|
| 1 | Retarring |
| 2 | 3.2:Preparation of Foundation for Embankment Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. |
| 3 | OD309806/2025-2026:Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade |
| 4 | 4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead |
| 5 | 5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 |
| 6 | 5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 7 | 5.5.B.2a:Modified Penetration Macadam 75 mm thick using Bitumen S-65 Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. (B) 75 mm thick :- (II) Bitumen (S-65) |
| 8 | 5.2.1a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 9 | 75.5.11.1.A.2Z:Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 and Antistripping Agent Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual Means Type A (II) Bitumen (S-65) |
| 10 | OD329215/2025-2026:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish,lead upto 50m and lift up to 1.50m.All kinds of soil. |
| 11 | 4.11.1:Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. (i) Using naturally occuring gravel |
| 12 | OD329198/2025-2026:Interlocking Concrete Block Pavement Providing and Laying of InterlockingConcrete Block Pavements having thickness 80 mm as per drawings and TechnicalSpecification Clause 1504. |
| 13 | 75.8.1.1.A:Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification(i) Nominal mix (1:2:4) |
| 14 | OD307503/2025-2026:Supplying and Fixing Information board 75x60 cm using GI pipes as post and MS sheet surrounded by MS angles including painting, lettering and fixing etc. complete. |
| 15 | OD329110/2025-2026:Providing and fixing of direction and place identification retro-reflectorised sign with 7 yearswarranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixedover aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick witharea not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 andsupported on GI pipe pole 50mm NB-2 nos confirming to IS 1239 firmly fixed to the ground bymeans of properly designed foundation with M 15 grade cement concrete min size 40 cm x 40cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats ofepoxy painting over epoxy primer and as per approved drawing and clause 801 includinglettering symbols etc. (Derived from MoRD spec 10.3.A.2) Please Enable Macros to View BoQ information |