| 1 | Excavation in foundation in ordinary soil (Loam, Clay or sand) including lift up to 1.50m and lead up to 30 as per as per s.i.no.251 |
| 2 | Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer-In-Chargewithin a distance of 60 meters (200 feet). Sor 692 |
| 3 | Providing and laying cement concrete in 1:4:8 (1cement , 4C/sand 8 s/ballast in 40mm) and curing complete i/c cost of form work in foundation and floor as per PWD s.i.no.275a ch-5 |
| 4 | Brick work with common burnt clay FPS non modular brick of class designation-100 in foundation and plinth in 1:4 cement, c/sand Sor 6.1.1 |
| 5 | Excavating, supplying and filling of local earth by mechanical transport upto a lead upto 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. S.I.No. 8 DSR No. 2.25(a) |
| 6 | Providing and laying in position specified grade of reinforcement cement concrete including the cost of centering, shuttering finishing and excluding reinforcement including supply pf all materials ,labours and T&Petc required for proper completion of the work 1:1.5:3 (1 Cement : 1.5 Coarse sand: 3 Graded stone aggregate 20 mm nominal size) .(SOR -5.1.2a) |
| 7 | Brick work with common burnt clay FPS non modular brick of class designation-100 in superstructure above plinth level in 1:4 cement, c/sand Sor 6.4.2 |
| 8 | RCC work in beam , lintels, suspended floors, roofs, having balconies, shelves, chajjas, bands, staircases, above plinth level upto floor five level, i/c the cost of centering, shuttering, finishing and excluding reinforcement -1:1.5:3 cement, coarse sand and stone aggregate 20 mm nominal size i/c all as per dsr no.5.3 sr 8 ch- 05 |
| 9 | Steel reinforcement for RCC work i/c straightening, cutting, bending all complete as DSR no.-5.22.6 CH-10 |
| 10 | Cover block for rcc work.on MR |
| 11 | 12 mm cement plaster on brick work with cement mortar 1:4 (1cement:4 coarse ) (SOR 13.4.1) |
| 12 | Finishing walls with Acrylic Smooth exterior paint (Apex) of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)DSR no.13.46.1 |
| 13 | Providing and laying cement concrete in 3:1.5:1 of not less than strength of M-15 stone Ballast (20mm nominal size) approved coarse sand and cement, curing complete, including cost of form work. In Foundation and floors. S.I.No. 4.1.2 |
| 14 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). As DSR. no.-10.28 |
| 15 | Providing and fixing 18mm thick Granite (gang saw cut) mirror polished premoulded and prepolished machine cut for kitchen platform similor location of required size approved shade, colour laid over 20 mm thick base cement mortar 1:4 cement coarse sand etc complete at all level (SOR si no. 8b ch-14) |
| 16 | Providing and fixing red sand stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixtureof pigment , matching the stone shade, jali slab without any chamfers etc. dsr 7.33.1 PWD SR. 3 |
| 17 | Supply and fixing of precast cement concrete sitting bench i/c all material labour T&P and grauting in cement concrete work etc. complete |
| 18 | P/F CPVC pipes having thermal stability for hot & cold water supply as per s.i.no.8 C ch-23 Internal work |
| 19 | P/F CPVC pipes having thermal stability for hot & cold water supply as per s.i.no.10d C ch-23 |
| 20 | P/F CPVC pipes having thermal stability for hot & cold water supply as per s.i.no.10f C ch-23 |
| 21 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality 32mm dia DSR no.18.17.2 |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. si no.18.12.8 |
| 23 | Supply and fixing of fountain with pump i/c all material labour T&P etc. complete. |
| 24 | Supply and fixing of Dr. BR Ambedkar statue i/c all labour T&P etc. complete. |
| 25 | installation of 1.50 hp summer |
| 26 | IProviding & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge. as DSR code no. 2.34 page-89 |
| 27 | P/f of Wiring point with 1.5 sq mm FRLSH PVC insulated multistrand single core copper conductor cable in pvc conduit with 14 swg copper earth continuity wire GP box, piano type switch and ceiling rose holder on and earthing point |
| 28 | Wiring for light/power plug with FRLSH PVC insulated multistrand single core copper conductor cable in pvc conduit with 4sq. earth continuity wire requireda. 2×4sq.mm as code no.1.12 |
| 29 | b. 2×6sq.mm as code no.1.14.4 |
| 30 | c. 2×10sq.mm as code no.1.14.5 |
| 31 | Supply and fixing of mcb distibution board as code no.2.4.2 |
| 32 | Supply and fixing of 5 to 32 Amp MCB (10kA) CAT A as code no. 2.10.1 |
| 33 | 16 amp switch as code no. 1.23.3 |
| 34 | 6 pin 16 amp socket as code no. 1.23.5 |
| 35 | S/M aluminium lugs as code no. 9.1.1 |
| 36 | S/L of dwc HDPE pipe of ISI mark i/c all 75mm dia. As per Gem. 1 piece=6.0metre |
| 37 | LED rgb colour light |
| 38 | LED wall light 5 watt |
| 39 | Decorative Lighting Pole with Dual Arm |
| 40 | street light decorative |
| 41 | Earthing with G.I. earth pipe 4.5m long and 40mm dia i/c accessories and masonary work with cover plate with charcoal and salt required as code no. 5.2 |
| 42 | P/F signboard of black granite plate in Brick masonary in Cement mortar i/c all complete Please Enable Macros to View BoQ information |