat I |
| 1120 | Cat. II |
| 1121 | Erection & connection charges for16 A / 32A Change Over Switch as following |
| 1122 | (a) on existing wooden block / A.I.frame |
| 1123 | (b) on polished wooden block. |
| 1124 | (c) on angle iron frame |
| 1125 | supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to ISof following capacity |
| 1126 | (A) 63 A |
| 1127 | Cat I |
| 1128 | Cat II |
| 1129 | Cat III |
| 1130 | (B)100 A / 125 A |
| 1131 | Cat I |
| 1132 | Cat II |
| 1133 | Cat III |
| 1134 | Erection & connection charges for 63 A / 100A / 125 Achange over switch as following |
| 1135 | (a)on existing wooden block / A.I.frame |
| 1136 | (b)Erection on New angle iron frame dulypainted with red oxide |
| 1137 | supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to ISof following capacity |
| 1138 | (A)200 A / 250 A |
| 1139 | Cat-ll |
| 1140 | Cat-lll |
| 1141 | Erection & connection charges for200A/ 250A / 300 A /325 A HRCTPN as following |
| 1142 | (a)on existing wooden block / Angle Iron frame |
| 1143 | (b)Erection on New angle iron frame dulypainted with red oxide . |
| 1144 | Supplying & erecting approved make Four Pole 415V change over switch interior for panel mounting with operating mechanism A.C.23 duty confirming to IS for |
| 1145 | (A)32-40A |
| 1146 | Cat-ll |
| 1147 | Cat-lll |
| 1148 | (B)63 A |
| 1149 | Cat-ll |
| 1150 | Cat-lll |
| 1151 | (C)100-125A |
| 1152 | Cat-ll |
| 1153 | Cat-lll |
| 1154 | Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with Aluminium busbar having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each Suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessary connections. |
| 1155 | (A) Suitable for 63/ 100 Amp. Capacity |
| 1156 | Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with COPPER busbar having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessaryconnections. |
| 1157 | (A) Suitable for 63/100 Amp. capacity |
| 1158 | Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections. |
| 1159 | (A) Suitable for 100 Amp. Capacity |
| 1160 | (B) Suitable for 200 Amp. Capacity |
| 1161 | Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each bar, erected in existing cubical panel with necessaryconnections. |
| 1162 | (A) Suitable for 100 Amp. Capacity |
| 1163 | (B) Suitable for 200 Amp. capacity |
| 1164 | Supplying KITKAT pattern porcelain cut-out fuse with base of following current capacity erected on existing block board. |
| 1165 | (i) 16 A. 250 V . |
| 1166 | (ii) 16 A. 500 V. |
| 1167 | (iii) 32 A. 250/500 V. |
| 1168 | (iv) 63 A 500 V |
| 1169 | (v)100 A. 500 V. |
| 1170 | (vi) 200 A. 500 V. |
| 1171 | Supplying and erecting approved make 415V bakelite fuse fittings for front connection / busbar type, to accommodate HRC fuse link, with spin - riveted brass contact, having thermo plastic inflammable material & single piece extruded brass box contact to lock with adequate cable hole to accommodate aluminium conductors suitable for (without HRC fuse) |
| 1172 | (A) 16 Amp. |
| 1173 | (B) 32 Amp. |
| 1174 | (C) 63 Amp. |
| 1175 | (D) 100 Amp. |
| 1176 | Supplying Knife / Blade / DIN type HRC fuse link capable to withstand 80 K.A. confirms to I.S. 13703 for following current capacity |
| 1177 | (A) 63 Amp. to 100 Amp.(Size 000 ) |
| 1178 | (B) 63 Amp to 100 Amp (Size 00) |
| 1179 | (C) 125 Amp to 160 Amp (Size 00) |
| 1180 | (D) 100 Amp to 200 Amp (Size 0) |
| 1181 | (E) 125 Amp to 200 Amp (Size I ) |
| 1182 | (F) 250 Amp (Size I ) |
| 1183 | (G)200 Amp to 400 Amp (Size II ) |
| 1184 | (H)400 Amp to 630 Amp (Size III ) |
| 1185 | (I) 800 Amp (Size III ) |
| 1186 | Supplying Bolted Connections (BS type) HRC fuse link capable to withstand 80KA confirms to I.S. 13703 for following current capacity |
| 1187 | (A) up to 32 Amp. |
| 1188 | (B) 36 Amp. to 63 Amp. |
| 1189 | (C) 80 Amp. to 125 Amp. |
| 1190 | (D) 126 Amp. to 200 Amp. |
| 1191 | (E) 250 Amp. to 315 Amp. |
| 1192 | (F) 400 Amp. to 450 Amp. |
| 1193 | (G) 500 Amp. to 630 Amp. |
| 1194 | Insulated Fuse Pulling Handle for Knife / Blade / DIN / Bolted Type HRC Fuse Link from 63 A to 800 A |
| 1195 | providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark |
| 1196 | Cat.III |
| 1197 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark |
| 1198 | Cat.I |
| 1199 | Cat.II |
| 1200 | Cat.III |
| 1201 | Providing & erecting 240 V MCB double pole switch for motor & inductive load(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity |
| 1202 | (A) 6 to 32 Amp. |
| 1203 | Cat.I |
| 1204 | Cat.II |
| 1205 | Cat.III |
| 1206 | (B) 40 Amp. |
| 1207 | Cat.I |
| 1208 | Cat.II |
| 1209 | Cat.III |
| 1210 | Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity |
| 1211 | (A) 6 to 32 Amp. |
| 1212 | Cat.I |
| 1213 | Cat.II |
| 1214 | Cat.III |
| 1215 | (B) 40 Amp. |
| 1216 | Cat.I |
| 1217 | Cat.II |
| 1218 | Cat.III |
| 1219 | Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity |
| 1220 | (a) 6 to 32 Amp. |
| 1221 | Cat.I |
| 1222 | Cat.II |
| 1223 | Cat.III |
| 1224 | (b)40 Amp. |
| 1225 | Cat.I |
| 1226 | Cat.II |
| 1227 | Cat.III |
| 1228 | Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity |
| 1229 | (a) 6 to 32 Amp. |
| 1230 | Cat.I |
| 1231 | Cat.II |
| 1232 | Cat.III |
| 1233 | (b)40 Amp. |
| 1234 | Cat.I |
| 1235 | Cat.II |
| 1236 | Cat.III |
| 1237 | (c)63 Amp. |
| 1238 | Cat.I |
| 1239 | Cat.II |
| 1240 | Cat.III |
| 1241 | Providing & erecting 415 V MCB three Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity |
| 1242 | (a) 6 to 32 Amp. |
| 1243 | Cat.I |
| 1244 | Cat.II |
| 1245 | Cat.III |
| 1246 | (b)40 Amp. |
| 1247 | Cat.I |
| 1248 | Cat.II |
| 1249 | Cat.III |
| 1250 | (c)63 Amp. |
| 1251 | Cat.I |
| 1252 | Cat.II |
| 1253 | Cat.III |
| 1254 | Supplying & erecting 20 Amp 10 KA‘C Curve’ single pole MCB with 20 Amp. Plug socket, company fabricated powder coated sheet steel enclosure erected as directed with connection. |
| 1255 | [A] Metal Clad Socket with metal clad top |
| 1256 | Cat.I |
| 1257 | Cat.II |
| 1258 | Cat.III |
| 1259 | [B] 15 Amp. / 5 Amp. Five pin Universal Socket |
| 1260 | Cat.I |
| 1261 | Cat.II |
| 1262 | Cat.III |
| 1263 | Supplying & erecting approved make Electronics Starter and relay for air conditioners in ABS plastic moulded housing. Company fabricated with bakelite terminal for connection with silver coating bimetallic contact in switching device for o/p with following features.(1) Low Voltage Protection below 130 V(2) High Voltage protection above 270 V(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-22 Amp. (inverse time chara-)(4) Indicating LEDs for AC on LV, HV, O/L, T/D(5) With unique feature of 3 minute of time delay |
| 1264 | Providing and erecting double pole Miniature isolator A.C. 22 duty confirms to IS 13947-3 240V 40A in existing box. |
| 1265 | Cat.I |
| 1266 | Cat.II |
| 1267 | Cat.III |
| 1268 | Providing and erecting Threepole Miniatureisolator A.C. 22 duty confirms to IS 13947-3 in existing box. |
| 1269 | (a) for 40 Amp. |
| 1270 | Cat.I |
| 1271 | Cat.II |
| 1272 | Cat.III |
| 1273 | (b) for 63 Amp. |
| 1274 | Cat.I |
| 1275 | Cat.II |
| 1276 | Cat.III |
| 1277 | (c) for 100 Amp. |
| 1278 | Cat.I |
| 1279 | Cat.II |
| 1280 | Cat.III |
| 1281 | Providing and erecting fourpole Miniature isolator A.C. 22 duty confirms to IS 13947-3 in existing box. |
| 1282 | (a) for 40 Amp. |
| 1283 | Cat.I |
| 1284 | Cat.II |
| 1285 | Cat.III |
| 1286 | (b) for 63 Amp. |
| 1287 | Cat.I |
| 1288 | Cat.II |
| 1289 | Cat.III |
| 1290 | (c) for 100 Amp. |
| 1291 | Cat.I |
| 1292 | Cat.II |
| 1293 | Cat.III |
| 1294 | Providing and erecting Two way Centre off Doublepole MCB Change Over Switch (IS 13947-3 / IEC 60947-3) in existing box. |
| 1295 | (a) for 25 Amp |
| 1296 | Cat.I |
| 1297 | Cat.II |
| 1298 | Cat.III |
| 1299 | (b) for 40 Amp. |
| 1300 | Cat.I |
| 1301 | Cat.II |
| 1302 | Cat.III |
| 1303 | Providing and erecting Two way Centre off Fourpole MCB Change Over Switch (IS 13947-3 / IEC 60947-3) in existing box. |
| 1304 | (a) for 25 Amp |
| 1305 | Cat.I |
| 1306 | Cat.II |
| 1307 | Cat.III |
| 1308 | (b) for 40 Amp |
| 1309 | Cat.I |
| 1310 | Cat.II |
| 1311 | Cat.III |
| 1312 | Half / One Module Blanking Plate of Standard Size. |
| 1313 | Plastic enclosure fitted with DIN rail suitable for incorporatingOne / Two nos. MCB |
| 1314 | Plastic enclosure fitted with DIN rail suitable for incorporatingThree /Four nos. MCB |
| 1315 | Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. |
| 1316 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for |
| 1317 | (A) single phase incoming and horizontal single phase outgoing |
| 1318 | (a) single door (IP-30) |
| 1319 | (i)4 way |
| 1320 | (ii)6 way |
| 1321 | (iii)8 way |
| 1322 | (iv)12 way |
| 1323 | (v) 16 way |
| 1324 | (b) sheet steel double door (IP-43) |
| 1325 | (i)4 way |
| 1326 | (ii)6 way |
| 1327 | (iii)8 way |
| 1328 | (iv)12 way |
| 1329 | (v) 16 way |
| 1330 | (B) three phase incoming and single phase horizontal type outgoingPer phase isolation type (PPI) |
| 1331 | (a) single door |
| 1332 | (i)4 way |
| 1333 | (ii)6 way |
| 1334 | (iii)8 way |
| 1335 | (iv)12 way |
| 1336 | (b) sheet steel double door |
| 1337 | (i)4 way |
| 1338 | (ii)6 way |
| 1339 | (iii)8 way |
| 1340 | (iv)12 way |
| 1341 | (v) 16 way |
| 1342 | Supplying & erecting Sheet Steel powder coated Cable end termination Box to bemounted on Top or Bottom of the MCB Distribution Box for housing/covering Extra wires & Cables, suitable for following size of MCB DB Box. |
| 1343 | (A) Single Phase 4 Way |
| 1344 | (B) Single Phase 6 Way |
| 1345 | (C) Single Phase 8 Way |
| 1346 | (D) Single Phase 12 Way |
| 1347 | (E) Three Phase 4 Way |
| 1348 | (F)Three Phase 6 Way |
| 1349 | (G) Three Phase 8 Way |
| 1350 | (H) Three Phase 12 Way |
| 1351 | (I) Three Phase 16 Way |
| 1352 | Providing and erecting approved make thermo-plastic moulded distribution box for mounting MCB /ELCB having DIN rail transparent moulded flap 100Amp. copper bus strip for (Without MCB/ELCB) |
| 1353 | a) For 7 way |
| 1354 | b) For 18 way |
| 1355 | Providing & erecting approved make thermo plastic MCB/ELCB distribution board having modular Double door with DIN rails, epoxy powder coated finish metal frame & door assembly with Acrylic/ Plastic door, spring & hinged pins complete with required PVC sleeved 32 / 63A copper Bus strips without MCB / ELCBs |
| 1356 | (a) OneRow8 Module |
| 1357 | (b) OneRow 10 Module |
| 1358 | (c) OneRow 14 Module |
| 1359 | (d) TwoRow 20 Module |
| 1360 | (e) TwoRow 28 Module |
| 1361 | (f) TwoRow 36 Module |
| 1362 | The Above all items of MCB, DBthe cost of erection on New angle iron frame add following. |
| 1363 | [A] up to 8 way single phase |
| 1364 | [B] above single phase 8 way and all three phase DBs. |
| 1365 | Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for250 AMP TPN MCCB+ RCCB as incomer and three phaseoutgoing as per following .(The DBs should be used of same company of MCB to be used) |
| 1366 | (A)4 wayoutgoing |
| 1367 | (B)6 way outgoing |
| 1368 | (C)8 wayoutgoing |
| 1369 | (D)12 way outgoing |
| 1370 | Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for250 AMP TPN MCCB+ RCCB as incomer and three phaseoutgoing as per following .(The DBs should be used of same company of MCB to be used) |
| 1371 | (A)4 way outgoing |
| 1372 | (B)6 way outgoing |
| 1373 | (C)8 way outgoing |
| 1374 | (D)12 way outgoing |
| 1375 | Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed |
| 1376 | (i) 25 Amps.DP |
| 1377 | Cat. I |
| 1378 | Cat. II |
| 1379 | Cat. III |
| 1380 | (ii) 40Amps. DP |
| 1381 | Cat. I |
| 1382 | Cat. II |
| 1383 | Cat. III |
| 1384 | (iii) 63 Amps. DP |
| 1385 | Cat. I |
| 1386 | Cat. II |
| 1387 | Cat. III |
| 1388 | Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component for following Max. ratingerected as directed. |
| 1389 | (i) 25 Amps.FP |
| 1390 | Cat. I |
| 1391 | Cat. II |
| 1392 | Cat. III |
| 1393 | (ii) 40Amps. FP |
| 1394 | Cat. I |
| 1395 | Cat. II |
| 1396 | Cat. III |
| 1397 | (iii) 63 Amps. FP |
| 1398 | Cat. I |
| 1399 | Cat. II |
| 1400 | Cat. III |
| 1401 | (iv) 100 Amps. FP (100 mA Sensitivity) |
| 1402 | Cat. II |
| 1403 | Cat. III |
| 1404 | Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 10 KA short circuit breaking capacity and 30 mAmp.Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed. |
| 1405 | [a] 6A / 10A / 16A / 20A / 25A 2 pole single phaseCat. II |
| 1406 | [b] 32A / 40A, 2 pole Single PhaseCat. II |
| 1407 | [c] 63 A, 2 pole Single PhaseCat. II |
| 1408 | [d] 6A to 25 A, 4 Pole Three PhaseCat. II |
| 1409 | [e] 32A to 40 A, 4 Pole Three PhaseCat. II |
| 1410 | [f] 63A, 4 pole Three PhaseCat. II |
| 1411 | Supplying & fixing box for housing RCCB+ MCB combination made of 18 SWG sheet steel duly powder coated with gasket, dust & vermin proof bakelite shield two earthing terminals for following type of RCCB,RCCB + MCB |
| 1412 | [a] For 2 pole |
| 1413 | [b] For 4 Pole |
| 1414 | Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. |
| 1415 | Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for HIGH VOLTAGE installation to be erected as per IS.-2551. |
| 1416 | Providing & erecting Medium Voltage Danger Notice Board sticker as per language suggested by engineer incharge of standard size as per IS-2551 |
| 1417 | Providing & erecting High Voltage Danger Notice Board sticker as per language suggested by engineer incharge of standard size-as per IS 2551 |
| 1418 | Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. |
| 1419 | Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. |
| 1420 | Providing and erecting Annealed bare Copper wire 8 to 16 SWG. |
| 1421 | Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. |
| 1422 | Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. galvanised iron pipe with coupling and buch buried in specially prepared earth pit complete with necessary 8 SWG earth wire. |
| 1423 | Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long \"B\" grade G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For panel) |
| 1424 | For using salt and charcoal / coke as required for pipe type earthing. |
| 1425 | Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipeshaving Outer pipedia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approvedmake OEM has to submit test certificate) & having back filling compound of (B)Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm/ meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long timeNecessary test report must be submitted. |
| 1426 | (a) For Electrical Installation up to 440V in normal soilLength of pipe - 1 MtrBack filling compound - 1 Nos Bag of 15 Kg. |
| 1427 | (b)For Electrical installation up to 11 KV in normal soil.Length of Pipe : 2.00 mtrsBack filling Compound :1 no. Bag of 25 Kg. |
| 1428 | (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil.Length of Pipe : 3.00 mtrs Back filling Compound :2 nosBags of 25 Kg. |
| 1429 | Supplying & erecting in earthpit of minimum bore dia. 225mm sizeapproved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipeshaving Outer pipedia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applicationswith chamber and heavy duty cover.(approvedmake OEM has to submit test certificate including value of earth resistane of installation. |
| 1430 | [A] For electrical installation up to 440 VLength of Pipe - 1 MtrBack filling compound - 1 Nos. of Bag of 15 Kgs. |
| 1431 | [B] For Electrical installation up to 11 KVlocated in other than normal soil i.e.Soft Rock, Marshy Soil etc. -Length of Pipe : 2 mtr-Back filling Compound :1 no. Bag of 25Kg. |
| 1432 | [C] For Electrical Installation covering Transformer Neutrals, Lightningarrester Earthing, A.C.Plant & SensitiveComputer System(likeAutomation,SCADA)i.e. independent Earthinglocated in other than normal soil i.e.Soft Rock,Marshy Soil etc..-Length of Pipe : 3 Mtrs.-Back filling Compound :2 nosBags of 25 Kg. |
| 1433 | Providing one bag of 25 Kg. Additional Back Filling Compound (BFC) suitable for safe earthingdevice. |
| 1434 | Supplying & erecting funnel type earthing having earth plate of following size burredinspecificallyprepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia.G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia.G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification |
| 1435 | (A) With 30 x 30 x 0.35 cms: C.I. earth plate |
| 1436 | (B) With 45 x 45 x 0.35 cms.C.I. earth plate |
| 1437 | (C) with 60 x 60x 0.315 cms.Copper earth Plate |
| 1438 | ADD Extra for excavation in Semi hard rock (Murrum) by dry and wet blasting and chiselling for funnel type earthing of above |
| 1439 | providing and erecting Cast iron earth plate size 30 X 30 X 0.35 cms. buried in specially prepared 2.5 Mtr. deep earth pit complete with necessary G.I. strip in G.I. pipe 2 Mtr. long with coupling and G.I. plug for earthing of switch gear, conduit run or power plug etc. |
| 1440 | providing and erecting Castironearthplatesize45 X45X0.35 cms. buried in specially prepared 2.5 Mtr. Deep earth Pit complete with necessary G.I. strip in G.I. pipe 2 Mtr. long with coupling and G.I. plug for earthing of switch gear, conduit run or power plug etc. |
| 1441 | Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxidewith erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. |
| 1442 | Painting the number and words for inventory Identification on erected fittings / equipment’s or Such accessories as may required with good quality of enamelled paint as directed by engineer in charge. |
| 1443 | (i) up to 20 characters, up to 50 mm height. |
| 1444 | (ii)Add. for additional character. |
| 1445 | (iii) Add for additional each 25mm. height |
| 1446 | Supplying and erecting nuwood 12mm thick on existing angle iron frame or wooden patti |
| 1447 | Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. |
| 1448 | (A) 2 core 2.5 Sq. mm |
| 1449 | (B) 2 core 4 Sq. mm |
| 1450 | (C) 2 core 6 Sq. mm |
| 1451 | (D) 2 core 10 Sq. mm |
| 1452 | Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. |
| 1453 | (A)3 core 2.5 Sq. mm |
| 1454 | (B)3 core 4 Sq. mm |
| 1455 | (C)3 core 6 Sq. mm |
| 1456 | (D)3 core 10 Sq. mm |
| 1457 | Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 1.1 KV.grade to be erected as directed of following size. |
| 1458 | (A)4 core 2.5 Sq. mm |
| 1459 | (B)4 core 4 Sq. mm |
| 1460 | (C)4 core 6 Sq. mm |
| 1461 | (D)4 core 10 Sq. mm |
| 1462 | Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. |
| 1463 | (A) 2 core 2.5 Sq. mm |
| 1464 | (B) 2 core 4 sq.mm |
| 1465 | (C) 2 core 6 Sq. mm |
| 1466 | (D) 2 core 10 Sq. mm |
| 1467 | (E)3 core 2.5 Sq. mm |
| 1468 | (F) 3 core 4 Sq. mm |
| 1469 | (G) 3 core 6 Sq. mm |
| 1470 | (H) 3 core 10Sq. mm |
| 1471 | (I) 3 core 16 Sq. mm |
| 1472 | (J) 4 core 2.5 Sq. mm |
| 1473 | (K) 4 core 4 Sq. mm |
| 1474 | (L) 4 core 6 Sq. mm |
| 1475 | (M) 4 core 10 Sq. mm |
| 1476 | (N) 4 core 16 Sq. mm |
| 1477 | Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. |
| 1478 | (A)7 core 1.5Sq. mm |
| 1479 | (B)7 core 2.5 Sq. mm |
| 1480 | (C) 7 core 4 sq.mm |
| 1481 | (D) 8 core 2.5 sq.mm |
| 1482 | (E) 12 core 2.5 sq.mm |
| 1483 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. |
| 1484 | (A) 2 core 4 Sq. mm |
| 1485 | (B) 2 core 6 Sq. mm |
| 1486 | (C) 2 core 10 Sq. mm |
| 1487 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. |
| 1488 | (A) 3 core 2.5 Sq. mm |
| 1489 | (B) 3 core 4 Sq. mm |
| 1490 | (C) 3 core 6 Sq. mm |
| 1491 | (D) 3 core 10 Sq. mm |
| 1492 | (E) 3 core 16 Sq. mm |
| 1493 | (F) 3 core 25 Sq. mm |
| 1494 | (G) 3 core 35 Sq. mm |
| 1495 | (H) 3 core 50 Sq. mm |
| 1496 | (I) 3 core 70 Sq. mm |
| 1497 | (J) 3 core 95 Sq. mm |
| 1498 | (K) 3 core 120 Sq. mm |
| 1499 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables |
| 1500 | (A) 3 1/2core 25 Sq. mm ( 16 Sq. mm 1/2 core) |
| 1501 | (B) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core) |
| 1502 | (C) 3 1/2core 50 Sq. mm ( 25 Sq.1/2 mmcore) |
| 1503 | (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) |
| 1504 | (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) |
| 1505 | (F) 3 1/2core 120 Sq. mm ( 70 Sq. mm 1/2 core) |
| 1506 | (G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) |
| 1507 | (H) 3 1/2core 185 Sq. mm ( 95 Sq. mm1/2 core) |
| 1508 | (I) 3 1/2 core 240 Sq. mm( 120 Sq. mm1/2core) |
| 1509 | (J) 3 1/2core 300 Sq.mm ( 150 Sq. mm1/2core) |
| 1510 | (K) 3 1/2core 400 Sq.mm ( 185 Sq. mm1/2core) |
| 1511 | (L) 3 1/2 core 500 Sq.mm ( 240 Sq. mm 1/2 core) |
| 1512 | (M) 3 1/2 core 630 sq. mm (300 sq.mm 1/2 core) |
| 1513 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables |
| 1514 | (A) 4 core 4 Sq. mm |
| 1515 | (B) 4 core 6 Sq. mm |
| 1516 | (C) 4 core 10 Sq. mm |
| 1517 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables |
| 1518 | (A) 4 core 16 Sq. mm |
| 1519 | (B) 4 core 25 Sq. mm |
| 1520 | (C) 4 core 35 Sq. mm |
| 1521 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe of following size of cables |
| 1522 | (A) 2 core 2.5 Sq. mm |
| 1523 | (B) 2 core 4 Sq. mm |
| 1524 | (C) 2 core 6 Sq. mm |
| 1525 | (D) 2 core 10 Sq. mm |
| 1526 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof following size of cable. |
| 1527 | (A) 3 core 2.5Sq. mm |
| 1528 | (B) 3 core 4 Sq. mm |
| 1529 | (C) 3 core 6 Sq. mm |
| 1530 | (D) 3 core 10 Sq. mm |
| 1531 | (E) 3 core 16 Sq. mm |
| 1532 | (F) 3 core 25 Sq. mm |
| 1533 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof following size of cables. |
| 1534 | (A) 3 1/2core 25 Sq. mm ( 10 Sq. mm 1/2 core) |
| 1535 | (B) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core) |
| 1536 | (C) 3 1/2core 50 Sq. mm ( 25 Sq. mm1/2 core) |
| 1537 | (D) 3 1/2core 70 Sq. mm ( 35 Sq. mm1/2 core) |
| 1538 | (E) 3 1/2core 95 Sq. mm ( 50 Sq. mm 1/2 core) |
| 1539 | (F) 3 1/2core 120 Sq. mm ( 70 Sq. mm 1/2 core) |
| 1540 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / SolidCopperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables. |
| 1541 | (A) 4 core 2.5 Sq. mm |
| 1542 | (B) 4 core 4 Sq. mm |
| 1543 | (C) 4 core 6 Sq. mm |
| 1544 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables. |
| 1545 | (A) 4 core 10 Sq. mm |
| 1546 | (B)4 core 16 Sq. mm |
| 1547 | (C) 4 core 25 Sq. mm |
| 1548 | (D) 8 core 2.5 sq.mm |
| 1549 | (E) 12 core 2.5 sq.mm |
| 1550 | Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the faultall over the run and back filling the same and making the surface as normal ground. |
| 1551 | Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or requireddepth for laying any size of cable or locating the faultall over the run and back filling the same and making the surface as normal ground. |
| 1552 | (B) If additional machinery like hammer driller or JCB use [Add] |
| 1553 | Covering of cable with second class bricks or cement tileslaid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter) |
| 1554 | Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding power supply by making up to following size of holes at both ends complete. |
| 1555 | (A) Up to 100 mm bore dia |
| 1556 | (B) Up to 150 mm bore dia |
| 1557 | Providing and erecting iron clad cable route marker duly marked with ELE.CABLE of size 23 cm.X 12 cm. Flushed with ground in cement foundation as directed by Engineer in charge. |
| 1558 | Supplyingfollowing size of Lightduty “A” Class G.I . Pipe & erecting as directedby Engineer-in-charge. |
| 1559 | (A) 25 mm dia |
| 1560 | (B) 50 mm dia |
| 1561 | (C) 80 mm dia. |
| 1562 | (D) 100 mm dia. |
| 1563 | Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. |
| 1564 | (A) 450 mm dia |
| 1565 | (B) 400 mm dia |
| 1566 | (C) 300 mm dia |
| 1567 | (D) 250 mm dia |
| 1568 | (E)150 mm dia |
| 1569 | (F) 100 mm dia. |
| 1570 | (i) Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connectingaccessories of same material at required depth in existing trenchfor laying ofcable. below ground/ road surface for enclosing cable |
| 1571 | (A)50 mm outer dia |
| 1572 | (B)63mm outer dia |
| 1573 | (C))90 mmouter dia |
| 1574 | (D)120 mmouter dia. |
| 1575 | (ii) Providing & layingapproved make ISI marked HDPE 6Kg / cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. |
| 1576 | (A) 40 mm inner Dia. |
| 1577 | (B) 50 mm inner Dia. |
| 1578 | (C) 63 mm inner Dia. |
| 1579 | (D) 75 mm inner Dia. |
| 1580 | (E) 90 mm inner Dia |
| 1581 | (F) 110 mm inner Dia. |
| 1582 | Providing & layingapproved make ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. |
| 1583 | (A) 40 mm inner Dia. (1.68 Kg / 6 RMT) |
| 1584 | (B) 50 mm inner Dia. (2.5Kg/6RMT) |
| 1585 | (C) 63 mm inner Dia. (4 Kg / 6RMT) |
| 1586 | (D) 75 mm inner Dia. (5.5 Kg/6RMT) |
| 1587 | (E) 90 mm inner Dia (8.0 Kg / 6RMT) |
| 1588 | (F) 110 mm inner Dia. (11.63 Kg/6 RMT) |
| 1589 | Locating Underground Cable Fault of UndergroundCable including digging,pin pointing with cable route tracker bu usingcable fault location equipment like cable fault Van/Vehicle with supportive meters and accessories & doing high pressure testing of cable for checking healthiness of cable with suitable equipment after jointing of the faulty cable (excluding jointing kit) with report ofshowing distance from main source approx. |
| 1590 | (a) LT Cable 35 sq.mm and above |
| 1591 | (b) HT Cable |
| 1592 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. |
| 1593 | (A) 2 to 4 core 2.5 / 4 Sq. mm |
| 1594 | (B) 2 to 4 core 6 Sq. mm |
| 1595 | (C) 2 to 4 core 10 Sq. mm |
| 1596 | (D) 2 to 4 core 16 Sq. mm |
| 1597 | (E) 2 to 4 core 25 Sq. mm |
| 1598 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. |
| 1599 | (A) 3 core 35/50 Sq. mm |
| 1600 | (B) 3 core 70 Sq. mm |
| 1601 | (C) 3 core 95 Sq. mm |
| 1602 | (D) 3 core 120 Sq. mm |
| 1603 | (E) 3 core 150 Sq. mm |
| 1604 | (F) 3 core 185 Sq. mm |
| 1605 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. |
| 1606 | (A) 3 & 1/2 /4 core 25 Sq. mm |
| 1607 | (B) 3 & 1/2core 35/50 Sq. mm |
| 1608 | (C) 3 & 1/2 core 70 Sq. mm |
| 1609 | (D) 3 & 1/2core 95 Sq. mm |
| 1610 | (E) 3& 1/2 core 120 Sq. mm |
| 1611 | (F) 3 & 1/2 core 150 Sq. mm |
| 1612 | (G) 3 & 1/2core 185 Sq. mm |
| 1613 | (H) 3 & 1/2core 240 Sq. mm |
| 1614 | (I) 3 & 1/2 core 300 Sq. mm |
| 1615 | (J) 3 & 1/2core 400 Sq. mm |
| 1616 | (K) 3 & 1/2 core 500 Sq. mm |
| 1617 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. |
| 1618 | (A) 1.5/ 2.5/4/6 Sq.mm |
| 1619 | (B) 10 Sq.mm |
| 1620 | (C) 16/25 Sq.mm. |
| 1621 | (D) 35/50 Sq.mm. |
| 1622 | (E) 70 Sq.mm. |
| 1623 | (F) 95 Sq.mm. |
| 1624 | (G) 120 Sq.mm. |
| 1625 | (H) 150 Sq.mm. |
| 1626 | (I) 185 Sq.mm. |
| 1627 | (J) 225 Sq.mm. |
| 1628 | (K) 300 Sq.mm. |
| 1629 | (L) 400 Sq.mm. |
| 1630 | (M) 500 Sq.mm. |
| 1631 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. |
| 1632 | (A) 1.5/2.5 to 6 Sq.mm |
| 1633 | (B) 10 Sq.mm |
| 1634 | (C) 16 Sq.mm. |
| 1635 | (D) 25 Sq.mm. |
| 1636 | (E) 35/50 Sq.mm. |
| 1637 | (F) 70 Sq.mm. |
| 1638 | (G) 95 Sq.mm. |
| 1639 | (H) 120 Sq.mm. |
| 1640 | (I) 150 Sq.mm. |
| 1641 | (J) 185 Sq.mm. |
| 1642 | (K) 225 Sq.mm. |
| 1643 | Providing and erecting 18 G.M.S. Cable end termination box, indoor type suitable for switch complete erected with clamp, bolt, nut etc.. of following size of TPN. |
| 1644 | (A) Suitable for 63/100 Amp. TPN |
| 1645 | (B) Suitable for 200 Amp. TPN |
| 1646 | (C) Suitable for 250/300 Amp. TPN |
| 1647 | (D) Suitable for 400 Amp. TPN |
| 1648 | (E) Suitable for 600 Amp. TPN |
| 1649 | (F) Suitable for 800 Amp. TPN |
| 1650 | Providing and erecting 18 G. M.S.termination box outdoor type suitable for- 1.1 KV PVC insulated armoured cable complete erected with clamp, bolts, nuts etc. suitable of following size of cables. |
| 1651 | (A) 3 core 70 / 95 Sq. mm |
| 1652 | (B) 3 core 120 / 150 / 185 Sq. mm |
| 1653 | (C) 3 core 240 / 300 Sq. mm |
| 1654 | (D) 3 core 400 / 500 Sq. mm |
| 1655 | Providing and erecting Epoxy Outdoor / Indoor endtermination Kit suitable for LTPVC insulated armoured cable1.1 KV grade complete with ferrule bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cables of following size. |
| 1656 | (A) 2.5 to 16Sq. mm |
| 1657 | (B) 25 to50Sq. mm |
| 1658 | (C) 70 to 120Sq. mm |
| 1659 | (D) 150 / 185 Sq. mm |
| 1660 | (E) 240 / 300 Sq. mm |
| 1661 | (F) 400 / 500 Sq. mm |
| 1662 | Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS. |
| 1663 | (A) up to 25 Sq mm Cable |
| 1664 | (B) 35 to 95 Sq. mm cable. |
| 1665 | (C) 120 to 300 Sq. mm cable. |
| 1666 | Disconnecting the cable connection and Providing T joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS. |
| 1667 | (A) up to 25 Sq mm Cable |
| 1668 | (B) 35 to 95 Sq. mm cable. |
| 1669 | (C) 120 to 300 Sq. mm cable. |
| 1670 | Supplying and erecting approved make GRP Ladder type Cable TrayMaterial – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % -Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 |
| 1671 | (A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 1672 | (B) Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 1673 | (C) Width 450 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 75Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 1674 | (D) Width 600 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 90Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 1675 | (E) Width 750 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 120Kg./Mtr. With Concentrated Load 70Kg. at center of the span |
| 1676 | Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % -- Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 -Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 |
| 1677 | (A) Width - 50mm, Pultruded “C” Channel with 30mm Sides 2.5mm Thickness, Loading 5 Kg./Mtr. |
| 1678 | (B) Width - 75mm, Pultruded “C” Channel with 25mm Sides 3 mm Thickness, Loading 7 Kg./Mtr. |
| 1679 | (C) Width - 100mm, Pultruded “C” Channel with 35mm Sides 3mm Thickness, Loading 12 Kg./Mtr. |
| 1680 | (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr. |
| 1681 | (E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr. |
| 1682 | (F) Width - 300mm, Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr. |
| 1683 | GRP Cable Trays Accessories - Manufactured from Pultruded Sections- Joining GRP Straight Coupler Plates Size: 200 x 25 x 4mm Th. with 4 sets of SS304 Hardware size: M6 X 25 for Perforated Type Tray |
| 1684 | GRP Cable Trays Accessories - Manufactured from Pultruded Sections- Joining GRP Straight Coupler Plates Size: 200 x 70 x 4mm Th. with 8 sets of SS304 Hardware size: M6 X 25 for Ladder Type Tray |
| 1685 | Supplying and erecting of Glass Fibber FilledMoulded Single Core Cable Cleats with Ms Zinc Passivated hardware having following specifications :• The material used in Single clamp is Thermoplastic, U.V Stabilized system & Glass Fibbers as reinforcement. Glass Content 15 – 30%.• It should be connected with MS Zinc passivated hardware of size M10 for clamping.• It should generally be made as per BS EN 50368/2003 specification for cable cleat for Electrical Installation.• The tensile strength of the material at yield is 800 – 1200 Kg/ cm².• The Flexural strength of the material at yield is 1000 – 1600 Kg/ cm².• The Izod Impact strength of the material at yield is 50 – 60 J/M. |
| 1686 | [A] Overall Dia of cable in mm: Min 42 to Max 46 mm Hole centre of Mounting Distance : 65 mm ± 3 mm |
| 1687 | [B] Overall Dia of cable in mm: Min 52 to Max 56 mm Hole centre of Mounting Distance : 76mm ± 5 mm |
| 1688 | [C] Overall Dia of cable in mm: Min 64 to Max 70 mm Hole centre of Mounting Distance :110mm ± 5 mm |
| 1689 | [D] Overall Dia of cable in mm: Min 85 to Max 105 mmHole centre of Mounting Distance :130mm ± 10mm |
| 1690 | Providing and fixing approved make Perforated C type cable tray.Made fromsheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall becoated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included)as per Specification and as per instruction of engineer in charge.. |
| 1691 | (1) 50 X 50X 1.6 mm Thick |
| 1692 | (2) 100 X 50 X 1.6 mm Thick |
| 1693 | (3) 150 X 50 X 1.6 mm Thick |
| 1694 | (4) 200 X 50 X 1.6 mm Thick |
| 1695 | (5) 300 X 50 X 2.0 mm Thick |
| 1696 | (6) 450 X 50 X 2.0 mm Thick |
| 1697 | (7) 600 X 50 X 2.0 mm Thick |
| 1698 | (8) 750 X 50 X 2.0 mm Thick |
| 1699 | Providing and fixing approved make \"T\" Junction for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. OF FOLLOWING SIZE |
| 1700 | (1) 50 X 50X 1.6 mm Thick |
| 1701 | (2) 100 X 50 X 1.6 mm Thick |
| 1702 | (3) 150 X 50 X 1.6 mm Thick |
| 1703 | (4) 200 X 50 X 1.6 mm Thick |
| 1704 | (5) 300 X 50 X 2.0 mm Thick |
| 1705 | (6) 450 X 50 X 2.0 mm Thick |
| 1706 | (7) 600 X 50 X 2.0 mm Thick |
| 1707 | (8) 750 X 50 X 2.0 mm Thick |
| 1708 | Providing and fixing approved make \"90° Elbow\" for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1709 | (1) 50 X 50X 1.6 mm Thick90° Elbow |
| 1710 | (2)100 X 50 X 1.6 mm Thick90° Elbow |
| 1711 | (3)150 X 50 X 1.6 mm Thick90° Elbow |
| 1712 | (4)200 X 50 X 1.6 mm Thick90° Elbow |
| 1713 | (5) 300 X 50 X 2.0 mm Thick90° Elbow |
| 1714 | (6) 450 X 50 X 2.0 mm Thick90° Elbow |
| 1715 | (7) 600 X 50 X 2.0 mm Thick90° Elbow |
| 1716 | (8) 750 X 50 X 2.0 mm Thick90° Elbow |
| 1717 | Providing and fixing approved make \"Cross over Junction\" for Perforated C type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1718 | (1)50 X 50X 1.6 mm ThickCross Junction |
| 1719 | (2)100 X 50 X 1.6 mm ThickCross Junction |
| 1720 | (3)150 X 50 X 1.6 mm ThickCross Junction |
| 1721 | (4)200 X 50 X 1.6 mm ThickCross Junction |
| 1722 | (5)300 X 50 X 2.0mm ThickCross Junction |
| 1723 | (6)450 X 50 X 2.0 mm ThickCross Junction |
| 1724 | (7)600 X 50 X 2.0 mm ThickCross Junction |
| 1725 | (8)750 X 50 X 2.0 mm ThickCross Junction |
| 1726 | Providing and fixing approved make Perforated C type cable tray.Made from pre- galvanizedsheet steel. The cable tray should be bended as per IS 2062/1079 .with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1727 | (1)50 X 50X 1.5 mm Thick |
| 1728 | (2)100 X 50 X 1.5 mm Thick |
| 1729 | (3)150 X 50 X 1.5 mm Thick |
| 1730 | (4)200 X 50 X 1.5 mm Thick |
| 1731 | (5)300 X 50 X 1.5 mm Thick |
| 1732 | (6)450 X 50 X 1.5 mm Thick |
| 1733 | (7)600 X 50 X 1.5 mm Thick |
| 1734 | (8)750 X 50 X 1.5 mm Thick |
| 1735 | Providing and fixing approved make \"T\" Junction for Perforated C type cable tray.Made from pre galvanizedsheet steel. The Junction should be bended as per IS 2062/1079. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1736 | T\"Junction |
| 1737 | (1)50 X 50X 1.6 mm Thick\" T\"Junction |
| 1738 | (2)100 X 50 X 1.6 mm Thick \" T\"Junction |
| 1739 | (3)150 X 50 X 1.6 mm Thick \" T\"Junction |
| 1740 | (4)200 X 50 X 1.6 mm Thick \" T\"Junction |
| 1741 | (5)300 X 50 X 2.0 mm Thick \" T\"Junction |
| 1742 | (6)450 X 50 X 2.0 mm Thick \" T\"Junction |
| 1743 | (7)600 X 50 X 2.0 mm Thick \" T\"Junction |
| 1744 | (8)750 X 50 X 2.0 mm Thick \" T\"Junction |
| 1745 | Providing and fixing approved make \"90° Elbow\" for Perforated C type cable tray.Made from pre galvanizedsheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1746 | 90° Elbow |
| 1747 | (1)50 X 50X 1.6 mm Thick90° Elbow |
| 1748 | (2)100 X 50 X 1.6 mm Thick90° Elbow |
| 1749 | (3)150 X 50 X 1.6 mm Thick90° Elbow |
| 1750 | (4)200 X 50 X 1.6 mm Thick90° Elbow |
| 1751 | (5)300 X 50 X 2.0 mm Thick90° Elbow |
| 1752 | (6)450 X 50 X 2.0 mm Thick90° Elbow |
| 1753 | (7)600 X 50 X 2.0 mm Thick90° Elbow |
| 1754 | (8)750 X 50 X 2.0 mm Thick90° Elbow |
| 1755 | Providing and fixing approved make \"Cross over Junction\" for Perforated C type cable tray.Made from pre galvanizedsheet steel. The Junction should be bended as per IS 2062/1079with max 17.5% perforation and shall be coated with hot dip galvanizing as per IS 2629/4759.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1756 | Cross Junction |
| 1757 | (1)50 X 50X 1.6 mm ThickCross Junction |
| 1758 | (2)100 X 50 X 1.6 mm ThickCross Junction |
| 1759 | (3)150 X 50 X 1.6 mm ThickCross Junction |
| 1760 | (4)200 X 50 X 1.6 mm ThickCross Junction |
| 1761 | (5)300 X 50 X2.0 mm ThickCross Junction |
| 1762 | (6)450 X 50 X 2.0 mm ThickCross Junction |
| 1763 | (7)600 X 50 X 2.0 mm ThickCross Junction |
| 1764 | (8)750 X 50 X 2.0 mm ThickCross Junction |
| 1765 | Providing and fixing approved make Ladder type cable tray.Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section.Rungs of members welded to the base of the longitudinal members at250 mmc/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1766 | (1)150 X 50 X 1.6 mm Thick |
| 1767 | (2)200 X 50 X 1.6 mm Thick |
| 1768 | (3)300 X 50 X 2.0 mm Thick |
| 1769 | (4)400 X 50 X 2.0 mm Thick |
| 1770 | (5)500 X 50 X 2.0 mm Thick |
| 1771 | (6)600 X 50 X 2.0 mm Thick |
| 1772 | (7)700 X 50 X 2.0 mm Thick |
| 1773 | (8)150 X 100 X 1.6 mm Thick |
| 1774 | (9)200 X 100 X 1.6 mm Thick |
| 1775 | (10)300 X 100 X 2.0 mm Thick |
| 1776 | (11)400 X 100 X 2.0 mm Thick |
| 1777 | (12)500 X 100 X 2.0 mm Thick |
| 1778 | (13)600 X 100 X 2.0 mm Thick |
| 1779 | (14)700 X 100 X 2.0 mm Thick |
| 1780 | (15)800 X 100 X 2.0 mm Thick |
| 1781 | (16)900 X 100 X 2.0 mm Thick |
| 1782 | Providing and fixing approved make \"T\" Junction for ladder type cable tray.Made from M.Ssheet steel. The Junction should be bended as per IS 2062/1079.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1783 | T\"Junction |
| 1784 | (1)150 X 50 X 1.6 mm Thick\"T\"Junction |
| 1785 | (2)200 X 50 X 1.6 mm Thick\"T\"Junction |
| 1786 | (3)300 X 50 X 2.0 mm Thick \"T\"Junction |
| 1787 | (4)400 X 50 X 2.0 mm Thick \"T\"Junction |
| 1788 | (5)500 X 50 X 2.0 mm Thick \"T\"Junction |
| 1789 | (6)600 X 50 X 2.0 mm Thick \"T\"Junction |
| 1790 | (7)700 X 50 X 2.0 mm Thick \"T\"Junction |
| 1791 | (8)150 X 100 X 1.5 mm Thick \"T\"Junction |
| 1792 | (9)200 X 100 X 1.5 mm Thick \"T\"Junction |
| 1793 | (10)300 X 100 X 2.0 mm Thick \"T\"Junction |
| 1794 | (11)400 X 100 X 2.0 mm Thick \"T\"Junction |
| 1795 | (12)500 X 100 X 2.0 mm Thick \"T\"Junction |
| 1796 | (13)600 X 100 X 2.0 mm Thick \"T\"Junction |
| 1797 | (14)700 X 100 X 2.0 mm Thick \"T\"Junction |
| 1798 | (15)800 X 100 X 2.0 mm Thick \"T\"Junction |
| 1799 | (16)900 X 100 X 2.0 mm Thick \"T\"Junction |
| 1800 | Providing and fixing approved make \"90° Elbow\" for ladder type cable tray.Made from M.Ssheet steel. The Junction should be bended as per IS 2062/1079.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1801 | (1)150 X 50 X 1.6 mm Thick |
| 1802 | (2)200 X 50 X 1.6 mm Thick |
| 1803 | (3)300 X 50 X 2.0 mm Thick |
| 1804 | (4)400 X 50 X 2.0 mm Thick |
| 1805 | (5)500 X 50 X 2.0 mm Thick |
| 1806 | (6)600 X 50 X 2.0 mm Thick |
| 1807 | (7)700 X 50 X 2.0 mm Thick |
| 1808 | (8)150 X 100 X 1.6 mm Thick |
| 1809 | (9)200 X 100 X 1.6 mm Thick |
| 1810 | (10)300 X 100 X 2.0 mm Thick |
| 1811 | (11)400 X 100 X 2.0 mm Thick |
| 1812 | (12)500 X 100 X 2.0 mm Thick |
| 1813 | (13)600 X 100 X 2.0 mm Thick |
| 1814 | (14)700 X 100 X 2.0 mm Thick |
| 1815 | (15)800 X 100 X 2.0 mm Thick |
| 1816 | (16)900 X 100 X 2.0 mm Thick] |
| 1817 | Providing and fixing approved make \"Cross over Junction\" for ladder type cable tray.Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759.with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing supportas per Specification and as per instruction of engineer in charge.. |
| 1818 | (1)150 X 50 X 1.6mm Thick |
| 1819 | (2)200 X 50 X 1.6 mm Thick |
| 1820 | (3)300 X 50 X 2.0 mm Thick |
| 1821 | (4)400 X 50 X 2.0 mm Thick |
| 1822 | (5)500 X 50 X 2.0 mm Thick |
| 1823 | (6)600 X 50 X 2.0 mm Thick |
| 1824 | (7)700 X 50 X 2.0 mm Thick |
| 1825 | (8)150 X 100 X 1.6 mm Thick |
| 1826 | (9)200 X 100 X 1.6 mm Thick |
| 1827 | (10)300 X 100 X 2.0 mm Thick |
| 1828 | (11)400 X 100 X 2.0 mm Thick |
| 1829 | (12)500 X 100 X 2.0 mm Thick |
| 1830 | (13)600 X 100 X 2.0 mm Thick |
| 1831 | (14)700 X 100 X 2.0 mm Thick |
| 1832 | (15)800 X 100 X 2.0 mm Thick |
| 1833 | (16)900 X 100 X 2.0 mm Thick |
| 1834 | Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM |
| 1835 | [A] 305 mm dia 900 RPM |
| 1836 | Cat.I |
| 1837 | Cat.II |
| 1838 | [B] 380 mm dia 900 RPM |
| 1839 | Cat.I |
| 1840 | Cat.II |
| 1841 | [C] 380 mm dia 1400 RPM |
| 1842 | Cat.I |
| 1843 | Cat.II |
| 1844 | [D] 450 mm dia 900 RPM |
| 1845 | Cat.I |
| 1846 | Cat.II |
| 1847 | [E] 450 mm dia 1400 RPM |
| 1848 | Cat.I |
| 1849 | Cat.II |
| 1850 | Providing suitable M.S. louver shutter of the Exhaust fan. |
| 1851 | Supplying & erecting electro galvanised G.I. wire micro mesh jali cover of grade 304 required size with suitable wooden frame duly fitted in wall outside of exhaust fan for insect protection. |
| 1852 | Providing recess in wall or window frame suitable for erection of Exhaust fan complete with plastering and colour washing to match the colour of the wall or window complete with expanded metal in order to render the fitting in accessible and the room water-proof. |
| 1853 | Providing window frame suitable for erection of Exhaust fan complete covering the remaining portion of window with 15 mm. thick plywood and colour washing to match the colour of the wall. |
| 1854 | Supplying approved make heat convector two speed motor, thermal cut-out complete with necessary lead Core and plug top. |
| 1855 | Supplying & erecting Galvanized M.Spipe post “B” class 88.9 mm O.D4 mtr. Long duly painted with two coats ofaluminium paint complete with metallic base plate of 300 mm x 300 mm x 4mm thick for using as a compound light pole with approx. weight 32 Kg. |
| 1856 | Supplying & erecting Galvanized M.S pipe post “B” class 88.9 mm O.D 6 mtr. Long duly painted with two coats of aluminium paint complete with metallic base- plate of 300 mm x 300 mm x 4mm thick for usingas a compound light pole with approx. weight 47 Kg. |
| 1857 | Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II) 1980. Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube should beISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat of Aluminium /approvedpaint to be erected on / in existing Foundation. The length of poles are as below. |
| 1858 | (A) 7.5 mtr. Long Swaged Steel tubular pole |
| 1859 | (i)pole as per IS code 410-SP-4 with 300 X 300 X 4 mm base plate. (Approximate Pole weight 67 Kg) For burialerection |
| 1860 | (ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, Suitable for mounting on surface of foundation with GI foundation bolts, with required stiffeners welded with pole. |
| 1861 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1862 | (B) 8.5 mtr. Long Swaged Steel tubular pole |
| 1863 | (i)Pole as per IS code 410-SP-16 with 300 X 300 X 4 mm base plate. (Approximate weight 75 Kg) For burialerection |
| 1864 | (ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1865 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1866 | ( C ) 9.0 mtr. Long Swaged Steel tubular pole |
| 1867 | (i)Pole as per IS code 410-SP-25 with 300 X 300 X 4 mm base plate. (Approximate weight 78 Kg) For burialerection |
| 1868 | (ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1869 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1870 | (D) 10.00 mtr. Long Swaged Steel tubular pole |
| 1871 | (i) Pole as per IS code 410-SP-40 with 300 X 300 X 6 mm base plate.(Approximate weight 128 Kg) For burialerection |
| 1872 | (ii) ADD Extra for M.S. Base plate 300 X 300 X 16 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1873 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1874 | (E) 11.00 mtr. Long Swaged Steel tubular pole |
| 1875 | (i) pole as per IS code 410-SP-49 with 350 X 350 X 6 mm base plate. (Approximate weight 140 Kg)For burialerection |
| 1876 | (ii) Add Extra for M.S. Base plate 400 X 400 X 16 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1877 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1878 | (F) 12.00 mtr. Long Swaged Steel tubular pole as per IS code 410-SP-58 with 450 X 450 X 6 mm base plate (Approximate weight 186 Kg) For burialerection |
| 1879 | (ii) ADD Extra for M.S. Base plate 400 X 400 X 16 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1880 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1881 | (G) 13.00 mtr. Long Swaged Steel tubular Pole |
| 1882 | (i) pole as per IS code 410-SP-67 with 450 X 450 X 6 mm base plate. (Approximate weight 261 Kg) For burialerection |
| 1883 | (ii) ADD Extra for M.S. Base plate 450 X 450 X 20 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1884 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1885 | (H) 16.00 mtr. Long Swaged Steel tubular pole |
| 1886 | (i) Poleas per IS code 410-SP-77 with 450 X 450 X 10 mm base plate. (Approximate weight 341 Kg)For burialerection |
| 1887 | (ii) Add Extra for M.S. Base plate 500 X 500 X 20 mm for pole, mounting on surface of foundation on foundation bolt. with required stiffeners. |
| 1888 | (iii) Add Extra for PU base primer and PU Paint on pole. |
| 1889 | Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminationto be erected on foundation as per details given by manufacturer considering site requirement. |
| 1890 | (A) 3 Mtr. Long 70 mm TopX 130 mm bottom dia.3 mm thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and 450mm long J-Bolt. |
| 1891 | (B) 4 Mtr. Long 70 mm TopX 130 mm bottom dia, 3 mm thicknesswith 200mmX200mmX12mm base plate, 4-M16 Bolts and 450mm long J-Bolt. |
| 1892 | ( C ) 5 Mtr. Long 70 mm TopX 130 mm bottom dia, 3 mm thicknesswith 200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm long J-Bolt. |
| 1893 | (D) 6 Mtr. Long 70 mm TopX 135 mm bottom dia, 3 mm thicknesswith 200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long J-Bolt. |
| 1894 | (E) 7 Mtr. Long 70 mm TopX 135 mm bottom dia, 3 mm thicknesswith 225mmX225mmX16mm base plate, 4-M20 Bolts and 600mm long J-Bolt. |
| 1895 | (G) 8 Mtr. Long 70 mm TopX 155 mm bottom dia, 3 mm thicknesswith 260mmX260mmX16mm base plate, 4-M20 Bolts and 600mm long J-Bolt. |
| 1896 | (H) 9 Mtr. Long 70 mm TopX 155 mm bottom dia, 3 mm thickness with 260mmX260mmX16mm base plate, 4-M24 Bolts and 750mm long J-Bolt. |
| 1897 | (I) 10 Mtr. Long 70 mm TopX 175 mm bottom dia, 4 mm thickness with 275mmX275mmX16mm base plate, 4-M24 Bolts and 750mm long J-Bolt. |
| 1898 | (J) 11 Mtr. Long 90 mm TopX 210 mm bottom dia, 4 mm thickness with 300mmX300mmX20mm base plate, 4-M24 Bolts and 750mm long J-Bolt. |
| 1899 | (K) 12 Mtr. Long 90 mm TopX 240 mm bottom dia, 4 mm thickness with 320mmX320mmX20mm base plate, 4-M24 Bolts and 850mm long J-Bolt. |
| 1900 | Supplying and erecting approved make Conical Pole (Standard ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759 with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminationas erected on suitable foundation (included) with necessary nut-bolts/J-Bolts.as per details given by manufacturer considering site requirement.The length of poles are as below. |
| 1901 | (A) 3 Mtr. Long 65mm Top X110 mm bottom dia,3mm thickness. |
| 1902 | (B) 4 Mtr. Long 65mm Top X125 mm bottom dia, 3mm thickness. |
| 1903 | (C) 5 Mtr. Long 65mm Top X140 mm bottom dia, 3mm thickness. |
| 1904 | (D) 6 Mtr. Long 65mm Top X155 mm bottom dia, 3mm thickness. |
| 1905 | (E) 7 Mtr. Long 65mm Top X170 mm bottom dia, 3mm thickness. |
| 1906 | (F) 8 Mtr. Long65mm Top X185 mm bottom dia, 3mm thickness. |
| 1907 | (G) 9 Mtr. Long65mm Top X200 mm bottom dia, 3mm thickness. |
| 1908 | (H) 10 Mtr. Long 70mm Top X220 mm bottom dia, 3mm thickness. |
| 1909 | (I) 11 Mtr. Long70mm Top X235 mm bottom dia, 3mm thickness. |
| 1910 | (J) 12 Mtr. Long 70mm Top X250 mm bottom dia, 3mm thickness. |
| 1911 | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminationsas erected on suitable foundation (included) with necessary nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below. |
| 1912 | (A) 3 Mtr. Long 70 mm Top X 115 mm bottom dia,3 mm thickness. |
| 1913 | (B) 4 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness. |
| 1914 | (C) 5 Mtr. Long 70 mm Top X 145 mm bottom dia, 3 mm thickness. |
| 1915 | (D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness. |
| 1916 | (E) 7 Mtr. Long 70 mm Top X 175 mm bottom dia, 3 mm thickness. |
| 1917 | (F) 8 Mtr. Long 70 mm Top X 190 mm bottom dia, 3 mm thickness. |
| 1918 | (G) 9 Mtr. Long 70 mm Top X 205 mm bottom dia, 3 mm thickness. |
| 1919 | (H) 10 Mtr. Long 80 mm Top X 220 mm bottom dia, 3 mm thickness. |
| 1920 | (I) 11 Mtr. Long 80 mm Top X 245 mm bottom dia, 3 mm thickness. |
| 1921 | (J) 12 Mtr. Long 80 mm Top X 260 mm bottom dia, 3 mm thickness. |
| 1922 | Supplying and erecting C.I. pole base Suitable for following size ofpole with M.S.door having two hinges welded on M.S.flat 25 x 3 mm which is fitted on C.I. base by bolts welded inside the pole base erected with one coat of’ Red oxide and two coat of Aluminium paint and covering the gap between pole and pole base with suitable clamp as per SOR drawing or sample. |
| 1923 | (A) Suitable for 90 mm.dia base of pole |
| 1924 | (B)Suitable for 114 mm.dia base ofpole |
| 1925 | (C) Suitable for 140 mm.dia base of pole |
| 1926 | Supplying and erecting Pole base suitable forfollowing size of pole fabricated from 4 mm. Thick M.S. sheet with M.S.door having two hinges welded on M.S. flat 25 x 3 mm which is fitted on M.S..base by bolts welded inside the pole base erected with one coat of Red oxide and two coats of Aluminium paint. Outside dimension as per SOR. drawing. |
| 1927 | (A) Suitable for 90 mm. dia.base of pole |
| 1928 | (B) Suitable for 114 mm. dia.base of pole |
| 1929 | (C) Suitable for 140 mm. dia.base of pole |
| 1930 | Providing and fixing pole base cover fabricated from 16 SWG M.S. sheet having adequate size to cover pole base and having bend as per curvature of pole base, making the holes to fix the cover to bolt at one. end and other end shall be welded by the hinges fabricated from M.S. strip as per sample both the hinges shall be welded on M.S.strip which shall be drilled to fix on pole base. the complete assembly shall be fixed on pole base by drilling holes on pole base and painting, by one coat of Red oxide and two coats of aluminium paint. |
| 1931 | Providing nd erecting C.I./M.S. flange type base plate of300mm x 300mm x 6mm |
| 1932 | Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with suitable brass studs with nuts, washers and clamps of size 25mm x 3mm suitable for pole painted with one coat of red lead paint. |
| 1933 | Providing and erecting cable clamp of25 mm X 3 mm M.S. flat suitable for fixing 2 Nos.of armoured cable with nuts and bolts. |
| 1934 | (A) for 114 mm dia. Pole |
| 1935 | (B) for 140 mm dia. Pole |
| 1936 | (C) for 165 / 195 mm dia. Pole |
| 1937 | Providing1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner.( for 4 & 6 mtr pole) |
| 1938 | Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 120 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner. ( for 7.5 & 8/8.5 mtr pole) |
| 1939 | Providing1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 150 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) high upper ground levelwith necessary curing and finishing in approved manner.( for 9 & 10mtr pole) |
| 1940 | Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 90 x 90 x 180 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) high upper level groundcement concrete with necessary curing and finishing in approved manner [above 11 mtr & above poles] |
| 1941 | Providingcement concrete.foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose. |
| 1942 | Providingcement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose. |
| 1943 | Excavating hard rock or bituminous road (B.T.) by chiselling or using tool and tackles for preparing pit for poles or earth plates or for laying pipes & clearing the site by removing debris & making site good. |
| 1944 | Excavating hard Murrumor Metalroad by chiselling for preparing pit for poles or earth plates or for laying pipes & clearing the site by removing debris & making site good. |
| 1945 | Providing burnt brick masonry with 1:6 cement concrete duly plastered including watering, stacking joint on exposed faces, rocking at joints on exposed faces and watering complete |
| 1946 | Note: For Item No 6.3.9 & 6.3.10 if additional machinery like hammer, driller or JCB used add 10% extra in rate. |
| 1947 | Supplying and erecting Water tight M.S.Box of size20 x 15 x 15 cm.to erect suitable kitkat fuse / MCBto be . erected on polished wooden board inside the boxwith hinged/sliding door with rubber rings and erected on pole with suitable pole clamp, all duly painted with one coat of red oxide and two coats of paints. (Cost of Fuse / MCB shall be taken extra) |
| 1948 | Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S. sheet havingfollowing size complete with fixing arrangement for terminal board, with necessary hole for wire entry and exit from the box. The box shall be provided with cover and hinges on one side and bolting at other end The box shall be fixed by clamps fabricated from 25mm x 6mm flat.The box shall be painted with one coat of red oxide and two coats of paint having following box size. 330 mm x 260 mm x 140 mm (depth) |
| 1949 | Supplying & erectingapproved makeSMC press moulded composite FRP.loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting mob& hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box. |
| 1950 | (A) 300mm x 200mm x 100mm[deep] |
| 1951 | (B) 250mm x 200mm x 100mm [deep] |
| 1952 | (C)150mm x 125mm x 100mm [deep] |
| 1953 | (D) 140mm x 140mm x 100mm[deep] |
| 1954 | (E) 200mm x 140mm x 125mm[deep] |
| 1955 | (F) 200mm x 180mm x 100mm[deep] |
| 1956 | (G) 250mm x 220mm x 135mm[deep] |
| 1957 | (H) 300mm x 200mm x 135mm[deep] |
| 1958 | (I) 400mm x 300mm x 190mm[deep] |
| 1959 | (J) 505mm x 240mm x 160mm[deep] |
| 1960 | (K) 700mm x 480mm x 210mm[deep] |
| 1961 | Supplying & erectingapproved make street light box comprising CNC Processed robust housing made from single sheet multi folded with high grade powder coating ( RAL-7032 Structure finish as Standard) of IP-55 degree of Protection Gasket(PU Gasketing) of following size of Box. |
| 1962 | (A) 350mm X 200 mm X 150 mm |
| 1963 | (B) 300mm X 200 mm X 150 mm |
| 1964 | (C) 200mm X 150 mm X 100 mm |
| 1965 | Providing & erecting approved make street light / wall mounting junction box compression moulded from SMC (thermoset plastic) vertical sliding cover having locking with square head stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P. 54 protected with clamp or bolt nut & earth bolt of following size. |
| 1966 | [A] 200mm x 127mm x 83 mm |
| 1967 | [B] 250mm x 194mm x 99 mm |
| 1968 | [C] 327mm x 254mm x 120 mm |
| 1969 | Supplying and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5mm/80mm or require size pole top having sufficient fastners for fixing the brackets and having suitable rise as per site condition as directed and spread of 2 mtr.with suitable welded stiffener reducer and with lock nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. Suitable for side entry fitting brackets of following nos of arms. |
| 1970 | [A] Single Arm bracket 2 Mtr |
| 1971 | [B] Double Arm Bracket 2 Mtr. |
| 1972 | [C] Triple Arm Bracket 2 Mtr. |
| 1973 | [D] Four Arm bracket 2 Mtr. |
| 1974 | Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. |
| 1975 | [A] Single Arm Bracket 1.5 Mtr |
| 1976 | [B] Double Arm Bracket 1.5 Mtr |
| 1977 | [C] Triple Arm Bracket 1.5 Mtr |
| 1978 | [D] Four Arm Bracket 1.5 Mtr |
| 1979 | Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B class M.S. sleeve tubing of approximate 45 cms. length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fastners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. |
| 1980 | [A] Single Arm bracket 1 Mtr |
| 1981 | [B] Double Arm Bracket 1 Mtr |
| 1982 | [C] Three Arm Bracket 1 Mtr |
| 1983 | [D] Four Arm Bracket 1 Mtr |
| 1984 | Supplying and erecting Street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5mm/80mm/require size of pole top having nuts and bolts for fixing the brackets and having spread of 0.5 mtr. Length with 110 deg.with vertical plane and suitable welded stiffener reducer and nipple with check nut complete painted with one coat.of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. |
| 1985 | [A] Single Arm bracket 0.5 Mtr |
| 1986 | [B] Double Arm Bracket 0.5 Mtr |
| 1987 | [C] Three Arm Bracket 0.5 Mtr |
| 1988 | [D] Four Arm Bracket 0.5 Mtr |
| 1989 | Supplying and erecting B class Galvanized iron pipe having smooth finished bore of the pipe on both ends erectednuts and boltsalong the pole / wall shaping the pipe as per site requirement. Pipe dia as following. |
| 1990 | (A) 25 mmdia |
| 1991 | (B) 32 mm dia |
| 1992 | (C) 40 mm dia. |
| 1993 | (D) 50 mm dia. |
| 1994 | (E) 65 mm dia. |
| 1995 | (F) 80 mm dia. |
| 1996 | Supplying and erecting B class galvanised iron pipe 32 mm outside dia 45 cm long duly welded on 20 cm x 20 cm x 3 mm thick M.S. base plate, erected on wall or corner for mounting street light luminaire with necessary hardware materials duly painted. |
| 1997 | Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. |
| 1998 | Supplying & erecting approved make time switch with single pole air break contacts suitable for 230 V.15/16A.complete with self starting motor driven clock ‘ON’ &’ OFF’ automatic arrangement at any predetermined time during each 24 hours,With nickel cadmium rechargeable battery backup erected as directed. |
| 1999 | Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed. |
| 2000 | Supplying and erecting approved make Segment time switch suitable for 230V+10%16A. floating contacts with 24 hour dial having15/30 min. segments with early manual override switching for on & off without influencing the program sequence with quartz time switch With power reserve, housed in fire proof thermoplastic enclosure & transparent cover terminal covers erected as required wire necessary connection erected as directed. |
| 2001 | Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. |
| 2002 | Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per direction Cat III |
| 2003 | [A] 2 Pole 250V 12 Amp. |
| 2004 | [B] 2 pole 250V 32 Amp. |
| 2005 | [C] 4 pole 440V 16 Amp. |
| 2006 | [D] 4 pole 440V 40 Amp. |
| 2007 | Supplying & erecting approved make IP 55 grade Company fabricated Timer Panel of following capacityfor switch On-Off street lights on time scheduling basis made from 16G CRCA sheet duly epoxy power painted inside and outside with hinged doors and locking arrangement consisting of suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with analog time switch, auto manual switch of same make andsuitableinput and output Bakelite terminals and with door earthing approved by Engineer in charge. |
| 2008 | [A] 32 Amp |
| 2009 | [B] 40 Amp |
| 2010 | [C] 63 Amp |
| 2011 | Supplying and erecting approved make Analog type voltmeter moving iron withsquare/ RoundDial, flush/pedestalmounting pattern for A.C.Voltage 0 to 500 Volt range, erected on panel board with all connection, wiring etc. |
| 2012 | Supplying and erecting approved make panel mounting typeDigital Voltmeter having 3 digits LED display, 0 to 750 AC Volts rangeerected on existingpanel board with all connection, wiring etc .with manufacturers calibration certificate. |
| 2013 | Supplying and erecting approved make Analog type moving iron Ammeter direct reading type 0-30A AC current, 500V square/Round dial, flush or projection type complete erected with connection and wiring. |
| 2014 | Supplying and erecting approved make panel mounting typeDigital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existingpanel board with all connection, wiring etc .with manufacturers calibration certificate. |
| 2015 | Supplying and erecting approved make Analog type moving iron C.T operated Ammeter A C Current suitable slide in scale 0- 400 Amp. with 3 Nos. of Current Transformer erected on panel board with connections. |
| 2016 | Supplying and erecting Ammeter / Voltmeterselector switch for 3 phase AC Supply 500 V on existing panel board with necessary connections. |
| 2017 | Providing & erectingL.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with insulating materials connected to the meter |
| 2018 | Supplying & erecting approved make Power Factor Meter 150mm dia flush/projection type/ balanced & unbalanced load to work with appropriately provided CT’s 100/5A to 400/5A ratio & other accessories complete erected in M.S. box & connected to the circuit by means of PVC copper Core leads. |
| 2019 | Supplying and erecting approved make suitable panel indicator lamps of LED type lamp, lens cover, Bakelite holder complete erected with necessary connections. |
| 2020 | Supplying & erecting directly operated single phasing preventer complete erected and connected to supply up to 45 Amp. Range. |
| 2021 | Supplying & fixing Steel Chequered Plate having 7 mm thickness, duly painted with two coats of black Japan colour. (Average Wt61.1 kg / Sq.Mtr) |
| 2022 | Supplying & fixing Steel Chequered Plate having 10 mm thickness,with handleduly painted with two coats of black Japan colour. (Average Wt84.6 kg / Sq.Mtr) |
| 2023 | Supplying & fixing Steel Chequered Plate having 12 mm thickness, duly painted with two coats of black Japan colour. (Average Wt200.3kg / Sq.Mtr) |
| 2024 | Supplying & Fixing SMC Chequered plate having 7 mm thickness, made out of SMC Confirming to IS 13410 & by Hot press Compression Moulding technique Suitable cut & fixed with MS Angle Frame to Fit Trench Widths as per site requirement approved .by engineer incharge |
| 2025 | Supplying & Fixing SMC Chequered plate having 10 mm thickness, made out of SMC Confirming to IS 13410 & by Hot press Compression Moulding technique Suitable cut & fixed with MS Angle Frame to Fit Trench Widths as per site requirement approved by engineer incharge |
| 2026 | Supplying & Fixing SMC Chequered plate having 12 mm thickness, made out of SMC Confirming to IS 13410 & by Hot press Compression Moulding technique Suitable cut & fixed with MS Angle Frame to Fit Trench Widths as per site requirement approved .by engineer incharge |
| 2027 | Dismantling the existing light, fan, bell, , independent plug point, wiring with mains of all types along with accessories etc. complete and handed over to dept. |
| 2028 | Refilling the holes for dismantled point with cable with cement mortar & finishing in an approved manner. |
| 2029 | Dismantling the existing cables of all types & sizes |
| 2030 | Dismantling the existing underground cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete to be placed at different store. |
| 2031 | Re-erecting PVC armoured cable 2 to 4 core up to 50 sq.mm on wall / pipe with necessary material & G.I. earth wire in an approved manner. |
| 2032 | Dismantling the existing switchgears, DB and Busbar of any size complete with / without board or angle iron frame. |
| 2033 | Dismantling existing DO / AB switch set complete on D.P. structure in an approved manner. |
| 2034 | Dismantling existing OCB, ACB complete from existing panel board in an approved manner.Note:- Dismantled switchgears breakers to be handed to the Section In charge. |
| 2035 | Dismantling existing lightening arrestor set, insulator complete from DP structure in approved manner. |
| 2036 | Dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with accessories, G.I. down rod, frame etc. and making the site clear. |
| 2037 | Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 2038 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 2039 | Dismantling the existing any type of indoor light fittings |
| 2040 | Dismantling the existing any type of street light fittings on pole up to 6 mt height with bracket and making the site as original complete. |
| 2041 | Dismantling the existing any type of fittings above 6 mt height pole from pole with bracket complete. |
| 2042 | Dismantling the existing electric geyser or storage type water heater of any size along with plumbing connection and making the site clear. |
| 2043 | Dismantling the existing Distribution Transformer /D.G. Set of any capacity from the plinth / foundation safely without any damages and storing it in safe place. |
| 2044 | Dismantling existing pole mounted Distribution Transformer safely without any damages and storing it in safe place. |
| 2045 | Dismantling the existing window type air conditioner of any type and capacity safely without any damages and making the site clear. |
| 2046 | Dismantling the existing split type air conditioner of any type and capacity safely without any damages and making the site clear. |
| 2047 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 2048 | Upto 35 sq. mm |
| 2049 | Above 35 sq. mm and upto 95 sq. mm |
| 2050 | Above 95 sq. mm and upto 185 sq. mm |
| 2051 | Above 185 sq. mm and upto 400 sq. mm |
| 2052 | Only laying (For departmentally supplied cables at site) of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation of 90 cms deep, sand cushioning, protective covering with bricks and refilling the trench etc. as required. |
| 2053 | Up to 35 sq. mm |
| 2054 | Above 35 sq. mm and up to 95 sq. mm |
| 2055 | Above 95 sq. mm and up to 185 sq. mm |
| 2056 | Above 185 sq. mm and up to 400 sq. mm |
| 2057 | Only laying (For departmentally supplied cables at site) and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 2058 | Up to 35 sq. mm (clamped with 1mm thick saddle) |
| 2059 | Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 2060 | Above 95 sq. mm and up to 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 2061 | Above 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 2062 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation of 90 cms deep, sand cushioning, protective covering with bricks and refilling the trench etc. as required. |
| 2063 | Up to 120 sq. mm |
| 2064 | Above 120 sq. mm and up to 400 sq. mm |
| 2065 | Only installation of following types of lighting fixtures along with required accessories complete |
| 2066 | Installation of outdoor light fixtures |
| 2067 | Installation of Building light fixtures |
| 2068 | Installation of Retrofit tube lights |
| 2069 | Installation of tube lights with batten |
| 2070 | Supply and fixingof 20W LED Tube light (Tube rod only),PF>0.95, CRI>=80, Life-30000 hrs., IP20, 220 V-240V, LED chip wattage-1 W, Luminaire efficacy>=100 lumens/W, CCT: 6000K cool white & 2700 to 3000 K for warm white, Surge protection device-up to 2.5 KV |
| 2071 | Supply and erecting approved make open type Vertical medium bay LED Luminaire with high power LED as light source white coloured ABS housing withaluminium heat sink fins for efficient heat dissipation, beam angle 120 degree, high quality polycarbonate transparent cover for comfortable lighting, spun aluminium reflector sand blasted outside and inside and electrochemically brightened,having constant current driver ,inbuilt surge protection,, colour Temp (5000K-6500K), IP 66 Rated power 50-60 Watt with minimum rated luminous flux 3300Lmn. LM 79 & LM 80 report required. Minimum warranty 2 years. |
| 2072 | Supply and erecting 35 W LED Bulk Head NFLP, power factor >0.95, CRI>80, CCT- 5700 to 6500 K, Life test/burning hours - 50000, IP-66, Voltage - 110-320 V, LED chip efficacy>135 lm/Watt, Driver efficacy >85%, System efficacy ->100 lm/W, Surge protection device (Internal) - 4 KV, (External) - 10 KA, 20 KV, Make-Philips/CG |
| 2073 | Supplying and erecting 190 - 210W NFLP LED flood light with efficiency more than 100 lm/w, voltage rating 110 to 320 V, Power factor more than 0.95, THD < 10 %,CCT 5700 K to 6500 K,Luminaire efficiency > 85 % IP 66, CRI>70, surge protection -4kV internal, 10 KA 20kV external, and life test of 50000 hours, CRI>70 |
| 2074 | Supply of Flameproof Exhaust Fan for 230V Supply & suitable for Gas Group IIA & IIB.- 16 Inch |
| 2075 | Providing and erecting of FLP rotary switch (with or without regulator) for exhaust fan as per decision of EIC) SP-16 Amps to be erected on existing steel structure. |
| 2076 | Providing & erecting following type FLP junction box in LM-6 type complete erected on poles in place of defective with necessary mounting arrangement and two bind plugs in each junction box, as directed by electrical in charge. The FLP JB should be DGMS approved make FCG/Flexpro/GEC or other make only DGMS approved for use in hazardous area _I & II - 0.75\" ET4 or 6 way 170 mm dia. multiway |
| 2077 | Supply fixing Testing and commissioning of FLP Single phase with neutral &earth, switch socket and plug top (Receptacle) 16Amp, 250Volt,(P+N+E). |
| 2078 | Preventive maintenance of lighting fixtures/ earthing/ lighting poles, etc. for any installation as per the scope of work. |
| 2079 | SITC of FLP control Gear Box with 32A MCB, Voltmeter, Ammeter and provision for incomingand outgoing cables for Heater treater along with necessary blinds. |
| 2080 | Supplying and erecting 6 sq. mm. 316 grade wire rope for high mast tower. (20 to 30 Mtr high HM) |
| 2081 | S/I/T/C of 10 mtrs height steel tubular pole (swaged) ladder type with caged standing platform for maintenance purpose of suitable size and single ring bracket of suitable size for mounting 04 nos. LED flood light fixtures. |
| 2082 | Dismantling of old unsued high mast lighting tower and placing them in installation scrap yard after cutting, dismantling in small parts including crane, gas cutting, JCB,truck carrier etc, used for the work.High mast tower dismentaling |
| 2083 | Providing and fixing Double compression type FLP Type cable gland for 2.5/4/6/10 sq mm size PVC/XLPE insulated armoured cable. (FLP certicate to be provided) |
| 2084 | Supply & installation of 120W FLP LED flood light 100 to 300 V, driver efficiency 85%, power factor greater than 0.95, CCT 5700 K to 6500 K CRI> 70, surge protection device internal- 5kV external- 10KA & 20KV System efficiency> 90 luniens/watt, IP 66 burning hours 50000. Moulded neoprene gasket, material for construction used of LM6 standard, gas group II A, IIB and IIC and temperature class T5 stainless steel hardware, copper free die cast aluminium alloy, LM6, Cu<0.004%. heat resistant and toughened type A clear dome glass, suitable for Zone I and II operating temperature -10 to 50C CIMFR(Dhanbad/ BIS/ PESO CCOE) DGMS |
| 2085 | Supplying & erecting 90- 120W NFLP LED flood light fittings, with efficiency more than 100 lm/w, voltage rating 110 to 320V, P.F. more than 0.95, THD < 10%, CCT - 5700K to 6500K, luminaire efficiency > 85%, IP-66 rated, CRI > 70, surge protection : 4kV internal, 10kA 20kV external and life test of 50000 hours. |
| 2086 | SITC of FLP preferably DGMS approved Push Button Station 10 A along with Stand & RCC work. |
| 2087 | Disconnection/Reconnection & termination of cables from existing panel along with glands |
| 2088 | Supply fixing Testing and commissioning of FLP 4 Way Junction Box (120 mm dia) to be erected on existing steel structure. Along with necessary enclosure(blind gland) for unused glands |
| 2089 | Supplying and erecting FLP approved make well glass LEDfittings of rating 50/70 W complete with luminaire conforming to IS 2148-1981 for use in Zone-1 and Zone 2 hazardous areas of oil mines with suitable lamp |
| 2090 | Supplying and erecting 70-80 W NFLP LED street light with efficiency more than 100 lm/w, voltage rating 140 to 270 V, Power factor more than 0.95, THD < 10 %,CCT 5000 K to 5700 K,Luminaire efficiency > 85 % IP 66, CRI>70, surge protection -4kV internal, 10 KA 20kV external, and life test of 50000 hours. (warranty certificate for 3 years ) |
| 2091 | Installation of existing LED Post Top Lantern/Dome lightfittings on existingpoles. |
| 2092 | Replacement of existing any type ofstreet/ flood light/well glass fittings above 6 mt height pole. |
| 2093 | Laying ofXLPE armoured cable multistrand / SolidCopperconductor on wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof 4C x 2.5 Sqmm and 3C X 1.5 sqmm. size of cables.(a) 2 to 4 core 2.5 / 4 Sq. mm |
| 2094 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof 3 core 1.5 Sq. mm size of cable. |
| 2095 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof following size of cables.(B) 4core 35 Sq. mm |
| 2096 | Supplying, installation, testing and commissioning of indoor typeAuto Transformer Starter panel. |
| 2097 | 15 KW ATS |
| 2098 | 18.5 KW ATS |
| 2099 | 22KW ATS |
| 2100 | 30 KW ATS |
| 2101 | 37 KW ATS |
| 2102 | 45 KW ATS |
| 2103 | 55 KW ATS |
| 2104 | 75 KW ATS |
| 2105 | 90 KW ATS |
| 2106 | Providing and erecting Approved make ELCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. ratingerected as directed |
| 2107 | [a] 6A 2 pole single phase |
| 2108 | [b] 10A 2 pole single phase |
| 2109 | [c] 16A 2 pole single phase |
| 2110 | [d] 20A 2 pole single phase |
| 2111 | [e] 32A, 2 pole Single Phase |
| 2112 | Providing and erecting Approved make ELCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component for following Max. ratingerected as directed. |
| 2113 | [a] 10A, 4 Pole Three Phase |
| 2114 | [b] 16A, 4 pole Three phase |
| 2115 | [c] 20A. 4 pole Three phase |
| 2116 | [d] 32A, 4 Pole Three Phase |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail